Do Mai Nguyen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Do Mai Nguyen has a total of 28 co-authors. Here are the top co-authors by number of shared publications:
- Tran Thanh Tam Toan
Phu Xuan University
13 shared publications - Anh Quang Dao
Faculty of Environmental and Natural Sciences, Duy Tan University, Da Nang, 550000, Vietnam
6 shared publications - Vo Chau Ngoc Anh
University of Medicine and Pharmacy, Hue University, 530000, Vietnam
6 shared publications - Dinh Tuan
Nam Can Tho University
4 shared publications - Nguyen Minh Quang
Industrial University of Ho Chi Minh City
4 shared publications Nguyen Minh Quang
Faculty of Chemical Engineering, Industrial University of Ho Chi Minh City, Ho Chi Minh City 700000, Vietnam
2 shared publications
Latest Publications
- Open Access
- 13 November 2026
- Published by The Electrochemical Society in ECS Sensors Plus
- Vol. 5 (4) , 042504
Sustainable Cu 2 O-Carbon Dot Heterointerfaces Derived from Rice Straw for the Anti-Fouling Electrochemical Detection of Vancomycin
Accurate therapeutic monitoring of vancomycin (VCM) is clinically critical due to its narrow therapeutic window. While high-performance liquid chromatography offers high accuracy, it remains constrained by high operational costs and complex sample preparation. Although electrochemical platforms provide a rapid alternative, conventional electrodes frequently experience sluggish charge-transfer kinetics and surface passivation during antibiotic analysis. This study addresses these limitations by developing an electrochemical sensor utilizing a hybrid cuprous oxide–carbon dot (Cu 2 O-CD) composite. The carbon dot (CD) component, synthesized from rice straw via a sustainable hydrothermal route, resolves the conductivity and agglomeration issues typical of pure Cu 2 O nanoparticles. This hybrid architecture creates a selective heterointerface that facilitates charge-transfer kinetics while improving signal stability during consecutive measurements. The sensor demonstrates a detection limit of 8.3 nM with a linear range of 0.01–2.39 μ M. Analytical reliability was verified in human urine samples, with recovery rates ranging from 97.3% to 102.0%, confirming the platform’s potential for practical analytical applications.
- 13 November 2026
- Published by The Electrochemical Society in ECS Sensors Plus
- Vol. 5 (4) , 042504
Open AccessSustainable Cu 2 O-Carbon Dot Heterointerfaces Derived from Rice Straw for the Anti-Fouling Electrochemical Detection of Vancomycin
Accurate therapeutic monitoring of vancomycin (VCM) is clinically critical due to its narrow therapeutic window. While high-performance liquid chromatography offers high accuracy, it remains constrained by high operational costs and complex sample preparation. Although electrochemical platforms provide a rapid alternative, conventional electrodes frequently experience sluggish charge-transfer kinetics and surface passivation during antibiotic analysis. This study addresses these limitations by developing an electrochemical sensor utilizing a hybrid cuprous oxide–carbon dot (Cu 2 O-CD) composite. The carbon dot (CD) component, synthesized from rice straw via a sustainable hydrothermal route, resolves the conductivity and agglomeration issues typical of pure Cu 2 O nanoparticles. This hybrid architecture creates a selective heterointerface that facilitates charge-transfer kinetics while improving signal stability during consecutive measurements. The sensor demonstrates a detection limit of 8.3 nM with a linear range of 0.01–2.39 μ M. Analytical reliability was verified in human urine samples, with recovery rates ranging from 97.3% to 102.0%, confirming the platform’s potential for practical analytical applications.
- Open Access
- 23 June 2026
- Published by The Electrochemical Society in ECS Sensors Plus
- Vol. 5 (3) , 033602
Box-Behnken Optimized One-Step CO-Synthesis of Poly(pyrocatechol violet)-Reduced Graphene Oxide: A Green Strategy for Metronidazole Detection
A novel electrochemical sensor was fabricated for the sensitive detection of Metronidazole by modifying a glassy carbon electrode with a nanocomposite of poly(pyrocatechol violet) and electrochemically reduced graphene oxide. The fabrication process employed a simple, one-step cyclic voltammetry method, which allowed for the simultaneous electropolymerization of the monomer and the reduction of graphene oxide without the use of toxic chemical reducing agents. The synthesis conditions were systematically optimized using a Box-Behnken Design to maximize the electrochemical response. The developed poly(pyrocatechol violet)/electrochemically reduced graphene oxide modified glassy carbon electrode exhibited excellent electrocatalytic activity toward the reduction of MTZ, as evidenced by a significant increase in peak current compared to bare and single-component-modified electrodes. Under optimal conditions, the sensor demonstrated a wide linear working range from 0.1 to 20 µM, with a low limit of detection of 0.013 µM. The method's precision was confirmed by relative standard deviations below 5.1% for repeatability and 3.7% for reproducibility. Furthermore, the sensor showed high selectivity in the presence of common biological interferents and inorganic ions. The practical applicability of the proposed method was successfully validated by determining MTZ in human urine samples, yielding results that were statistically comparable to those obtained by High-Performance Liquid Chroma
- 23 June 2026
- Published by The Electrochemical Society in ECS Sensors Plus
- Vol. 5 (3) , 033602
Open AccessBox-Behnken Optimized One-Step CO-Synthesis of Poly(pyrocatechol violet)-Reduced Graphene Oxide: A Green Strategy for Metronidazole Detection
A novel electrochemical sensor was fabricated for the sensitive detection of Metronidazole by modifying a glassy carbon electrode with a nanocomposite of poly(pyrocatechol violet) and electrochemically reduced graphene oxide. The fabrication process employed a simple, one-step cyclic voltammetry method, which allowed for the simultaneous electropolymerization of the monomer and the reduction of graphene oxide without the use of toxic chemical reducing agents. The synthesis conditions were systematically optimized using a Box-Behnken Design to maximize the electrochemical response. The developed poly(pyrocatechol violet)/electrochemically reduced graphene oxide modified glassy carbon electrode exhibited excellent electrocatalytic activity toward the reduction of MTZ, as evidenced by a significant increase in peak current compared to bare and single-component-modified electrodes. Under optimal conditions, the sensor demonstrated a wide linear working range from 0.1 to 20 µM, with a low limit of detection of 0.013 µM. The method's precision was confirmed by relative standard deviations below 5.1% for repeatability and 3.7% for reproducibility. Furthermore, the sensor showed high selectivity in the presence of common biological interferents and inorganic ions. The practical applicability of the proposed method was successfully validated by determining MTZ in human urine samples, yielding results that were statistically comparable to those obtained by High-Performance Liquid Chroma
- Open Access
- 22 May 2026
- Published by Royal Society of Chemistry (RSC) in RSC Sustainability
- Vol. 4 (10) , 3651-3664
Facile hydrothermal assembly of WS 2 –RGO heterostructures guided by chemometrics: a green electrochemical strategy for ceftriaxone surveillance in livestock
A green WS 2 –RGO electrochemical sensor, optimized via chemometrics, enables highly sensitive detection of ceftriaxone. Achieving an ultralow LOD of 0.009 µM, it provides a robust tool for antibiotic surveillance in livestock.
- 22 May 2026
- Published by Royal Society of Chemistry (RSC) in RSC Sustainability
- Vol. 4 (10) , 3651-3664
Open AccessFacile hydrothermal assembly of WS 2 –RGO heterostructures guided by chemometrics: a green electrochemical strategy for ceftriaxone surveillance in livestock
A green WS 2 –RGO electrochemical sensor, optimized via chemometrics, enables highly sensitive detection of ceftriaxone. Achieving an ultralow LOD of 0.009 µM, it provides a robust tool for antibiotic surveillance in livestock.
- Open Access
- 16 February 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 16 (11) , 9547-9562
Electrochemical resolution of purine metabolite overlap using a synthesis-assisted Fe 2 O 3 -RGO heterointerface
A one-step Fe 2 O 3 -RGO coating was shown to suppress xanthine and hypoxanthine interference, enabling sensitive electrochemical determination of uric acid.
- 16 February 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 16 (11) , 9547-9562
Open AccessElectrochemical resolution of purine metabolite overlap using a synthesis-assisted Fe 2 O 3 -RGO heterointerface
A one-step Fe 2 O 3 -RGO coating was shown to suppress xanthine and hypoxanthine interference, enabling sensitive electrochemical determination of uric acid.
- Open Access
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
Sustainable electrocatalysis: overcoming signal convolution of dopamine and paracetamol at a pristine graphene interface
A pristine graphene interface was fabricated through a green electrochemical method. Signal overlap and surface fouling were successfully overcome to achieve the highly sensitive simultaneous detection of dopamine and paracetamol.
- 1 January 2026
- Published by Royal Society of Chemistry (RSC) in RSC Advances
Open AccessSustainable electrocatalysis: overcoming signal convolution of dopamine and paracetamol at a pristine graphene interface
A pristine graphene interface was fabricated through a green electrochemical method. Signal overlap and surface fouling were successfully overcome to achieve the highly sensitive simultaneous detection of dopamine and paracetamol.
- Open Access
- 30 May 2025
- Published by Royal Society of Chemistry (RSC) in RSC Applied Interfaces
- Vol. 2 (5) , 1209-1219
Green electrochemical sensing of ampicillin using reduced graphene oxide-modified electrodes
A “green” rGO-modified GCE enables ultrasensitive ampicillin detection with a 6.75 nM limit, good selectivity, and reliability, enhancing electron transfer for precise analysis.
- 30 May 2025
- Published by Royal Society of Chemistry (RSC) in RSC Applied Interfaces
- Vol. 2 (5) , 1209-1219
Open AccessGreen electrochemical sensing of ampicillin using reduced graphene oxide-modified electrodes
A “green” rGO-modified GCE enables ultrasensitive ampicillin detection with a 6.75 nM limit, good selectivity, and reliability, enhancing electron transfer for precise analysis.
- Open Access
- 7 March 2025
- Published by Royal Society of Chemistry (RSC) in Nanoscale Advances
- Vol. 7 (9) , 2554-2567
Fe2O3–rice straw carbon dot composite for simultaneous electrochemical detection of dopamine and salbutamol
A novel Fe2O3–rice straw carbon dot composite resolves overlapping peaks, enabling sensitive electrochemical detection of dopamine and salbutamol.
- 7 March 2025
- Published by Royal Society of Chemistry (RSC) in Nanoscale Advances
- Vol. 7 (9) , 2554-2567
Open AccessFe2O3–rice straw carbon dot composite for simultaneous electrochemical detection of dopamine and salbutamol
A novel Fe2O3–rice straw carbon dot composite resolves overlapping peaks, enabling sensitive electrochemical detection of dopamine and salbutamol.
- 1 February 2025
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 172 (2) , 027509
Simultaneous Electrochemical Examination of Ractopamine and Clenbuterol Employing Carbon Dots Derived from Rice Straw
In this study, rice straw-based carbon dots (RSCD) synthesized via a hydrothermal method were effectively utilized for modifying glassy carbon electrodes in differential pulse voltammetry to determine ractopamine (RTP) and clenbuterol (CLB) simultaneously. The structural, optical, and elemental properties of RSCD were characterized using X-ray diffraction, Fourier transform infrared spectroscopy, Raman spectroscopy, tunneling electron microscopy, UV–vis, photoluminescence spectra, and energy-dispersive X-ray elemental mapping. The RSCD-modified glassy carbon electrode (RSCD/GCE) demonstrated enhanced electrochemical outcome in cyclic voltammetry tests and differential pulse voltammetry tests, compared to bare GCE. The RSCD/GCE showed distinct oxidation peaks for RTP (+0.88 V) and CLB (+1.88 V), indicating high selectivity. The method stated a broad linear concentration range of 0.1–92 μM with limits of detection of 0.09 μM for RTP and 0.03 μM for CLB. Interference studies revealed negligible impact from common ions and organic substances. The RSCD/GCE demonstrated good repeatability, reproducibility, and stability over a week. This study underscores the potential of RSCD/GCE as a working electrode for reliable and sensitive DPV determination of β-agonists residue in food safety applications.
- 1 February 2025
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 172 (2) , 027509
Simultaneous Electrochemical Examination of Ractopamine and Clenbuterol Employing Carbon Dots Derived from Rice Straw
In this study, rice straw-based carbon dots (RSCD) synthesized via a hydrothermal method were effectively utilized for modifying glassy carbon electrodes in differential pulse voltammetry to determine ractopamine (RTP) and clenbuterol (CLB) simultaneously. The structural, optical, and elemental properties of RSCD were characterized using X-ray diffraction, Fourier transform infrared spectroscopy, Raman spectroscopy, tunneling electron microscopy, UV–vis, photoluminescence spectra, and energy-dispersive X-ray elemental mapping. The RSCD-modified glassy carbon electrode (RSCD/GCE) demonstrated enhanced electrochemical outcome in cyclic voltammetry tests and differential pulse voltammetry tests, compared to bare GCE. The RSCD/GCE showed distinct oxidation peaks for RTP (+0.88 V) and CLB (+1.88 V), indicating high selectivity. The method stated a broad linear concentration range of 0.1–92 μM with limits of detection of 0.09 μM for RTP and 0.03 μM for CLB. Interference studies revealed negligible impact from common ions and organic substances. The RSCD/GCE demonstrated good repeatability, reproducibility, and stability over a week. This study underscores the potential of RSCD/GCE as a working electrode for reliable and sensitive DPV determination of β-agonists residue in food safety applications.
- 1 May 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (5) , 057507
Review—Nanotechnology in Aquaculture: Applications and Challenges
Aquaculture, driven by increasing demands for animal proteins and fats, faces multifaceted challenges stemming from environmental factors such as climate change and pollution, alongside issues like disease susceptibility and limited therapeutic tools. However, the emergence of nanotechnology (NNT) offers a promising solution across various aquaculture domains. Nano-enhanced feed has been shown to improve fish growth rates, while nanomaterials are reducing the treatment economy by effectively eliminating contaminants. Genetic manipulation methods combined with nanobiotechnology have revolutionized fish ancestry studies, with advancements such as nanosensors and DNA-based vaccines significantly impacting fish life and immune systems. Moreover, nanotechnology plays a crucial role in enhancing fish processing, enabling sterile packaging and precise flavoring. Utilizing fishery waste through bio-nano-engineering and green nanoparticles offers new post-harvesting practices. Despite ongoing exploration, NNT presents versatile applications, prospects, and challenges in aquaculture, as detailed in this review. This paper provides an in-depth analysis of current trends, challenges, and prospects of NNT applications in aquaculture.
- 1 May 2024
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 171 (5) , 057507
Review—Nanotechnology in Aquaculture: Applications and Challenges
Aquaculture, driven by increasing demands for animal proteins and fats, faces multifaceted challenges stemming from environmental factors such as climate change and pollution, alongside issues like disease susceptibility and limited therapeutic tools. However, the emergence of nanotechnology (NNT) offers a promising solution across various aquaculture domains. Nano-enhanced feed has been shown to improve fish growth rates, while nanomaterials are reducing the treatment economy by effectively eliminating contaminants. Genetic manipulation methods combined with nanobiotechnology have revolutionized fish ancestry studies, with advancements such as nanosensors and DNA-based vaccines significantly impacting fish life and immune systems. Moreover, nanotechnology plays a crucial role in enhancing fish processing, enabling sterile packaging and precise flavoring. Utilizing fishery waste through bio-nano-engineering and green nanoparticles offers new post-harvesting practices. Despite ongoing exploration, NNT presents versatile applications, prospects, and challenges in aquaculture, as detailed in this review. This paper provides an in-depth analysis of current trends, challenges, and prospects of NNT applications in aquaculture.
- 1 May 2023
- Published by The Electrochemical Society in ECS Journal of Solid State Science and Technology
- Vol. 12 (5) , 057007
The Dual Detection of Uric Acid and Paracetamol in Biological Fluids with the Modified “Green” Sensor through the Electropolymerization
The PM material was effectively synthesized in this study via electropolymerization. The electrochemical characteristics of glassy carbon electrodes (GCE)@RGO were examined after the PM was polymerized onto its surface to create PM-RGO/GCE with the support of the CV technique. Furthermore, employing this modified electrode, URA and PCM were examined by applying CV and DPV electrochemical techniques. In comparison to employing the RGO/GCE, the modified PM-RGO/GCE electrode showed good responsiveness toward URA and PCM applying the DPV technique, with LOD values of 0.040 μM for URA, and 0.025 μM for PCM. The linear concentrations ranged from 0.06 to 1 μM. These factors like Na+, SO4 2−, Ca2+, Cl−, NH4 +, NO3 − ions, ascorbic acid, dopamine, hypoxanthine and xanthine, did not interfere during the modified electrode’s operation. Within this paper, it is worth emphasizing that these analytical processes for the URA and PCM in actual sample solutions are more dependable than the HPLC method.
- 1 May 2023
- Published by The Electrochemical Society in ECS Journal of Solid State Science and Technology
- Vol. 12 (5) , 057007
The Dual Detection of Uric Acid and Paracetamol in Biological Fluids with the Modified “Green” Sensor through the Electropolymerization
The PM material was effectively synthesized in this study via electropolymerization. The electrochemical characteristics of glassy carbon electrodes (GCE)@RGO were examined after the PM was polymerized onto its surface to create PM-RGO/GCE with the support of the CV technique. Furthermore, employing this modified electrode, URA and PCM were examined by applying CV and DPV electrochemical techniques. In comparison to employing the RGO/GCE, the modified PM-RGO/GCE electrode showed good responsiveness toward URA and PCM applying the DPV technique, with LOD values of 0.040 μM for URA, and 0.025 μM for PCM. The linear concentrations ranged from 0.06 to 1 μM. These factors like Na+, SO4 2−, Ca2+, Cl−, NH4 +, NO3 − ions, ascorbic acid, dopamine, hypoxanthine and xanthine, did not interfere during the modified electrode’s operation. Within this paper, it is worth emphasizing that these analytical processes for the URA and PCM in actual sample solutions are more dependable than the HPLC method.