Qiao Zheng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Qiao Zheng has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Hong-Ning Xie
Department of Ultrasonic Medicine, Fetal Medical Centre, the First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
3 shared publications - Ting Lei
Department of Ultrasonic Medicine The First Affiliated Hospital of Sun Yat‐sen University Guangzhou Guangdong China
2 shared publications - Chun-Yang Zhang
Sun Yat Sen Univ, Inst Diagnost & Intervent Ultrasound, Dept Med Ultrason, Ultras Artificial Intelligence X Lab,Affiliated H, Guangzhou, Peoples R China
1 shared publication - Han Bai
Department of Ultrasonic Medicine The First Affiliated Hospital of Sun Yat‐sen University Guangzhou China
1 shared publication - Huanling Guo
Sun Yat Sen Univ, Inst Diagnost & Intervent Ultrasound, Dept Med Ultrason, Ultras Artificial Intelligence X Lab,Affiliated H, Guangzhou, Peoples R China
1 shared publication - Hui Shen
Department of Ultrasonic Medicine, Fetal Medical Centre, the First Affiliated Hospital of Sun Yat-sen University, Guangzhou, China
1 shared publication
Latest Publications
- 11 August 2026
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 45 (12) , 2953-2963
Artificial Intelligence–Based Multimodal Ultrasound Model for Prediction of Spontaneous Preterm Birth
Objectives: The primary aim of this study was to develop a multimodal artificial intelligence model for predicting spontaneous preterm birth using cervical 2‐dimensional ultrasound and elastography images, as well as ultrasound parameters. Methods: This prospective cohort study recruited pregnant women undergoing transvaginal ultrasound screening at 20–24 weeks of gestation. Participants were divided into spontaneous preterm birth group and full‐term group. Three deep learning models were trained on images to compute scores via the best‐performing model. Five supervised machine learning classifiers were developed and validated to predict spontaneous preterm birth based on ultrasound parameters and deep learning scores, and feature importance analysis was employed to visualize the importance of each feature in the model. Results: A total of 721 pregnant women (44 with spontaneous preterm birth) were included. In deep learning models based on ultrasound images, DenseNet121 (AUC: 0.92/0.93) model exhibited excellent performance, and corresponding scores were obtained. Elasticity contrast index, hardness ratio, external os stiffness, Ratio, 2‐dimension‐score, and elastography‐score were included to construct the 5 machine learning models. Among the multimodal models, the neural network model showed the best predictive performance in the validation set (AUC = 0.85; 95% CI, 0.73–0.96). Feature importance analysis revealed that both elastography‐score and 2‐dimension‐score made significant contributions in a majority of the models. Conclusions: The multimodal artificial intelligence models using ultrasound parameters and cervical 2‐dimensional ultrasound and elastography images demonstrated promising predictive capabilities in internal validation for spontaneous preterm birth in the second trimester. This offers assistance for intervention in patients at high risk of spontaneous preterm birth.
- 11 August 2026
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 45 (12) , 2953-2963
Artificial Intelligence–Based Multimodal Ultrasound Model for Prediction of Spontaneous Preterm Birth
Objectives: The primary aim of this study was to develop a multimodal artificial intelligence model for predicting spontaneous preterm birth using cervical 2‐dimensional ultrasound and elastography images, as well as ultrasound parameters. Methods: This prospective cohort study recruited pregnant women undergoing transvaginal ultrasound screening at 20–24 weeks of gestation. Participants were divided into spontaneous preterm birth group and full‐term group. Three deep learning models were trained on images to compute scores via the best‐performing model. Five supervised machine learning classifiers were developed and validated to predict spontaneous preterm birth based on ultrasound parameters and deep learning scores, and feature importance analysis was employed to visualize the importance of each feature in the model. Results: A total of 721 pregnant women (44 with spontaneous preterm birth) were included. In deep learning models based on ultrasound images, DenseNet121 (AUC: 0.92/0.93) model exhibited excellent performance, and corresponding scores were obtained. Elasticity contrast index, hardness ratio, external os stiffness, Ratio, 2‐dimension‐score, and elastography‐score were included to construct the 5 machine learning models. Among the multimodal models, the neural network model showed the best predictive performance in the validation set (AUC = 0.85; 95% CI, 0.73–0.96). Feature importance analysis revealed that both elastography‐score and 2‐dimension‐score made significant contributions in a majority of the models. Conclusions: The multimodal artificial intelligence models using ultrasound parameters and cervical 2‐dimensional ultrasound and elastography images demonstrated promising predictive capabilities in internal validation for spontaneous preterm birth in the second trimester. This offers assistance for intervention in patients at high risk of spontaneous preterm birth.
- 17 September 2024
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 64 (4) , 453-462
Enhancing trainee performance in obstetric ultrasound through an artificial intelligence system: randomized controlled trial
Objective: Performing obstetric ultrasound scans is challenging for inexperienced operators; therefore, the prenatal screening artificial intelligence system (PSAIS) software was developed to provide real‐time feedback and guidance for trainees during their scanning procedures. The aim of this study was to investigate the potential benefits of utilizing such an artificial intelligence system to enhance the efficiency of obstetric ultrasound training in acquiring and interpreting standard basic views.Methods: A prospective, single‐center randomized controlled study was conducted at The First Affiliated Hospital of Sun Yat‐sen University. From September 2022 to April 2023, residents with no prior obstetric ultrasound experience were recruited and assigned randomly to either a PSAIS‐assisted training group or a conventional training group. Each trainee underwent a four‐cycle practical scan training program, performing 20 scans in each cycle on pregnant volunteers at 18–32 gestational weeks, focusing on acquiring and interpreting standard basic views. At the end of each cycle, a test scan evaluated trainees' ability to obtain standard ultrasound views without PSAIS assistance, and image quality was rated by both the trainees themselves and an expert (in a blinded manner). The primary outcome was the number of training cycles required for each trainee to meet a certain standard of proficiency (i.e. end‐of‐cycle test scored by the expert at ≥ 80%). Secondary outcomes included the expert ratings of the image quality in each trainee's end‐of‐cycle test and the discordance between ratings by trainees and the expert.Results: In total, 32 residents and 1809 pregnant women (2720 scans) were recruited for the study. The PSAIS‐assisted trainee group required significantly fewer training cycles compared with the non‐PSAIS‐assisted group to meet quality requirements (P = 0.037). Based on the expert ratings of image quality, the PSAIS‐assisted training group exhibited superior ability in acquiring standard imaging views compared with the conventional training group in the third (P = 0.012) and fourth (P < 0.001) cycles. In both groups, the discordance between trainees' ratings of the quality of their own images and the expert's ratings decreased with increasing training time. A statistically significant difference in overall trainee–expert rating discordance between the two groups emerged at the end of the first training cycle and remained at every cycle thereafter (P < 0.013).Conclusion: By assisting inexperienced trainees in obtaining and interpreting standard basic obstetric scanning views, the use of artificial intelligence‐assisted systems has the potential to improve training effectiveness. © 2024 International Society of Ultrasound in Obstetrics and Gynecology.
- 17 September 2024
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 64 (4) , 453-462
Enhancing trainee performance in obstetric ultrasound through an artificial intelligence system: randomized controlled trial
Objective: Performing obstetric ultrasound scans is challenging for inexperienced operators; therefore, the prenatal screening artificial intelligence system (PSAIS) software was developed to provide real‐time feedback and guidance for trainees during their scanning procedures. The aim of this study was to investigate the potential benefits of utilizing such an artificial intelligence system to enhance the efficiency of obstetric ultrasound training in acquiring and interpreting standard basic views.Methods: A prospective, single‐center randomized controlled study was conducted at The First Affiliated Hospital of Sun Yat‐sen University. From September 2022 to April 2023, residents with no prior obstetric ultrasound experience were recruited and assigned randomly to either a PSAIS‐assisted training group or a conventional training group. Each trainee underwent a four‐cycle practical scan training program, performing 20 scans in each cycle on pregnant volunteers at 18–32 gestational weeks, focusing on acquiring and interpreting standard basic views. At the end of each cycle, a test scan evaluated trainees' ability to obtain standard ultrasound views without PSAIS assistance, and image quality was rated by both the trainees themselves and an expert (in a blinded manner). The primary outcome was the number of training cycles required for each trainee to meet a certain standard of proficiency (i.e. end‐of‐cycle test scored by the expert at ≥ 80%). Secondary outcomes included the expert ratings of the image quality in each trainee's end‐of‐cycle test and the discordance between ratings by trainees and the expert.Results: In total, 32 residents and 1809 pregnant women (2720 scans) were recruited for the study. The PSAIS‐assisted trainee group required significantly fewer training cycles compared with the non‐PSAIS‐assisted group to meet quality requirements (P = 0.037). Based on the expert ratings of image quality, the PSAIS‐assisted training group exhibited superior ability in acquiring standard imaging views compared with the conventional training group in the third (P = 0.012) and fourth (P < 0.001) cycles. In both groups, the discordance between trainees' ratings of the quality of their own images and the expert's ratings decreased with increasing training time. A statistically significant difference in overall trainee–expert rating discordance between the two groups emerged at the end of the first training cycle and remained at every cycle thereafter (P < 0.013).Conclusion: By assisting inexperienced trainees in obtaining and interpreting standard basic obstetric scanning views, the use of artificial intelligence‐assisted systems has the potential to improve training effectiveness. © 2024 International Society of Ultrasound in Obstetrics and Gynecology.
- Open Access
- 13 October 2023
- Published by Springer Nature in npj Digital Medicine
- Vol. 6 (1) , 1-10
Deep learning system improved detection efficacy of fetal intracranial malformations in a randomized controlled trial
Congenital malformations of the central nervous system are among the most common major congenital malformations. Deep learning systems have come to the fore in prenatal diagnosis of congenital malformation, but the impact of deep learning-assisted detection of congenital intracranial malformations from fetal neurosonographic images has not been evaluated. Here we report a three-way crossover, randomized control trial (Trial Registration: ChiCTR2100048233) that assesses the efficacy of a deep learning system, the Prenatal Ultrasound Diagnosis Artificial Intelligence Conduct System (PAICS), in assisting fetal intracranial malformation detection. A total of 709 fetal neurosonographic images/videos are read interactively by 36 sonologists of different expertise levels in three reading modes: unassisted mode (without PAICS assistance), concurrent mode (using PAICS at the beginning of the assessment) and second mode (using PAICS after a fully unaided interpretation). Aided by PAICS, the average accuracy of the unassisted mode (73%) is increased by the concurrent mode (80%; P < 0.001) and the second mode (82%; P < 0.001). Correspondingly, the AUC is increased from 0.85 to 0.89 and to 0.90, respectively (P < 0.001 for all). The median read time per data is slightly increased in concurrent mode but substantially prolonged in the second mode, from 6 s to 7 s and to 11 s (P < 0.001 for all). In conclusion, PAICS in both concurrent and second modes has the potential to improve sonologists’ performance in detecting fetal intracranial malformations from neurosonographic data. PAICS is more efficient when used concurrently for all readers.
- 13 October 2023
- Published by Springer Nature in npj Digital Medicine
- Vol. 6 (1) , 1-10
Open AccessDeep learning system improved detection efficacy of fetal intracranial malformations in a randomized controlled trial
Congenital malformations of the central nervous system are among the most common major congenital malformations. Deep learning systems have come to the fore in prenatal diagnosis of congenital malformation, but the impact of deep learning-assisted detection of congenital intracranial malformations from fetal neurosonographic images has not been evaluated. Here we report a three-way crossover, randomized control trial (Trial Registration: ChiCTR2100048233) that assesses the efficacy of a deep learning system, the Prenatal Ultrasound Diagnosis Artificial Intelligence Conduct System (PAICS), in assisting fetal intracranial malformation detection. A total of 709 fetal neurosonographic images/videos are read interactively by 36 sonologists of different expertise levels in three reading modes: unassisted mode (without PAICS assistance), concurrent mode (using PAICS at the beginning of the assessment) and second mode (using PAICS after a fully unaided interpretation). Aided by PAICS, the average accuracy of the unassisted mode (73%) is increased by the concurrent mode (80%; P < 0.001) and the second mode (82%; P < 0.001). Correspondingly, the AUC is increased from 0.85 to 0.89 and to 0.90, respectively (P < 0.001 for all). The median read time per data is slightly increased in concurrent mode but substantially prolonged in the second mode, from 6 s to 7 s and to 11 s (P < 0.001 for all). In conclusion, PAICS in both concurrent and second modes has the potential to improve sonologists’ performance in detecting fetal intracranial malformations from neurosonographic data. PAICS is more efficient when used concurrently for all readers.
- Open Access
- 2 December 2021
- Published by Wroclaw Medical University in Advances in Clinical and Experimental Medicine
- Vol. 31 (3) , 307-315
Can monodisperse microbubble-based three-dimensional contrast-enhanced ultrasound reduce quantitative heterogeneity? An in vitro study
Background. Heterogeneity within the tumor may cause large heterogeneity in quantitative perfusion parameters. Three-dimensional contrast-enhanced ultrasound (3D-CEUS) can show the spatial relationship of vascular structure after post-acquisition reconstruction and monodisperse bubbles can resonate the ul-trasound pulse, resulting in the increase in sensitivity of CEUS imaging. Objectives. To evaluate whether the combination of 3D-CEUS and monodisperse microbubbles could reduce the heterogeneity of quantitative CEUS. Materials and methods. Three in vitro perfusion models with perfusion volume ratio of 1:2:4 were set up. Both quantitative 2D-CEUS and 3D-CEUS were used to acquire peak intensity (PI) with 2 kinds of ultrasound agents. One was a new kind of monodisperse bubbles produced in this study, named Octafluoropropane-loaded cerasomal microbubbles (OC-MBs), the other was SonoVue (R). The coefficient of variation (CV) was calculated to evaluate the cross-sectional variability. Pearson's correlation analysis was used to assess the cor-relation between weighted PIs (average of PIs of 3 different planes) and perfusion ratios. Results. The average CVs of quantitative 3D-CEUS was slightly lower than that of 2D-CEUS (0.41 +/- 0.17 compared to 0.55 +/- 0.26, p = 0.3592). As for quantitative 3D-CEUS, the PI of the OC-MBs has shown better stability than that of SonoVue (R), but without a significant difference (average CVs: 0.32 +/- 0.19 compared to 0.50 +/- 0.10, p = 0.0711). In the 2D-CEUS condition, the average CVs of OC-MBs group and SonoVue (R) group were 0.68 +/- 0.15 and 0.41 +/- 0.17 (p = 0.2747). As for 3D-CEUS condition, using OC-MBs group and SonoVue (R), the r-values of the weighted PI and perfusion ratio were 0.8685 and 0.5643, respectively, while that of 2D-CEUS condition were 0.7760 and 0.3513, respectively. Conclusions. Our in vitro experiments showed that OC-MBs have the potential in acquiring more stable quantitative CEUS value, as compared to the SonoVue (R) in 3D-CEUS condition. The combination of 3D-CEUS and OC-MBs can reflect perfusion volume more precisely and may be a potential way to reduce quantitative heterogeneity.
- 2 December 2021
- Published by Wroclaw Medical University in Advances in Clinical and Experimental Medicine
- Vol. 31 (3) , 307-315
Open AccessCan monodisperse microbubble-based three-dimensional contrast-enhanced ultrasound reduce quantitative heterogeneity? An in vitro study
Background. Heterogeneity within the tumor may cause large heterogeneity in quantitative perfusion parameters. Three-dimensional contrast-enhanced ultrasound (3D-CEUS) can show the spatial relationship of vascular structure after post-acquisition reconstruction and monodisperse bubbles can resonate the ul-trasound pulse, resulting in the increase in sensitivity of CEUS imaging. Objectives. To evaluate whether the combination of 3D-CEUS and monodisperse microbubbles could reduce the heterogeneity of quantitative CEUS. Materials and methods. Three in vitro perfusion models with perfusion volume ratio of 1:2:4 were set up. Both quantitative 2D-CEUS and 3D-CEUS were used to acquire peak intensity (PI) with 2 kinds of ultrasound agents. One was a new kind of monodisperse bubbles produced in this study, named Octafluoropropane-loaded cerasomal microbubbles (OC-MBs), the other was SonoVue (R). The coefficient of variation (CV) was calculated to evaluate the cross-sectional variability. Pearson's correlation analysis was used to assess the cor-relation between weighted PIs (average of PIs of 3 different planes) and perfusion ratios. Results. The average CVs of quantitative 3D-CEUS was slightly lower than that of 2D-CEUS (0.41 +/- 0.17 compared to 0.55 +/- 0.26, p = 0.3592). As for quantitative 3D-CEUS, the PI of the OC-MBs has shown better stability than that of SonoVue (R), but without a significant difference (average CVs: 0.32 +/- 0.19 compared to 0.50 +/- 0.10, p = 0.0711). In the 2D-CEUS condition, the average CVs of OC-MBs group and SonoVue (R) group were 0.68 +/- 0.15 and 0.41 +/- 0.17 (p = 0.2747). As for 3D-CEUS condition, using OC-MBs group and SonoVue (R), the r-values of the weighted PI and perfusion ratio were 0.8685 and 0.5643, respectively, while that of 2D-CEUS condition were 0.7760 and 0.3513, respectively. Conclusions. Our in vitro experiments showed that OC-MBs have the potential in acquiring more stable quantitative CEUS value, as compared to the SonoVue (R) in 3D-CEUS condition. The combination of 3D-CEUS and OC-MBs can reflect perfusion volume more precisely and may be a potential way to reduce quantitative heterogeneity.