Gaurav Gadodia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Gaurav Gadodia has a total of 35 co-authors. Here are the top co-authors by number of shared publications:
- Charles Martin
Department of Interventional Radiology, Cleveland Clinic, Cleveland, Ohio
5 shared publications - Crew Weunski
John Carroll University, Cleveland, OH
5 shared publications - Aydan Hanlon
Lerner Research Institute, Cleveland Clinic, Cleveland, OH
3 shared publications J. Yanof
Lerner Research Institute, Cleveland Clinic, Cleveland, OH
2 shared publicationsK. West
Lerner Research Institute, Cleveland Clinic, Cleveland, OH
2 shared publications- Michael Evans
MediView XR, Inc., Cleveland, OH, USA
2 shared publications
Latest Publications
- Open Access
- 15 September 2025
- Published by The Korean Society of Endo-Laparoscopic & Robotic Surgery in Journal of Minimally Invasive Surgery
- Vol. 28 (3) , 122-129
In-vivo evaluation of an augmented reality enhanced ultrasound needle guidance system for minimally invasive procedures in porcine models: a preclinical comparative study
Sanjit Datta, Robert F. Short, Jeffrey W. Milsom, Charles Martin III, Gaurav Gadodia, Gabrielle Stefy Bailey, Crew Weunski, Michael Evans, Bradley B. Pua. Journal of Minimally Invasive Surgery 2025;28:122-9. https://doi.org/10.7602/jmis.2025.28.3.122
- 15 September 2025
- Published by The Korean Society of Endo-Laparoscopic & Robotic Surgery in Journal of Minimally Invasive Surgery
- Vol. 28 (3) , 122-129
Open AccessIn-vivo evaluation of an augmented reality enhanced ultrasound needle guidance system for minimally invasive procedures in porcine models: a preclinical comparative study
Sanjit Datta, Robert F. Short, Jeffrey W. Milsom, Charles Martin III, Gaurav Gadodia, Gabrielle Stefy Bailey, Crew Weunski, Michael Evans, Bradley B. Pua. Journal of Minimally Invasive Surgery 2025;28:122-9. https://doi.org/10.7602/jmis.2025.28.3.122
- Open Access
- 15 February 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 11 (06) , 062602-10
Evaluation of an augmented reality navigational guidance platform for percutaneous procedures in a cadaver model
PurposeThe objective of this study is to review the accuracy of an augmented reality navigational guidance system designed to facilitate improved visualization, guidance, and accuracy during percutaneous needle-based procedures including biopsies and ablations.ApproachUsing the HoloLens 2, the system registers and projects 3D CT-based models of segmented anatomy along with live ultrasound, fused with electromagnetically tracked instruments including ultrasound probes and needles, giving the operator comprehensive stereoscopic visualization for intraoperative planning and navigation during procedures.Tracked needles were guided to targets implanted in a cadaveric model using the system. Image fusion registration error, the multimodality error measured as the post-registration distance between a corresponding point measured in the stereoscopic CT and tracked ultrasound coordinate systems, and target registration error, the Euclidean distance between needle tip and target after needle placement, were measured as registration and targeting accuracy metrics. A t-distribution was used for statistical analysis.ResultsThree operators performed 36 total needle passes, 18 to measure image fusion registration error and 18 to measure target registration error on four targets. The average depth of each needle pass was 8.4 cm from skin to target center. Mean IFRE was 4.4 mm (H0: μ=5 mm, P<0.05). Mean TRE was 2.3 mm (H0: μ=5 mm, P<0.00001).ConclusionsThe study demonstrated high registration and targeting accuracy of this AR navigational guidance system in percutaneous, needle-based procedures. This suggests the ability to facilitate improved clinical performance in percutaneous procedures such as ablations and biopsies.
- 15 February 2024
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 11 (06) , 062602-10
Open AccessEvaluation of an augmented reality navigational guidance platform for percutaneous procedures in a cadaver model
PurposeThe objective of this study is to review the accuracy of an augmented reality navigational guidance system designed to facilitate improved visualization, guidance, and accuracy during percutaneous needle-based procedures including biopsies and ablations.ApproachUsing the HoloLens 2, the system registers and projects 3D CT-based models of segmented anatomy along with live ultrasound, fused with electromagnetically tracked instruments including ultrasound probes and needles, giving the operator comprehensive stereoscopic visualization for intraoperative planning and navigation during procedures.Tracked needles were guided to targets implanted in a cadaveric model using the system. Image fusion registration error, the multimodality error measured as the post-registration distance between a corresponding point measured in the stereoscopic CT and tracked ultrasound coordinate systems, and target registration error, the Euclidean distance between needle tip and target after needle placement, were measured as registration and targeting accuracy metrics. A t-distribution was used for statistical analysis.ResultsThree operators performed 36 total needle passes, 18 to measure image fusion registration error and 18 to measure target registration error on four targets. The average depth of each needle pass was 8.4 cm from skin to target center. Mean IFRE was 4.4 mm (H0: μ=5 mm, P<0.05). Mean TRE was 2.3 mm (H0: μ=5 mm, P<0.00001).ConclusionsThe study demonstrated high registration and targeting accuracy of this AR navigational guidance system in percutaneous, needle-based procedures. This suggests the ability to facilitate improved clinical performance in percutaneous procedures such as ablations and biopsies.
- 24 February 2022
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 33 (3) , 333-338
Early Clinical Feasibility Evaluation of an Augmented Reality Platform for Guidance and Navigation during Percutaneous Tumor Ablation
- 24 February 2022
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 33 (3) , 333-338
Early Clinical Feasibility Evaluation of an Augmented Reality Platform for Guidance and Navigation during Percutaneous Tumor Ablation
- 1 December 2021
- Published by Springer Nature
- p. 277-302
Renovascular Hypertension
- Open Access
- 1 March 2020
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 31 (3) , S135-S136
4:03 PM Abstract No. 297 True three-dimensional holographic visualization for performance of percutaneous thermal ablation of solid liver tumors: an update on in-human evaluation
- 1 March 2020
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 31 (3) , S135-S136
Open Access4:03 PM Abstract No. 297 True three-dimensional holographic visualization for performance of percutaneous thermal ablation of solid liver tumors: an update on in-human evaluation
- Open Access
- 1 March 2020
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 31 (3) , S212-S213
Abstract No. 480 Real-time, fused holographic visualization for performing percutaneous thermal ablation of solid liver tumors: preliminary feasibility evaluation
- 1 March 2020
- Published by Elsevier in Journal of Vascular and Interventional Radiology
- Vol. 31 (3) , S212-S213
Open AccessAbstract No. 480 Real-time, fused holographic visualization for performing percutaneous thermal ablation of solid liver tumors: preliminary feasibility evaluation
- Open Access
- 1 June 2019
- Published by Wiley in Journal of Pediatric Gastroenterology and Nutrition
- Vol. 68 (6) , 788-792
Hepatic Venous Pressure Gradient Measurements in Children
Objectives: In adults, elevated hepatic venous pressure gradients (HVPGs) are correlated with the degree of liver fibrosis on histopathology and predict worse outcomes including variceal bleeding and death. We aimed to examine the association between HVPG measurements, histopathologic findings, and clinical indicators of portal hypertension in children.Methods: Utilizing retrospective data from 2 pediatric centers between 2006 and 2015, we identified children who underwent simultaneous HVPG measurement and transjugular liver biopsy. Medical charts were reviewed for histopathology, imaging, endoscopic, and clinical data.Results: Forty‐one children (median age 11 years) were included in the analysis with diagnoses of acute hepatitis (n = 15), chronic liver disease (n = 12), hepatic noncirrhotic portal hypertension (n = 4), acute liver failure (n = 3), and nonhepatic causes of portal hypertension (n = 7). Elevated mean HVPG measurements were found in children with acute liver failure (10 mmHg, range 4–12) and chronic liver disease (7 mmHg, range 1–12). HVPG measurements did not correlate with the histological severity of fibrosis (ρ = 0.23, P = 0.14) or portal inflammation (ρ = 0.24, P = 0.29), and no difference was found in HVPG when comparing children with and without a history of variceal bleeding (P = 0.43).Conclusions: HVPG measurements do not correlate significantly with the degree of hepatic fibrosis on biopsy. Furthermore, HVPG measurements are not associated with the presence of varices or history of variceal bleeding, suggesting the possibility of intrahepatic shunting in children with advanced liver disease. Therefore, unlike in adults, HVPG measurements may not accurately predict children who are at risk of complications from portal hypertension.
- 1 June 2019
- Published by Wiley in Journal of Pediatric Gastroenterology and Nutrition
- Vol. 68 (6) , 788-792
Open AccessHepatic Venous Pressure Gradient Measurements in Children
Objectives: In adults, elevated hepatic venous pressure gradients (HVPGs) are correlated with the degree of liver fibrosis on histopathology and predict worse outcomes including variceal bleeding and death. We aimed to examine the association between HVPG measurements, histopathologic findings, and clinical indicators of portal hypertension in children.Methods: Utilizing retrospective data from 2 pediatric centers between 2006 and 2015, we identified children who underwent simultaneous HVPG measurement and transjugular liver biopsy. Medical charts were reviewed for histopathology, imaging, endoscopic, and clinical data.Results: Forty‐one children (median age 11 years) were included in the analysis with diagnoses of acute hepatitis (n = 15), chronic liver disease (n = 12), hepatic noncirrhotic portal hypertension (n = 4), acute liver failure (n = 3), and nonhepatic causes of portal hypertension (n = 7). Elevated mean HVPG measurements were found in children with acute liver failure (10 mmHg, range 4–12) and chronic liver disease (7 mmHg, range 1–12). HVPG measurements did not correlate with the histological severity of fibrosis (ρ = 0.23, P = 0.14) or portal inflammation (ρ = 0.24, P = 0.29), and no difference was found in HVPG when comparing children with and without a history of variceal bleeding (P = 0.43).Conclusions: HVPG measurements do not correlate significantly with the degree of hepatic fibrosis on biopsy. Furthermore, HVPG measurements are not associated with the presence of varices or history of variceal bleeding, suggesting the possibility of intrahepatic shunting in children with advanced liver disease. Therefore, unlike in adults, HVPG measurements may not accurately predict children who are at risk of complications from portal hypertension.
- 1 March 2018
- Published by Wolters Kluwer Health in The Neurologist
- Vol. 23 (2) , 67-70
Frequency of and Factors Associated With Obstructive Sleep Apnea and Periodic Limb Movements in Stroke and TIA Patients
Introduction: Obstructive sleep apnea (OSA) and periodic limb movements (PLMs) have been associated with an increased risk of cardiovascular disease. There is limited data on the relationship between OSA and PLMs with atrial fibrillation and resistant hypertension in stroke and transient ischemic attack (TIA) patients. Methods: Consecutive stroke and TIA patients referred by a vascular neurologist for diagnostic polysomnography (PSG) from September 1, 2012 to August 31, 2015 were included in a retrospective analysis. Baseline clinical characteristics, PSG results and outcomes were collected to identify the frequency of and factors associated with PLMs (mild 5 to 10/h; severe ≥15/h), PLM arousals (≥5/h) and moderate-severe OSA (apna-hypopnea Index ≥15) including atrial fibrillation and resistant hypertension. Results: Among 103 patients (mean age, 60±15 y; 50% female; 61% nonwhites; 77% ischemic stroke; 23% resistant hypertension) who underwent PSG, 20% had mild PLMs, 28% had severe PLMs, 14% had PLM arousals, and 22% had moderate-severe OSA. Factors associated with moderate-severe OSA included older age (odds ratio, 1.06; 95% confidence interval, 1.02-1.11) and presence of atrial fibrillation (odds ratio, 4.26; 95% confidence interval, 1.17-15.44). Nonwhite race was associated with lower likelihood of mild and severe PLMs, whereas female sex was associated with lower likelihood of PLM arousals. OSA and PLMs were not associated with resistant hypertension. Conclusions: A significant number of stroke and TIA patients who underwent PSG have PLMs and moderate-severe OSA. Stroke and TIA patients with atrial fibrillation are more likely to have moderate-severe OSA and may benefit from PSG evaluation.
- 1 March 2018
- Published by Wolters Kluwer Health in The Neurologist
- Vol. 23 (2) , 67-70
Frequency of and Factors Associated With Obstructive Sleep Apnea and Periodic Limb Movements in Stroke and TIA Patients
Introduction: Obstructive sleep apnea (OSA) and periodic limb movements (PLMs) have been associated with an increased risk of cardiovascular disease. There is limited data on the relationship between OSA and PLMs with atrial fibrillation and resistant hypertension in stroke and transient ischemic attack (TIA) patients. Methods: Consecutive stroke and TIA patients referred by a vascular neurologist for diagnostic polysomnography (PSG) from September 1, 2012 to August 31, 2015 were included in a retrospective analysis. Baseline clinical characteristics, PSG results and outcomes were collected to identify the frequency of and factors associated with PLMs (mild 5 to 10/h; severe ≥15/h), PLM arousals (≥5/h) and moderate-severe OSA (apna-hypopnea Index ≥15) including atrial fibrillation and resistant hypertension. Results: Among 103 patients (mean age, 60±15 y; 50% female; 61% nonwhites; 77% ischemic stroke; 23% resistant hypertension) who underwent PSG, 20% had mild PLMs, 28% had severe PLMs, 14% had PLM arousals, and 22% had moderate-severe OSA. Factors associated with moderate-severe OSA included older age (odds ratio, 1.06; 95% confidence interval, 1.02-1.11) and presence of atrial fibrillation (odds ratio, 4.26; 95% confidence interval, 1.17-15.44). Nonwhite race was associated with lower likelihood of mild and severe PLMs, whereas female sex was associated with lower likelihood of PLM arousals. OSA and PLMs were not associated with resistant hypertension. Conclusions: A significant number of stroke and TIA patients who underwent PSG have PLMs and moderate-severe OSA. Stroke and TIA patients with atrial fibrillation are more likely to have moderate-severe OSA and may benefit from PSG evaluation.