Jason Forman
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Jason Forman has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Daniel F. Shedd
Center for Applied Biomechanics, University of Virginia, Charlottesville, USA
2 shared publications - J. McMahon
Center for Applied Biomechanics, University of Virginia, Charlottesville, USA
2 shared publications - J. Sebastian Giudice
Center for Applied Biomechanics, University of Virginia, Charlottesville, USA
2 shared publications - Jared A. Rifkin
Center for Applied Biomechanics, University of Virginia, Charlottesville, USA
2 shared publications - Matthew B. Panzer
Center for Applied Biomechanics, University of Virginia, Charlottesville, VA, USA
2 shared publications - Parker Berthelson
Center for Applied Biomechanics, University of Virginia, Charlottesville, USA
2 shared publications
Latest Publications
- Open Access
- 29 July 2025
- Published by Springer Nature in Annals of Biomedical Engineering
Correction to: Disc Injury and Spine Loads in Low-to-Moderate-Severity Frontal Impacts
- 29 July 2025
- Published by Springer Nature in Annals of Biomedical Engineering
Open AccessCorrection to: Disc Injury and Spine Loads in Low-to-Moderate-Severity Frontal Impacts
- Open Access
- 19 July 2025
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 53 (10) , 2689-2700
Disc Injury and Spine Loads in Low-to-Moderate-Severity Frontal Impacts
Purpose: Determine the cervical and lumbar spine forces and moments generated in belted occupants in frontal impacts up to 40-km/h change in velocity ( $${\Delta }V$$ ) and assess their potential to cause spinal disc injury. Methods: Loads experienced by anthropomorphic test devices, human volunteers, and human cadavers were measured in 282 impact tests. Functions were developed to describe the expected loads as functions of $${\Delta }V$$ for small females, mid-size males, and large males. Loads were contextualized by comparison to injury assessment reference values, manual lifting standards, the compressive loads that have caused spinal disc injuries in vitro, and the compressive spinal loads that occur in other situations. Results: The functions confirm that the spinal loads are well below any established injury assessment reference value. Compressive loads are within the range of loads voluntarily tolerated during daily activities and well below the loads that have caused disc injuries in biomechanical studies. Conclusion: This study confirms the lack of a biomechanical foundation to assert specific causation when a belted occupant presents with isolated disc herniations, bulges, or extrusions through the annulus following a frontal impact under 40-km/h $${\Delta }V$$ .- 19 July 2025
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 53 (10) , 2689-2700
Open AccessDisc Injury and Spine Loads in Low-to-Moderate-Severity Frontal Impacts
Purpose: Determine the cervical and lumbar spine forces and moments generated in belted occupants in frontal impacts up to 40-km/h change in velocity ( $${\Delta }V$$ ) and assess their potential to cause spinal disc injury. Methods: Loads experienced by anthropomorphic test devices, human volunteers, and human cadavers were measured in 282 impact tests. Functions were developed to describe the expected loads as functions of $${\Delta }V$$ for small females, mid-size males, and large males. Loads were contextualized by comparison to injury assessment reference values, manual lifting standards, the compressive loads that have caused spinal disc injuries in vitro, and the compressive spinal loads that occur in other situations. Results: The functions confirm that the spinal loads are well below any established injury assessment reference value. Compressive loads are within the range of loads voluntarily tolerated during daily activities and well below the loads that have caused disc injuries in biomechanical studies. Conclusion: This study confirms the lack of a biomechanical foundation to assert specific causation when a belted occupant presents with isolated disc herniations, bulges, or extrusions through the annulus following a frontal impact under 40-km/h $${\Delta }V$$ . - 11 October 2023
- Published by Elsevier in Accident Analysis & Prevention
- Vol. 193, 107334
Comparison of thoracolumbar spine kinematics and injuries in reclined frontal impact sled tests between mid-size adult female and male PMHS
- 11 October 2023
- Published by Elsevier in Accident Analysis & Prevention
- Vol. 193, 107334
Comparison of thoracolumbar spine kinematics and injuries in reclined frontal impact sled tests between mid-size adult female and male PMHS
- 10 October 2022
- Published by Taylor & Francis in Traffic Injury Prevention
- Vol. 23 (sup1) , S199-S201
Methodology to measure seat belt fit in relation to skeletal geometry using an upright open MRI
Poor seat belt fit can result in submarining behavior and injuries to the lower extremity and abdomen. While previous studies have explored seat belt fit relative to skeletal landmarks using palpat...
- 10 October 2022
- Published by Taylor & Francis in Traffic Injury Prevention
- Vol. 23 (sup1) , S199-S201
Methodology to measure seat belt fit in relation to skeletal geometry using an upright open MRI
Poor seat belt fit can result in submarining behavior and injuries to the lower extremity and abdomen. While previous studies have explored seat belt fit relative to skeletal landmarks using palpat...
- 5 March 2022
- Published by Springer Nature in Human Factors and Mechanical Engineering for Defense and Safety
- Vol. 6 (1) , 1-12
The Risk of Skin Injury Caused by High-Rate Blunt Impacts to the Human Thorax
- 5 March 2022
- Published by Springer Nature in Human Factors and Mechanical Engineering for Defense and Safety
- Vol. 6 (1) , 1-12
The Risk of Skin Injury Caused by High-Rate Blunt Impacts to the Human Thorax
- 23 February 2022
- Published by Springer Nature in Human Factors and Mechanical Engineering for Defense and Safety
- Vol. 6 (1) , 1-12
Evaluation of an In Situ Ovine Model as a Surrogate for Human Skin Injury Caused by High-Rate Blunt Impact
- 23 February 2022
- Published by Springer Nature in Human Factors and Mechanical Engineering for Defense and Safety
- Vol. 6 (1) , 1-12
Evaluation of an In Situ Ovine Model as a Surrogate for Human Skin Injury Caused by High-Rate Blunt Impact
- Open Access
- 29 November 2021
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 25 (10) , 1125-1155
Evaluation of a diverse population of morphed human body models for prediction of vehicle occupant crash kinematics
Morphing can be used to alter human body models (HBMs) to represent a diverse population of occupants in car crashes. The mid-sized male SAFER HBM v9 was parametrically morphed to match 22 Post Mortem Human Subjects, loaded in different configurations. Kinetics and kinematics were compared for the morphed and baseline HBMs. In frontal impacts, the morphed HBMs correlated closer with the kinematics of obese subjects, but lower to small females. In lateral impacts HBM responses were too stiff. This study outlines a necessary evaluation of all HBMs that should be morphed to represent the diverse population in vehicle safety evaluations.
- 29 November 2021
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering
- Vol. 25 (10) , 1125-1155
Open AccessEvaluation of a diverse population of morphed human body models for prediction of vehicle occupant crash kinematics
Morphing can be used to alter human body models (HBMs) to represent a diverse population of occupants in car crashes. The mid-sized male SAFER HBM v9 was parametrically morphed to match 22 Post Mortem Human Subjects, loaded in different configurations. Kinetics and kinematics were compared for the morphed and baseline HBMs. In frontal impacts, the morphed HBMs correlated closer with the kinematics of obese subjects, but lower to small females. In lateral impacts HBM responses were too stiff. This study outlines a necessary evaluation of all HBMs that should be morphed to represent the diverse population in vehicle safety evaluations.
- 19 October 2021
- Published by Taylor & Francis in Traffic Injury Prevention
- Vol. 22 (sup1) , S152-S155
Complementing femur model validation with a variability-focused approach
This short communication presents an approach as an objective means to validate that population variability is potentially incorporated into human body models in an accurate way, complementing exis...
- 19 October 2021
- Published by Taylor & Francis in Traffic Injury Prevention
- Vol. 22 (sup1) , S152-S155
Complementing femur model validation with a variability-focused approach
This short communication presents an approach as an objective means to validate that population variability is potentially incorporated into human body models in an accurate way, complementing exis...
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 53, 255-257
Effect of Contact Friction between Seatbelt and Human Body Model on Simulation of Rib Fracture in Frontal Impact
Seatbelt contact friction coefficient may have some influence on chest injury prediction because it can affect the position of the seatbelt during the impact. The objective was to study the influence of the seatbelt contact friction coefficient on predicted rib fracture outcome in frontal impact. Four simulations of frontal impact sled tests in the same environment were conducted wherein the contact friction coefficient between the seatbelt and the chest model was varied. A noticeable effect was observed wherein increasing friction coefficient which tended to cause a slight decrease in the number of predicted fractures. Despite this, the magnitude of sensitivity was small, suggesting that in the absence of other information arbitrary values of friction coefficient within a reasonable intermediate range may be justified for this specific test condition.
- 1 March 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 53, 255-257
Effect of Contact Friction between Seatbelt and Human Body Model on Simulation of Rib Fracture in Frontal Impact
Seatbelt contact friction coefficient may have some influence on chest injury prediction because it can affect the position of the seatbelt during the impact. The objective was to study the influence of the seatbelt contact friction coefficient on predicted rib fracture outcome in frontal impact. Four simulations of frontal impact sled tests in the same environment were conducted wherein the contact friction coefficient between the seatbelt and the chest model was varied. A noticeable effect was observed wherein increasing friction coefficient which tended to cause a slight decrease in the number of predicted fractures. Despite this, the magnitude of sensitivity was small, suggesting that in the absence of other information arbitrary values of friction coefficient within a reasonable intermediate range may be justified for this specific test condition.