Zhen Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Zhen Chen has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Baoliang Zhang
Institute of Metrology, China Electric Power Research Institutes, Beijing 100192, China
1 shared publication - Guodong Sun
YanTai DongFang Wisdom Electric Co., Ltd., Yantai 264003, China
1 shared publication - Jia Qi
School of measurement and communication engineering, Harbin University of Science and Technology, Harbin 150080, China
1 shared publication - Jiahai Zhang
Yantai Dongfang Wisdom Electric Co., Ltd., Yantai 264000, China
1 shared publication - Pingxin Wang
State Grid Shandong Electric Power Company Metering Service Marketing Center, Jinan 250001, China
1 shared publication - Suqin Xiong
China Electric Power Research Institute Co., Ltd., Beijing 100192, China
1 shared publication
Latest Publications
- Open Access
Failure Prediction and Replacement Strategies for Smart Electricity Meters Based on Field Failure Observation
It is helpful to have a replacement strategy by predicting the number of failures of in-service electricity meters. This paper presents a failure number prediction method for smart electricity meters based on on-site fault data. The prediction model was constructed by combining Weibull distribution with odds ratios, then the distribution parameters, failure prediction number, and confidence intervals of prediction number were calculated. A strategy of meter replacement and reserve were developed according to the prediction results. To avoid the uncertainty of prediction results due to the small amount of field data information, a Bayesian failure number prediction method was developed. The research results have value for making operation plans and reserve strategies for electricity meters.
Open AccessFailure Prediction and Replacement Strategies for Smart Electricity Meters Based on Field Failure Observation
It is helpful to have a replacement strategy by predicting the number of failures of in-service electricity meters. This paper presents a failure number prediction method for smart electricity meters based on on-site fault data. The prediction model was constructed by combining Weibull distribution with odds ratios, then the distribution parameters, failure prediction number, and confidence intervals of prediction number were calculated. A strategy of meter replacement and reserve were developed according to the prediction results. To avoid the uncertainty of prediction results due to the small amount of field data information, a Bayesian failure number prediction method was developed. The research results have value for making operation plans and reserve strategies for electricity meters.
- Open Access
- 3 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (23) , 11457
Effects of Environmental and Electrical Factors on Metering Error and Consistency of Smart Electricity Meters
The smart electricity meter (SEM) is an important part of smart power grid, and the accuracy of SEMs is the basis for power grid operation control and trade settlement between power supply and electricity consumption, but the evolution behaviors of metering error of SEMs under field operation conditions have not yet been identified. The SEMs were installed and operated on site, metering error data were collected under various temperature and current conditions. The influences of current, power coefficient, and temperature on metering error and consistency were analyzed separately with the help of quadratic polynomials, and then an integrated model elaborating the joint effects of multi-stress was developed based on a binary quadratic polynomial. We find that a lower temperature and a larger current result in a higher metering error of SEMs; however, the effects of current on metering error are determined by power coefficients. The results have reference value for remote metrological verification, error monitoring, and the optimization of the operation and maintenance scheme of SEMs.
- 3 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (23) , 11457
Open AccessEffects of Environmental and Electrical Factors on Metering Error and Consistency of Smart Electricity Meters
The smart electricity meter (SEM) is an important part of smart power grid, and the accuracy of SEMs is the basis for power grid operation control and trade settlement between power supply and electricity consumption, but the evolution behaviors of metering error of SEMs under field operation conditions have not yet been identified. The SEMs were installed and operated on site, metering error data were collected under various temperature and current conditions. The influences of current, power coefficient, and temperature on metering error and consistency were analyzed separately with the help of quadratic polynomials, and then an integrated model elaborating the joint effects of multi-stress was developed based on a binary quadratic polynomial. We find that a lower temperature and a larger current result in a higher metering error of SEMs; however, the effects of current on metering error are determined by power coefficients. The results have reference value for remote metrological verification, error monitoring, and the optimization of the operation and maintenance scheme of SEMs.