Sheikh Javed Iqbal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sheikh Javed Iqbal has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Faisal Jamsheed
Department of Electrical Engineering National Institute of Technology Srinagar Hazratbal Srinagar Jammu and Kashmir 190006 India
3 shared publications - Ikhlaq Hussain
Department of Electrical Engineering, National Institute of Technology, Srinagar, India
3 shared publications - Rayes Ahmad Lone
Islamic University of Science and Technology, Pulwama, India
3 shared publications - Ahmed Sharique Anees
Department of Electrical Engineering, Islamic University of Science and Technology, Kashmir, India
2 shared publications - Raja Owais
Department of Electrical Engineering, National Institute of Technology (NIT) Srinagar, Srinagar, India
2 shared publications - Ahmed Sharique Anees
Islamic University of Science and Technology, Pulwama, India
1 shared publication
Latest Publications
- 17 August 2025
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 51 (6) , 7897-7912
Hybrid Optimization Technique for Siting and Sizing of Distributed Generators and DSTATCOM to Minimize Power Loss and Voltage Deviation with Time-Domain Analysis
- 17 August 2025
- Published by Springer Nature in Arabian Journal for Science and Engineering
- Vol. 51 (6) , 7897-7912
Hybrid Optimization Technique for Siting and Sizing of Distributed Generators and DSTATCOM to Minimize Power Loss and Voltage Deviation with Time-Domain Analysis
- 8 March 2025
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 106 (6) , 1973-1991
Sovereign Butterfly Optimization and Flyback Converter Integration for Robust Photovoltaic Systems Under Partial Shading
- 8 March 2025
- Published by Springer Nature in Journal of The Institution of Engineers (India): Series B
- Vol. 106 (6) , 1973-1991
Sovereign Butterfly Optimization and Flyback Converter Integration for Robust Photovoltaic Systems Under Partial Shading
- 20 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (1) , 460-469
Adaptive Control of DC Link Voltage in a DFIG-Based Hybrid Grid-Interactive System Using Gaussian Kernel Least Mean Sixth Adaptive Filter
The interoperability of wind and solar energy is a potential alternative to improve reliability and reduce the probability of an energy supply crisis. Due to the stochastic nature of both the sources, maintaining high quality performance in grid-intertie hybrid energy systems, particularly for nonlinear loads, is essential for efficient use of energy. This article presents a novel Gaussian kernel least mean sixth (GKLMSi) grid interactive algorithm for the hybrid renewable energy system along with adaptively controlled dc link voltage. GKLMSi adaptive control effectively tracks various time varying power quality events such as, voltage fluctuations, load disturbances, reactive power variations, and harmonic parameters that are of high-order nonlinearities. The adaptive dc link voltage control reduces the stress on the converters during voltage fluctuations and generates sufficient dc link voltage reference for the converter current control. This minimizes switching losses and enhances the reliability and effectiveness of the system especially during the abnormal voltage operations.
- 20 June 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 72 (1) , 460-469
Adaptive Control of DC Link Voltage in a DFIG-Based Hybrid Grid-Interactive System Using Gaussian Kernel Least Mean Sixth Adaptive Filter
The interoperability of wind and solar energy is a potential alternative to improve reliability and reduce the probability of an energy supply crisis. Due to the stochastic nature of both the sources, maintaining high quality performance in grid-intertie hybrid energy systems, particularly for nonlinear loads, is essential for efficient use of energy. This article presents a novel Gaussian kernel least mean sixth (GKLMSi) grid interactive algorithm for the hybrid renewable energy system along with adaptively controlled dc link voltage. GKLMSi adaptive control effectively tracks various time varying power quality events such as, voltage fluctuations, load disturbances, reactive power variations, and harmonic parameters that are of high-order nonlinearities. The adaptive dc link voltage control reduces the stress on the converters during voltage fluctuations and generates sufficient dc link voltage reference for the converter current control. This minimizes switching losses and enhances the reliability and effectiveness of the system especially during the abnormal voltage operations.
- 30 November 2023
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 21 (9) , 2084-2101
Hybrid technique for optimal placement and sizing of distributed generation units considering real and reactive power injection
- 30 November 2023
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 21 (9) , 2084-2101
Hybrid technique for optimal placement and sizing of distributed generation units considering real and reactive power injection
- Open Access
ILA Optimisation Based Control for Enhancing DC Link Voltage with Seamless and Adaptive VSC Control in a PV-BES Based AC Microgrid
The paper presents a grid-connected microgrid with a photovoltaic system and a battery as a storage element. The optimal design and control of storage elements and power quality improvement are enhanced using sigmoid-function-based variable step size (SFB-VSS) adaptive LMS control. The DC-link voltage and battery current are enhanced using an ILA-optimization-based PI controller. Comparative analysis shows that an ILA-optimized PI controller improves battery stress and DC-link voltage fluctuations, enhancing overall system stability. The relative percentage error of Vdc is only 0.5714% for ILA-optimized values as compared to GA, PSO, and manually tuned PI gains which are 0.857%, 1.14285%, and 0.86%, respectively. ILA-optimized parameters also enhance battery current, reducing stress on the battery. The system was studied under various dynamic conditions, achieving power balance in all conditions. The system has the capability of seamless transfer of control from GC mode to SA mode when the grid is disconnected. The proposed VSC control shows better performance in steady-state and dynamic conditions, maintaining a THD under 5%, which follows IEEE standard 519, and providing better DC offset rejection, fewer oscillations in the weight component of the load, and better convergence. The proposed control also enhances the frequency of the grid, ensuring a smooth transition between modes. The system is simulated in the MATLAB Simulink environment, and all the optimization techniques were carried out offline.
Open AccessILA Optimisation Based Control for Enhancing DC Link Voltage with Seamless and Adaptive VSC Control in a PV-BES Based AC Microgrid
The paper presents a grid-connected microgrid with a photovoltaic system and a battery as a storage element. The optimal design and control of storage elements and power quality improvement are enhanced using sigmoid-function-based variable step size (SFB-VSS) adaptive LMS control. The DC-link voltage and battery current are enhanced using an ILA-optimization-based PI controller. Comparative analysis shows that an ILA-optimized PI controller improves battery stress and DC-link voltage fluctuations, enhancing overall system stability. The relative percentage error of Vdc is only 0.5714% for ILA-optimized values as compared to GA, PSO, and manually tuned PI gains which are 0.857%, 1.14285%, and 0.86%, respectively. ILA-optimized parameters also enhance battery current, reducing stress on the battery. The system was studied under various dynamic conditions, achieving power balance in all conditions. The system has the capability of seamless transfer of control from GC mode to SA mode when the grid is disconnected. The proposed VSC control shows better performance in steady-state and dynamic conditions, maintaining a THD under 5%, which follows IEEE standard 519, and providing better DC offset rejection, fewer oscillations in the weight component of the load, and better convergence. The proposed control also enhances the frequency of the grid, ensuring a smooth transition between modes. The system is simulated in the MATLAB Simulink environment, and all the optimization techniques were carried out offline.
- 3 May 2023
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 21 (3) , 682-700
Optimal location and sizing of distributed generation for distribution systems: An improved analytical technique
Distributed generation (DG) significantly improves power system reliability and voltage profile, and reduces power losses. These benefits can be maximized by optimizing the DG utilization, which greatly depends on adequate number, size, and placement of DG. This study proposes a high-convergence optimization technique for optimal DG placement in distribution networks, aiming to reduce power losses and improve voltage profile and voltage stability index. The technique is tested on a 7-bus system before being verified on the IEEE 33-bus system. After validation, it is tested on a 71-bus distribution network (DN). The estimated ideal size for a single DG is used as a limit for determining the optimal placement and size of multiple DG units. The results show that there is a loss reduction of 70.09%, 61.43%, and 71.15% for the 7-bus, IEEE 33-bus, and 71-bus systems, respectively, from their base case loss. The average absolute error of voltage of the aforementioned buses also shows similar enhancement, decreasing from 0.0144, 0.0561, and 0.0527, to 0.0058, 0.0209, and 0.0184, respectively. The voltage stability index of each DN has increased significantly in comparison to the base case. The comparison demonstrates that the proposed technique can provide better results for any size of distribution network.
- 3 May 2023
- Published by Taylor & Francis in International Journal of Green Energy
- Vol. 21 (3) , 682-700
Optimal location and sizing of distributed generation for distribution systems: An improved analytical technique
Distributed generation (DG) significantly improves power system reliability and voltage profile, and reduces power losses. These benefits can be maximized by optimizing the DG utilization, which greatly depends on adequate number, size, and placement of DG. This study proposes a high-convergence optimization technique for optimal DG placement in distribution networks, aiming to reduce power losses and improve voltage profile and voltage stability index. The technique is tested on a 7-bus system before being verified on the IEEE 33-bus system. After validation, it is tested on a 71-bus distribution network (DN). The estimated ideal size for a single DG is used as a limit for determining the optimal placement and size of multiple DG units. The results show that there is a loss reduction of 70.09%, 61.43%, and 71.15% for the 7-bus, IEEE 33-bus, and 71-bus systems, respectively, from their base case loss. The average absolute error of voltage of the aforementioned buses also shows similar enhancement, decreasing from 0.0144, 0.0561, and 0.0527, to 0.0058, 0.0209, and 0.0184, respectively. The voltage stability index of each DN has increased significantly in comparison to the base case. The comparison demonstrates that the proposed technique can provide better results for any size of distribution network.
- 8 December 2022
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 70 (2) , 2133-2147
Optimal Control of BESS for Improved Grid Integration of the Hybrid DFIG/PV System Using Dual-Layer Adaptive Control
- 8 December 2022
- Published by Taylor & Francis in IETE Journal of Research
- Vol. 70 (2) , 2133-2147
Optimal Control of BESS for Improved Grid Integration of the Hybrid DFIG/PV System Using Dual-Layer Adaptive Control
- 2 October 2022
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 44 (1) , 124-130
Estimation of irradiance and temperature of solar photovoltaic system operating at maximum power point
This paper presents a novel method for estimating irradiance and temperature simultaneously for a photovoltaic (PV) system operating at maximum power point (MPP), utilizing only datasheet information. This is the first estimation approach that properly estimates the irradiance and temperature of PV systems running at MPP with low irradiance levels, hence demonstrating its applicability over the entire irradiance range. The uniqueness of the equations lies in their firm theoretical foundation, which is demonstrated by their excellent agreement with the PV single-diode model (SDM). Extraction and translation of PV system parameters is carried out using the recently introduced Lambert-W function in PV modeling. In the context of rapidly changing irradiance and temperature situations, the proposed method is compared to current techniques available in the literature, and the results show that the proposed estimation method outperforms the state-of-the-art.
- 2 October 2022
- Published by Taylor & Francis in International Journal of Ambient Energy
- Vol. 44 (1) , 124-130
Estimation of irradiance and temperature of solar photovoltaic system operating at maximum power point
This paper presents a novel method for estimating irradiance and temperature simultaneously for a photovoltaic (PV) system operating at maximum power point (MPP), utilizing only datasheet information. This is the first estimation approach that properly estimates the irradiance and temperature of PV systems running at MPP with low irradiance levels, hence demonstrating its applicability over the entire irradiance range. The uniqueness of the equations lies in their firm theoretical foundation, which is demonstrated by their excellent agreement with the PV single-diode model (SDM). Extraction and translation of PV system parameters is carried out using the recently introduced Lambert-W function in PV modeling. In the context of rapidly changing irradiance and temperature situations, the proposed method is compared to current techniques available in the literature, and the results show that the proposed estimation method outperforms the state-of-the-art.
- 19 September 2022
- Published by Springer Nature in Neural Computing and Applications
- Vol. 35 (1) , 663-679
Simplified artificial neural network based online adaptive control scheme for nonlinear systems
- 19 September 2022
- Published by Springer Nature in Neural Computing and Applications
- Vol. 35 (1) , 663-679
Simplified artificial neural network based online adaptive control scheme for nonlinear systems