Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jun Geun Shin has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Single Camera-Based Dual-Channel Near-Infrared Fluorescence Imaging system

    by Janghoon Choi, Jun-Geun Shin, Yoon-Oh Tak, Youngseok Seo, Jonghyun Eom

    In this study, we propose a single camera-based dual-channel near-infrared (NIR) fluorescence imaging system that produces color and dual-channel NIR fluorescence images in real time. To simultaneously acquire color and dual-channel NIR fluorescence images of two fluorescent agents, three cameras and additional optical parts are generally used. As a result, the volume of the image acquisition unit increases, interfering with movements during surgical procedures and increasing production costs. In the system herein proposed, instead of using three cameras, we set a single camera equipped with two image sensors that can simultaneously acquire color and single-channel NIR fluorescence images, thus reducing the volume of the image acquisition unit. The single-channel NIR fluorescence images were time-divided into two channels by synchronizing the camera and two excitation lasers, and the noise caused by the crosstalk effect between the two fluorescent agents was removed through image processing. To evaluate the performance of the system, experiments were conducted for the two fluorescent agents to measure the sensitivity, crosstalk effect, and signal-to-background ratio. The compactness of the resulting image acquisition unit alleviates the inconvenient movement obstruction of previous devices during clinical and animal surgery and reduces the complexity and costs of the manufacturing process, which may facilitate the dissemination of this type of system.


  • Open Access

    Development of Intraoperative Near-Infrared Fluorescence Imaging System Using a Dual-CMOS Single Camera

    by Janghoon Choi, Jun Geun Shin, Hyuk-Sang Kwon, Yoon-Oh Tak, Hyeong Ju Park, Jin-Chul Ahn, Joo Beom Eom, Youngseok Seo, Jin Woo Park, Yongdoo Choi, et al.

    We developed a single-camera-based near-infrared (NIR) fluorescence imaging device using indocyanine green (ICG) NIR fluorescence contrast agents for image-induced surgery. In general, a fluorescent imaging system that simultaneously provides color and NIR images uses two cameras, which is disadvantageous because it increases the imaging head of the system. Recently, a single-camera-based NIR optical imaging device with quantum efficiency partially extended to the NIR region was developed to overcome this drawback. The system used RGB_NIR filters for camera sensors to provide color and NIR images simultaneously; however, the sensitivity and resolution of the infrared images are reduced by 1/4, and the exposure time and gain cannot be set individually when acquiring color and NIR images. Thus, to overcome these shortcomings, this study developed a compact fluorescent imaging system that uses a single camera with two complementary metal–oxide semiconductor (CMOS) image sensors. Sensitivity and signal-to-background ratio were measured according to the concentrations of ICG solution, exposure time, and camera gain to evaluate the performance of the imaging system. Consequently, the clinical applicability of the system was confirmed through the toxicity analysis of the light source and in vivo testing.


  • Open Access

    Double-Clad Optical Fiber-Based Multi-Contrast Noncontact Photoacoustic and Fluorescence Imaging System

    by Jun Geun Shin, Jonghyun Eom

    A noncontact photoacoustic and fluorescence dual-modality imaging system is proposed, which integrates a fiber-based fluorescence imaging system with noncontact photoacoustic imaging using a specially fabricated double-cladding fiber (DCF) coupler and a DCF lens. The performance of the DCF coupler and lens was evaluated, and the feasibility of this new imaging system was demonstrated using simple tubing phantoms with black ink and fluorophore. Our imaging results demonstrated that the multimodal imaging technique can simultaneously acquire photoacoustic and fluorescence images without coming into contact with the sample. Consequently, the developed method is the first noncontact scheme among multimodal imaging systems that is integrated with a photoacoustic imaging system, which can provide varied and complementary information about the sample.