Swapna Sreenivasagan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Swapna Sreenivasagan has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Aravind Kumar Subramanian
Department of Orthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India
2 shared publications - Abirami Selvaraj
Department of Orthodontics, Chettinad Dental College and Research Institute, Kelambakkam, Tamil Nadu, India
1 shared publication - Anand Marya
Department of Orthodontics, Faculty of Dentistry, University of Puthisastra, Phnom Penh, Cambodia
1 shared publication Aravind Kumar Subramanian
Department of Orthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences (SIMATS), Chennai, Tamil Nadu, India
1 shared publicationAshok K Sundramoorthy
Professor, Department of Prosthodontics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Chennai - 600077, Tamil Nadu, India
1 shared publicationAsmidha Thiyagarajan
Department of Dental Materials, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Chennai - 600077, Tamil Nadu, India
1 shared publication
Latest Publications
- Open Access
- 30 September 2026
- Published by IP Innovative Publication Pvt Ltd in Journal of Contemporary Orthodontics
- Vol. 10 (4) , 472-480
Anchorage and accuracy: Evaluating attachment-meditated fit in direct-printed clear aligners
Background : The evolution of clear aligner therapy has transitioned from traditional thermoforming toward direct 3D printing. This study aimed to evaluate and compare the marginal fit of directly printed aligners and indirectly fabricated thermoformed aligners using Scanning Electron Microscopy (SEM), while also investigating the influence of anchorage (attachments) on adaptation. Materials and Methods : Thirty-two specimens were divided into two primary groups: Group I (Directly printed TC-85DAC resin) and Group II (Indirectly fabricated PET-G). Each group was further subdivided based on the presence or absence of anchorage. Marginal gaps were measured at five distinct levels (P1–P5) on the tooth surface. Statistical analysis was performed using Mann-Whitney U, One-way ANOVA, and Pearson correlation tests (p < 0.05). Results : Direct printed aligners (Group I) revealed significantly lower mean marginal gaps compared to thermoformed aligners across all sites (p < 0.001). At the incisal edge, Group I gaps averaged 51.58 µm while Group II gaps measured to be 87.08 µm. The presence of anchorage in the form of attachment significantly improved seating at points P1–P4 (p≤0.002), though its effect at the lingual cervical margin (P5) was negligible (p = 0.78). Moreover, direct printed aligner demonstrated a highly predictable and associated fit across different sites, a characteristic which is absent in the thermoformed clear aligners. Conclusion : Direct 3D printing provides a superior and more probable marginal fit than traditional thermoforming clear aligners. The blend of direct fabrication and mechanical anchorage attains the highest level of adaptation, marking a noteworthy improvement in the precision and potential clinical efficiency of clear aligner therapy.
- 30 September 2026
- Published by IP Innovative Publication Pvt Ltd in Journal of Contemporary Orthodontics
- Vol. 10 (4) , 472-480
Open AccessAnchorage and accuracy: Evaluating attachment-meditated fit in direct-printed clear aligners
Background : The evolution of clear aligner therapy has transitioned from traditional thermoforming toward direct 3D printing. This study aimed to evaluate and compare the marginal fit of directly printed aligners and indirectly fabricated thermoformed aligners using Scanning Electron Microscopy (SEM), while also investigating the influence of anchorage (attachments) on adaptation. Materials and Methods : Thirty-two specimens were divided into two primary groups: Group I (Directly printed TC-85DAC resin) and Group II (Indirectly fabricated PET-G). Each group was further subdivided based on the presence or absence of anchorage. Marginal gaps were measured at five distinct levels (P1–P5) on the tooth surface. Statistical analysis was performed using Mann-Whitney U, One-way ANOVA, and Pearson correlation tests (p < 0.05). Results : Direct printed aligners (Group I) revealed significantly lower mean marginal gaps compared to thermoformed aligners across all sites (p < 0.001). At the incisal edge, Group I gaps averaged 51.58 µm while Group II gaps measured to be 87.08 µm. The presence of anchorage in the form of attachment significantly improved seating at points P1–P4 (p≤0.002), though its effect at the lingual cervical margin (P5) was negligible (p = 0.78). Moreover, direct printed aligner demonstrated a highly predictable and associated fit across different sites, a characteristic which is absent in the thermoformed clear aligners. Conclusion : Direct 3D printing provides a superior and more probable marginal fit than traditional thermoforming clear aligners. The blend of direct fabrication and mechanical anchorage attains the highest level of adaptation, marking a noteworthy improvement in the precision and potential clinical efficiency of clear aligner therapy.
- Open Access
- 1 June 2026
- Published by Wolters Kluwer Health in Dental Research Journal
- Vol. 23 (6)
Assessment of infra-zygomatic area for ideal placement of miniscrews: A systematic review and meta-analysis
Background: The infrazygomatic crest (IZC) is a commonly used extra-alveolar site for orthodontic miniscrew placement because of its favorable anatomical position and relatively dense cortical bone. However, variations in bone thickness, insertion height, and angulation can influence the stability and success of miniscrew placement. To systematically evaluate and synthesize the available evidence on the infrazygomatic crest region to determine the most suitable site, insertion height, and angulation for orthodontic miniscrew placement. Materials and Methods: A systematic search was conducted across PubMed, Embase, Web of Science, Scopus, the Cochrane Library, and grey literature sources including Google Scholar and OpenGrey for studies published up to March 2023. Studies assessing cortical bone thickness and anatomical characteristics of the IZC relevant to miniscrew placement were included. Thirteen studies met the inclusion criteria for qualitative synthesis, and nine studies providing quantitative data were included in the meta-analysis. Mean values and standard deviations of bone thickness and insertion height along the distobuccal root of the maxillary first molar at 70° angulation were extracted. Forest plots were generated to compare findings across studies. Risk of bias was assessed using the Quality Assessment of Measurement Accuracy Studies (QUAMAS) tool. Results: Among the included studies, most reported adequate bone thickness in the region buccal to the maxillary first molar. Meta-analysis indicated that sufficient bone thickness is generally observed when miniscrews are inserted at an angulation of approximately 60°-70°. The optimal insertion height was commonly reported between 10 and 15 mm above the occlusal plane, where greater cortical bone thickness was observed. Increasing insertion angulation and decreasing insertion height were associated with improved bone engagement and primary stability. Conclusion: The current evidence suggests that the region buccal to the maxillary first molar in the infrazygomatic crest is the most favorable site for orthodontic miniscrew placement. An insertion angle of approximately 60°-70° and a height of 10-15 mm above the occlusal plane appear to provide optimal bone thickness and stability.
- 1 June 2026
- Published by Wolters Kluwer Health in Dental Research Journal
- Vol. 23 (6)
Open AccessAssessment of infra-zygomatic area for ideal placement of miniscrews: A systematic review and meta-analysis
Background: The infrazygomatic crest (IZC) is a commonly used extra-alveolar site for orthodontic miniscrew placement because of its favorable anatomical position and relatively dense cortical bone. However, variations in bone thickness, insertion height, and angulation can influence the stability and success of miniscrew placement. To systematically evaluate and synthesize the available evidence on the infrazygomatic crest region to determine the most suitable site, insertion height, and angulation for orthodontic miniscrew placement. Materials and Methods: A systematic search was conducted across PubMed, Embase, Web of Science, Scopus, the Cochrane Library, and grey literature sources including Google Scholar and OpenGrey for studies published up to March 2023. Studies assessing cortical bone thickness and anatomical characteristics of the IZC relevant to miniscrew placement were included. Thirteen studies met the inclusion criteria for qualitative synthesis, and nine studies providing quantitative data were included in the meta-analysis. Mean values and standard deviations of bone thickness and insertion height along the distobuccal root of the maxillary first molar at 70° angulation were extracted. Forest plots were generated to compare findings across studies. Risk of bias was assessed using the Quality Assessment of Measurement Accuracy Studies (QUAMAS) tool. Results: Among the included studies, most reported adequate bone thickness in the region buccal to the maxillary first molar. Meta-analysis indicated that sufficient bone thickness is generally observed when miniscrews are inserted at an angulation of approximately 60°-70°. The optimal insertion height was commonly reported between 10 and 15 mm above the occlusal plane, where greater cortical bone thickness was observed. Increasing insertion angulation and decreasing insertion height were associated with improved bone engagement and primary stability. Conclusion: The current evidence suggests that the region buccal to the maxillary first molar in the infrazygomatic crest is the most favorable site for orthodontic miniscrew placement. An insertion angle of approximately 60°-70° and a height of 10-15 mm above the occlusal plane appear to provide optimal bone thickness and stability.
- 14 October 2025
- Published by SAGE Publications in Journal of Advanced Oral Research
- Vol. 16 (2) , 166-178
Assessment of Mandibular Buccal Shelf Area for Ideal Placement of Miniscrews: A Systematic Review and Meta-analysis
Aim: To determine the most favorable site for placing mini-implants within the mandibular buccal shelf (MBS) by evaluating buccal bone width and cortical bone thickness. Background: This review sought to analyze the MBS using cone-beam computed tomography (CBCT) data from diverse populations, including Caucasian, Asian, and South Asian adolescents and adults. Comparisons were made across potential insertion zones buccal to the first and second molars, with specific attention to the mesiobuccal and distobuccal aspects. The primary outcomes were buccal bone width, cortical thickness, and insertion angulation relevant to achieving predictable miniscrew stability. Materials and Methods: Conducted in accordance with PRISMA guidelines, the review protocol was registered on PROSPERO (CRD42021258738). A systematic search of PubMed, Embase, Web of Science, and Cochrane databases, supplemented by hand searching, identified 878 records. Eligible studies included randomized controlled trials and observational designs that reported MBS dimensions for miniscrew placement. Data were extracted on bone width, cortical thickness, and insertion angle. Quantitative synthesis was carried out using R statistical software, and study quality was evaluated with the QUAMAS tool. Results: Eight studies with comparable data were meta-analyzed. Significance was set at 0.05 for comparisons of bone width and cortical thickness. Risk-of-bias assessment identified nine studies as high quality and five as moderate. Findings consistently indicated the distobuccal cusp region of the mandibular second molar as the most favorable insertion site, followed by the mesiobuccal cusp area. Despite methodological differences across included studies, pooled analysis revealed significant differences ( p < .05) among sites, with the second molar region demonstrating superior dimensions for achieving miniscrew stability. Conclusion: The MBS adjacent to the distobuccal cusp of the second molar provides the most advantageous bone morphology for miniscrew placement, offering greater buccal bone width and cortical thickness. This location supports enhanced stability and should be considered the preferred choice for orthodontic anchorage in clinical practice.
- 14 October 2025
- Published by SAGE Publications in Journal of Advanced Oral Research
- Vol. 16 (2) , 166-178
Assessment of Mandibular Buccal Shelf Area for Ideal Placement of Miniscrews: A Systematic Review and Meta-analysis
Aim: To determine the most favorable site for placing mini-implants within the mandibular buccal shelf (MBS) by evaluating buccal bone width and cortical bone thickness. Background: This review sought to analyze the MBS using cone-beam computed tomography (CBCT) data from diverse populations, including Caucasian, Asian, and South Asian adolescents and adults. Comparisons were made across potential insertion zones buccal to the first and second molars, with specific attention to the mesiobuccal and distobuccal aspects. The primary outcomes were buccal bone width, cortical thickness, and insertion angulation relevant to achieving predictable miniscrew stability. Materials and Methods: Conducted in accordance with PRISMA guidelines, the review protocol was registered on PROSPERO (CRD42021258738). A systematic search of PubMed, Embase, Web of Science, and Cochrane databases, supplemented by hand searching, identified 878 records. Eligible studies included randomized controlled trials and observational designs that reported MBS dimensions for miniscrew placement. Data were extracted on bone width, cortical thickness, and insertion angle. Quantitative synthesis was carried out using R statistical software, and study quality was evaluated with the QUAMAS tool. Results: Eight studies with comparable data were meta-analyzed. Significance was set at 0.05 for comparisons of bone width and cortical thickness. Risk-of-bias assessment identified nine studies as high quality and five as moderate. Findings consistently indicated the distobuccal cusp region of the mandibular second molar as the most favorable insertion site, followed by the mesiobuccal cusp area. Despite methodological differences across included studies, pooled analysis revealed significant differences ( p < .05) among sites, with the second molar region demonstrating superior dimensions for achieving miniscrew stability. Conclusion: The MBS adjacent to the distobuccal cusp of the second molar provides the most advantageous bone morphology for miniscrew placement, offering greater buccal bone width and cortical thickness. This location supports enhanced stability and should be considered the preferred choice for orthodontic anchorage in clinical practice.
- Open Access
- 27 June 2023
- Published by Universidad Tecnica de Manabi in International journal of health sciences
- Vol. 7 (S1) , 1737-1747
Electroanalysis of nickel ions released in artificial saliva from three orthodontic arch wires: Stainless Steel (SS), NiTi, and CuNiTi
Background: Nickel titanium wires are superior for first alignment because they have exceptional shape memory and super-elasticity. Increased concerns have been raised about the high rate of nickel (Ni) allergy and the growing usage of dental biomaterials that contain Ni. Aim: The aim of the study was to analyze and evaluate the rate of nickel release from different types of orthodontic arch wires. Materials and methods: A set of arch wires of nickel titanium (NiTi), SS and Cu-NiTi were immersed in artificial saliva for three days and analyzed after three days. The amount of Ni ions released from the sample were evaluated using electrochemical techniques such as Cyclic Voltammetry (CV), Electrochemical Impedance Spectroscopy (EIS) and polarization (Tafel) plot. Results: The EIS and Tafel graph confirmed the s-NiTi, s-CuNiTi showed an excellent corrosion resistance than the s-SS. From all the above measurements, we can conclude that the saliva can affect the corrosion resistance property of the SS, NiTi, CuNiTi day by day. Conclusion: From this study it was concluded that the saliva can affect the corrosion resistance property of the SS, NiTi, CuNiTi day by day, and there was nickel ion release but at a very negligible rate.
- 27 June 2023
- Published by Universidad Tecnica de Manabi in International journal of health sciences
- Vol. 7 (S1) , 1737-1747
Open AccessElectroanalysis of nickel ions released in artificial saliva from three orthodontic arch wires: Stainless Steel (SS), NiTi, and CuNiTi
Background: Nickel titanium wires are superior for first alignment because they have exceptional shape memory and super-elasticity. Increased concerns have been raised about the high rate of nickel (Ni) allergy and the growing usage of dental biomaterials that contain Ni. Aim: The aim of the study was to analyze and evaluate the rate of nickel release from different types of orthodontic arch wires. Materials and methods: A set of arch wires of nickel titanium (NiTi), SS and Cu-NiTi were immersed in artificial saliva for three days and analyzed after three days. The amount of Ni ions released from the sample were evaluated using electrochemical techniques such as Cyclic Voltammetry (CV), Electrochemical Impedance Spectroscopy (EIS) and polarization (Tafel) plot. Results: The EIS and Tafel graph confirmed the s-NiTi, s-CuNiTi showed an excellent corrosion resistance than the s-SS. From all the above measurements, we can conclude that the saliva can affect the corrosion resistance property of the SS, NiTi, CuNiTi day by day. Conclusion: From this study it was concluded that the saliva can affect the corrosion resistance property of the SS, NiTi, CuNiTi day by day, and there was nickel ion release but at a very negligible rate.
- 9 June 2023
- Published by Wiley in Orthodontics & Craniofacial Research
- Vol. 27 (1) , 33-43
Comparison of treatment effects during en‐masse retraction of upper anterior teeth placed using mini‐implants placed at infrazygomatic crest and interradicular sites: A randomized controlled trial
Introduction: The objective of this prospective study was to examine the efficacy of posterior interradicular and infrazygomatic crest mini‐implants for en‐masse anterior retraction.Methods: The 22 patients were divided into two groups. In group 1 (IZC n = 11), mini‐implants were placed in the infrazygomatic crests and in group 2 (IR, n = 11), mini‐implants were placed in the molar‐premolar interradicular sites. Soft tissue, skeletal, and dental treatment effects between two groups were compared using lateral cephalometric measurements.Results: The average angle between the cranial base and A point was 1.01 degrees (P = .004), and the linear distance between the upper incisor and A point was 2.67 to 5.2 millimetres (P = .00). In IZC group the maxillary incisor to the palatal plane moved upward by a mean of −5.20 mm (P = .059), whereas in IR group the incisor movement changed by −2.67 mm (P = .068). There was no significant difference between groups IZC and IR while comparing overall treatment changes on upper incisor position change, angle, and overjet.Conclusions: Mini‐implants placed in between the molar and premolar as well as the infrazygomatic crest can withstand the deepening of the bite during retraction. Mini‐implants in IZC are capable of causing intrusion of the anterior teeth and preventing intrusion of the molars, thereby providing absolute anchoring in all planes. Placement of the mini‐implants in the infrazygomatic crest resulted in more linear retraction.
- 9 June 2023
- Published by Wiley in Orthodontics & Craniofacial Research
- Vol. 27 (1) , 33-43
Comparison of treatment effects during en‐masse retraction of upper anterior teeth placed using mini‐implants placed at infrazygomatic crest and interradicular sites: A randomized controlled trial
Introduction: The objective of this prospective study was to examine the efficacy of posterior interradicular and infrazygomatic crest mini‐implants for en‐masse anterior retraction.Methods: The 22 patients were divided into two groups. In group 1 (IZC n = 11), mini‐implants were placed in the infrazygomatic crests and in group 2 (IR, n = 11), mini‐implants were placed in the molar‐premolar interradicular sites. Soft tissue, skeletal, and dental treatment effects between two groups were compared using lateral cephalometric measurements.Results: The average angle between the cranial base and A point was 1.01 degrees (P = .004), and the linear distance between the upper incisor and A point was 2.67 to 5.2 millimetres (P = .00). In IZC group the maxillary incisor to the palatal plane moved upward by a mean of −5.20 mm (P = .059), whereas in IR group the incisor movement changed by −2.67 mm (P = .068). There was no significant difference between groups IZC and IR while comparing overall treatment changes on upper incisor position change, angle, and overjet.Conclusions: Mini‐implants placed in between the molar and premolar as well as the infrazygomatic crest can withstand the deepening of the bite during retraction. Mini‐implants in IZC are capable of causing intrusion of the anterior teeth and preventing intrusion of the molars, thereby providing absolute anchoring in all planes. Placement of the mini‐implants in the infrazygomatic crest resulted in more linear retraction.
- 1 January 2023
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 24 (12) , 944-950
Assessment of Toxicity of Green Synthesized Silver Nanoparticle-coated Titanium Mini-implants with Uncoated Mini-implants: Comparison in an Animal Model Study
To assess the potential for systemic toxicity when silver nanoparticle-coated mini-implants were implanted in Wistar albino rats conducted as a comparative study in the animal model by assessing the blood biochemistry, liver and kidney function, and histology of the implanted site. The surface of the mini-implant was coated with a green-mediated silver nanoparticle. Uncoated mini-implants were placed in two groups of eight Wistar albino rats, and silver nanoparticle-coated mini-implants were placed in another eight rats. The bone's general conditions, blood biochemistry assessing for ALT, AST, GPT, GOT, and histological sections using H and E stain and Masson's Trichrome stain were examined at 7, 14, and 28-day intervals. The creatinine, urea, ALP, and ALT showed no signs of systemic toxicity during the 28-day follow-up period in the Wistar rats both in the test and control groups. The histological evaluation, which was conducted using HE and MTS stain, revealed osteogenesis and adequate healing of the insertion site in the group where coated mini-implant was placed. The bone sample revealed no abnormalities in the control group with uncoated mini-implants. Green synthesized silver nanoparticle-coated mini-implant does not cause systemic toxicity as indicated by no abnormalities in the levels of creatinine, urea, ALT, ALP, GPT, and GOT. The bone histology indicates that the coated mini-implants placed in animal bone healed with adequate osteogenesis. Silver nanoparticles have potential for antimicrobial activity. Mini-implants placed as temporary anchorage devices in orthodontics often fail due to inflammation and plaque. Silver nanoparticle-coated mini-implants would reduce the risk of mini-implant failure as it would have antimicrobial potential and eliminate this cause for failure of mini-implants. How to cite this article: Sreenivasagan S, Subramanian AK, Mohanraj KG, et al. Assessment of Toxicity of Green Synthesized Silver Nanoparticle-coated Titanium Mini-implants with Uncoated Mini-implants: Comparison in an Animal Model Study. J Contemp Dent Pract 2023;24(12):944-950.
- 1 January 2023
- Published by Jaypee Brothers Medical Publishing in The Journal of Contemporary Dental Practice
- Vol. 24 (12) , 944-950
Assessment of Toxicity of Green Synthesized Silver Nanoparticle-coated Titanium Mini-implants with Uncoated Mini-implants: Comparison in an Animal Model Study
To assess the potential for systemic toxicity when silver nanoparticle-coated mini-implants were implanted in Wistar albino rats conducted as a comparative study in the animal model by assessing the blood biochemistry, liver and kidney function, and histology of the implanted site. The surface of the mini-implant was coated with a green-mediated silver nanoparticle. Uncoated mini-implants were placed in two groups of eight Wistar albino rats, and silver nanoparticle-coated mini-implants were placed in another eight rats. The bone's general conditions, blood biochemistry assessing for ALT, AST, GPT, GOT, and histological sections using H and E stain and Masson's Trichrome stain were examined at 7, 14, and 28-day intervals. The creatinine, urea, ALP, and ALT showed no signs of systemic toxicity during the 28-day follow-up period in the Wistar rats both in the test and control groups. The histological evaluation, which was conducted using HE and MTS stain, revealed osteogenesis and adequate healing of the insertion site in the group where coated mini-implant was placed. The bone sample revealed no abnormalities in the control group with uncoated mini-implants. Green synthesized silver nanoparticle-coated mini-implant does not cause systemic toxicity as indicated by no abnormalities in the levels of creatinine, urea, ALT, ALP, GPT, and GOT. The bone histology indicates that the coated mini-implants placed in animal bone healed with adequate osteogenesis. Silver nanoparticles have potential for antimicrobial activity. Mini-implants placed as temporary anchorage devices in orthodontics often fail due to inflammation and plaque. Silver nanoparticle-coated mini-implants would reduce the risk of mini-implant failure as it would have antimicrobial potential and eliminate this cause for failure of mini-implants. How to cite this article: Sreenivasagan S, Subramanian AK, Mohanraj KG, et al. Assessment of Toxicity of Green Synthesized Silver Nanoparticle-coated Titanium Mini-implants with Uncoated Mini-implants: Comparison in an Animal Model Study. J Contemp Dent Pract 2023;24(12):944-950.
- 1 September 2021
- Published by Elsevier in International Orthodontics
- Vol. 19 (3) , 471-479
CBCT comparison of buccal shelf bone thickness in adult Dravidian population at various sites, depths and angulation – A retrospective study
- 1 September 2021
- Published by Elsevier in International Orthodontics
- Vol. 19 (3) , 471-479
CBCT comparison of buccal shelf bone thickness in adult Dravidian population at various sites, depths and angulation – A retrospective study
- Open Access
- 1 January 2021
- Published by Wiley in BioMed Research International
- Vol. 2021 (1)
Pain Perception Associated with Mini‐Implants and Interventions for Pain Management: A Cross‐Sectional Questionnaire‐Based Survey
Background. Orthodontists use mini‐implants temporarily as an effective mode of skeletal anchorage devices. The placement of mini‐implants can cause pain and discomfort to the patients. Patients often develop swelling, and the pain could interfere with their daily activities. Practitioners tend to prescribe antibiotics and pain medication for management. Objectives. The main objectives of this study are to evaluate the pain perception and discomfort due to mini‐implant placement experienced by the patient and evaluate the interventions for pain management commonly practiced among orthodontists. Materials and Methods. The study was designed as a questionnaire‐based cross‐sectional study. A total of 271 patients were assessed, for whom 625 mini‐implants (ranging from 1.2 to 2 mm diameter and length 8‐14 mm) were placed. Pain scores were assessed using the VAS and the “Faces” pain rating scale to collect data about discomfort in daily activity and function. Data was collected from 244 patients. A total of 155 orthodontists were questioned regarding the prescription of medications and the interventions for managing pain and adverse effects. Results. Average pain score among female subjects was 16.71 and among men was 13.5. The highest pain scores were recorded for palatal mini‐implants with an average score of 36.29 and the least for interradicular mini‐implants with an average score of 9.02. Among the subjects, 47.9% of them took analgesics, and the most commonly prescribed analgesics were paracetamol (39%). Swelling at the site is where the mini‐implants were placed, and ulceration due to implants were commonly dealt with the excision of the surrounding soft tissue, composite placement, and palliative care with oral analgesic gels. Conclusion. Female subjects had more mini‐implants placed, and female subjects had also given more pain scores than their male counterparts. Palatal mini‐implants caused the highest pain, followed by mini‐implants placed at the infrazygomatic crest and the buccal shelf region. Palatal mini‐implants caused maximum discomfort during speech and eating, followed by the mini‐implant in the buccal shelf and the infrazygomatic crest region that also caused difficulty in yawning and laughing. Infiltration anesthesia was commonly given for the placement of interradicular implants and extra‐alveolar mini‐implants. Paracetamol was the most prescribed by the orthodontists, and more than half the doctors did not regularly prescribe antibiotics.
- 1 January 2021
- Published by Wiley in BioMed Research International
- Vol. 2021 (1)
Open AccessPain Perception Associated with Mini‐Implants and Interventions for Pain Management: A Cross‐Sectional Questionnaire‐Based Survey
Background. Orthodontists use mini‐implants temporarily as an effective mode of skeletal anchorage devices. The placement of mini‐implants can cause pain and discomfort to the patients. Patients often develop swelling, and the pain could interfere with their daily activities. Practitioners tend to prescribe antibiotics and pain medication for management. Objectives. The main objectives of this study are to evaluate the pain perception and discomfort due to mini‐implant placement experienced by the patient and evaluate the interventions for pain management commonly practiced among orthodontists. Materials and Methods. The study was designed as a questionnaire‐based cross‐sectional study. A total of 271 patients were assessed, for whom 625 mini‐implants (ranging from 1.2 to 2 mm diameter and length 8‐14 mm) were placed. Pain scores were assessed using the VAS and the “Faces” pain rating scale to collect data about discomfort in daily activity and function. Data was collected from 244 patients. A total of 155 orthodontists were questioned regarding the prescription of medications and the interventions for managing pain and adverse effects. Results. Average pain score among female subjects was 16.71 and among men was 13.5. The highest pain scores were recorded for palatal mini‐implants with an average score of 36.29 and the least for interradicular mini‐implants with an average score of 9.02. Among the subjects, 47.9% of them took analgesics, and the most commonly prescribed analgesics were paracetamol (39%). Swelling at the site is where the mini‐implants were placed, and ulceration due to implants were commonly dealt with the excision of the surrounding soft tissue, composite placement, and palliative care with oral analgesic gels. Conclusion. Female subjects had more mini‐implants placed, and female subjects had also given more pain scores than their male counterparts. Palatal mini‐implants caused the highest pain, followed by mini‐implants placed at the infrazygomatic crest and the buccal shelf region. Palatal mini‐implants caused maximum discomfort during speech and eating, followed by the mini‐implant in the buccal shelf and the infrazygomatic crest region that also caused difficulty in yawning and laughing. Infiltration anesthesia was commonly given for the placement of interradicular implants and extra‐alveolar mini‐implants. Paracetamol was the most prescribed by the orthodontists, and more than half the doctors did not regularly prescribe antibiotics.