Lun Bian
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lun Bian has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
Chunhui He
Guangzhou Promise Biologics Co., Ltd, No. 1 Wanbao North Street, Panyu District, Guangzhou, China
1 shared publicationDawei Shi
Division II of In Vitro Diagnostics for Infectious Diseases, Institute for In Vitro Diagnostics Control, National Institutes for Food and Drug Control, Beijing, China
1 shared publication- Fang Hu
Southern Medical University
1 shared publication - Guanfeng Lin
Key Laboratory of Antibody Engineering of Guangdong Higher Education Institutes, Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, China
1 shared publication Ke Ye
Key Laboratory of Antibody Engineering of Guangdong Higher Education Institutes, Institute of Antibody Engineering, School of Laboratory Medicine and Biotechnology, Southern Medical University, Guangzhou, China
1 shared publication- Lei Zheng
Department of Laboratory Medicine Nanfang Hospital Southern Medical University Guangzhou China
1 shared publication
Latest Publications
- Open Access
- 30 November 2023
- Published by Wiley in Advanced Science
- Vol. 11 (4) , e2305774
Fluorescence‐Quenching Lateral Flow Immunoassay for “Turn‐On” and Sensitive Detection of Anti‐SARS‐Cov‐2 Neutralizing Antibodies in Human Serum
The titer of anti‐severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) neutralizing antibodies (NAbs) in the human body is an essential reference for evaluating the acquired protective immunity and resistance to SARS‐CoV‐2 infection. In this study, a fluorescence‐quenching lateral flow immunoassay (FQ‐LFIA) is established for quantitative detection of anti‐SARS‐CoV‐2 NAbs in the sera of individuals who are vaccinated or infected within 10 min. The ultrabright aggregation‐induced emission properties encapsulated in nanoparticles, AIE490NP, are applied in the established FQ‐LFIA with gold nanoparticles to achieve a fluorescence “turn‐on” competitive immunoassay. Under optimized conditions, the FQ‐LFIA quantitatively detected 103 positive and 50 negative human serum samples with a limit of detection (LoD) of 1.29 IU mL−1. A strong correlation is present with the conventional pseudovirus‐based virus neutralization test (R2 = 0.9796, P < 0.0001). In contrast, the traditional LFIA with a “turn‐off” mode can only achieve a LoD of 11.06 IU mL−1. The FQ‐LFIA showed excellent sensitivity to anti‐SARS‐CoV‐2 NAbs. The intra‐ and inter‐assay precisions of the established method are below 15%. The established FQ‐LFIA has promising potential as a rapid and quantitative method for detecting anti‐SARS‐CoV‐2 NAbs. FQ‐LFIA can also be used to detect various biomarkers.
- 30 November 2023
- Published by Wiley in Advanced Science
- Vol. 11 (4) , e2305774
Open AccessFluorescence‐Quenching Lateral Flow Immunoassay for “Turn‐On” and Sensitive Detection of Anti‐SARS‐Cov‐2 Neutralizing Antibodies in Human Serum
The titer of anti‐severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) neutralizing antibodies (NAbs) in the human body is an essential reference for evaluating the acquired protective immunity and resistance to SARS‐CoV‐2 infection. In this study, a fluorescence‐quenching lateral flow immunoassay (FQ‐LFIA) is established for quantitative detection of anti‐SARS‐CoV‐2 NAbs in the sera of individuals who are vaccinated or infected within 10 min. The ultrabright aggregation‐induced emission properties encapsulated in nanoparticles, AIE490NP, are applied in the established FQ‐LFIA with gold nanoparticles to achieve a fluorescence “turn‐on” competitive immunoassay. Under optimized conditions, the FQ‐LFIA quantitatively detected 103 positive and 50 negative human serum samples with a limit of detection (LoD) of 1.29 IU mL−1. A strong correlation is present with the conventional pseudovirus‐based virus neutralization test (R2 = 0.9796, P < 0.0001). In contrast, the traditional LFIA with a “turn‐off” mode can only achieve a LoD of 11.06 IU mL−1. The FQ‐LFIA showed excellent sensitivity to anti‐SARS‐CoV‐2 NAbs. The intra‐ and inter‐assay precisions of the established method are below 15%. The established FQ‐LFIA has promising potential as a rapid and quantitative method for detecting anti‐SARS‐CoV‐2 NAbs. FQ‐LFIA can also be used to detect various biomarkers.