Adriana Esguerra Arce
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Adriana Esguerra Arce has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Johanna Esguerra-Arce
Decanatura de Ingenería Industrial, Universidad Escuela Colombiana de Ingeniería Julio Garavito
3 shared publications - David Leonardo Blanco Estupiñán
Universidad Escuela Colombiana de Ingeniería Julio Garavito
1 shared publication - Duvan Vega-Ortiz
CIMSER, Ingeniería Industrial, Escuela Colombiana de Ingeniería Julio Garavito
1 shared publication - Johanna Gisell Tirado González
Decanatura de Ingenería Industrial, Universidad Escuela Colombiana de Ingeniería Julio Garavito
1 shared publication - Juan Guillermo Castano
Universidad de Antioquía
1 shared publication - Juan Guillermo Ortiz Martínez
Department of Orthopedics and Traumatology, Universidad de La Sabana, Chía 250001, Colombia
1 shared publication
Latest Publications
- Open Access
- 16 June 2025
- Published by Universitat Politecnica de Valencia
- p. 1-10
Comportamiento frente al envejecimiento de piezas obtenidas con polvo de molienda de viruta de aleación de Al 7075
Este trabajo presenta el desarrollo de compactos de aleación Al-7075 a partir de viruta reciclada mediante procesos de molienda, compactación, sinterización, temple y envejecimiento. Las virutas se limpiaron, secaron y molieron en atmósfera de aire usando un molino de bolas con cuerpos moledores de zirconia. El polvo obtenido fue tamizado y caracterizado por ICP-OES, extracción en caliente con gas de arrastre y DRX. Luego, se compactó en una matriz de acero H13 y se sinterizó a 630 °C en atmósfera de argón. Las muestras resultantes se evaluaron mediante dureza, DRX y SEM. Posteriormente, se sometieron a tratamiento térmico de solubilización a 545 °C seguido de temple en agua con sal. Finalmente, se envejecieron a 210 °C por tiempos de 0.5 a 10 horas. La caracterización estructural reveló que los óxidos amorfos presentes en el polvo (Al₂O₃ y MgO) cristalizan durante la sinterización. En el temple aparece espinela (MgAl₂O₄) debido a la reacción entre MgO y Al₂O₃. El envejecimiento a 0.5 h promueve la formación de precipitados coherentes, lo cual maximiza la dureza. Sin embargo, tras 10 h, estos pierden coherencia y la dureza disminuye ligeramente. Este enfoque demuestra la viabilidad de usar subproductos industriales para desarrollar materiales funcionales mediante pulvimetalurgia.
- 16 June 2025
- Published by Universitat Politecnica de Valencia
- p. 1-10
Open AccessComportamiento frente al envejecimiento de piezas obtenidas con polvo de molienda de viruta de aleación de Al 7075
Este trabajo presenta el desarrollo de compactos de aleación Al-7075 a partir de viruta reciclada mediante procesos de molienda, compactación, sinterización, temple y envejecimiento. Las virutas se limpiaron, secaron y molieron en atmósfera de aire usando un molino de bolas con cuerpos moledores de zirconia. El polvo obtenido fue tamizado y caracterizado por ICP-OES, extracción en caliente con gas de arrastre y DRX. Luego, se compactó en una matriz de acero H13 y se sinterizó a 630 °C en atmósfera de argón. Las muestras resultantes se evaluaron mediante dureza, DRX y SEM. Posteriormente, se sometieron a tratamiento térmico de solubilización a 545 °C seguido de temple en agua con sal. Finalmente, se envejecieron a 210 °C por tiempos de 0.5 a 10 horas. La caracterización estructural reveló que los óxidos amorfos presentes en el polvo (Al₂O₃ y MgO) cristalizan durante la sinterización. En el temple aparece espinela (MgAl₂O₄) debido a la reacción entre MgO y Al₂O₃. El envejecimiento a 0.5 h promueve la formación de precipitados coherentes, lo cual maximiza la dureza. Sin embargo, tras 10 h, estos pierden coherencia y la dureza disminuye ligeramente. Este enfoque demuestra la viabilidad de usar subproductos industriales para desarrollar materiales funcionales mediante pulvimetalurgia.
- Open Access
- 28 July 2021
- Published by Universidad Nacional de Colombia in DYNA
- Vol. 88 (218) , 24-33
Influence of porosity on the biomimetic growing patterns of bonelike apatite on the surface of calcium phosphate – calcium titanate – alumina compounds
Biomaterials are increasingly used for bone tissue regeneration because of their potential to overcome the morbidity caused by autologous bone grafts and allografts. A combination of properties is required, as biocompatibility, osteoconductivity, good mechanical strength and fracture toughness. In this research, a compound of alumina matrix with calcium titanate and calcium phosphate is proposed. Magnesium stearate was used as porogen agent. The aim of this research was to evaluate the effect of porosity on the crystalline phases formed, as well as the growing pattern and types of calcium phosphates formed after soaking in Hanks’ solution. It was found that the resultant porosity does affect the crystalline phases formed after sintering. It was also found that hydroxyapatite and octacalcium phosphate precipitates after soaking in Hank’s solution, and that the porosity affects the growing pattern.
- 28 July 2021
- Published by Universidad Nacional de Colombia in DYNA
- Vol. 88 (218) , 24-33
Open AccessInfluence of porosity on the biomimetic growing patterns of bonelike apatite on the surface of calcium phosphate – calcium titanate – alumina compounds
Biomaterials are increasingly used for bone tissue regeneration because of their potential to overcome the morbidity caused by autologous bone grafts and allografts. A combination of properties is required, as biocompatibility, osteoconductivity, good mechanical strength and fracture toughness. In this research, a compound of alumina matrix with calcium titanate and calcium phosphate is proposed. Magnesium stearate was used as porogen agent. The aim of this research was to evaluate the effect of porosity on the crystalline phases formed, as well as the growing pattern and types of calcium phosphates formed after soaking in Hanks’ solution. It was found that the resultant porosity does affect the crystalline phases formed after sintering. It was also found that hydroxyapatite and octacalcium phosphate precipitates after soaking in Hank’s solution, and that the porosity affects the growing pattern.
- Open Access
- 23 March 2021
- Published by Universidad de Antioquia in Revista Facultad de Ingeniería Universidad de Antioquia
- No. 100,p. 35-47
A comparative surface analysis of explanted hip prostheses: stainless steel and Co-Cr alloy versus titanium alloy
The introduction of modular design in total hip arthroplasty has enabled the use of different materials in one single configuration and the adjustment of the prosthesis to the patient’s body, and facilitated medical revisions. However, modularity leads to the presence of new interfaces created between pieces in contact, raising the issue of degradation. Tribocorrosion phenomena have been identified as the main degradation mechanism due to the mechanical, chemical, and electrochemical conditions acting on the materials. In addition, conditions inside the human body are unclear, regarding electrochemical settings and the interaction between the electrochemical and mechanical action. This work is focused on the degradation of monopolar hip joint implants made from biomedical alloys such as stainless steel, Ti, and CoCr alloys. Three cases are presented and analyzed in terms of the degradation level along the trunnion length. Surface analysis done on a titanium trunnion showed a significant ploughing on the distal part, compared to what was found for stainless Steel and cobalt-chromium alloys, which can produce a stuck in this area. Meanwhile, in the proximal part, wear debris is found, which suggests more movement in the internal part. Although few debris particles were identified in CoCr trunnion, a large amount of material inside the contact was observed. This could be related to the ploughing generated in the distal thread pattern, which allowed the material to come inside and outside the contact.
- 23 March 2021
- Published by Universidad de Antioquia in Revista Facultad de Ingeniería Universidad de Antioquia
- No. 100,p. 35-47
Open AccessA comparative surface analysis of explanted hip prostheses: stainless steel and Co-Cr alloy versus titanium alloy
The introduction of modular design in total hip arthroplasty has enabled the use of different materials in one single configuration and the adjustment of the prosthesis to the patient’s body, and facilitated medical revisions. However, modularity leads to the presence of new interfaces created between pieces in contact, raising the issue of degradation. Tribocorrosion phenomena have been identified as the main degradation mechanism due to the mechanical, chemical, and electrochemical conditions acting on the materials. In addition, conditions inside the human body are unclear, regarding electrochemical settings and the interaction between the electrochemical and mechanical action. This work is focused on the degradation of monopolar hip joint implants made from biomedical alloys such as stainless steel, Ti, and CoCr alloys. Three cases are presented and analyzed in terms of the degradation level along the trunnion length. Surface analysis done on a titanium trunnion showed a significant ploughing on the distal part, compared to what was found for stainless Steel and cobalt-chromium alloys, which can produce a stuck in this area. Meanwhile, in the proximal part, wear debris is found, which suggests more movement in the internal part. Although few debris particles were identified in CoCr trunnion, a large amount of material inside the contact was observed. This could be related to the ploughing generated in the distal thread pattern, which allowed the material to come inside and outside the contact.