LXLiuwei Xu

Liuwei Xu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Liuwei Xu has a total of 28 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

    • 20 November 2026
    • Published by MDPI AG in Atmosphere
      • Vol. 17  (11) , 1154
      • https://doi.org/10.3390/atmos17111154
    Open Access

    Nuclear Accident Consequence Assessment System Based on Web GIS

    by Pu Zhu, Rubing Xue, Liuwei Xu

    Accident consequence assessment supports nuclear emergency planning by linking atmospheric dispersion and dose calculations to geographic information. This study develops a browser/server web-GIS system that integrates a CALPUFF modeling workflow, dose assessment, map visualization, and spatial queries. An illustrative Fukushima Daiichi Nuclear Power Plant (FDNPP)-based scenario is used to examine 131I dispersion over a 15 h calculation period. At seven downwind locations spanning 4–28 km, relative differences from RASCAL range from −47.46% to +141.19%, and six of the seven concentration pairs are within a factor of two. Agreement is closer at 12–28 km than at the two nearest receptors. The case demonstrates the integrated modeling and GIS workflow, including concentration mapping, dose queries, and planning-buffer display. The comparison characterizes agreement between the models over the evaluated 4–28 km range.

  • Improved Static Capacity Configuration for Hybrid Power Supply Scheme With Energy Storage Based on NSGA in Tokamak

    by Yunxiang Tian, Yanan Wu, Jing Lu, Jun Li, Liuwei Xu, Yang Zhang, Pengfei Wang, Huafeng Mao

    Power impact frequently occurs during operation of shock loads, such as fusion devices, threatening the stable operation of the power system. Meanwhile, both short-time high pulse and long-time steady power exist, which have distinct time scales and amplitude characteristics. Currently, the capacity of power supply system is designed according to the maximum impulse power, causing the large redundancy and high cost. Aiming at this issue, hybrid power supply scheme based on energy storage technology with high power density provides a potential approach. However, little research focuses on the reasonable static configuration for different type of power supply. This paper presents the non-dominated sorting genetic algorithm (NSGA) algorithm to divide the two kinds of power, where impulse power can be treated by high-density energy storage and stable power is sustained by substation devices. In specific, taking the static investment and dynamic response of energy storage as the objectives, the critical optimal power can be determined. Finally, power scenario based on a typical Tokamak fusion device, international thermos-nuclear experimental reactor (ITER), is applied as case study of the proposed algorithm. The results show that the obtained crucial power can reasonably decrease the static capacity for substation to achieve the optimal economy and satisfy the mentioned objectives, providing the basis for other static capacity allocation circumstances and assisting accurate and high-efficiency smart control for power converters.


  • Open Access

    Research on a Novel Hybrid Power Supply Scheme with Energy Storage Technology for Tokamak

    by Yunxiang Tian, Yanan Wu, Jing Lu, Liuwei Xu, Pengfei Wang, Jun Li, Rui He

    Megawatt-impulse power generated by Tokamak fusion devices seriously threats to the stable operation of the whole system. The current power supply scheme needs to leave large redundancy to suffer such a huge power impact, resulting in a high cost of the power supply system. Moreover, no reasonable configuration for impulse power and stable power causes unnecessary waste of power supply capacity. The rapid development of energy storage technology provides a potential approach to solve the operation stability problem caused by large amounts of power impact. Thus, a novel hybrid power supply scheme is creatively put forward with centralized energy storage, which can effectively decrease the voltage level of the grid and achieve smooth connection into the public grid when validly compensating for the impulse power. The cost evaluation model and principles are proposed to analyze and assess the economic advantages of the hybrid power supply scheme with centralized energy storage. Finally, a power scenario based on the international thermosnuclear experimental reactor (ITER) is applied as a case study of the cost evaluation model for various schemes, and the results verify that the novel hybrid power supply scheme has benefits on economics and the capacity of the grid over other schemes.


  • Conceptual Design of the Power Supply System for the CFETR CS Model Coil

    by Yuanyuan Ma, Yu Wu, Liuwei Xu, Huajun Liu, Yanan Wu

    The central solenoid (CS) model coil (CSMC), which has a high stored energy, is developed to validate the CS manufacturing methods for the China Fusion Engineering Test Reactor (CFETR). The designed operation current of the model coil is 47.65 kA. The maximum rate of the magnetic field is 1.5 T/s. The stored energy of the model coil is 407.6 MJ. A set of verification test of the model coil will be conducted after manufacture, so a CSMC power supply, which generates the current for coil operation, and a quench protection, which could quickly release the stored energy, are required. The main circuit topology of power supply was designed according to the requirements of the testing current waveform. The current control was adopted, which controlled the actual output current provided by the power supply system to track any specified current reference of the model coil within acceptable precision. The design of the quench protection system for model coil was also described in this paper.


  • Quench Protection of the Central Solenoid Model Coil for the CFETR

    by Yuanyuan Ma, Yu Wu, Liuwei Xu, Yanan Wu, Yanlan Hu, Teng Wang

    The China Fusion Engineering Test Reactor (CFETR) is a new tokamak device. The Central Solenoid (CS) model coil, which is responsible for developing and verifying the key manufacturing methods of a superconducting magnet, is now under engineering design. The rating current of the coil is 47.65 kA and total mag-netically stored energy reaches to 407 MJ, so a quench protection is required to discharge this huge stored energy. This paper gives a description of CS model coil quench protection. The circuit of quench protection system is designed, which consists of direct current circuit breaker (DCCB), discharge resistor, diode and fuse. The main parameters of these components were selected. The control system of quench protection is also introduced.


  • Operation Analysis and Improvement of Impulse Current Test on High-Power DC Test Platform With SVC System

    by Xudong Wang, Liuwei Xu, Peng Fu, Yanan Wu, Huafeng Mao, Jun Li

    The international thermonuclear experimental reactor poloidal field converter unit is comprised of four converter bridges, dc reactors, dc switches, etc., and most are nonstandard. To evaluate the performance of these equipments, a high-power dc test platform has been built to carry out the steady-state current test and impulse current test. The latter is significant to verify the fault suppression capability of products. The dc test platform can output the rated 400-kA impulse current. The principle design and structure of the dc test platform is introduced in this paper. The transient large current in impulse current test could cause huge impact reactive power and grid voltage sag. The impact is analyzed by theoretical calculation and simulation. A static var compensator system is added to suppress the transient effects of the reactive power. A predictive reactive power control strategy is proposed to improve the dynamic response. The comparisons with the traditional control demonstrate that the proposed control is effective in compensating impact reactive power and it also performs well on inhibiting the grid voltage sag.


  • Transient Fault Current Test for ITER DC Reactor on DC Test Platform in ASIPP

    by Xiuqing Zhang, Peng Fu, Ge Gao, Liuwei Xu, Zhiquan Song


  • Fault Current Tests for ITER External Bypass on DC Test Platform in ASIPP

    by Xiuqing Zhang, Peng Fu, Liuwei Xu, Ge Gao, Zhiquan Song


  • The design of quench protection of EAST toroidal field power supply system

    by Liuwei Xu, Xiaoning Liu, Jiafu Jiang, Yanchuan Liao