Yves Lucas
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yves Lucas has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Sylvie Treuillet
PRISME, Université d'Orléans, Orleans, France
8 shared publications - Benjamin Albouy
IUT of Clermont-Ferrand LAIC, Le Puy en Velay, France
3 shared publications - Hazem Wannous
University of Orléans - PRISME / LVR, Bourges, France
3 shared publications - Sylvie Treuillet
University of Clermont-Ferrand, LASMEA, Campus des Cézeaux, 63177 Aubière FRANCE
3 shared publications Dorra Nouri
PRISME Laboratory, University of Orléans, France
2 shared publications- Alamin Mansouri
ImViA Lab, Université Bourgogne Europe, 21078 Dijon, France
1 shared publication
Latest Publications
- 1 May 2026
- Published by Springer Nature
- p. 287-293
Improved Fine Grained Classification of Buildings Using Aerial Images and Deep Learning
- 1 May 2026
- Published by Springer Nature
- p. 287-293
Improved Fine Grained Classification of Buildings Using Aerial Images and Deep Learning
- Open Access
- 10 February 2026
- Published by Elsevier in Knowledge-Based Systems
- Vol. 338
Enhancing concept-based image classification via knowledge reasoning
- 10 February 2026
- Published by Elsevier in Knowledge-Based Systems
- Vol. 338
Open AccessEnhancing concept-based image classification via knowledge reasoning
- 15 January 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 143, 105234
Optical biopsy mapping on endoscopic image mosaics with a marker-free probe
- 15 January 2022
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 143, 105234
Optical biopsy mapping on endoscopic image mosaics with a marker-free probe
- Open Access
- 25 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 157628-157638
Multi-View Data Augmentation to Improve Wound Segmentation on 3D Surface Model by Deep Learning
Wound area segmentation really progressed with the emergence of deep learning, due to its robustness in uncontrolled lighting and no need to design hand-crafted features but two limits have still to be overcome: firstly, its performance relies on the size and quality of the training dataset in the medical field, where data annotation is costly and time-consuming; secondly the accuracy of the segmentation depends highly on the camera distance and angle and moreover perspective effects prevent measuring real surfaces in single views. To address concurrently these two issues, we propose to apply multi-view modeling: an image sequence is acquired around the wound site and enables wound 3D reconstruction. Then, a segmentation step is run to extract roughly the wound from the background in each view and to select the best view with an original strategy. This view provides the most accurate segmentation and the real wound bed area even on non planar wounds. Finally, this segmentation is backprojected in each view to generate a complete set of well annotated real images to reinforce the learning step of the neural network. In our experiments, we compare several strategies to select the best view in the image sequence. The proposed method, tested on a dataset of 270 images, outperforms standard deep learning approach based on a single view, as recorded with DICE index and IoU score which rise respectively from 36.53% to 86.3% and 29.48% to 77.09% for the wound class to achieve an overall DICE and IoU score of 93.04% and 86.61% including background class. These results attest to the robustness of our method and its improved accuracy in the wound segmentation task.
- 25 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 9, 157628-157638
Open AccessMulti-View Data Augmentation to Improve Wound Segmentation on 3D Surface Model by Deep Learning
Wound area segmentation really progressed with the emergence of deep learning, due to its robustness in uncontrolled lighting and no need to design hand-crafted features but two limits have still to be overcome: firstly, its performance relies on the size and quality of the training dataset in the medical field, where data annotation is costly and time-consuming; secondly the accuracy of the segmentation depends highly on the camera distance and angle and moreover perspective effects prevent measuring real surfaces in single views. To address concurrently these two issues, we propose to apply multi-view modeling: an image sequence is acquired around the wound site and enables wound 3D reconstruction. Then, a segmentation step is run to extract roughly the wound from the background in each view and to select the best view with an original strategy. This view provides the most accurate segmentation and the real wound bed area even on non planar wounds. Finally, this segmentation is backprojected in each view to generate a complete set of well annotated real images to reinforce the learning step of the neural network. In our experiments, we compare several strategies to select the best view in the image sequence. The proposed method, tested on a dataset of 270 images, outperforms standard deep learning approach based on a single view, as recorded with DICE index and IoU score which rise respectively from 36.53% to 86.3% and 29.48% to 77.09% for the wound class to achieve an overall DICE and IoU score of 93.04% and 86.61% including background class. These results attest to the robustness of our method and its improved accuracy in the wound segmentation task.
- 1 March 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 8 (02) , 025001-22
Pose estimation of a markerless fiber bundle for endoscopic optical biopsy
Purpose: We present a markerless vision-based method for on-the-fly three-dimensional (3D) pose estimation of a fiberscope instrument to target pathologic areas in the endoscopic view during exploration. Approach: A 2.5-mm-diameter fiberscope is inserted through the endoscope’s operating channel and connected to an additional camera to perform complementary observation of a targeted area such as a multimodal magnifier. The 3D pose of the fiberscope is estimated frame-by-frame by maximizing the similarity between its silhouette (automatically detected in the endoscopic view using a deep learning neural network) and a cylindrical shape bound to a kinematic model reduced to three degrees-of-freedom. An alignment of the cylinder axis, based on Plücker coordinates from the straight edges detected in the image, makes convergence faster and more reliable. Results: The performance on simulations has been validated with a virtual trajectory mimicking endoscopic exploration and on real images of a chessboard pattern acquired with different endoscopic configurations. The experiments demonstrated a good accuracy and robustness of the proposed algorithm with errors of 0.33 ± 0.68 mm in distance position and 0.32 ± 0.11 deg in axis orientation for the 3D pose estimation, which reveals its superiority over previous approaches. This allows multimodal image registration with sufficient accuracy of <3 pixels. Conclusion: Our pose estimation pipeline was executed on simulations and patterns; the results demonstrate the robustness of our method and the potential of fiber-optical instrument image-based tracking for pose estimation and multimodal registration. It can be fully implemented in software and therefore easily integrated into a routine clinical environment.
- 1 March 2021
- Published by SPIE-Intl Soc Optical Eng in Journal of Medical Imaging
- Vol. 8 (02) , 025001-22
Pose estimation of a markerless fiber bundle for endoscopic optical biopsy
Purpose: We present a markerless vision-based method for on-the-fly three-dimensional (3D) pose estimation of a fiberscope instrument to target pathologic areas in the endoscopic view during exploration. Approach: A 2.5-mm-diameter fiberscope is inserted through the endoscope’s operating channel and connected to an additional camera to perform complementary observation of a targeted area such as a multimodal magnifier. The 3D pose of the fiberscope is estimated frame-by-frame by maximizing the similarity between its silhouette (automatically detected in the endoscopic view using a deep learning neural network) and a cylindrical shape bound to a kinematic model reduced to three degrees-of-freedom. An alignment of the cylinder axis, based on Plücker coordinates from the straight edges detected in the image, makes convergence faster and more reliable. Results: The performance on simulations has been validated with a virtual trajectory mimicking endoscopic exploration and on real images of a chessboard pattern acquired with different endoscopic configurations. The experiments demonstrated a good accuracy and robustness of the proposed algorithm with errors of 0.33 ± 0.68 mm in distance position and 0.32 ± 0.11 deg in axis orientation for the 3D pose estimation, which reveals its superiority over previous approaches. This allows multimodal image registration with sufficient accuracy of <3 pixels. Conclusion: Our pose estimation pipeline was executed on simulations and patterns; the results demonstrate the robustness of our method and the potential of fiber-optical instrument image-based tracking for pose estimation and multimodal registration. It can be fully implemented in software and therefore easily integrated into a routine clinical environment.
- 2 November 2018
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
- Vol. 7 (5-6) , 667-675
Volumetric monitoring of cutaneous leishmaniasis ulcers: can camera be as accurate as laser scanner?
Cavity volume is an important clinical index for the assessment of the healing process and effectiveness of treatment applied on chronic ulcers. Recently, 3D scanners have proven to effectively track ulcer’s volume evolution. However, photogrammetry presents itself as a low cost and portable alternative. We conducted a comparative study between photogrammetric and 3D scanner-based volume estimation of small skin ulcers. A total of 24 cutaneous leishmaniasis ulcers’ virtual models were generated using a commercial laser scanner and a full-HD portable camera. The reconstruction from videos was performed using open-source software (VisualSFM). The results revealed a similar performance when compared to 3D Scan-based volume estimation with a median deviation and percentile error of 33.68 mm3 and 21.10%, respectively. In addition, the method proved to effectively follow the same tendency in the assessment of healing ulcers when compared to the 3D-scanner. Moreover, when comparing the two virtual models trough residual differences after ICP registration the mean error and standard deviation was 0.36 ± 0.27 mm.
- 2 November 2018
- Published by Taylor & Francis in Computer Methods in Biomechanics and Biomedical Engineering: Imaging & Visualization
- Vol. 7 (5-6) , 667-675
Volumetric monitoring of cutaneous leishmaniasis ulcers: can camera be as accurate as laser scanner?
Cavity volume is an important clinical index for the assessment of the healing process and effectiveness of treatment applied on chronic ulcers. Recently, 3D scanners have proven to effectively track ulcer’s volume evolution. However, photogrammetry presents itself as a low cost and portable alternative. We conducted a comparative study between photogrammetric and 3D scanner-based volume estimation of small skin ulcers. A total of 24 cutaneous leishmaniasis ulcers’ virtual models were generated using a commercial laser scanner and a full-HD portable camera. The reconstruction from videos was performed using open-source software (VisualSFM). The results revealed a similar performance when compared to 3D Scan-based volume estimation with a median deviation and percentile error of 33.68 mm3 and 21.10%, respectively. In addition, the method proved to effectively follow the same tendency in the assessment of healing ulcers when compared to the 3D-scanner. Moreover, when comparing the two virtual models trough residual differences after ICP registration the mean error and standard deviation was 0.36 ± 0.27 mm.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 15224880,p. 5137-5141
Infrared hyperspectral imaging for enhanced tissue visualization and discrimination during surgical operation
A new hyperspectral imaging system has been designed in infrared 950 nm-1700 nm spectral range to be integrated in operating rooms in order to detect some vital and anatomical tissues, hardly noticeable by the surgeon's naked eye during surgical interventions. The main objective of this exploratory study is to find the best three relevant bands to create a RGB image that maximizes the contrast between the target tissue and its surroundings. One of the main challenges in HSI processing is the dimensionality reduction step which was carried out using band transformation and band selection methods in order to remove redundancy in the collected data without losing valuable information. Preclinical experiments were performed in vivo in a porcine ureter. Objective and comparative evaluations, based on the simulated perceived image, were performed between five methods. Experimental results show that the proposed method that combines two band selection methods has the best performance to enhance surgeon's visual skills.
- 1 October 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 15224880,p. 5137-5141
Infrared hyperspectral imaging for enhanced tissue visualization and discrimination during surgical operation
A new hyperspectral imaging system has been designed in infrared 950 nm-1700 nm spectral range to be integrated in operating rooms in order to detect some vital and anatomical tissues, hardly noticeable by the surgeon's naked eye during surgical interventions. The main objective of this exploratory study is to find the best three relevant bands to create a RGB image that maximizes the contrast between the target tissue and its surroundings. One of the main challenges in HSI processing is the dimensionality reduction step which was carried out using band transformation and band selection methods in order to remove redundancy in the collected data without losing valuable information. Preclinical experiments were performed in vivo in a porcine ureter. Objective and comparative evaluations, based on the simulated perceived image, were performed between five methods. Experimental results show that the proposed method that combines two band selection methods has the best performance to enhance surgeon's visual skills.
- Open Access
- 13 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8669, 866923
Colour and multispectral imaging for wound healing evaluation in the context of a comparative preclinical study
Accurate wound assessment is a critical task for patient care and health cost reduction at hospital but even still worse in the context of clinical studies in laboratory. This task, completely devoted to nurses, still relies on manual and tedious practices. Wound shape is measured with rules, tracing papers or rarely with alginate castings and serum injection. The wound tissues proportion is also estimated by a qualitative visual assessment based on the red-yellow-black code. Further to our preceding works on wound 3D complete assessment using a simple freehanded digital camera, we explore here the adaptation of this tool to wounds artificially created for experimentation purposes. It results that tissue uniformity and flatness leads to a simplified approach but requires multispectral imaging for enhanced wound delineation. We demonstrate that, in this context, a simple active contour method can successfully replace more complex tools such as SVM supervised classification, as no training step is required and that one shot is enough to deal with perspective projection errors. Moreover, involving all the spectral response of the tissue and not only RGB components provides a higher discrimination for separating healed epithelial tissue from granulation tissue. This research work is part of a comparative preclinical study on healing wounds. It aims to compare the efficiency of specific medical honeys with classical pharmaceuticals for wound care. Results revealed that medical honey competes with more expensive pharmaceuticals.
- 13 March 2013
- Published by SPIE-Intl Soc Optical Eng
- Vol. 8669, 866923
Open AccessColour and multispectral imaging for wound healing evaluation in the context of a comparative preclinical study
Accurate wound assessment is a critical task for patient care and health cost reduction at hospital but even still worse in the context of clinical studies in laboratory. This task, completely devoted to nurses, still relies on manual and tedious practices. Wound shape is measured with rules, tracing papers or rarely with alginate castings and serum injection. The wound tissues proportion is also estimated by a qualitative visual assessment based on the red-yellow-black code. Further to our preceding works on wound 3D complete assessment using a simple freehanded digital camera, we explore here the adaptation of this tool to wounds artificially created for experimentation purposes. It results that tissue uniformity and flatness leads to a simplified approach but requires multispectral imaging for enhanced wound delineation. We demonstrate that, in this context, a simple active contour method can successfully replace more complex tools such as SVM supervised classification, as no training step is required and that one shot is enough to deal with perspective projection errors. Moreover, involving all the spectral response of the tissue and not only RGB components provides a higher discrimination for separating healed epithelial tissue from granulation tissue. This research work is part of a comparative preclinical study on healing wounds. It aims to compare the efficiency of specific medical honeys with classical pharmaceuticals for wound care. Results revealed that medical honey competes with more expensive pharmaceuticals.
- 1 January 2010
- Published by INSTICC
- p. 60-67
DESIGN OF A CUSTOMIZED PATTERN FOR IMPROVING COLOR CONSTANCY ACROSS CAMERA AND ILLUMINATION CHANGES
- 1 January 2010
- Published by INSTICC
- p. 60-67
DESIGN OF A CUSTOMIZED PATTERN FOR IMPROVING COLOR CONSTANCY ACROSS CAMERA AND ILLUMINATION CHANGES
- 1 April 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Mapping Classification Results on 3D model: a Solution for Measuring the Real Areas Covered by Skin Wound Tissues
We present in this paper part of our work inside the ESCALE project dedicated to the design of a complete 3D and color wound assessment tool using a simple hand held digital camera. The computation of a 3D model for wound measurements using uncalibrated vision techniques has already been investigated in the project. This article presents our methodology to classify wound tissues in the color images, in order to combine shape, deduced from the 3D model, and color analysis in a single tool for real tissue surface measurements. As a first step, we have adopted an original approach based on unsupervised segmentation prior to classification, to improve the robustness of the labelling stage. In the second step, the tissue classification is directly mapped on the mesh surface of the wound to measure real tissue growth and changes. For this purpose, a database of different tissue types has been built and the ground truth of the images is provided by the fusion of several clinician manual labellings. Then, color and texture tissue descriptors are extracted from tissue regions of the images database, for the learning stage of an SVM region classifier relying on expert ground truth. The SVM prediction model has been used to label the segmented regions of the database. Finally, we map the 2D tissue classification on the 3D model. Clinical tests demonstrate that the monitoring of the healing process is very accurate compared to single view analysis.
- 1 April 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Mapping Classification Results on 3D model: a Solution for Measuring the Real Areas Covered by Skin Wound Tissues
We present in this paper part of our work inside the ESCALE project dedicated to the design of a complete 3D and color wound assessment tool using a simple hand held digital camera. The computation of a 3D model for wound measurements using uncalibrated vision techniques has already been investigated in the project. This article presents our methodology to classify wound tissues in the color images, in order to combine shape, deduced from the 3D model, and color analysis in a single tool for real tissue surface measurements. As a first step, we have adopted an original approach based on unsupervised segmentation prior to classification, to improve the robustness of the labelling stage. In the second step, the tissue classification is directly mapped on the mesh surface of the wound to measure real tissue growth and changes. For this purpose, a database of different tissue types has been built and the ground truth of the images is provided by the fusion of several clinician manual labellings. Then, color and texture tissue descriptors are extracted from tissue regions of the images database, for the learning stage of an SVM region classifier relying on expert ground truth. The SVM prediction model has been used to label the segmented regions of the database. Finally, we map the 2D tissue classification on the 3D model. Clinical tests demonstrate that the monitoring of the healing process is very accurate compared to single view analysis.