ZZZhenbin Zhang

Zhenbin Zhang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Zhenbin Zhang has a total of 33 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Tandem MICROFASP Method-Enabled High-Sensitivity In Vivo Cross-Linking Mass Spectrometry Analysis of Low-Cell-Number Samples without Enrichment

    by Yu He, Yang Li, Rong Liu, Keqi Tang, Zhengyan Hu, Zhenbin Zhang

    Cross-linking mass spectrometry (XL-MS) has emerged as an indispensable tool for dissecting protein conformations and protein–protein interactions (PPIs) within native biological systems. However, conventional in vivo XL-MS workflows suffer from significant sample loss during sample preparation, necessitating large input quantities of the starting material and fundamentally limiting their widespread applicability to mass-limited samples. Herein, we report the development of a tandem MICROFASP platform that uniquely integrates in vivo chemical cross-linking with seamless in situ sample preparation to drastically minimize sample loss throughout the entire workflow. Using disuccinimidyl suberate (DSS) as a model cross-linker, we systematically optimized all critical experimental parameters, including cross-linking reaction duration, lysis buffer formulation, and mass spectrometry data acquisition conditions. Without any pre-enrichment, we identified 517 intercross-linked peptides from just 10,000 K562 cells, a 3.5-fold increase relative to the state-of-the-art result with enrichment reported to date. Notably, 318 cross-linked peptides were identified from only 2500 living K562 cells. Structural mapping and PPI network analysis confirmed the validity of the identified cross-links, with over 97% of the cross-linked sites falling within the distance constraint of the DSS. This tandem MICROFASP method resolves the long-standing sensitivity limitation of in vivo XL-MS in low-cell-number samples, paving the way for systematic analysis of protein conformations and dynamic PPIs in clinical biopsies and the tumor microenvironment.

  • Biocompatible and Antifouling Linear Poly(N-(2-hydroxypropyl)methacrylamide)-Coated Capillaries via Aqueous RAFT Polymerization Method for Clinical Proteomics Analysis of Non-Small Cell Lung Cancer Tissue by CZE-ESI-MS/MS

    by Mengqing Yang, Jianhai Yang, Rong Liu, Liping Chen, Danyang Chen, Yu He, Yang Li, Huaying Wang, Keqi Tang, Zhengyan Hu, et al.

    Capillary coating plays a crucial role in the separation efficiency and reproducibility of capillary zone electrophoresis (CZE). In this study, a linear poly(N-(2-hydroxypropyl)methacrylamide) (LP(HPMA))-coated capillary was prepared by using the surface-confined aqueous reversible addition-fragmentation chain transfer polymerization method. The LP(HPMA)-coated capillary exhibits better biocompatibility and stability compared with the linear poly(acrylamide) (LPA)-coated capillary. Through systematic evaluation, the optimal conditions for fabricating LP(HPMA)-coated capillaries were determined as follows: 1 M HPMA, 2.7 Ă— 10-3 M 4,4'-azobis(4-cyanovaleric acid), and a reaction time of 4 h. LP(HPMA)-coated capillaries prepared under these conditions exhibited the lowest electro-osmotic flow values of 3.7 Ă— 10-6 and demonstrated exceptional performance when applied to the analysis of a HeLa cell digest. Following a 20-day treatment with 2 M NH4OAc (pH 7), the number of peptides identified using the LP(HPMA)-coated capillary decreased by 18.1% compared to the untreated LP(HPMA)-coated capillary; in contrast, the peptide numbers for the LPA-coated capillary decreased by 26.7% relative to its untreated counterpart. These results indicate that the LP(HPMA)-coated capillary exhibits superior pH stability compared to the LPA-coated capillary within the physiological pH range. The LP(HPMA)-coated capillary was employed in the clinical proteomics analysis of non-small cell lung cancer tissues and their corresponding paracancerous tissues via CZE-ESI-MS/MS. The differentially expressed proteins in each sample pair demonstrated minimal overlap, highlighting the heterogeneity of tumor tissues among different patients. Principal component analysis of the data could segregate the samples into a tumor tissue cluster and a paracancerous tissue cluster. Moreover, within each cluster, samples from different patients further separated into subclusters. This discovery validates that CZE-MS can not only distinguish between lung cancer tumor tissue and paracancerous tissue but also detect the heterogeneity among diverse patients, even with as little as 100 ng of sample. The obtained results were subsequently compared with those from nanoRPLC-MS using 1 ÎĽg of sample. Notably, the enrichment results within the three gene ontology categories for both methods showed a high level of consistency, corroborating the effectiveness of the CZE-MS method using an LP(HPMA)-coated capillary in identifying differentially expressed proteins from mass-limited clinical samples.


  • A Fast, High-Sensitivity 96-Well Plate-Based MICROFASP Method for Processing Low Microgram Proteomics Sample within 1.5 h

    by Guojin Ying, Yu He, Mengqing Yang, Gang Lu, Yang Li, Wei Cui, Zhengyan Hu, Zhenbin Zhang

    A rapid, sensitive, and high-throughput sample preparation method is of paramount significance for proteomics analysis. Here, we report a fast, high-sensitivity MICROFASP method that is capable of completing sample preparation within 1.5 h, enhancing the throughput by over 13 times compared to the previous reports. Protein digestion time was significantly cut from 17 h to 20 min in a limited volume. Simultaneous reduction and alkylation occurred within 30 min. The label-free quantitation intensities of proteins from the fast and conventional MICROFASP methods were highly correlated (r = 0.91), validating the reliability of the fast-MICROFASP method. When starting with 1 ÎĽg of K562 cell lysate, the fast-MICROFASP method identified over 6 times more protein groups and 19 times more peptides than did the iST method. A 96-well plate-based version was developed to process 8 brain tissue samples from APP/PS1 transgenic mice in parallel. Averagely, with only 1 ÎĽg of protein lysate, 2826 protein groups (n = 8, RSD = 0.7%) and 12,972 peptides (n = 8, RSD = 1.5%) were identified from each sample. Amyloid-beta protein was successfully identified as a highly expressed protein, which shows its potential for detecting diagnostic markers and proteome profiling with low-microgram samples. We anticipate the high-sensitivity 96-well plate-based fast-MICROFASP method will have wide application in high-throughput and rapid preparation of large cohorts of low-microgram samples (e.g., clinical biopsy) for comprehensive proteome profiling. Data are available via ProteomeXchange with the identifier PXD053720.


  • Capillary zone electrophoresis-tandem mass spectrometry for in-depth proteomics analysis via data-independent acquisition

    by Rong Liu, Gang Lu, Xiaozhong Hu, Junhui Li, Zhenbin Zhang, Keqi Tang

    A capillary zone electrophoresis (CZE) system was coupled to an Orbitrap mass spectrometer operating in a data-independent acquisition (DIA) mode for in-depth proteomics analysis. The performance of this CZE-DIA-MS system was systemically evaluated and optimized under different operating conditions. The performance of the fully optimized CZE-DIA-MS system was subsequently compared to the one by using the same CZE-MS system operating in a data-dependent acquisition (DDA) mode. The experimental results show that the numbers of identified peptides and proteins acquired in the DIA mode are much higher than the ones acquired in the DDA mode, especially with the small sample loading amount. Specifically, the numbers of identified peptides and proteins acquired in the DIA mode are 1.8-fold and 2-fold higher than the ones acquired in the DDA mode by using 12.5 ng Hela digests. The proteins identified in the DIA mode also cover almost all the proteins identified in the DDA mode. In addition, a potential cancer biomarker protein, carbohydrate antigen 125, undetected in the DDA mode, can be easily identified in the DIA mode even with 12.5 ng Hela digests. The performance of the CZE-DIA-MS system for in-depth proteomics analysis with a limited sample amount has been fully demonstrated for the first time through this study. Graphical Abstract


  • Integrated MICROFASP Method with CZE-Based Fractionation Technique and NanoRPLC-ESI-MS/MS for a Comprehensive Proteomics Analysis of a Submicrogram Sample

    by Gang Lu, Guojin Ying, Yu He, Yang Li, Zhenbin Zhang

    We report a loss-less two-dimensional (2D) separation platform that integrated capillary zone electrophoresis (CZE) fractionation and nanoRPLC-ESI-MS/MS for a comprehensive proteomics analysis of a submicrogram sample. Protein digest was injected into the linear polyacrylamide-coated capillary, followed by CZE separation. The schemes for collecting the fractions were carefully optimized to maximize the protein coverage. The peptide fractions were directly eluted into the autosampler insert vials, followed by the nanoRPLC-ESI-MS/MS analysis without lyophilization and redissolution, thus dramatically minimizing sample loss and potential contamination. The integrated platform generated 30,845 unique peptides and 5231 protein groups from 500 ng of a HeLa protein digest within 11.5 h (90 min CZE fractionation plus 10 h LC-MS analysis). Finally, the developed platform was used to analyze the protein digest prepared by the MICROFASP method with 1 mu g of cell lysate as the starting material. Three thousand seven hundred ninety-six (N = 2, RSD = 4.95%) protein groups and 20,577 (N = 2, RSD = 7.89%) peptides were identified from only 200 ng of the resulted tryptic digest within 5.5 h. The results indicated that the combination of the MICROFASP method and the developed CZE/nanoRPLC-MS/MS 2D separation platform enabled comprehensive proteome profiling of a submicrogram biological sample. Data are available via ProteomeXchange with the identifier PXD052735.


  • An Optimized Miniaturized Filter-Aided Sample Preparation Method for Sensitive Cross-Linking Mass Spectrometry Analysis of Microscale Samples

    by Yu He, Yang Li, Lili Zhao, Guojin Ying, Gang Lu, Lihua Zhang, Zhenbin Zhang

    Cross-linking mass spectrometry (XL-MS) is a powerful tool for elucidating protein structures and protein-protein interactions (PPIs) at the global scale. However, sensitive XL-MS analysis of mass-limited samples remains challenging, due to serious sample loss during sample preparation of the low-abundance cross-linked peptides. Herein, an optimized miniaturized filter-aided sample preparation (O-MICROFASP) method was presented for sensitive XL-MS analysis of microscale samples. By systematically investigating and optimizing crucial experimental factors, this approach dramatically improves the XL identification of low and submicrogram samples. Compared with the conventional FASP method, more than 7.4 times cross-linked peptides were identified from single-shot analysis of 1 μg DSS cross-linked HeLa cell lysates (440 vs 59). The number of cross-linked peptides identified from 0.5 μg HeLa cell lysates was increased by 58% when further reducing the surface area of the filter to 0.058 mm2 in the microreactor. To deepen the identification coverage of XL-proteome, five different types of cross-linkers were used and each μg of cross-linked HeLa cell lysates was processed by O-MICROFASP integrated with tip-based strong cation exchange (SCX) fractionation. Up to 2741 unique cross-linked peptides were identified from the 5 μg HeLa cell lysates, representing 2579 unique K-K linkages on 1092 proteins. About 96% of intraprotein cross-links were within the maximal distance restraints of 26 Å, and 75% of the identified PPIs reported by the STRING database were with high confidence (scores ≥0.9), confirming the high validity of the identified cross-links for protein structural mapping and PPI analysis. This study demonstrates that O-MICROFASP is a universal and efficient method for proteome-wide XL-MS analysis of microscale samples with high sensitivity and reliability.


  • Multidimensional separation methods for in-depth proteome profiling of low-microgram samples

    by Gang Lu, Guojin Ying, Yu He, Yang Li, Perry G Wang, Zhenbin Zhang

    Tweetable abstract Multidimensional separation methods with improved sensitivity and peak capacity and throughput allow in-depth proteome profiling of low-microgram samples.

  • A Facile and High-Sensitivity Method for Determining Proteinogenic Amino Acid Enantiomers by Integrating Chiral Phosphinate Derivatizing, 31P NMR and Parallel Reaction Monitoring

    by Yoapoing Shi, Dipendu Mandal, Zhenbin Zhang, Yufen Zhao

    Here, we have documented a new protocol to determine D/L amino acids by derivatizing amino acids via a chiral phosphinate. (RP)-L- Menthyl phenylphosphinate was able to bond both primary and secondary amines, as well as improve the sensitivity of analytes in MS. Eighteen pairs of amino acids were successfully labeled except for Cys which has a thiol group on the side chain, and the chirality of amino acids can be discriminated by 31P NMR. Seventeen pairs of amino acids were separated by a C18 column within 45 min of elution, and resolution values ranged from 2.01 to 10.76. The lowest limit of detection was 10 pM acquired at parallel reaction monitoring, in which two factors collectively contributed that the ability of protonation of phosphine oxide and the sensitivity of parallel reaction monitoring. Chiral phosphine oxides might be a promising tool in future chiral metabolomics.


  • Seamlessly Integrated Miniaturized Filter-Aided Sample Preparation Method to Fractionation Techniques for Fast, Loss-Less, and In-Depth Proteomics Analysis of 1 ÎĽg of Cell Lysates at Low Cost

    by Zhenbin Zhang, Norman J. Dovichi

    We report an integrated platform that enabled a seamlessly coupling miniaturized filter-aided sample preparation (MICROFASP) method to high-pH reversed phase (RP) or strong cation exchange (SCX) microreactors for low-loss sample preparation and fractionation of 1 ÎĽg of cell lysates prior to LC-ESI-MS/MS analysis. Due to the reduced size of the microreactor, only 5 ÎĽL of buffer volume is required to generate each fraction, which speeds both elution and lyophilization. The fraction was directly eluted into an autosampler insert vial for LC-MS analysis to reduce sample transfer steps and minimize sample loss as well as contamination. The flow-through sample generated during the loading step was also collected and analyzed. The integrated platform generated 48,890 unique peptides and 4723 protein groups from 1 ÎĽg of a K562 cell lysate using MICROFASP and C18 microreactor-based high-pH RP fractionation methods, which are comparable with the state-of-the-art result using in-StageTip sample preparation and nanoflow RPLC-based fractionation methods but with a significant reduction in cost and time. Both pH gradient elution and salt gradient elution approaches provide high reproducibility for the SCX microreactor-based fractionation method. This integrated platform has significant potential in deep proteomics analysis of mass-limited samples with reduced time and equipment requirements.