Bruno Lima Pessôa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bruno Lima Pessôa has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Adriano Oliveira Andrade
Federal University of Uberlândia
2 shared publications - Ariana Moura Cabral
Federal University of Uberlândia
2 shared publications - Camila Castelo Branco Pupe
Universidade Federal Fluminense, UFF
2 shared publications - Karina Lebeis Pires
Universidade Federal do Estado do Rio de Janeiro, Brasil
2 shared publications - Osvaldo Jose Moreira Nascimento
Universidade Federal Fluminense Niteroi Rio de Janeiro Brazil
2 shared publications - Adriano Alves Pereira
Universidade Federal de Uberlândia, Brasil
1 shared publication
Latest Publications
- 15 November 2023
- Published by Springer Nature in Neurosurgical Review
- Vol. 46 (1) , 1-11
Enhancing meningioma resection: a comprehensive study on the safety and effectiveness of Onyx™ presurgical embolization
Presurgical embolization (PE) has emerged as an interesting strategy to help turn brain tumor resection more amenable. This study aims to systematically review the safety and effectiveness of Onyx™ PE in meningioma resection. We followed Cochrane Collaboration and PRISMA for systematic review and meta-analysis, querying PUBMED, Cochrane Library, Web of Science, and Embase databases. Major complications were defined as other artery occlusion, visual deficits due to PE, or non temporary nerve damage, while minor included transitory conditions and others without clinical implications. A total of 186 patients were included, in which 120 were WHO grade I (80%), II (16%), and III (4%). Patient baseline characteristics and complications were distributed in groups without or with individual patient data analysis. Individual Patient Data Meta-Analysis (IPDMA) was performed on the last category, comprising 51 meningiomas that underwent Onyx™ PE. Among available data, 70%, 17%, and 13% were WHO grade I, II, and III, respectively. Considering all studies, tumor characteristics regarding grade underscored a certain homogeneity. Complications occurred at a rate of 9% (95% CI, 4 to 14%; I2 = 35%), with the rate of major complications significantly lower at only 1% (95% CI, 0 to 3%; I2 = 32%), whereas of minor complications was 7% (95% CI, 3 to 10%; I2 = 0%). Mean surgery blood loss was 668.7 (95% CI, 534.9 to 835.8; I2 = 0%) in IPDMA. Onyx™ PE is promising for safer surgical meningioma resection, despite limitations. Further studies are required to validate efficacy, enhance patient selection, and refine techniques.
- 15 November 2023
- Published by Springer Nature in Neurosurgical Review
- Vol. 46 (1) , 1-11
Enhancing meningioma resection: a comprehensive study on the safety and effectiveness of Onyx™ presurgical embolization
Presurgical embolization (PE) has emerged as an interesting strategy to help turn brain tumor resection more amenable. This study aims to systematically review the safety and effectiveness of Onyx™ PE in meningioma resection. We followed Cochrane Collaboration and PRISMA for systematic review and meta-analysis, querying PUBMED, Cochrane Library, Web of Science, and Embase databases. Major complications were defined as other artery occlusion, visual deficits due to PE, or non temporary nerve damage, while minor included transitory conditions and others without clinical implications. A total of 186 patients were included, in which 120 were WHO grade I (80%), II (16%), and III (4%). Patient baseline characteristics and complications were distributed in groups without or with individual patient data analysis. Individual Patient Data Meta-Analysis (IPDMA) was performed on the last category, comprising 51 meningiomas that underwent Onyx™ PE. Among available data, 70%, 17%, and 13% were WHO grade I, II, and III, respectively. Considering all studies, tumor characteristics regarding grade underscored a certain homogeneity. Complications occurred at a rate of 9% (95% CI, 4 to 14%; I2 = 35%), with the rate of major complications significantly lower at only 1% (95% CI, 0 to 3%; I2 = 32%), whereas of minor complications was 7% (95% CI, 3 to 10%; I2 = 0%). Mean surgery blood loss was 668.7 (95% CI, 534.9 to 835.8; I2 = 0%) in IPDMA. Onyx™ PE is promising for safer surgical meningioma resection, despite limitations. Further studies are required to validate efficacy, enhance patient selection, and refine techniques.
- Open Access
- 8 August 2022
- Published by FapUNIFESP (SciELO) in Arquivos de Neuro-Psiquiatria
- Vol. 80 (6) , 607-615
HIV-associated painful neuropathy: where are we?
Background: After the advent of combination antiretroviral therapy, infection with the human immunodeficiency virus (HIV) ceased to be a devastating disease, but sensory neuropathy resulting from the permanence of the virus and the side effects of treatment have worsened the morbidities of these patients. Objective: To investigate the quality of life of 64 HIV-positive patients: 24 with painful neuropathy (case group) and 40 without painful neuropathy (control group). The impact of other factors on quality of life was also assessed. Methods To assess painful neuropathy, the Leeds Assessment of Neuropathic Symptoms and Signs (LANSS) scale, Douleur Neuropathique 4 (DN4) questions and Neuropathy Disability Score (NDS) were used. The Short Form Health Survey (SF-36) scale was used to assess quality of life. Factors related or unrelated to HIV were obtained through the medical history and analysis on medical records. Results: The quality of life of patients with neuropathic pain was worse in six of the eight domains of the SF-36 scale. The number of clinical manifestations related to HIV, length of time with detectable viral load since diagnosis, length of time since the diagnosis of HIV infection and length of time of HAART use had a negative impact on quality of life. Higher levels of CD4, education and family income had a positive impact. Conclusions: Painful neuropathy related to HIV is a factor that worsens the quality of life of patients infected with this virus and should be included in the clinical evaluation.
- 8 August 2022
- Published by FapUNIFESP (SciELO) in Arquivos de Neuro-Psiquiatria
- Vol. 80 (6) , 607-615
Open AccessHIV-associated painful neuropathy: where are we?
Background: After the advent of combination antiretroviral therapy, infection with the human immunodeficiency virus (HIV) ceased to be a devastating disease, but sensory neuropathy resulting from the permanence of the virus and the side effects of treatment have worsened the morbidities of these patients. Objective: To investigate the quality of life of 64 HIV-positive patients: 24 with painful neuropathy (case group) and 40 without painful neuropathy (control group). The impact of other factors on quality of life was also assessed. Methods To assess painful neuropathy, the Leeds Assessment of Neuropathic Symptoms and Signs (LANSS) scale, Douleur Neuropathique 4 (DN4) questions and Neuropathy Disability Score (NDS) were used. The Short Form Health Survey (SF-36) scale was used to assess quality of life. Factors related or unrelated to HIV were obtained through the medical history and analysis on medical records. Results: The quality of life of patients with neuropathic pain was worse in six of the eight domains of the SF-36 scale. The number of clinical manifestations related to HIV, length of time with detectable viral load since diagnosis, length of time since the diagnosis of HIV infection and length of time of HAART use had a negative impact on quality of life. Higher levels of CD4, education and family income had a positive impact. Conclusions: Painful neuropathy related to HIV is a factor that worsens the quality of life of patients infected with this virus and should be included in the clinical evaluation.
- Open Access
- 14 November 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (15)
Inertial sensors in the motor assessment of Parkinson's Disease in patients who underwent Pallidotomy
Parkinson's Disease is a neurodegenerative disorder with a great global impact and, despite recent advances, it still needs improvement in the methods for assessing motor alterations. This study aimed at evaluating a system (hardware and software) capable of accurately quantifying tremor in patients with Parkinson's disease that underwent pallidotomy. The Mean Absolute Value (MAV) of the involuntary activity of three patients that underwent pallidotomy surgery - in the pre and postoperative scenarios- was evaluated. The Mean Absolute Value of involuntary activity obtained through the suggested device (TREMSEN) showed a good correlation with the clinical findings, as well as with the findings already described in previous studies. The present study showed that MAV alterations were always positively related to tremor, or negatively related to bradykinesia and rigidity, or possibly both. A tendency towards greater tremor influence on the MAV than bradykinesia and rigidity was also observed. The positive correlation among the values measured by the TREMSEN device and the patients´ clinical result opens doors for the future application of technology, such as accurate and objective assessment of motor disorders, continuous monitoring and remote monitoring.
- 14 November 2021
- Published by Research, Society and Development in Research, Society and Development
- Vol. 10 (15)
Open AccessInertial sensors in the motor assessment of Parkinson's Disease in patients who underwent Pallidotomy
Parkinson's Disease is a neurodegenerative disorder with a great global impact and, despite recent advances, it still needs improvement in the methods for assessing motor alterations. This study aimed at evaluating a system (hardware and software) capable of accurately quantifying tremor in patients with Parkinson's disease that underwent pallidotomy. The Mean Absolute Value (MAV) of the involuntary activity of three patients that underwent pallidotomy surgery - in the pre and postoperative scenarios- was evaluated. The Mean Absolute Value of involuntary activity obtained through the suggested device (TREMSEN) showed a good correlation with the clinical findings, as well as with the findings already described in previous studies. The present study showed that MAV alterations were always positively related to tremor, or negatively related to bradykinesia and rigidity, or possibly both. A tendency towards greater tremor influence on the MAV than bradykinesia and rigidity was also observed. The positive correlation among the values measured by the TREMSEN device and the patients´ clinical result opens doors for the future application of technology, such as accurate and objective assessment of motor disorders, continuous monitoring and remote monitoring.
- 19 October 2021
- Published by Springer Nature in Neurosurgical Review
- Vol. 45 (2) , 1123-1134
Prevalence of distinct types of hardware failures related to deep brain stimulation
Deep brain stimulation (DBS) is an effective treatment of several types of neurological conditions, including Parkinson’s disease, essential tremor, dystonia, and epilepsy. Despite technological progress in the past 10 years, the number of studies reporting side effects of DBS has increased, mainly due to hardware failures. This review investigated studies published between 2017 and 2021 to identify the prevalence of distinct types of hardware failures related to DBS. In total, fifteen studies were selected for the estimate of the prevalence of five distinct types of hardware failures: high impedance, fracture or failure of the lead or other parts of the implant, skin erosion and infection, lead malposition or migration, and implantable pulse generator (IPG) malfunction. The quality evaluation of the studies suggests a need to report results including populations from distinct regions of the world so that results can be generalized. The objective analysis of the prevalence of hardware failures showed that skin erosion and infection presented the highest prevalence in relation to other hardware failures. Despite the sophistication of the surgical technique of DBS over time, there is a considerable complication rate, about 7 per 100 individuals (\(\mathrm{prevalence}=6.67\%, CI = [2.26\%,12.49\%]\), in which CI is the confidence interval). Future research can also include correlation analysis with the aim of understanding the correlation between distinct hardware failures and variables such as gender, type of disorder, and age.- 19 October 2021
- Published by Springer Nature in Neurosurgical Review
- Vol. 45 (2) , 1123-1134
Prevalence of distinct types of hardware failures related to deep brain stimulation
Deep brain stimulation (DBS) is an effective treatment of several types of neurological conditions, including Parkinson’s disease, essential tremor, dystonia, and epilepsy. Despite technological progress in the past 10 years, the number of studies reporting side effects of DBS has increased, mainly due to hardware failures. This review investigated studies published between 2017 and 2021 to identify the prevalence of distinct types of hardware failures related to DBS. In total, fifteen studies were selected for the estimate of the prevalence of five distinct types of hardware failures: high impedance, fracture or failure of the lead or other parts of the implant, skin erosion and infection, lead malposition or migration, and implantable pulse generator (IPG) malfunction. The quality evaluation of the studies suggests a need to report results including populations from distinct regions of the world so that results can be generalized. The objective analysis of the prevalence of hardware failures showed that skin erosion and infection presented the highest prevalence in relation to other hardware failures. Despite the sophistication of the surgical technique of DBS over time, there is a considerable complication rate, about 7 per 100 individuals (\(\mathrm{prevalence}=6.67\%, CI = [2.26\%,12.49\%]\), in which CI is the confidence interval). Future research can also include correlation analysis with the aim of understanding the correlation between distinct hardware failures and variables such as gender, type of disorder, and age.- Open Access
- 1 June 2021
- Published by FapUNIFESP (SciELO) in Revista da Associação Médica Brasileira
- Vol. 67 (6) , 816-821
Lead-DBS: an additional tool for stereotactic surgery
OBJECTIVE: Use Lead-DBS software to analyze stereotactical surgical outcome of an operated population and demonstrate that small target deviations do not compromise the stimulation of desired structures, even with small amperages. METHODS: Image exams of patients submitted to deep brain stimulation for movement disorders treatment were processed in Lead-DBS software. Electrode stereotactic coordinates were subtracted from the planned target and those deviations, compared among different anatomical targets and sides operated firstly and secondly. We also quantified the frequency of relation between the activated tissue volume and the planned target through computer simulations. RESULTS: None of the 16 electrodes were exactly implanted at the planned coordinates. A stimulation of 3 mA reached 62.5% of the times the planned coordinates, rising to 68.75% with a 3,5 mA. No statistical significance was demonstrated in any comparison of laterality and anatomical sites. CONCLUSIONS: The simulation of small amperage fields could reach the intended target even when electrode placement is suboptimal. Furthermore, such a goal can be achieved without overlapping the volume of activated tissue with undesired structures. Software Lead-DBS proved to be a valuable complementary asset for surgical stereotactical result assessment.
- 1 June 2021
- Published by FapUNIFESP (SciELO) in Revista da Associação Médica Brasileira
- Vol. 67 (6) , 816-821
Open AccessLead-DBS: an additional tool for stereotactic surgery
OBJECTIVE: Use Lead-DBS software to analyze stereotactical surgical outcome of an operated population and demonstrate that small target deviations do not compromise the stimulation of desired structures, even with small amperages. METHODS: Image exams of patients submitted to deep brain stimulation for movement disorders treatment were processed in Lead-DBS software. Electrode stereotactic coordinates were subtracted from the planned target and those deviations, compared among different anatomical targets and sides operated firstly and secondly. We also quantified the frequency of relation between the activated tissue volume and the planned target through computer simulations. RESULTS: None of the 16 electrodes were exactly implanted at the planned coordinates. A stimulation of 3 mA reached 62.5% of the times the planned coordinates, rising to 68.75% with a 3,5 mA. No statistical significance was demonstrated in any comparison of laterality and anatomical sites. CONCLUSIONS: The simulation of small amperage fields could reach the intended target even when electrode placement is suboptimal. Furthermore, such a goal can be achieved without overlapping the volume of activated tissue with undesired structures. Software Lead-DBS proved to be a valuable complementary asset for surgical stereotactical result assessment.
- 5 April 2016
- Published by Wolters Kluwer Health in Neurology
- Vol. 86 (16_supplem)
Two Atypical Cases of Stiff-Person Syndrome (P2.263)
- 5 April 2016
- Published by Wolters Kluwer Health in Neurology
- Vol. 86 (16_supplem)
Two Atypical Cases of Stiff-Person Syndrome (P2.263)