PAPongsakorn Apinsathanon

Pongsakorn Apinsathanon

*This is an algorithmically generated author record based on publicly available information.

Pongsakorn Apinsathanon has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    The Impact of Various Surface Treatments on Adhesion Between Co–Cr Alloy and Acrylic Teeth

    by Punnita Chotcomwongse, Pongsakorn Apinsathanon, Basel Mahardawi, Palawat Laoharungpisit, Pheeradej Na Nan, Napapa Aimjirakul

    Objective: This study aimed to assess the shear bond strength (SBS) between cobalt–chromium (Co–Cr) alloy and acrylic resin teeth using various surface conditioning methods and to investigate the failure modes associated with these methods. Materials and Methods: A total of 53 Co–Cr specimens were fabricated and randomly assigned to five groups ( n = 10 per group) based on the type of surface treatment: (1) polymethyl methacrylate (PMMA; control group), (2) Clearfil Ceramic Primer Plus + PMMA, (3) M&C Primer + PMMA, (4) Super‐Bond Universal, and (5) M&C Primer + Super‐Bond Universal. Each specimen was subsequently bonded to an acrylic resin tooth. Three specimens from both the control and primer‐treated groups were reserved for scanning electron microscopy (SEM) analysis. All samples were stored in distilled water at 37 ± 1°C for 24 h before SBS evaluation with a universal testing machine. Statistical Analysis: Statistical analysis was performed using one‐way analysis of variance (ANOVA) followed by Tukey’s HSD post hoc test. Results: A statistically significant difference in bond strength was observed among the experimental groups ( p < 0.05), with the Super‐Bond Universal group exhibiting the highest bond strength (8.01 ± 1.05 megapascals [MPa]), compared to the control group (3.07 ± 0.48 MPa). The control group and the PMMA + M&C Primer group exhibited predominantly adhesive failures, while the other groups showed a combination of adhesive and mixed failures. Conclusion: Super‐Bond Universal without primer achieved the highest bond strength, and the application of primers prior to PMMA or resin cement placement significantly improved bonding between Co–Cr alloys and acrylic resin teeth, suggesting that appropriate surface conditioning can enhance denture repair outcomes.


  • Open Access

    Utilizing Intraoral Scanning and Computer-Aided Design/Manufacturing for Creating a New Dental Crown to Match an Existing Removable Prosthesis: A Case Report

    by Pongsakorn Apinsathanon

    This clinical report demonstrates the successful dental crown treatment for a 39-year-old female patient with a fractured posterior lower right second molar wearing a removable partial prosthesis and refusing to make a new one. The patient's preference for a new dental crown on her lower right second molar was respected, and an intraoral scanner (IOS) was employed to capture the fractured abutment's anatomy, which also serves as part of her removable denture. Following abutment preparation, a second IOS scan recorded the modified abutment. A temporary crown of the abutment was fabricated and secured to protect the prepared abutment. Comprehensive data, including an intraoral scan with an existing removable denture file, an intraoral scan without a removable denture, an intraoral scan of an unprepared abutment file, an intraoral scan of prepared abutment, and a digital photo of shade selection were transmitted to the dental laboratory. Utilizing computer-aided design/computer-aided manufacturing technology, a new dental crown compatible with the existing removable prosthesis was created. After fitting the new crown, occlusion, aesthetics, function, and attachment assessments were conducted to ensure optimal results. Subsequent follow-ups confirmed the patient's satisfaction with the functionality, aesthetics, and fit of her removable partial denture with the new dental crown.


  • Open Access

    The Effects of Abutment Finish Lines on the Penetration Characteristics of Elastomers into the Simulated Gingival Sulcus

    by Atiwat Jaroenpiboon, Pongsakorn Apinsathanon, Pheeradej Na Nan, Napapa Aimjirakul

    Objective The aim of this study was to determine the effect of finish lines on the penetration ability of polyether and polyvinyl siloxane impression material into the simulated gingival sulcus. Materials and Methods Three types of finish line (chamfer, deep chamfer, and radial shoulder) were impressed with two types of elastomeric impression material (polyether and polyvinyl siloxane) using a two-step impression technique. Ten samples of each finish line were prepared and then separated into two groups of impression material: polyether and polyvinyl siloxane. The model of the simulated gingival sulcus had a width of 0.1 mm and a depth of 3.5 mm with a subgingival finish line of 0.5 mm. The effect of the finish lines on the penetration ability of these impression materials was analyzed using a two-way analysis of variance (ANOVA) and Tukey's multiple comparison tests at a statistically significant level of 0.05. Results A two-way ANOVA revealed a significant difference among finish lines, impression materials, and their interaction. The deep chamfer and radial shoulder finish lines displayed significantly higher penetration ability than the chamfer finish line. Moreover, polyether revealed significantly higher penetration ability than polyvinyl siloxane. Conclusion The finish lines affected the penetration ability of the impression materials. Therefore, the simulated gingival sulcus model demonstrates that it is an effective way of examining impression materials' penetration abilities.


  • Open Access

    Penetration and Tensile Strength of Various Impression Materials of Vinylsiloxanether, Polyether, and Polyvinylsiloxane Impression Materials

    by Pongsakorn Apinsathanon, Bishwa Prakash Bhattarai, Suphachai Suphangul, Natthamet Wongsirichat, Napapa Aimjirakul

    Objectives The aim of this study was to evaluate and compare penetration ability and tensile strength among vinylsiloxanether (VSE), polyether (PE), and polyvinylsiloxane (PVS) elastomeric dental impression materials. Materials and Methods The models were constructed for penetration ability test by simulated gingival sulcus width and moist environment. The 0.05, 0.1, and 0.2 mm of simulated gingival sulcus widths were used. Each simulated gingival sulcus width was impressed 10 repeats per one elastomeric impression material. All extension of elastomeric dental impression materials was scaled by Measuring Microscope (MM-11; Nikon, Tokyo, Japan). On the issue of the tensile strength study, the models were constructed following type 1 of the ISO 37:2017 specifications and/or type C of ASTM.D412 specifications. The two-way analysis of variance (ANOVA) and Tukey's honest significant difference test were performed in the penetration ability test. The one-way ANOVA and Dunnett's T3 test were performed in the tensile strength test. The significance level was set at 0.05. Results PE showed the best extension into all widths of simulated sulcus followed by VSE and PVS, respectively. PVS was significantly higher in tensile strength than VSE and PE, while VSE was significantly higher than PE. Conclusion Penetration ability of elastomeric dental impression materials was depended on gingival sulcus width. The wider the sulcular width, the better the penetration ability of elastomeric dental impression materials. PE presented the best penetration ability, while the novel PVS showed highest tensile strength.