Jamie Burke
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Jamie Burke has a total of 53 co-authors. Here are the top co-authors by number of shared publications:
Charlene Hamid
Clinical Research Facility and Imaging, University of Edinburgh
11 shared publicationsIan J. C. MacCormick
Robert O Curle Ophthalmology Suite Institute for Regeneration and Repair University of Edinburgh Edinburgh UK
9 shared publicationsStuart King
School of Mathematics, University of Edinburgh Edinburgh UK
9 shared publicationsDan Pugh
British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
7 shared publicationsNeeraj Dhaun
British Heart Foundation Centre for Cardiovascular Science, University of Edinburgh, Edinburgh, United Kingdom
7 shared publicationsAmos Storkey
Institute for Adaptive and Neural Computation, School of Informatics, University of Edinburgh, Edinburgh, United Kingdom
5 shared publications
Latest Publications
- Open Access
Direct Retinal Imaging for Shock Resuscitation in Critical Ill Adults II (D-RISC II)
Background Shock involves microcirculatory dysfunction that is not suitably captured well by measurements of large vessels, such as systemic blood pressure. The outer retinal microcirculation (the choroid) can be measured non-invasively and may reflect dysfunction in other organs. We tested the feasibility of measuring the retinal choroid in an intensive care setting and explored associations between choroidal measurements and severity of disease. Methods We performed optical coherence tomography on patients admitted to the intensive treatment unit, and repeated imaging once 12-72 hours later. We measured choroidal anatomy using automated image segmentation, compared this to routine clinical data, and described change over time. Results Of fifteen patients recruited, 80% (12) had successful baseline imaging and 40% (6) of these had follow-up imaging within intensive care. At baseline, patients with thicker choroids and larger vascularity had larger cumulative fluid balance, and lower disease severity (Acute Physiology and Chronic Health Evaluation II) score, haematocrit, and albumin. A measurable suprachoroidal space was seen in 75% (9) patients and the size of this space tended to be larger in patients with lower heart rates. There was substantial intraindividual variation in choroidal measurements over time. Comment Measuring the retinal choroid is feasible in patients with critical illness. Exploratory associations with systemic variables suggest that the choroid may provide information about the microvascular function of other major organs. Size and change of choroidal measurements may reflect perfusion pressure or vascular leak in response to inflammation.
Open AccessDirect Retinal Imaging for Shock Resuscitation in Critical Ill Adults II (D-RISC II)
Background Shock involves microcirculatory dysfunction that is not suitably captured well by measurements of large vessels, such as systemic blood pressure. The outer retinal microcirculation (the choroid) can be measured non-invasively and may reflect dysfunction in other organs. We tested the feasibility of measuring the retinal choroid in an intensive care setting and explored associations between choroidal measurements and severity of disease. Methods We performed optical coherence tomography on patients admitted to the intensive treatment unit, and repeated imaging once 12-72 hours later. We measured choroidal anatomy using automated image segmentation, compared this to routine clinical data, and described change over time. Results Of fifteen patients recruited, 80% (12) had successful baseline imaging and 40% (6) of these had follow-up imaging within intensive care. At baseline, patients with thicker choroids and larger vascularity had larger cumulative fluid balance, and lower disease severity (Acute Physiology and Chronic Health Evaluation II) score, haematocrit, and albumin. A measurable suprachoroidal space was seen in 75% (9) patients and the size of this space tended to be larger in patients with lower heart rates. There was substantial intraindividual variation in choroidal measurements over time. Comment Measuring the retinal choroid is feasible in patients with critical illness. Exploratory associations with systemic variables suggest that the choroid may provide information about the microvascular function of other major organs. Size and change of choroidal measurements may reflect perfusion pressure or vascular leak in response to inflammation.
- Open Access
- 16 January 2025
- Published by Wiley in Alzheimer's & Dementia: Diagnosis, Assessment & Disease Monitoring
- Vol. 17 (1) , e70075
Association between choroidal microvasculature in the eye and Alzheimer's disease risk in cognitively healthy mid‐life adults: A pilot study
INTRODUCTION: We explored associations between measurements of the ocular choroid microvasculature and Alzheimer's disease (AD) risk.METHODS: We measured the choroidal vasculature appearing in optical coherence tomography (OCT) scans of 69 healthy, mid‐life individuals in the PREVENT Dementia cohort. The cohort was prospectively split into low‐, medium‐, and high‐risk groups based on the presence of known risk factors (apolipoprotein E [APOE] ε4 genotype and family history of dementia [FH]). We used ordinal logistic regression to test for cross‐sectional associations between choroidal measurements and AD risk.RESULTS: Choroidal vasculature was progressively larger between ordinal risk groups, and significantly associated with risk group prediction. APOE ε4 carriers had thicker choroids and larger vascularity compared to non‐carriers. Similar trends were observed for those with a FH.DISCUSSIONS: Our results suggest a potential link between the choroidal vasculature and AD risk. However, these exploratory findings should be replicated in a larger sample.Highlights: Ocular choroidal microvasculature is of interest in relation to neurodegeneration due to its autonomic response to systemic, pathophysiological change. Choroidal changes in the prodromal stage of Alzheimer's disease (AD) are unexplored. The PREVENT Dementia cohort offers a unique, non‐invasive study of the microvasculature in mid‐life individuals at increased risk for developing AD. Significantly increased ocular choroidal vasculature was associated with increased risk (apolipoprotein E carrier and/or family history of dementia) for AD. These exploratory results suggest a potential association between the ocular choroidal vasculature and AD risk. However, findings should be replicated in a larger sample.
- 16 January 2025
- Published by Wiley in Alzheimer's & Dementia: Diagnosis, Assessment & Disease Monitoring
- Vol. 17 (1) , e70075
Open AccessAssociation between choroidal microvasculature in the eye and Alzheimer's disease risk in cognitively healthy mid‐life adults: A pilot study
INTRODUCTION: We explored associations between measurements of the ocular choroid microvasculature and Alzheimer's disease (AD) risk.METHODS: We measured the choroidal vasculature appearing in optical coherence tomography (OCT) scans of 69 healthy, mid‐life individuals in the PREVENT Dementia cohort. The cohort was prospectively split into low‐, medium‐, and high‐risk groups based on the presence of known risk factors (apolipoprotein E [APOE] ε4 genotype and family history of dementia [FH]). We used ordinal logistic regression to test for cross‐sectional associations between choroidal measurements and AD risk.RESULTS: Choroidal vasculature was progressively larger between ordinal risk groups, and significantly associated with risk group prediction. APOE ε4 carriers had thicker choroids and larger vascularity compared to non‐carriers. Similar trends were observed for those with a FH.DISCUSSIONS: Our results suggest a potential link between the choroidal vasculature and AD risk. However, these exploratory findings should be replicated in a larger sample.Highlights: Ocular choroidal microvasculature is of interest in relation to neurodegeneration due to its autonomic response to systemic, pathophysiological change. Choroidal changes in the prodromal stage of Alzheimer's disease (AD) are unexplored. The PREVENT Dementia cohort offers a unique, non‐invasive study of the microvasculature in mid‐life individuals at increased risk for developing AD. Significantly increased ocular choroidal vasculature was associated with increased risk (apolipoprotein E carrier and/or family history of dementia) for AD. These exploratory results suggest a potential association between the ocular choroidal vasculature and AD risk. However, findings should be replicated in a larger sample.
- Open Access
- 4 November 2024
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 13 (11) , 7
SLOctolyzer: Fully Automatic Analysis Toolkit for Segmentation and Feature Extracting in Scanning Laser Ophthalmoscopy Images
Purpose: The purpose of this study was to introduce SLOctolyzer: an open-source analysis toolkit for en face retinal vessels in infrared reflectance scanning laser ophthalmoscopy (SLO) images. Methods: SLOctolyzer includes two main modules: segmentation and measurement. The segmentation module uses deep learning methods to delineate retinal anatomy, and detects the fovea and optic disc, whereas the measurement module quantifies the complexity, density, tortuosity, and caliber of the segmented retinal vessels. We evaluated the segmentation module using unseen data and measured its reproducibility. Results: SLOctolyzer's segmentation module performed well against unseen internal test data (Dice for all-vessels = 0.91; arteries = 0.84; veins = 0.85; optic disc = 0.94; and fovea = 0.88). External validation against severe retinal pathology showed decreased performance (Dice for arteries = 0.72; veins = 0.75; and optic disc = 0.90). SLOctolyzer had good reproducibility (mean difference for fractal dimension = −0.001; density = −0.0003; caliber = −0.32 microns; and tortuosity density = 0.001). SLOctolyzer can process a 768 × 768 pixel macula-centered SLO image in under 20 seconds and a disc-centered SLO image in under 30 seconds using a laptop CPU. Conclusions: To our knowledge, SLOctolyzer is the first open-source tool to convert raw SLO images into reproducible and clinically meaningful retinal vascular parameters. It requires no specialist knowledge or proprietary software, and allows manual correction of segmentations and re-computing of vascular metrics. SLOctolyzer is freely available at https://github.com/jaburke166/SLOctolyzer. Translational Relevance: SLO images are captured simultaneous to optical coherence tomography (OCT), and we believe SLOctolyzer will be useful for extracting retinal vascular measurements from large OCT image sets and linking them to ocular or systemic diseases.
- 4 November 2024
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 13 (11) , 7
Open AccessSLOctolyzer: Fully Automatic Analysis Toolkit for Segmentation and Feature Extracting in Scanning Laser Ophthalmoscopy Images
Purpose: The purpose of this study was to introduce SLOctolyzer: an open-source analysis toolkit for en face retinal vessels in infrared reflectance scanning laser ophthalmoscopy (SLO) images. Methods: SLOctolyzer includes two main modules: segmentation and measurement. The segmentation module uses deep learning methods to delineate retinal anatomy, and detects the fovea and optic disc, whereas the measurement module quantifies the complexity, density, tortuosity, and caliber of the segmented retinal vessels. We evaluated the segmentation module using unseen data and measured its reproducibility. Results: SLOctolyzer's segmentation module performed well against unseen internal test data (Dice for all-vessels = 0.91; arteries = 0.84; veins = 0.85; optic disc = 0.94; and fovea = 0.88). External validation against severe retinal pathology showed decreased performance (Dice for arteries = 0.72; veins = 0.75; and optic disc = 0.90). SLOctolyzer had good reproducibility (mean difference for fractal dimension = −0.001; density = −0.0003; caliber = −0.32 microns; and tortuosity density = 0.001). SLOctolyzer can process a 768 × 768 pixel macula-centered SLO image in under 20 seconds and a disc-centered SLO image in under 30 seconds using a laptop CPU. Conclusions: To our knowledge, SLOctolyzer is the first open-source tool to convert raw SLO images into reproducible and clinically meaningful retinal vascular parameters. It requires no specialist knowledge or proprietary software, and allows manual correction of segmentations and re-computing of vascular metrics. SLOctolyzer is freely available at https://github.com/jaburke166/SLOctolyzer. Translational Relevance: SLO images are captured simultaneous to optical coherence tomography (OCT), and we believe SLOctolyzer will be useful for extracting retinal vascular measurements from large OCT image sets and linking them to ocular or systemic diseases.
- Open Access
Association between choroidal microvasculature in the eye and Alzheimer’s disease risk in cognitively healthy midlife adults: a pilot study
Objective To explore associations between measurements of the ocular microvasculature in the choroid (a highly vascularised layer posterior to the retina) and genetic Alzheimer’s disease risk. Methods We measured the choroidal vasculature appearing in optical coherence tomography scans of 69 healthy, mid-life individuals in the PREVENT cohort. The cohort was prospectively split into low, medium, and high-risk groups based on the presence of known risk factors (APOE4 genotype and family history of dementia). We used ordinal logistic regression to test for cross-sectional associations between choroidal measurements and pre-determined risk of future Alzheimer’s disease. Results We observed progressively increased choroidal vasculature between ordinal risk groups, and all choroidal measurements were significantly associated with risk group prediction. APOE4 carriers had significantly thicker choroids and larger vascular tissue compared to non-carriers. Similar trends were observed for those with a family history of dementia. In our sample, a 0.16 mm2 increase in choroidal vascular area was associated with a 2-fold increase in the likelihood of having one or more markers of Alzheimer’s disease risk, compared with none. Conclusions Our results suggest a potential link between the choroidal vasculature and risk of Alzheimer’s disease. However, these findings are exploratory and should be replicated in a larger, more diverse sample.
Open AccessAssociation between choroidal microvasculature in the eye and Alzheimer’s disease risk in cognitively healthy midlife adults: a pilot study
Objective To explore associations between measurements of the ocular microvasculature in the choroid (a highly vascularised layer posterior to the retina) and genetic Alzheimer’s disease risk. Methods We measured the choroidal vasculature appearing in optical coherence tomography scans of 69 healthy, mid-life individuals in the PREVENT cohort. The cohort was prospectively split into low, medium, and high-risk groups based on the presence of known risk factors (APOE4 genotype and family history of dementia). We used ordinal logistic regression to test for cross-sectional associations between choroidal measurements and pre-determined risk of future Alzheimer’s disease. Results We observed progressively increased choroidal vasculature between ordinal risk groups, and all choroidal measurements were significantly associated with risk group prediction. APOE4 carriers had significantly thicker choroids and larger vascular tissue compared to non-carriers. Similar trends were observed for those with a family history of dementia. In our sample, a 0.16 mm2 increase in choroidal vascular area was associated with a 2-fold increase in the likelihood of having one or more markers of Alzheimer’s disease risk, compared with none. Conclusions Our results suggest a potential link between the choroidal vasculature and risk of Alzheimer’s disease. However, these findings are exploratory and should be replicated in a larger, more diverse sample.
- Open Access
- 3 June 2024
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 65 (6) , 6
Choroidalyzer: An Open-Source, End-to-End Pipeline for Choroidal Analysis in Optical Coherence Tomography
Purpose: To develop Choroidalyzer, an open-source, end-to-end pipeline for segmenting the choroid region, vessels, and fovea, and deriving choroidal thickness, area, and vascular index. Methods: We used 5600 OCT B-scans (233 subjects, six systemic disease cohorts, three device types, two manufacturers). To generate region and vessel ground-truths, we used state-of-the-art automatic methods following manual correction of inaccurate segmentations, with foveal positions manually annotated. We trained a U-Net deep learning model to detect the region, vessels, and fovea to calculate choroid thickness, area, and vascular index in a fovea-centered region of interest. We analyzed segmentation agreement (AUC, Dice) and choroid metrics agreement (Pearson, Spearman, mean absolute error [MAE]) in internal and external test sets. We compared Choroidalyzer to two manual graders on a small subset of external test images and examined cases of high error. Results: Choroidalyzer took 0.299 seconds per image on a standard laptop and achieved excellent region (Dice: internal 0.9789, external 0.9749), very good vessel segmentation performance (Dice: internal 0.8817, external 0.8703), and excellent fovea location prediction (MAE: internal 3.9 pixels, external 3.4 pixels). For thickness, area, and vascular index, Pearson correlations were 0.9754, 0.9815, and 0.8285 (internal)/0.9831, 0.9779, 0.7948 (external), respectively (all P < 0.0001). Choroidalyzer's agreement with graders was comparable to the intergrader agreement across all metrics. Conclusions: Choroidalyzer is an open-source, end-to-end pipeline that accurately segments the choroid and reliably extracts thickness, area, and vascular index. Especially choroidal vessel segmentation is a difficult and subjective task, and fully automatic methods like Choroidalyzer could provide objectivity and standardization.
- 3 June 2024
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 65 (6) , 6
Open AccessChoroidalyzer: An Open-Source, End-to-End Pipeline for Choroidal Analysis in Optical Coherence Tomography
Purpose: To develop Choroidalyzer, an open-source, end-to-end pipeline for segmenting the choroid region, vessels, and fovea, and deriving choroidal thickness, area, and vascular index. Methods: We used 5600 OCT B-scans (233 subjects, six systemic disease cohorts, three device types, two manufacturers). To generate region and vessel ground-truths, we used state-of-the-art automatic methods following manual correction of inaccurate segmentations, with foveal positions manually annotated. We trained a U-Net deep learning model to detect the region, vessels, and fovea to calculate choroid thickness, area, and vascular index in a fovea-centered region of interest. We analyzed segmentation agreement (AUC, Dice) and choroid metrics agreement (Pearson, Spearman, mean absolute error [MAE]) in internal and external test sets. We compared Choroidalyzer to two manual graders on a small subset of external test images and examined cases of high error. Results: Choroidalyzer took 0.299 seconds per image on a standard laptop and achieved excellent region (Dice: internal 0.9789, external 0.9749), very good vessel segmentation performance (Dice: internal 0.8817, external 0.8703), and excellent fovea location prediction (MAE: internal 3.9 pixels, external 3.4 pixels). For thickness, area, and vascular index, Pearson correlations were 0.9754, 0.9815, and 0.8285 (internal)/0.9831, 0.9779, 0.7948 (external), respectively (all P < 0.0001). Choroidalyzer's agreement with graders was comparable to the intergrader agreement across all metrics. Conclusions: Choroidalyzer is an open-source, end-to-end pipeline that accurately segments the choroid and reliably extracts thickness, area, and vascular index. Especially choroidal vessel segmentation is a difficult and subjective task, and fully automatic methods like Choroidalyzer could provide objectivity and standardization.
- Open Access
Domain-specific augmentations with resolution agnostic self-attention mechanism improves choroid segmentation in optical coherence tomography images
The choroid is a key vascular layer of the eye, supplying oxygen to the retinal photoreceptors. Non-invasive enhanced depth imaging optical coherence tomography (EDI-OCT) has recently improved access and visualisation of the choroid, making it an exciting frontier for discovering novel vascular biomarkers in ophthalmology and wider systemic health. However, current methods to measure the choroid often require use of multiple, independent semi-automatic and deep learning-based algorithms which are not made open-source. Previously, Choroidalyzer -- an open-source, fully automatic deep learning method trained on 5,600 OCT B-scans from 385 eyes -- was developed to fully segment and quantify the choroid in EDI-OCT images, thus addressing these issues. Using the same dataset, we propose a Robust, Resolution-agnostic and Efficient Attention-based network for CHoroid segmentation (REACH). REACHNet leverages multi-resolution training with domain-specific data augmentation to promote generalisation, and uses a lightweight architecture with resolution-agnostic self-attention which is not only faster than Choroidalyzer's previous network (4 images/s vs. 2.75 images/s on a standard laptop CPU), but has greater performance for segmenting the choroid region, vessels and fovea (Dice coefficient for region 0.9769 vs. 0.9749, vessels 0.8612 vs. 0.8192 and fovea 0.8243 vs. 0.3783) due to its improved hyperparameter configuration and model training pipeline. REACHNet can be used with Choroidalyzer as a drop-in replacement for the original model and will be made available upon publication.
Open AccessDomain-specific augmentations with resolution agnostic self-attention mechanism improves choroid segmentation in optical coherence tomography images
The choroid is a key vascular layer of the eye, supplying oxygen to the retinal photoreceptors. Non-invasive enhanced depth imaging optical coherence tomography (EDI-OCT) has recently improved access and visualisation of the choroid, making it an exciting frontier for discovering novel vascular biomarkers in ophthalmology and wider systemic health. However, current methods to measure the choroid often require use of multiple, independent semi-automatic and deep learning-based algorithms which are not made open-source. Previously, Choroidalyzer -- an open-source, fully automatic deep learning method trained on 5,600 OCT B-scans from 385 eyes -- was developed to fully segment and quantify the choroid in EDI-OCT images, thus addressing these issues. Using the same dataset, we propose a Robust, Resolution-agnostic and Efficient Attention-based network for CHoroid segmentation (REACH). REACHNet leverages multi-resolution training with domain-specific data augmentation to promote generalisation, and uses a lightweight architecture with resolution-agnostic self-attention which is not only faster than Choroidalyzer's previous network (4 images/s vs. 2.75 images/s on a standard laptop CPU), but has greater performance for segmenting the choroid region, vessels and fovea (Dice coefficient for region 0.9769 vs. 0.9749, vessels 0.8612 vs. 0.8192 and fovea 0.8243 vs. 0.3783) due to its improved hyperparameter configuration and model training pipeline. REACHNet can be used with Choroidalyzer as a drop-in replacement for the original model and will be made available upon publication.
- Open Access
Choroidalyzer: An open-source, end-to-end pipeline for choroidal analysis in optical coherence tomography
Purpose: To develop Choroidalyzer, an open-source, end-to-end pipeline for segmenting the choroid region, vessels, and fovea, and deriving choroidal thickness, area, and vascular index. Methods: We used 5,600 OCT B-scans (233 subjects, 6 systemic disease cohorts, 3 device types, 2 manufacturers). To generate region and vessel ground-truths, we used state-of-the-art automatic methods following manual correction of inaccurate segmentations, with foveal positions manually annotated. We trained a U-Net deep-learning model to detect the region, vessels, and fovea to calculate choroid thickness, area, and vascular index in a fovea-centred region of interest. We analysed segmentation agreement (AUC, Dice) and choroid metrics agreement (Pearson, Spearman, mean absolute error (MAE)) in internal and external test sets. We compared Choroidalyzer to two manual graders on a small subset of external test images and examined cases of high error. Results: Choroidalyzer took 0.299 seconds per image on a standard laptop and achieved excellent region (Dice: internal 0.9789, external 0.9749), very good vessel segmentation performance (Dice: internal 0.8817, external 0.8703) and excellent fovea location prediction (MAE: internal 3.9 pixels, external 3.4 pixels). For thickness, area, and vascular index, Pearson correlations were 0.9754, 0.9815, and 0.8285 (internal) / 0.9831, 0.9779, 0.7948 (external), respectively (all p<0.0001). Choroidalyzer's agreement with graders was comparable to the inter-grader agreement across all metrics. Conclusions: Choroidalyzer is an open-source, end-to-end pipeline that accurately segments the choroid and reliably extracts thickness, area, and vascular index. Especially choroidal vessel segmentation is a difficult and subjective task, and fully-automatic methods like Choroidalyzer could provide objectivity and standardisation.
Open AccessChoroidalyzer: An open-source, end-to-end pipeline for choroidal analysis in optical coherence tomography
Purpose: To develop Choroidalyzer, an open-source, end-to-end pipeline for segmenting the choroid region, vessels, and fovea, and deriving choroidal thickness, area, and vascular index. Methods: We used 5,600 OCT B-scans (233 subjects, 6 systemic disease cohorts, 3 device types, 2 manufacturers). To generate region and vessel ground-truths, we used state-of-the-art automatic methods following manual correction of inaccurate segmentations, with foveal positions manually annotated. We trained a U-Net deep-learning model to detect the region, vessels, and fovea to calculate choroid thickness, area, and vascular index in a fovea-centred region of interest. We analysed segmentation agreement (AUC, Dice) and choroid metrics agreement (Pearson, Spearman, mean absolute error (MAE)) in internal and external test sets. We compared Choroidalyzer to two manual graders on a small subset of external test images and examined cases of high error. Results: Choroidalyzer took 0.299 seconds per image on a standard laptop and achieved excellent region (Dice: internal 0.9789, external 0.9749), very good vessel segmentation performance (Dice: internal 0.8817, external 0.8703) and excellent fovea location prediction (MAE: internal 3.9 pixels, external 3.4 pixels). For thickness, area, and vascular index, Pearson correlations were 0.9754, 0.9815, and 0.8285 (internal) / 0.9831, 0.9779, 0.7948 (external), respectively (all p<0.0001). Choroidalyzer's agreement with graders was comparable to the inter-grader agreement across all metrics. Conclusions: Choroidalyzer is an open-source, end-to-end pipeline that accurately segments the choroid and reliably extracts thickness, area, and vascular index. Especially choroidal vessel segmentation is a difficult and subjective task, and fully-automatic methods like Choroidalyzer could provide objectivity and standardisation.
- Open Access
- 1 November 2023
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 12 (11) , 27
An Open-Source Deep Learning Algorithm for Efficient and Fully Automatic Analysis of the Choroid in Optical Coherence Tomography
Purpose: To develop an open-source, fully automatic deep learning algorithm, DeepGPET, for choroid region segmentation in optical coherence tomography (OCT) data. Methods: We used a dataset of 715 OCT B-scans (82 subjects, 115 eyes) from three clinical studies related to systemic disease. Ground-truth segmentations were generated using a clinically validated, semiautomatic choroid segmentation method, Gaussian Process Edge Tracing (GPET). We finetuned a U-Net with the MobileNetV3 backbone pretrained on ImageNet. Standard segmentation agreement metrics, as well as derived measures of choroidal thickness and area, were used to evaluate DeepGPET, alongside qualitative evaluation from a clinical ophthalmologist. Results: DeepGPET achieved excellent agreement with GPET on data from three clinical studies (AUC = 0.9994, Dice = 0.9664; Pearson correlation = 0.8908 for choroidal thickness and 0.9082 for choroidal area), while reducing the mean processing time per image on a standard laptop CPU from 34.49 ± 15.09 seconds using GPET to 1.25 ± 0.10 seconds using DeepGPET. Both methods performed similarly according to a clinical ophthalmologist who qualitatively judged a subset of segmentations by GPET and DeepGPET, based on smoothness and accuracy of segmentations. Conclusions: DeepGPET, a fully automatic, open-source algorithm for choroidal segmentation, will enable researchers to efficiently extract choroidal measurements, even for large datasets. As no manual interventions are required, DeepGPET is less subjective than semiautomatic methods and could be deployed in clinical practice without requiring a trained operator. Translational Relevance: DeepGPET addresses the lack of open-source, fully automatic, and clinically relevant choroid segmentation algorithms, and its subsequent public release will facilitate future choroidal research in both ophthalmology and wider systemic health.
- 1 November 2023
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 12 (11) , 27
Open AccessAn Open-Source Deep Learning Algorithm for Efficient and Fully Automatic Analysis of the Choroid in Optical Coherence Tomography
Purpose: To develop an open-source, fully automatic deep learning algorithm, DeepGPET, for choroid region segmentation in optical coherence tomography (OCT) data. Methods: We used a dataset of 715 OCT B-scans (82 subjects, 115 eyes) from three clinical studies related to systemic disease. Ground-truth segmentations were generated using a clinically validated, semiautomatic choroid segmentation method, Gaussian Process Edge Tracing (GPET). We finetuned a U-Net with the MobileNetV3 backbone pretrained on ImageNet. Standard segmentation agreement metrics, as well as derived measures of choroidal thickness and area, were used to evaluate DeepGPET, alongside qualitative evaluation from a clinical ophthalmologist. Results: DeepGPET achieved excellent agreement with GPET on data from three clinical studies (AUC = 0.9994, Dice = 0.9664; Pearson correlation = 0.8908 for choroidal thickness and 0.9082 for choroidal area), while reducing the mean processing time per image on a standard laptop CPU from 34.49 ± 15.09 seconds using GPET to 1.25 ± 0.10 seconds using DeepGPET. Both methods performed similarly according to a clinical ophthalmologist who qualitatively judged a subset of segmentations by GPET and DeepGPET, based on smoothness and accuracy of segmentations. Conclusions: DeepGPET, a fully automatic, open-source algorithm for choroidal segmentation, will enable researchers to efficiently extract choroidal measurements, even for large datasets. As no manual interventions are required, DeepGPET is less subjective than semiautomatic methods and could be deployed in clinical practice without requiring a trained operator. Translational Relevance: DeepGPET addresses the lack of open-source, fully automatic, and clinically relevant choroid segmentation algorithms, and its subsequent public release will facilitate future choroidal research in both ophthalmology and wider systemic health.
- Open Access
- 1 November 2023
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 12 (11) , 19
Evaluation of an Automated Choroid Segmentation Algorithm in a Longitudinal Kidney Donor and Recipient Cohort
Purpose: To evaluate the performance of an automated choroid segmentation algorithm in optical coherence tomography (OCT) data using a longitudinal kidney donor and recipient cohort. Methods: We assessed 22 donors and 23 patients requiring renal transplantation over up to 1 year posttransplant. We measured choroidal thickness (CT) and area and compared our automated CT measurements to manual ones at the same locations. We estimated associations between choroidal measurements and markers of renal function (estimated glomerular filtration rate [eGFR], serum creatinine, and urea) using correlation and linear mixed-effects (LME) modeling. Results: There was good agreement between manual and automated CT. Automated measures were more precise because of smaller measurement error over time. External adjudication of major discrepancies was in favor of automated measures. Significant differences were observed in the choroid pre- and posttransplant in both cohorts, and LME modeling revealed significant linear associations observed between choroidal measures and renal function in recipients. Significant associations were mostly stronger with automated CT (eGFR, P < 0.001; creatinine, P = 0.004; urea, P = 0.04) compared to manual CT (eGFR, P = 0.002; creatinine, P = 0.01; urea, P = 0.03). Conclusions: Our automated approach has greater precision than human-performed manual measurements, which may explain stronger associations with renal function compared to manual measurements. To improve detection of meaningful associations with clinical endpoints in longitudinal studies of OCT, reducing measurement error should be a priority, and automated measurements help achieve this. Translational Relevance: We introduce a novel choroid segmentation algorithm that can replace manual grading for studying the choroid in renal disease and other clinical conditions.
- 1 November 2023
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Translational Vision Science & Technology
- Vol. 12 (11) , 19
Open AccessEvaluation of an Automated Choroid Segmentation Algorithm in a Longitudinal Kidney Donor and Recipient Cohort
Purpose: To evaluate the performance of an automated choroid segmentation algorithm in optical coherence tomography (OCT) data using a longitudinal kidney donor and recipient cohort. Methods: We assessed 22 donors and 23 patients requiring renal transplantation over up to 1 year posttransplant. We measured choroidal thickness (CT) and area and compared our automated CT measurements to manual ones at the same locations. We estimated associations between choroidal measurements and markers of renal function (estimated glomerular filtration rate [eGFR], serum creatinine, and urea) using correlation and linear mixed-effects (LME) modeling. Results: There was good agreement between manual and automated CT. Automated measures were more precise because of smaller measurement error over time. External adjudication of major discrepancies was in favor of automated measures. Significant differences were observed in the choroid pre- and posttransplant in both cohorts, and LME modeling revealed significant linear associations observed between choroidal measures and renal function in recipients. Significant associations were mostly stronger with automated CT (eGFR, P < 0.001; creatinine, P = 0.004; urea, P = 0.04) compared to manual CT (eGFR, P = 0.002; creatinine, P = 0.01; urea, P = 0.03). Conclusions: Our automated approach has greater precision than human-performed manual measurements, which may explain stronger associations with renal function compared to manual measurements. To improve detection of meaningful associations with clinical endpoints in longitudinal studies of OCT, reducing measurement error should be a priority, and automated measurements help achieve this. Translational Relevance: We introduce a novel choroid segmentation algorithm that can replace manual grading for studying the choroid in renal disease and other clinical conditions.
- Open Access
An open-source deep learning algorithm for efficient and fully-automatic analysis of the choroid in optical coherence tomography
Purpose: To develop an open-source, fully-automatic deep learning algorithm, DeepGPET, for choroid region segmentation in optical coherence tomography (OCT) data. Methods: We used a dataset of 715 OCT B-scans (82 subjects, 115 eyes) from 3 clinical studies related to systemic disease. Ground truth segmentations were generated using a clinically validated, semi-automatic choroid segmentation method, Gaussian Process Edge Tracing (GPET). We finetuned a UNet with MobileNetV3 backbone pre-trained on ImageNet. Standard segmentation agreement metrics, as well as derived measures of choroidal thickness and area, were used to evaluate DeepGPET, alongside qualitative evaluation from a clinical ophthalmologist. Results: DeepGPET achieves excellent agreement with GPET on data from 3 clinical studies (AUC=0.9994, Dice=0.9664; Pearson correlation of 0.8908 for choroidal thickness and 0.9082 for choroidal area), while reducing the mean processing time per image on a standard laptop CPU from 34.49s ($\pm$15.09) using GPET to 1.25s ($\pm$0.10) using DeepGPET. Both methods performed similarly according to a clinical ophthalmologist, who qualitatively judged a subset of segmentations by GPET and DeepGPET, based on smoothness and accuracy of segmentations. Conclusions: DeepGPET, a fully-automatic, open-source algorithm for choroidal segmentation, will enable researchers to efficiently extract choroidal measurements, even for large datasets. As no manual interventions are required, DeepGPET is less subjective than semi-automatic methods and could be deployed in clinical practice without necessitating a trained operator.
Open AccessAn open-source deep learning algorithm for efficient and fully-automatic analysis of the choroid in optical coherence tomography
Purpose: To develop an open-source, fully-automatic deep learning algorithm, DeepGPET, for choroid region segmentation in optical coherence tomography (OCT) data. Methods: We used a dataset of 715 OCT B-scans (82 subjects, 115 eyes) from 3 clinical studies related to systemic disease. Ground truth segmentations were generated using a clinically validated, semi-automatic choroid segmentation method, Gaussian Process Edge Tracing (GPET). We finetuned a UNet with MobileNetV3 backbone pre-trained on ImageNet. Standard segmentation agreement metrics, as well as derived measures of choroidal thickness and area, were used to evaluate DeepGPET, alongside qualitative evaluation from a clinical ophthalmologist. Results: DeepGPET achieves excellent agreement with GPET on data from 3 clinical studies (AUC=0.9994, Dice=0.9664; Pearson correlation of 0.8908 for choroidal thickness and 0.9082 for choroidal area), while reducing the mean processing time per image on a standard laptop CPU from 34.49s ($\pm$15.09) using GPET to 1.25s ($\pm$0.10) using DeepGPET. Both methods performed similarly according to a clinical ophthalmologist, who qualitatively judged a subset of segmentations by GPET and DeepGPET, based on smoothness and accuracy of segmentations. Conclusions: DeepGPET, a fully-automatic, open-source algorithm for choroidal segmentation, will enable researchers to efficiently extract choroidal measurements, even for large datasets. As no manual interventions are required, DeepGPET is less subjective than semi-automatic methods and could be deployed in clinical practice without necessitating a trained operator.