Kazuya Morino
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kazuya Morino has a total of 136 co-authors. Here are the top co-authors by number of shared publications:
- Masahiro Miyake
Kyoto University Graduate School of Medicine
5 shared publications Shogo Numa
Department of Ophthalmology, Kyoto University Graduate School of Medicine, Kyoto, Japan
4 shared publicationsYasuharu Tabara
Center for Genomic Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
4 shared publicationsAkitaka Tsujikawa
Department of Ophthalmology, Kyoto University Graduate School of Medicine, Kyoto, Japan
3 shared publicationsFumihiko Matsuda
Center for Genomic Medicine, Kyoto University Graduate School of Medicine, Kyoto, Japan
3 shared publications- Masato Akiyama
Department of Ocular Pathology and Imaging Science, Graduate School of Medical Sciences, Kyushu University, Fukuoka, Japan
3 shared publications
Latest Publications
- Open Access
- 19 March 2026
- Published by Elsevier in Ophthalmology Science
- Vol. 6 (6) , 101165
Genome-Wide Meta-Analysis for High Myopia Provides Insights into Disease Mechanisms and Reveals a Causal Link to Primary Open-Angle Glaucoma
- 19 March 2026
- Published by Elsevier in Ophthalmology Science
- Vol. 6 (6) , 101165
Open AccessGenome-Wide Meta-Analysis for High Myopia Provides Insights into Disease Mechanisms and Reveals a Causal Link to Primary Open-Angle Glaucoma
- Open Access
- 4 September 2025
- Published by Elsevier in Ophthalmology Science
- Vol. 6 (1) , 100937
Potential Negative Feedback between Age and Baseline Axial Length on Axial Elongation in High Myopia
- 4 September 2025
- Published by Elsevier in Ophthalmology Science
- Vol. 6 (1) , 100937
Open AccessPotential Negative Feedback between Age and Baseline Axial Length on Axial Elongation in High Myopia
- Open Access
- 28 August 2025
- Published by Springer Nature in Communications Medicine
- Vol. 5 (1) , 1-7
A genome-wide association between foveal thickness and arrhythmia
Background The fovea is one of the most crucial parts of the visual system and has a special structure. We aimed to identify susceptibility single nucleotide polymorphisms (SNPs) for foveal thickness in a large Japanese cohort. Methods Genome-wide association study (GWAS) and replication studies were conducted in 9850 individuals from the Nagahama Study (from 2013 to 2016) and 935 individuals from the Hisayama Study. Genome-wide quantitative trait loci analyses and phenome-wide association study (PheWAS) were conducted using Biobank Japan Data for novel susceptibility SNPs. Finally, phenotypic associations were evaluated in the Nagahama Study. Results Here we show that rs4903064, located in Double PHD Fingers 3 (DPF3), is genome-wide significantly associated with foveal thickness, which is confirmed by replication studies and meta-analysis (β = 2.18, standard error = 0.59, P = 2.93 × 10−13). PheWAS identifies that the SNP was phenome-wide significantly associated with arrhythmia (β = −0.049, SE = 0.012, P = 2.50 × 10−5). In the Nagahama Study, individuals with a thicker fovea have a significantly lower risk of premature atrial/ventricular contraction (odds ratio = 0.86, 95% confidence interval = 0.75 to 0.98, P-value = 0.022). Conclusions We identify a novel foveal thickness susceptibility gene that is also associated with arrhythmia. Individuals with premature atrial/ventricular contraction may be advised to undergo ophthalmological evaluation as necessary.
- 28 August 2025
- Published by Springer Nature in Communications Medicine
- Vol. 5 (1) , 1-7
Open AccessA genome-wide association between foveal thickness and arrhythmia
Background The fovea is one of the most crucial parts of the visual system and has a special structure. We aimed to identify susceptibility single nucleotide polymorphisms (SNPs) for foveal thickness in a large Japanese cohort. Methods Genome-wide association study (GWAS) and replication studies were conducted in 9850 individuals from the Nagahama Study (from 2013 to 2016) and 935 individuals from the Hisayama Study. Genome-wide quantitative trait loci analyses and phenome-wide association study (PheWAS) were conducted using Biobank Japan Data for novel susceptibility SNPs. Finally, phenotypic associations were evaluated in the Nagahama Study. Results Here we show that rs4903064, located in Double PHD Fingers 3 (DPF3), is genome-wide significantly associated with foveal thickness, which is confirmed by replication studies and meta-analysis (β = 2.18, standard error = 0.59, P = 2.93 × 10−13). PheWAS identifies that the SNP was phenome-wide significantly associated with arrhythmia (β = −0.049, SE = 0.012, P = 2.50 × 10−5). In the Nagahama Study, individuals with a thicker fovea have a significantly lower risk of premature atrial/ventricular contraction (odds ratio = 0.86, 95% confidence interval = 0.75 to 0.98, P-value = 0.022). Conclusions We identify a novel foveal thickness susceptibility gene that is also associated with arrhythmia. Individuals with premature atrial/ventricular contraction may be advised to undergo ophthalmological evaluation as necessary.
- Open Access
- 18 August 2025
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 280, 193-202
Sleep Disturbance as a Risk Factor for Retinal Neurodegeneration and Subsequent Glaucoma
- 18 August 2025
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 280, 193-202
Open AccessSleep Disturbance as a Risk Factor for Retinal Neurodegeneration and Subsequent Glaucoma
- Open Access
- 1 November 2024
- Published by Elsevier in Ophthalmology Retina
- Vol. 9 (4) , 367-377
Genome-wide Meta-analysis for Myopic Macular Neovascularization Identified a Novel Susceptibility Locus and Revealed a Shared Genetic Susceptibility with Age-Related Macular Degeneration
- 1 November 2024
- Published by Elsevier in Ophthalmology Retina
- Vol. 9 (4) , 367-377
Open AccessGenome-wide Meta-analysis for Myopic Macular Neovascularization Identified a Novel Susceptibility Locus and Revealed a Shared Genetic Susceptibility with Age-Related Macular Degeneration
- 17 July 2024
- Published by Elsevier in Ophthalmology
- Vol. 131 (11) , 1271-1280
Genetic Risk Stratification of Primary Open-Angle Glaucoma in Japanese Individuals
- 17 July 2024
- Published by Elsevier in Ophthalmology
- Vol. 131 (11) , 1271-1280
Genetic Risk Stratification of Primary Open-Angle Glaucoma in Japanese Individuals
- Open Access
Short-Term Postoperative Outcome of Baerveldt Glaucoma Implant with Two Tubes Inserted into the Vitreous Cavity
Here, we report a new surgical technique designed to increase filtration volume and reduce intraocular pressure (IOP) in glaucoma and its one-year outcome. Two tubes were created from a single Baerveldt glaucoma implant (BI) by folding the tube in a U-shape and incising only the outer edge of the stretched loop tip. The tubes were placed into the vitreous cavity via the pars plana through a long scleral tunnel, without a scleral valve or graft patch. Twenty eyes of 18 patients with neovascular glaucoma were included. This technique was performed in 10 eyes of 10 patients (double group), and outcomes were compared to 10 eyes of eight patients in which a single tube BI was inserted (single group). The primary outcome measures included IOP, supplemental medical therapy score (SMTS), and intraoperative and postoperative complications before and after surgery at 12 months. The mean IOP (SMTS) were 32.0 ± 11.33 mmHg (4.1) in the double group and 29.7 ± 6.31 mmHg (5.7) in the single group, preoperatively reduced to 11.8 ± 2.70 mmHg (0.2) (63% reduction, p < 0.004) and 14.2 ± 4.05 mmHg (1.1) (52% reduction, p < 0.002) after 12 months, respectively. SMTS showed 95% (p = 0.005) and 89% (p = 0.005) reductions, respectively. Although there was no significant difference in IOP between the two groups at 12 months (p = 0.16), there were significant differences in the SMTS between the two groups before, and 6 and 12 months after, surgery (p = 0.01, 0.04 and 0.04, respectively). A reduction in the SMTS suggests that increasing filtration volume by placing two tubes has the potential to further reduce IOP as compared with a single tube.
Open AccessShort-Term Postoperative Outcome of Baerveldt Glaucoma Implant with Two Tubes Inserted into the Vitreous Cavity
Here, we report a new surgical technique designed to increase filtration volume and reduce intraocular pressure (IOP) in glaucoma and its one-year outcome. Two tubes were created from a single Baerveldt glaucoma implant (BI) by folding the tube in a U-shape and incising only the outer edge of the stretched loop tip. The tubes were placed into the vitreous cavity via the pars plana through a long scleral tunnel, without a scleral valve or graft patch. Twenty eyes of 18 patients with neovascular glaucoma were included. This technique was performed in 10 eyes of 10 patients (double group), and outcomes were compared to 10 eyes of eight patients in which a single tube BI was inserted (single group). The primary outcome measures included IOP, supplemental medical therapy score (SMTS), and intraoperative and postoperative complications before and after surgery at 12 months. The mean IOP (SMTS) were 32.0 ± 11.33 mmHg (4.1) in the double group and 29.7 ± 6.31 mmHg (5.7) in the single group, preoperatively reduced to 11.8 ± 2.70 mmHg (0.2) (63% reduction, p < 0.004) and 14.2 ± 4.05 mmHg (1.1) (52% reduction, p < 0.002) after 12 months, respectively. SMTS showed 95% (p = 0.005) and 89% (p = 0.005) reductions, respectively. Although there was no significant difference in IOP between the two groups at 12 months (p = 0.16), there were significant differences in the SMTS between the two groups before, and 6 and 12 months after, surgery (p = 0.01, 0.04 and 0.04, respectively). A reduction in the SMTS suggests that increasing filtration volume by placing two tubes has the potential to further reduce IOP as compared with a single tube.
- Open Access
- 1 January 2021
- Published by Wiley in Journal of Ophthalmology
- Vol. 2021 (1)
A Modified Intrascleral Intraocular Lens Fixation Technique Using 27‐Gauge Blunted Needles with Fewer Intraocular Manipulations
A new method for intraocular lens (IOL) fixation in the scleral tunnel using two common 27G blunted needles and an ultrathin 30G needle with fewer intraocular manipulations was developed. Half‐depth scleral flaps were prepared, and vertically angled sclerotomies were performed under each scleral flap, 2 mm from the limbs with a 20G microblade or a 26G needle. Two bent 27G blunted needles connected the sclerotomy and corneoscleral incisions. One haptic was inserted into this bent 27G blunted needle extraocularly and extruded through the sclerotomy site. Each haptic was inserted into the lumen of the preplaced ultrathin 30G needle and buried into the scleral tunnel. In this retrospective study, we reviewed the outcomes of this new technique in patients with at least 3 months’ follow‐up data. Iris capture of the IOL was not observed in any case, and IOL repositioning was not performed either. Astigmatism induced by intraocular aberration was almost as same as that with other methods. Our technique can be performed in any operation room without any extra instruments. This trial is registered with UMIN000044350 .
- 1 January 2021
- Published by Wiley in Journal of Ophthalmology
- Vol. 2021 (1)
Open AccessA Modified Intrascleral Intraocular Lens Fixation Technique Using 27‐Gauge Blunted Needles with Fewer Intraocular Manipulations
A new method for intraocular lens (IOL) fixation in the scleral tunnel using two common 27G blunted needles and an ultrathin 30G needle with fewer intraocular manipulations was developed. Half‐depth scleral flaps were prepared, and vertically angled sclerotomies were performed under each scleral flap, 2 mm from the limbs with a 20G microblade or a 26G needle. Two bent 27G blunted needles connected the sclerotomy and corneoscleral incisions. One haptic was inserted into this bent 27G blunted needle extraocularly and extruded through the sclerotomy site. Each haptic was inserted into the lumen of the preplaced ultrathin 30G needle and buried into the scleral tunnel. In this retrospective study, we reviewed the outcomes of this new technique in patients with at least 3 months’ follow‐up data. Iris capture of the IOL was not observed in any case, and IOL repositioning was not performed either. Astigmatism induced by intraocular aberration was almost as same as that with other methods. Our technique can be performed in any operation room without any extra instruments. This trial is registered with UMIN000044350 .