Fevzi Akkan
Fevzi Akkan has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ebru Gorgun
Department of Ophthalmology, Dunyagoz Eye Hospital, Istanbul, Türkiye
2 shared publications B. I. Sezgin Akcay
Augenklinik Ümraniye, Lehr- und Forschungs-Krankenhaus, Istanbul, Türkei
1 shared publication- Dincer Dinc
Consultant Ophthalmologist, Department of Vitreoretinal Surgery, Dunyagoz Eye Hospital, Istanbul, Turkey
1 shared publication - Emre Ayintap
Department of Ophthalmology, Izmir City Hospital, Izmir, Turkey
1 shared publication J. C. Umurhan Akkan
Medizinische Fakultät, Augenklinik, Bezmialem Vakif Universität, Istanbul, Türkei
1 shared publicationK. Tuncer
Medizinische Fakultät, Augenklinik, Bezmialem Vakif Universität, Istanbul, Türkei
1 shared publication
Latest Publications
- Open Access
- 10 July 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (28) , e49704
Sector-dependent device discordance of RNFL measurements: A prospective cross-sectional study of cross-platform variability and interchangeability in glaucoma monitoring
This study aimed to characterize intra-device repeatability and sector-dependent inter-device variability of peripapillary retinal nerve fiber layer (RNFL) measurements across 5 optical coherence tomography (OCT) platforms and define the concept of sector-dependent device discordance, the non-uniform distribution of inter-device measurement bias across anatomical RNFL sectors. This prospective cross-sectional study included 38 healthy participants who underwent peripapillary RNFL imaging using 5 OCT devices: Heidelberg Spectralis, TowardPi BMIZAR 400 kHz swept-source OCT, Huvitz HOCT-1/1F, NIDEK RS-1 Glauvas, and Topcon Maestro 2. RNFL thickness was analyzed in the superior, nasal, inferior, and temporal sectors, as well as global mean thickness. Three consecutive measurements were obtained for each eye with each device to assess intra-device repeatability. Repeatability was evaluated using repeated-measures analysis of variance. Inter-device reliability was assessed using intraclass correlation coefficients, with Heidelberg Spectralis as the reference. Agreement between devices was further evaluated using Bland–Altman analysis. Excellent intra-device repeatability was documented across all platforms. However, marked inter-device variability demonstrated sector-dependent patterns: global RNFL measurements showed moderate agreement (intraclass correlation coefficient: 0.346–0.805), while nasal and temporal sectors exhibited disproportionately higher variability (absolute percentage error up to 20.76% in the nasal sector; limits of agreement width ranging from 20.23% to 35.52% in temporal). Bland–Altman analyses revealed device-specific bias signatures (Huvitz HOCT-1/1F: −8.17% global bias; NIDEK RS-1 Glauvas: +10.59%; Topcon Maestro 2: −4.47%), indicating systematic, reproducible platform-inherent differences rather than random measurement noise. While intra-device repeatability is excellent, inter-device RNFL measurements remain substantially discordant, particularly in nasal and temporal sectors, where absolute percentage error reaches up to 20.76% and limits of agreement exceed 35%, a phenomenon termed sector-dependent device discordance. Global RNFL measurements may appear concordant while sectoral measurements diverge, creating a theoretically plausible risk for false progression detection, pending validation in glaucomatous eyes. RNFL measurements are not interchangeable across platforms and are particularly unreliable for sector-specific assessment. Device-consistent monitoring is essential for glaucoma follow-up; multicenter studies and device switching scenarios warrant platform-specific normalization strategies.
- 10 July 2026
- Published by Wolters Kluwer Health in Medicine
- Vol. 105 (28) , e49704
Open AccessSector-dependent device discordance of RNFL measurements: A prospective cross-sectional study of cross-platform variability and interchangeability in glaucoma monitoring
This study aimed to characterize intra-device repeatability and sector-dependent inter-device variability of peripapillary retinal nerve fiber layer (RNFL) measurements across 5 optical coherence tomography (OCT) platforms and define the concept of sector-dependent device discordance, the non-uniform distribution of inter-device measurement bias across anatomical RNFL sectors. This prospective cross-sectional study included 38 healthy participants who underwent peripapillary RNFL imaging using 5 OCT devices: Heidelberg Spectralis, TowardPi BMIZAR 400 kHz swept-source OCT, Huvitz HOCT-1/1F, NIDEK RS-1 Glauvas, and Topcon Maestro 2. RNFL thickness was analyzed in the superior, nasal, inferior, and temporal sectors, as well as global mean thickness. Three consecutive measurements were obtained for each eye with each device to assess intra-device repeatability. Repeatability was evaluated using repeated-measures analysis of variance. Inter-device reliability was assessed using intraclass correlation coefficients, with Heidelberg Spectralis as the reference. Agreement between devices was further evaluated using Bland–Altman analysis. Excellent intra-device repeatability was documented across all platforms. However, marked inter-device variability demonstrated sector-dependent patterns: global RNFL measurements showed moderate agreement (intraclass correlation coefficient: 0.346–0.805), while nasal and temporal sectors exhibited disproportionately higher variability (absolute percentage error up to 20.76% in the nasal sector; limits of agreement width ranging from 20.23% to 35.52% in temporal). Bland–Altman analyses revealed device-specific bias signatures (Huvitz HOCT-1/1F: −8.17% global bias; NIDEK RS-1 Glauvas: +10.59%; Topcon Maestro 2: −4.47%), indicating systematic, reproducible platform-inherent differences rather than random measurement noise. While intra-device repeatability is excellent, inter-device RNFL measurements remain substantially discordant, particularly in nasal and temporal sectors, where absolute percentage error reaches up to 20.76% and limits of agreement exceed 35%, a phenomenon termed sector-dependent device discordance. Global RNFL measurements may appear concordant while sectoral measurements diverge, creating a theoretically plausible risk for false progression detection, pending validation in glaucomatous eyes. RNFL measurements are not interchangeable across platforms and are particularly unreliable for sector-specific assessment. Device-consistent monitoring is essential for glaucoma follow-up; multicenter studies and device switching scenarios warrant platform-specific normalization strategies.
- Open Access
- 30 May 2026
- Published by Springer Nature in BMC Medical Imaging
- Vol. 26 (1)
Peripheral instability gradient in macular thickness measurements across five optical coherence tomography systems: a prospective cross-sectional study of inter-device agreement and clinical monitoring risk
Background: Cross-platform variability in optical coherence tomography (OCT) macular thickness measurements poses a clinically meaningful challenge for longitudinal patient assessment, particularly when patients are imaged on different devices over time. This study characterizes intra-device repeatability and inter-device agreement across five contemporary OCT systems, and introduces the Peripheral Instability Gradient (PIG)—the progressive deterioration in cross-device measurement concordance from the foveal center outward across ETDRS-defined macular zones. Methods: In this prospective, cross-sectional study, 38 healthy adults underwent macular imaging with five OCT devices: HRA Spectralis (Heidelberg Engineering), BMIZAR (TowardPi, 400 kHz swept-source OCTA), TOPCON Maestro 2, NIDEK RS-1 Glauvas, and HUVITZ HOCT-1/1F. Macular thickness was measured in the central 1-mm ETDRS subfield and the 3-mm and 6-mm inner rings (superior, nasal, inferior, and temporal sectors). Three consecutive scans were acquired per device during a single visit by a single experienced operator. Intra-device repeatability was assessed using ICC(3,1) and repeated-measures ANOVA with Bonferroni correction. Inter-device agreement was evaluated using ICC(2,1), Bland–Altman analysis, and absolute percentage error (APE). HRA-anchored comparisons were used for directional bias interpretation, and all 10 direct pairwise device comparisons were additionally performed as cross-validation. Results: All devices demonstrated excellent within-device repeatability (ICC > 0.85 across all regions). Inter-device agreement was strongly location-dependent, with PIG: ICC values declining from the central 1-mm subfield (HRA vs. HUVITZ: 0.942; HRA vs. NIDEK: 0.902) to the 6-mm ring (ICC < 0.40 for most pairs). This represents a relative decline of 40–67%. Central thickness ranged from 227.85 μm (TOPCON) to 290.73 μm (BMIZAR). Device-specific systematic biases were identified: BMIZAR overestimated HRA by a mean relative bias of 10.98%, and TOPCON underestimated HRA by a mean relative bias 13.65%, while HUVITZ (+ 2.60%) and NIDEK (+ 3.64%) showed smaller relative deviations (all biases as HRA minus comparator). Limits of agreement widened by a relative 30–50% from central to peripheral rings. Median APE was lowest for HUVITZ (2.39%) and highest for TOPCON (12.23%). Conclusions: Macular thickness measurements are highly repeatable within individual OCT systems but are not interchangeable across devices, with disagreement amplifying progressively toward peripheral macular zones. The Peripheral Instability Gradient demonstrates that cross-device follow-up carries the greatest risk in parafoveal and perifoveal monitoring. To ensure reliable longitudinal assessment, clinicians should maintain device consistency; when switching is unavoidable, device-specific baselines should be established and calibration adjustments applied.
- 30 May 2026
- Published by Springer Nature in BMC Medical Imaging
- Vol. 26 (1)
Open AccessPeripheral instability gradient in macular thickness measurements across five optical coherence tomography systems: a prospective cross-sectional study of inter-device agreement and clinical monitoring risk
Background: Cross-platform variability in optical coherence tomography (OCT) macular thickness measurements poses a clinically meaningful challenge for longitudinal patient assessment, particularly when patients are imaged on different devices over time. This study characterizes intra-device repeatability and inter-device agreement across five contemporary OCT systems, and introduces the Peripheral Instability Gradient (PIG)—the progressive deterioration in cross-device measurement concordance from the foveal center outward across ETDRS-defined macular zones. Methods: In this prospective, cross-sectional study, 38 healthy adults underwent macular imaging with five OCT devices: HRA Spectralis (Heidelberg Engineering), BMIZAR (TowardPi, 400 kHz swept-source OCTA), TOPCON Maestro 2, NIDEK RS-1 Glauvas, and HUVITZ HOCT-1/1F. Macular thickness was measured in the central 1-mm ETDRS subfield and the 3-mm and 6-mm inner rings (superior, nasal, inferior, and temporal sectors). Three consecutive scans were acquired per device during a single visit by a single experienced operator. Intra-device repeatability was assessed using ICC(3,1) and repeated-measures ANOVA with Bonferroni correction. Inter-device agreement was evaluated using ICC(2,1), Bland–Altman analysis, and absolute percentage error (APE). HRA-anchored comparisons were used for directional bias interpretation, and all 10 direct pairwise device comparisons were additionally performed as cross-validation. Results: All devices demonstrated excellent within-device repeatability (ICC > 0.85 across all regions). Inter-device agreement was strongly location-dependent, with PIG: ICC values declining from the central 1-mm subfield (HRA vs. HUVITZ: 0.942; HRA vs. NIDEK: 0.902) to the 6-mm ring (ICC < 0.40 for most pairs). This represents a relative decline of 40–67%. Central thickness ranged from 227.85 μm (TOPCON) to 290.73 μm (BMIZAR). Device-specific systematic biases were identified: BMIZAR overestimated HRA by a mean relative bias of 10.98%, and TOPCON underestimated HRA by a mean relative bias 13.65%, while HUVITZ (+ 2.60%) and NIDEK (+ 3.64%) showed smaller relative deviations (all biases as HRA minus comparator). Limits of agreement widened by a relative 30–50% from central to peripheral rings. Median APE was lowest for HUVITZ (2.39%) and highest for TOPCON (12.23%). Conclusions: Macular thickness measurements are highly repeatable within individual OCT systems but are not interchangeable across devices, with disagreement amplifying progressively toward peripheral macular zones. The Peripheral Instability Gradient demonstrates that cross-device follow-up carries the greatest risk in parafoveal and perifoveal monitoring. To ensure reliable longitudinal assessment, clinicians should maintain device consistency; when switching is unavoidable, device-specific baselines should be established and calibration adjustments applied.
- Open Access
- 1 December 2021
- Published by Pharmamedix India Publication Pvt Ltd in Asian Journal of Medical Sciences
- Vol. 12 (12) , 39-43
A novel design silicone oil removal cannula
Background: Silicone oil, which is one of the most commonly used endotamponades in vitreoretinal surgery, is removed after a certain period of time in most cases. In this study, we present our results with a unique cannula that provides effective and safe silicone oil removal. Aims and Objectives: To assess the aids and success of silicone oil removal with a novel 23-gauge cannula for the patients who underwent pars plana vitrectomy and silicone oil injection before. Materials and Methods: 72 eyes of 64 patients who operated by the same surgeon (FA) between May 2017 and May 2019 were involved in the study. The primary indications were proliferative diabetic retinopathy in 46 (63.9%) eyes and retinal detachment in 26 (36.1%) eyes. Phacoemulsification and intraocular lens implantation (23 eyes), membrane peeling (23 eyes), internal limiting membrane peeling (5 eyes), and argon laser endo-photocoagulation (37 eyes) performed in the same session. Furthermore, perfluorocarbon remnants aspirated in 9 eyes and 17 eyes needed suturing. Descriptive statistical analyses achieved by SPSS 10.5 statistical software. Results: The mean follow-up time was 11.7 + 2.5 months (between 3 and 23 months), and the mean age was 61.4 + 8.52 years (between 44 and 69 years). 1000 centistokes (cSt) silicone oil was removed from 61 (84.7%) eyes, and 5000 cSt silicone oil was removed from 11 (15.3%) eyes. The mean removal time was 2.04 + 0.1 min for 1000 cSt silicone oil and 5.11 + 0.3 min for 5000 cSt silicone oil. 4 re-detachment and 3 vitreous hemorrhage observed in follow-up period. Post-operative silicone oil remnants were not detected in any patient. Conclusion: The unique 23-gauge cannula provides silicone oil removal without any conjunctival cut-down and sclerotomy enlargement. Thus, it reduces the duration of surgery and post-operative recovery period.
- 1 December 2021
- Published by Pharmamedix India Publication Pvt Ltd in Asian Journal of Medical Sciences
- Vol. 12 (12) , 39-43
Open AccessA novel design silicone oil removal cannula
Background: Silicone oil, which is one of the most commonly used endotamponades in vitreoretinal surgery, is removed after a certain period of time in most cases. In this study, we present our results with a unique cannula that provides effective and safe silicone oil removal. Aims and Objectives: To assess the aids and success of silicone oil removal with a novel 23-gauge cannula for the patients who underwent pars plana vitrectomy and silicone oil injection before. Materials and Methods: 72 eyes of 64 patients who operated by the same surgeon (FA) between May 2017 and May 2019 were involved in the study. The primary indications were proliferative diabetic retinopathy in 46 (63.9%) eyes and retinal detachment in 26 (36.1%) eyes. Phacoemulsification and intraocular lens implantation (23 eyes), membrane peeling (23 eyes), internal limiting membrane peeling (5 eyes), and argon laser endo-photocoagulation (37 eyes) performed in the same session. Furthermore, perfluorocarbon remnants aspirated in 9 eyes and 17 eyes needed suturing. Descriptive statistical analyses achieved by SPSS 10.5 statistical software. Results: The mean follow-up time was 11.7 + 2.5 months (between 3 and 23 months), and the mean age was 61.4 + 8.52 years (between 44 and 69 years). 1000 centistokes (cSt) silicone oil was removed from 61 (84.7%) eyes, and 5000 cSt silicone oil was removed from 11 (15.3%) eyes. The mean removal time was 2.04 + 0.1 min for 1000 cSt silicone oil and 5.11 + 0.3 min for 5000 cSt silicone oil. 4 re-detachment and 3 vitreous hemorrhage observed in follow-up period. Post-operative silicone oil remnants were not detected in any patient. Conclusion: The unique 23-gauge cannula provides silicone oil removal without any conjunctival cut-down and sclerotomy enlargement. Thus, it reduces the duration of surgery and post-operative recovery period.
- 29 October 2015
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 232 (10) , 1190-1197
Dynamische Konturtonometrie und Goldmann-Tonometrie: Differenzen der Druckwerte zwischen Augen mit und ohne Glaukomschaden bei dünner Hornhaut
Hintergrund: Die durch eine dynamische Konturtonometrie (dynamic contour tonometry, DCT, Pascal-Messung) und Goldmann-Applanationstonometrie (GAT) erhaltenen Messdifferenzen des intraokularen Druckes (IOD) bei Patienten mit dünner Hornhaut sollten untersucht und mit strukturellen und funktionellen Parametern des Glaukomschadens korreliert werden. Patienten und Methoden: 130 Augen von 130 Teilnehmern mit einer zentralen Hornhautdicke von weniger als 500 µm wurden in dieser Querschnitts-Beobachtungsstudie 5 Gruppen zugeteilt: 52 Augen mit primärem Offenwinkelglaukom (POAG), 19 Augen mit Normaldruckglaukom (NTG), 27 Augen mit okularer Hypertension (OHT), 21 Teilnehmer mit Verdacht auf Glaukom (GS) und 11 gesunde Teilnehmer. Die Messungen wurden verblindet mit GAT und DCT durchgeführt. Die korrigierten GAT-Werte nach der zentralen Hornhautdicke (CCT), die Differenz zwischen DCT und GAT (ΔIOD = DCT−GAT) und der korrigierte ΔIOD (korrigierter ΔIOD = DCT−korrigierter GAT) wurden berechnet. Für die statistische Auswertung wurden das Alter, die mittlere Abweichung (mean deviation, MD) aus der letzten verlässlichen Gesichtsfelduntersuchung, die durchschnittliche Dicke der retinalen Nervenfaserschicht (RNFL), das Verhältnis zwischen Exkavations- und Papillenfläche (cup-to-disc ratio, CDR), die okulare Pulsamplitude (OPA) und der Behandlungsstatus aufgenommen. Ergebnisse: Bezogen auf alle Patienten (n = 130) betrugen die mittleren DCT-, GAT- und korrigierten GAT-Werte 17,6 ± 3,4 mmHg, 13,2 ± 3,8 mmHg und 15,9 ± 3,9 mmHg. Die ΔIOD- und korrigierten ΔIOD-Werte betrugen 4,4 ± 2 mmHg bzw. 1,7 ± 2 mmHg. Der ΔIOD korrelierte negativ mit der MD (rs = − 0,32; p < 0,0001) und durchschnittlichen RNFL-Dicke (r = − 0,46; p < 0,0001) und positiv mit dem CDR (rs = 0,50; p < 0,0001). Der mittels GAT gemessene mittlere IOD zeigt eine statistisch signifikante Differenz zwischen Augen mit Glaukom (n = 71, POAG und NTG) und Augen ohne Schaden (n = 59; OHT, GS und gesunde Augen, p < 0,0001), während der durch eine DCT gemessene mittlere IOD keine Differenz zeigte (p = 0,935). Die mittleren ΔIOD-Werte lagen in der glaukomatösen Gruppe statistisch signifikant höher, mit und ohne Korrektion für CCT (p < 0,001). Die OPA und die Glaukomdiagnose sagten statistisch signifikant den ΔIOD voraus (R2 = 0,41; F2.127 = 47,46; p < 0,0001). Schlussfolgerungen: Bei glaukomatösen Augen mit dünner Hornhaut wurde eine größere Unterbewertung des IOD durch eine GAT beobachtet. Eine DCT bei Patienten mit dünner Hornhaut könnte dazu beitragen, eine aggressivere Behandlung in die Wege zu leiten, um progredienten Schäden vorzubeugen. Background: To examine the differences in intraocular pressure (IOP) measurements obtained with Goldmann applanation tonometry (GAT) and Pascal dynamic contour tonometry (DCT) in subjects with thin corneas and to correlate these with structural and functional parameters of glaucoma damage. Patients and Methods: One hundred and thirty participants (130 eyes) with central corneal thickness lower than 500 µm were included in five groups in this cross-sectional observational study: 52 eyes with primary open angle glaucoma (POAG), 19 eyes with normal tension glaucoma (NTG), 27 eyes with ocular hypertension (OHT), 21 participants suspected of having glaucoma (GS), and 11 healthy subjects. The measurements were obtained with GAT and DCT in a masked fashion. The corrected GAT−IOP for central corneal thickness (CCT), the difference between DCT and GAT (ΔIOP = DCT−GAT) and corrected ΔIOP (corrected ΔIOP = DCT−corrected GAT) were calculated. Age, mean deviation (MD) from the most recent reliable visual field examination, average retinal nerve fibre layer thickness (RNFL), cup-to-disc ratio (CDR), ocular pulse amplitude (OPA), and treatment status were recorded for statistical analysis. Results: In all of the subjects (n = 130), the mean DCT, GAT and corrected GAT values were 17.6 ± 3.4 mmHg, 13.2 ± 3.8 mmHg, and 15.5 ± 2.1 mmHg, respectively. ΔIOP and corrected ΔIOP were 4.4 ± 2 mmHg and 1.7 ± 2 mmHg, respectively. ΔIOP was correlated negatively with MD (rs = −0.32, p < 0.0001) and average RNFL thickness (r = −0.46, p < 0.0001) and positively with CDR (rs = 0.50, p < 0.0001). The mean IOP measured by GAT differed statistically significantly between eyes with glaucoma (n = 71, POAG and NTG) and eyes without damage (n = 59; OHT, GS, and healthy) (p < 0.0001), whereas the mean IOP by DCT did not (p = 0.935). The mean ΔIOP values were also statistically significantly higher in the glaucomatous group, with and without correction for CCT (p < 0.001). OPA and glaucoma diagnoses statistically significantly predicted ΔIOP (R2 = 0.41, F2.127 = 47.46, p < 0.0001). Conclusion: Greater underestimation of IOP by GAT was observed in the glaucomatous eyes with thin corneas. Performing DCT on patients with thin corneas might be advantageous in establishing the need for more aggressive treatment.
- 29 October 2015
- Published by Georg Thieme Verlag KG in Klinische Monatsblätter für Augenheilkunde
- Vol. 232 (10) , 1190-1197
Dynamische Konturtonometrie und Goldmann-Tonometrie: Differenzen der Druckwerte zwischen Augen mit und ohne Glaukomschaden bei dünner Hornhaut
Hintergrund: Die durch eine dynamische Konturtonometrie (dynamic contour tonometry, DCT, Pascal-Messung) und Goldmann-Applanationstonometrie (GAT) erhaltenen Messdifferenzen des intraokularen Druckes (IOD) bei Patienten mit dünner Hornhaut sollten untersucht und mit strukturellen und funktionellen Parametern des Glaukomschadens korreliert werden. Patienten und Methoden: 130 Augen von 130 Teilnehmern mit einer zentralen Hornhautdicke von weniger als 500 µm wurden in dieser Querschnitts-Beobachtungsstudie 5 Gruppen zugeteilt: 52 Augen mit primärem Offenwinkelglaukom (POAG), 19 Augen mit Normaldruckglaukom (NTG), 27 Augen mit okularer Hypertension (OHT), 21 Teilnehmer mit Verdacht auf Glaukom (GS) und 11 gesunde Teilnehmer. Die Messungen wurden verblindet mit GAT und DCT durchgeführt. Die korrigierten GAT-Werte nach der zentralen Hornhautdicke (CCT), die Differenz zwischen DCT und GAT (ΔIOD = DCT−GAT) und der korrigierte ΔIOD (korrigierter ΔIOD = DCT−korrigierter GAT) wurden berechnet. Für die statistische Auswertung wurden das Alter, die mittlere Abweichung (mean deviation, MD) aus der letzten verlässlichen Gesichtsfelduntersuchung, die durchschnittliche Dicke der retinalen Nervenfaserschicht (RNFL), das Verhältnis zwischen Exkavations- und Papillenfläche (cup-to-disc ratio, CDR), die okulare Pulsamplitude (OPA) und der Behandlungsstatus aufgenommen. Ergebnisse: Bezogen auf alle Patienten (n = 130) betrugen die mittleren DCT-, GAT- und korrigierten GAT-Werte 17,6 ± 3,4 mmHg, 13,2 ± 3,8 mmHg und 15,9 ± 3,9 mmHg. Die ΔIOD- und korrigierten ΔIOD-Werte betrugen 4,4 ± 2 mmHg bzw. 1,7 ± 2 mmHg. Der ΔIOD korrelierte negativ mit der MD (rs = − 0,32; p < 0,0001) und durchschnittlichen RNFL-Dicke (r = − 0,46; p < 0,0001) und positiv mit dem CDR (rs = 0,50; p < 0,0001). Der mittels GAT gemessene mittlere IOD zeigt eine statistisch signifikante Differenz zwischen Augen mit Glaukom (n = 71, POAG und NTG) und Augen ohne Schaden (n = 59; OHT, GS und gesunde Augen, p < 0,0001), während der durch eine DCT gemessene mittlere IOD keine Differenz zeigte (p = 0,935). Die mittleren ΔIOD-Werte lagen in der glaukomatösen Gruppe statistisch signifikant höher, mit und ohne Korrektion für CCT (p < 0,001). Die OPA und die Glaukomdiagnose sagten statistisch signifikant den ΔIOD voraus (R2 = 0,41; F2.127 = 47,46; p < 0,0001). Schlussfolgerungen: Bei glaukomatösen Augen mit dünner Hornhaut wurde eine größere Unterbewertung des IOD durch eine GAT beobachtet. Eine DCT bei Patienten mit dünner Hornhaut könnte dazu beitragen, eine aggressivere Behandlung in die Wege zu leiten, um progredienten Schäden vorzubeugen. Background: To examine the differences in intraocular pressure (IOP) measurements obtained with Goldmann applanation tonometry (GAT) and Pascal dynamic contour tonometry (DCT) in subjects with thin corneas and to correlate these with structural and functional parameters of glaucoma damage. Patients and Methods: One hundred and thirty participants (130 eyes) with central corneal thickness lower than 500 µm were included in five groups in this cross-sectional observational study: 52 eyes with primary open angle glaucoma (POAG), 19 eyes with normal tension glaucoma (NTG), 27 eyes with ocular hypertension (OHT), 21 participants suspected of having glaucoma (GS), and 11 healthy subjects. The measurements were obtained with GAT and DCT in a masked fashion. The corrected GAT−IOP for central corneal thickness (CCT), the difference between DCT and GAT (ΔIOP = DCT−GAT) and corrected ΔIOP (corrected ΔIOP = DCT−corrected GAT) were calculated. Age, mean deviation (MD) from the most recent reliable visual field examination, average retinal nerve fibre layer thickness (RNFL), cup-to-disc ratio (CDR), ocular pulse amplitude (OPA), and treatment status were recorded for statistical analysis. Results: In all of the subjects (n = 130), the mean DCT, GAT and corrected GAT values were 17.6 ± 3.4 mmHg, 13.2 ± 3.8 mmHg, and 15.5 ± 2.1 mmHg, respectively. ΔIOP and corrected ΔIOP were 4.4 ± 2 mmHg and 1.7 ± 2 mmHg, respectively. ΔIOP was correlated negatively with MD (rs = −0.32, p < 0.0001) and average RNFL thickness (r = −0.46, p < 0.0001) and positively with CDR (rs = 0.50, p < 0.0001). The mean IOP measured by GAT differed statistically significantly between eyes with glaucoma (n = 71, POAG and NTG) and eyes without damage (n = 59; OHT, GS, and healthy) (p < 0.0001), whereas the mean IOP by DCT did not (p = 0.935). The mean ΔIOP values were also statistically significantly higher in the glaucomatous group, with and without correction for CCT (p < 0.001). OPA and glaucoma diagnoses statistically significantly predicted ΔIOP (R2 = 0.41, F2.127 = 47.46, p < 0.0001). Conclusion: Greater underestimation of IOP by GAT was observed in the glaucomatous eyes with thin corneas. Performing DCT on patients with thin corneas might be advantageous in establishing the need for more aggressive treatment.