Sujeong Mun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Sujeong Mun has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Siwoo Lee
Department of Korean Medicine, Gachon University, Incheon, Korea (the Republic of)
7 shared publications - Kihyun Park
KM Data Division, Korea Institute of Oriental Medicine, Daejeon, Republic of Korea
3 shared publications - Younghwa Baek
Division of Korean Medicine Data, Korea Institute of Oriental Medicine, Daejeon 34054, Republic of Korea
3 shared publications - Hoseok Kim
KM Data Division, Korea Institute of Oriental Medicine, Daejeon, Korea (the Republic of)
2 shared publications - Hyun-Chul Jang
KM Data Division, Korea Institute of Oriental Medicine, Daejeon, Republic of Korea
2 shared publications - Icktae Kim
KM Data Division, Korea Institute of Oriental Medicine, Daejeon, Republic of Korea
2 shared publications
Latest Publications
- Open Access
- 1 June 2026
- Published by The Society of Korean Medicine in Journal of Korean Medicine
- Vol. 47 (2) , 108-122
Identification of Cold-Heat Symptom Profiles using Latent Profile Analysis and Their Association with Mental Health
Objectives: Cold-heat pattern identification is a core diagnostic framework in Korean medicine and has been linked to mental health. This study aimed to identify latent subtypes of cold-heat patterns using latent profile analysis (LPA) and to examine their associations with mental health outcomes.Methods: LPA was conducted separately for women and men based on cold-heat symptom responses. Sensitivity analysis using K-means clustering was performed, and agreement between methods was assessed using the adjusted Rand index (ARI). Associations between identified profiles and mental health indicators—including depression-related disorders, Mibyeong (subthreshold) depression, anxiety, anger, and mental component summary (MCS) scores—were evaluated. Heart rate variability (HRV) indices were also analyzed.Results: Four profiles were identified in women (cold-dominant, heat-dominant, mixed sensation, and low-symptom profiles) and three in men (cold-dominant, heat-dominant, and low-symptom profiles). Clustering results showed good agreement between LPA and K-means (ARI=0.74 in women, 0.80 in men). In women, the mixed sensation profile showed higher risks of depression-related disorders, Mibyeong depression, and anxiety. The heat-dominant profile showed elevated risks of Mibyeong depression and anxiety and lower MCS scores, while the cold-dominant profile showed increased Mibyeong anxiety. In men, the heat-dominant profile showed higher risks of Mibyeong anger and anxiety and lower MCS scores. HRV analysis indicated autonomic imbalance in women with mixed sensation and heat-dominant profiles.Conclusions: Data-driven cold-heat pattern subtypes were differentially associated with mental health, supporting the utility of LPA-based classification in understanding their psychological and physiological characteristics.
- 1 June 2026
- Published by The Society of Korean Medicine in Journal of Korean Medicine
- Vol. 47 (2) , 108-122
Open AccessIdentification of Cold-Heat Symptom Profiles using Latent Profile Analysis and Their Association with Mental Health
Objectives: Cold-heat pattern identification is a core diagnostic framework in Korean medicine and has been linked to mental health. This study aimed to identify latent subtypes of cold-heat patterns using latent profile analysis (LPA) and to examine their associations with mental health outcomes.Methods: LPA was conducted separately for women and men based on cold-heat symptom responses. Sensitivity analysis using K-means clustering was performed, and agreement between methods was assessed using the adjusted Rand index (ARI). Associations between identified profiles and mental health indicators—including depression-related disorders, Mibyeong (subthreshold) depression, anxiety, anger, and mental component summary (MCS) scores—were evaluated. Heart rate variability (HRV) indices were also analyzed.Results: Four profiles were identified in women (cold-dominant, heat-dominant, mixed sensation, and low-symptom profiles) and three in men (cold-dominant, heat-dominant, and low-symptom profiles). Clustering results showed good agreement between LPA and K-means (ARI=0.74 in women, 0.80 in men). In women, the mixed sensation profile showed higher risks of depression-related disorders, Mibyeong depression, and anxiety. The heat-dominant profile showed elevated risks of Mibyeong depression and anxiety and lower MCS scores, while the cold-dominant profile showed increased Mibyeong anxiety. In men, the heat-dominant profile showed higher risks of Mibyeong anger and anxiety and lower MCS scores. HRV analysis indicated autonomic imbalance in women with mixed sensation and heat-dominant profiles.Conclusions: Data-driven cold-heat pattern subtypes were differentially associated with mental health, supporting the utility of LPA-based classification in understanding their psychological and physiological characteristics.
- Open Access
- 16 July 2025
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 13, e69328
Detection and Analysis of Circadian Biomarkers for Metabolic Syndrome Using Wearable Data: Cross-Sectional Study
Background: Wearable devices are increasingly used for monitoring health and detecting digital biomarkers related to chronic diseases such as metabolic syndrome (MetS). Although circadian rhythm disturbances are known to contribute to MetS, few studies have explored wearable-derived circadian biomarkers for MetS identification. Objective: This study aimed to detect and analyze sleep and circadian rhythm biomarkers associated with MetS using step count and heart rate data from wearable devices and to identify the key biomarkers using explainable artificial intelligence (XAI). Methods: Data were analyzed from 272 participants in the Korean Medicine Daejeon Citizen Cohort, collected between 2020 and 2023, including 88 participants with MetS and 184 without any MetS diagnostic criteria. Participants wore Fitbit Versa or Inspire 2 devices for at least 5 weekdays, providing minute-level heart rate, step count, and sleep data. A total of 26 indicators were derived, including sleep markers (midsleep time and total sleep time) and circadian rhythm markers (midline estimating statistic of rhythm, amplitude, interdaily stability, and relative amplitude). In addition, a novel circadian rhythm marker, continuous wavelet circadian rhythm energy (CCE), was proposed using continuous wavelet transform of heart rate signals. Statistical tests (t test and the Wilcoxon rank sum test) and machine learning models—Shapley Additive Explanations, explainable boosting machine, and tabular neural network—were applied to evaluate marker significance and importance. Results: Circadian rhythm markers, especially heart rate–based indicators, showed stronger associations with MetS than sleep markers. The newly proposed CCE demonstrated the highest importance for MetS identification across all XAI models, with significantly lower values observed in the MetS group (P<.001). Other heart rate–based markers, including relative amplitude and low activity period, were also identified as important contributors. Although sleep markers did not reach statistical significance, some were recognized as secondary predictors in XAI-based analyses. The CCE marker maintained a high predictive value even when adjusting for age, sex, and BMI. Conclusions: This study identified CCE and relative amplitude of heart rate as key circadian rhythm biomarkers for MetS monitoring, demonstrating their high importance across multiple XAI models. In contrast, traditional sleep markers showed limited significance, suggesting that circadian rhythm analysis may offer additional insights into MetS beyond sleep-related indicators. These findings highlight the potential of wearable-based circadian biomarkers for improving MetS assessment and management.
- 16 July 2025
- Published by JMIR Publications Inc. in JMIR Medical Informatics
- Vol. 13, e69328
Open AccessDetection and Analysis of Circadian Biomarkers for Metabolic Syndrome Using Wearable Data: Cross-Sectional Study
Background: Wearable devices are increasingly used for monitoring health and detecting digital biomarkers related to chronic diseases such as metabolic syndrome (MetS). Although circadian rhythm disturbances are known to contribute to MetS, few studies have explored wearable-derived circadian biomarkers for MetS identification. Objective: This study aimed to detect and analyze sleep and circadian rhythm biomarkers associated with MetS using step count and heart rate data from wearable devices and to identify the key biomarkers using explainable artificial intelligence (XAI). Methods: Data were analyzed from 272 participants in the Korean Medicine Daejeon Citizen Cohort, collected between 2020 and 2023, including 88 participants with MetS and 184 without any MetS diagnostic criteria. Participants wore Fitbit Versa or Inspire 2 devices for at least 5 weekdays, providing minute-level heart rate, step count, and sleep data. A total of 26 indicators were derived, including sleep markers (midsleep time and total sleep time) and circadian rhythm markers (midline estimating statistic of rhythm, amplitude, interdaily stability, and relative amplitude). In addition, a novel circadian rhythm marker, continuous wavelet circadian rhythm energy (CCE), was proposed using continuous wavelet transform of heart rate signals. Statistical tests (t test and the Wilcoxon rank sum test) and machine learning models—Shapley Additive Explanations, explainable boosting machine, and tabular neural network—were applied to evaluate marker significance and importance. Results: Circadian rhythm markers, especially heart rate–based indicators, showed stronger associations with MetS than sleep markers. The newly proposed CCE demonstrated the highest importance for MetS identification across all XAI models, with significantly lower values observed in the MetS group (P<.001). Other heart rate–based markers, including relative amplitude and low activity period, were also identified as important contributors. Although sleep markers did not reach statistical significance, some were recognized as secondary predictors in XAI-based analyses. The CCE marker maintained a high predictive value even when adjusting for age, sex, and BMI. Conclusions: This study identified CCE and relative amplitude of heart rate as key circadian rhythm biomarkers for MetS monitoring, demonstrating their high importance across multiple XAI models. In contrast, traditional sleep markers showed limited significance, suggesting that circadian rhythm analysis may offer additional insights into MetS beyond sleep-related indicators. These findings highlight the potential of wearable-based circadian biomarkers for improving MetS assessment and management.
- Open Access
- 27 November 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Detection and analysis of circadian biomarkers for metabolic syndrome using wearable data and explainable artificial intelligence (Preprint)
BACKGROUND Digital biomarker detection using wearable devices is utilized as a solution for managing metabolic syndrome (MetS) in daily life. OBJECTIVE This study aimed to detect digital biomarkers based on sleep and circadian rhythm using step counts and heart rate data obtained from wearable devices and to analyze important biomarkers for MetS risk groups. METHODS Circadian rhythm markers based on heart rate and step counts were analyzed, including the newly proposed continuous wavelet circadian rhythm energy. The detected markers were analyzed for their contribution to MetS using SHapley Additive exPlanations, Explainable Boosting Machine, and Tabular Neural Network models. RESULTS Analysis of sleep and circadian rhythm biomarkers using statistical analysis and artificial intelligence methods revealed that circadian rhythm markers were more important for MetS than sleep markers. Among circadian rhythm markers, heart rate-based markers were found to be more important than step counts. The continuous wavelet circadian energy proposed in this study showed the highest contribution to MetS in the artificial intelligence analysis results. CONCLUSIONS The risk of MetS can be continuously identified and monitored in daily life by utilizing circadian rhythm markers.
- 27 November 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessDetection and analysis of circadian biomarkers for metabolic syndrome using wearable data and explainable artificial intelligence (Preprint)
BACKGROUND Digital biomarker detection using wearable devices is utilized as a solution for managing metabolic syndrome (MetS) in daily life. OBJECTIVE This study aimed to detect digital biomarkers based on sleep and circadian rhythm using step counts and heart rate data obtained from wearable devices and to analyze important biomarkers for MetS risk groups. METHODS Circadian rhythm markers based on heart rate and step counts were analyzed, including the newly proposed continuous wavelet circadian rhythm energy. The detected markers were analyzed for their contribution to MetS using SHapley Additive exPlanations, Explainable Boosting Machine, and Tabular Neural Network models. RESULTS Analysis of sleep and circadian rhythm biomarkers using statistical analysis and artificial intelligence methods revealed that circadian rhythm markers were more important for MetS than sleep markers. Among circadian rhythm markers, heart rate-based markers were found to be more important than step counts. The continuous wavelet circadian energy proposed in this study showed the highest contribution to MetS in the artificial intelligence analysis results. CONCLUSIONS The risk of MetS can be continuously identified and monitored in daily life by utilizing circadian rhythm markers.
- Open Access
- 1 March 2024
- Published by The Society of Korean Medicine in Journal of Korean Medicine
- Vol. 45 (1) , 125-136
Association of Cold/Heat Sensation with Sleep Quality and Insomnia in Middle-aged Women
Objectives: Cold extremities have been suggested to correlate with sleep disturbances. This study aims to explore the relationship between thermal sensations in body, encompassing both cold and heat sensations, with sleep quality and insomnia.Methods: Self-administered questionnaires were utilized to assess thermal sensations in body, sleep quality and symptoms of insomnia in middle-aged women. A multiple logistic regression analysis was performed to ascertain the association between thermal sensations in body and both sleep quality and insomnia symptoms.Results: Among 899 participants, 255 (28.4%) were categorized in the cold sensation group, 95 (10.6%) in the heat sensation group, 70 (7.8%) in the group with both cold and heat sensations, and 479 (53.3%) in the no-sensation group. Pittsburgh Sleep Quality Index and Insomnia Severity Index were notably higher in the group experiencing both sensations when compared to the no-sensation group. After adjustments for covariates, the odds ratios for poor sleep quality, moderate/severe insomnia, and long sleep latency were significantly elevated in the group with both sensations when compared to the no-sensation group. The odds ratios for poor sleep quality in the cold sensation group and for moderate/severe insomnia and low sleep efficiency in the heat sensation group were significantly higher when compared to the no-sensation group.Conclusions: The risk for sleep disturbances varied depending on the presence of thermal sensations in body, with the greatest risk observed for low sleep quality and insomnia in individuals experiencing both cold and heat sensations.
- 1 March 2024
- Published by The Society of Korean Medicine in Journal of Korean Medicine
- Vol. 45 (1) , 125-136
Open AccessAssociation of Cold/Heat Sensation with Sleep Quality and Insomnia in Middle-aged Women
Objectives: Cold extremities have been suggested to correlate with sleep disturbances. This study aims to explore the relationship between thermal sensations in body, encompassing both cold and heat sensations, with sleep quality and insomnia.Methods: Self-administered questionnaires were utilized to assess thermal sensations in body, sleep quality and symptoms of insomnia in middle-aged women. A multiple logistic regression analysis was performed to ascertain the association between thermal sensations in body and both sleep quality and insomnia symptoms.Results: Among 899 participants, 255 (28.4%) were categorized in the cold sensation group, 95 (10.6%) in the heat sensation group, 70 (7.8%) in the group with both cold and heat sensations, and 479 (53.3%) in the no-sensation group. Pittsburgh Sleep Quality Index and Insomnia Severity Index were notably higher in the group experiencing both sensations when compared to the no-sensation group. After adjustments for covariates, the odds ratios for poor sleep quality, moderate/severe insomnia, and long sleep latency were significantly elevated in the group with both sensations when compared to the no-sensation group. The odds ratios for poor sleep quality in the cold sensation group and for moderate/severe insomnia and low sleep efficiency in the heat sensation group were significantly higher when compared to the no-sensation group.Conclusions: The risk for sleep disturbances varied depending on the presence of thermal sensations in body, with the greatest risk observed for low sleep quality and insomnia in individuals experiencing both cold and heat sensations.
- Open Access
- 21 November 2023
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 11 (1) , e49144
Exploring Variations in Sleep Perception: Comparative Study of Chatbot Sleep Logs and Fitbit Sleep Data
Background: Patient-generated health data are important in the management of several diseases. Although there are limitations, information can be obtained using a wearable device and time-related information such as exercise time or sleep time can also be obtained. Fitbits can be used to acquire sleep onset, sleep offset, total sleep time (TST), and wakefulness after sleep onset (WASO) data, although there are limitations regarding the depth of sleep and satisfaction; therefore, the patient’s subjective response is still important information that cannot be replaced by wearable devices. Objective: To effectively use patient-generated health data related to time such as sleep, it is first necessary to understand the characteristics of the time response recorded by the user. Therefore, the aim of this study was to analyze the characteristics of individuals’ time perception in comparison with wearable data. Methods: Sleep data were acquired for 2 weeks using a Fitbit. Participants’ sleep records were collected daily through chatbot conversations while wearing the Fitbit, and the two sets of data were statistically compared. Results: In total, 736 people aged 30-59 years were recruited for this study, and the sleep data of 543 people who wore a Fitbit and responded to the chatbot for more than 7 days on the same day were analyzed. Research participants tended to respond to sleep-related times on the hour or in 30-minute increments, and each participant responded within the range of 60-90 minutes from the value measured by the Fitbit. On average for all participants, the chat responses and the Fitbit data were similar within a difference of approximately 15 minutes. Regarding sleep onset, the participant response was 8 minutes and 39 seconds (SD 58 minutes) later than that of the Fitbit data, whereas with respect to sleep offset, the response was 5 minutes and 38 seconds (SD 57 minutes) earlier. The participants’ actual sleep time (AST) indicated in the chat was similar to that obtained by subtracting the WASO from the TST measured by the Fitbit. The AST was 13 minutes and 39 seconds (SD 87 minutes) longer than the time WASO was subtracted from the Fitbit TST. On days when the participants reported good sleep, they responded 19 (SD 90) minutes longer on the AST than the Fitbit data. However, for each sleep event, the probability that the participant’s AST was within ±30 and ±60 minutes of the Fitbit TST-WASO was 50.7% and 74.3%, respectively. Conclusions: The chatbot sleep response and Fitbit measured time were similar on average and the study participants had a slight tendency to perceive a relatively long sleep time if the quality of sleep was self-reported as good. However, on a participant-by-participant basis, it was difficult to predict participants’ sleep duration responses with Fitbit data. Individual variations in sleep time perception significantly affect patient responses related to sleep, revealing the limitations of objective measures obtained through wearable devices.
- 21 November 2023
- Published by JMIR Publications Inc. in JMIR mHealth and uHealth
- Vol. 11 (1) , e49144
Open AccessExploring Variations in Sleep Perception: Comparative Study of Chatbot Sleep Logs and Fitbit Sleep Data
Background: Patient-generated health data are important in the management of several diseases. Although there are limitations, information can be obtained using a wearable device and time-related information such as exercise time or sleep time can also be obtained. Fitbits can be used to acquire sleep onset, sleep offset, total sleep time (TST), and wakefulness after sleep onset (WASO) data, although there are limitations regarding the depth of sleep and satisfaction; therefore, the patient’s subjective response is still important information that cannot be replaced by wearable devices. Objective: To effectively use patient-generated health data related to time such as sleep, it is first necessary to understand the characteristics of the time response recorded by the user. Therefore, the aim of this study was to analyze the characteristics of individuals’ time perception in comparison with wearable data. Methods: Sleep data were acquired for 2 weeks using a Fitbit. Participants’ sleep records were collected daily through chatbot conversations while wearing the Fitbit, and the two sets of data were statistically compared. Results: In total, 736 people aged 30-59 years were recruited for this study, and the sleep data of 543 people who wore a Fitbit and responded to the chatbot for more than 7 days on the same day were analyzed. Research participants tended to respond to sleep-related times on the hour or in 30-minute increments, and each participant responded within the range of 60-90 minutes from the value measured by the Fitbit. On average for all participants, the chat responses and the Fitbit data were similar within a difference of approximately 15 minutes. Regarding sleep onset, the participant response was 8 minutes and 39 seconds (SD 58 minutes) later than that of the Fitbit data, whereas with respect to sleep offset, the response was 5 minutes and 38 seconds (SD 57 minutes) earlier. The participants’ actual sleep time (AST) indicated in the chat was similar to that obtained by subtracting the WASO from the TST measured by the Fitbit. The AST was 13 minutes and 39 seconds (SD 87 minutes) longer than the time WASO was subtracted from the Fitbit TST. On days when the participants reported good sleep, they responded 19 (SD 90) minutes longer on the AST than the Fitbit data. However, for each sleep event, the probability that the participant’s AST was within ±30 and ±60 minutes of the Fitbit TST-WASO was 50.7% and 74.3%, respectively. Conclusions: The chatbot sleep response and Fitbit measured time were similar on average and the study participants had a slight tendency to perceive a relatively long sleep time if the quality of sleep was self-reported as good. However, on a participant-by-participant basis, it was difficult to predict participants’ sleep duration responses with Fitbit data. Individual variations in sleep time perception significantly affect patient responses related to sleep, revealing the limitations of objective measures obtained through wearable devices.
- Open Access
- 24 May 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Exploring Variations in Sleep Perception: Comparative Study of Chatbot Sleep Logs and Fitbit Sleep Data (Preprint)
BACKGROUND Patient-generated health data are important in the management of several diseases. Although there are limitations, information can be obtained using a wearable device and time-related information such as exercise time or sleep time can also be obtained. Fitbits can be used to acquire sleep onset, sleep offset, total sleep time (TST), and wakefulness after sleep onset (WASO) data, although there are limitations regarding the depth of sleep and satisfaction; therefore, the patient’s subjective response is still important information that cannot be replaced by wearable devices. OBJECTIVE To effectively use patient-generated health data related to time such as sleep, it is first necessary to understand the characteristics of the time response recorded by the user. Therefore, the aim of this study was to analyze the characteristics of individuals’ time perception in comparison with wearable data. METHODS Sleep data were acquired for 2 weeks using a Fitbit. Participants’ sleep records were collected daily through chatbot conversations while wearing the Fitbit, and the two sets of data were statistically compared. RESULTS In total, 736 people aged 30-59 years were recruited for this study, and the sleep data of 543 people who wore a Fitbit and responded to the chatbot for more than 7 days on the same day were analyzed. Research participants tended to respond to sleep-related times on the hour or in 30-minute increments, and each participant responded within the range of 60-90 minutes from the value measured by the Fitbit. On average for all participants, the chat responses and the Fitbit data were similar within a difference of approximately 15 minutes. Regarding sleep onset, the participant response was 8 minutes and 39 seconds (SD 58 minutes) later than that of the Fitbit data, whereas with respect to sleep offset, the response was 5 minutes and 38 seconds (SD 57 minutes) earlier. The participants’ actual sleep time (AST) indicated in the chat was similar to that obtained by subtracting the WASO from the TST measured by the Fitbit. The AST was 13 minutes and 39 seconds (SD 87 minutes) longer than the time WASO was subtracted from the Fitbit TST. On days when the participants reported good sleep, they responded 19 (SD 90) minutes longer on the AST than the Fitbit data. However, for each sleep event, the probability that the participant’s AST was within ±30 and ±60 minutes of the Fitbit TST-WASO was 50.7% and 74.3%, respectively. CONCLUSIONS The chatbot sleep response and Fitbit measured time were similar on average and the study participants had a slight tendency to perceive a relatively long sleep time if the quality of sleep was self-reported as good. However, on a participant-by-participant basis, it was difficult to predict participants’ sleep duration responses with Fitbit data. Individual variations in sleep time perception significantly affect patient responses related to sleep, revealing the limitations of objective measures obtained through wearable devices.
- 24 May 2023
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessExploring Variations in Sleep Perception: Comparative Study of Chatbot Sleep Logs and Fitbit Sleep Data (Preprint)
BACKGROUND Patient-generated health data are important in the management of several diseases. Although there are limitations, information can be obtained using a wearable device and time-related information such as exercise time or sleep time can also be obtained. Fitbits can be used to acquire sleep onset, sleep offset, total sleep time (TST), and wakefulness after sleep onset (WASO) data, although there are limitations regarding the depth of sleep and satisfaction; therefore, the patient’s subjective response is still important information that cannot be replaced by wearable devices. OBJECTIVE To effectively use patient-generated health data related to time such as sleep, it is first necessary to understand the characteristics of the time response recorded by the user. Therefore, the aim of this study was to analyze the characteristics of individuals’ time perception in comparison with wearable data. METHODS Sleep data were acquired for 2 weeks using a Fitbit. Participants’ sleep records were collected daily through chatbot conversations while wearing the Fitbit, and the two sets of data were statistically compared. RESULTS In total, 736 people aged 30-59 years were recruited for this study, and the sleep data of 543 people who wore a Fitbit and responded to the chatbot for more than 7 days on the same day were analyzed. Research participants tended to respond to sleep-related times on the hour or in 30-minute increments, and each participant responded within the range of 60-90 minutes from the value measured by the Fitbit. On average for all participants, the chat responses and the Fitbit data were similar within a difference of approximately 15 minutes. Regarding sleep onset, the participant response was 8 minutes and 39 seconds (SD 58 minutes) later than that of the Fitbit data, whereas with respect to sleep offset, the response was 5 minutes and 38 seconds (SD 57 minutes) earlier. The participants’ actual sleep time (AST) indicated in the chat was similar to that obtained by subtracting the WASO from the TST measured by the Fitbit. The AST was 13 minutes and 39 seconds (SD 87 minutes) longer than the time WASO was subtracted from the Fitbit TST. On days when the participants reported good sleep, they responded 19 (SD 90) minutes longer on the AST than the Fitbit data. However, for each sleep event, the probability that the participant’s AST was within ±30 and ±60 minutes of the Fitbit TST-WASO was 50.7% and 74.3%, respectively. CONCLUSIONS The chatbot sleep response and Fitbit measured time were similar on average and the study participants had a slight tendency to perceive a relatively long sleep time if the quality of sleep was self-reported as good. However, on a participant-by-participant basis, it was difficult to predict participants’ sleep duration responses with Fitbit data. Individual variations in sleep time perception significantly affect patient responses related to sleep, revealing the limitations of objective measures obtained through wearable devices.
- Open Access
- 18 February 2022
- Published by Springer Nature in EPMA Journal
- Vol. 13 (1) , 125-135
Evaluation of thermal sensitivity is of potential clinical utility for the predictive, preventive, and personalized approach advancing metabolic syndrome management
A possible association between metabolic disorders and ambient temperature has been suggested, and cold exposure as a way of increasing energy expenditure has gained considerable interest for preventative/therapeutic measures toward metabolic disorders. Although thermal sensitivity, which has recently been studied in regard to its utility as a risk assessment/patient stratification for various diseases, might influence physiological responses to ambient temperature on an individual basis, more studies are needed. We aimed to investigate the association between self-identified thermal intolerance/sensation and metabolic syndrome (MetS) to verify the working hypothesis that individuals with altered thermal sensitivity may have a predisposition to MetS. We fitted generalized additive models for thermal intolerance/sensation using body mass index (BMI) and waist–hip ratio in women, and identified those with higher/lower thermal intolerance/sensation than those predicted by the models. Higher heat intolerance, higher heat sensation, and lower cold intolerance were associated with a higher prevalence of MetS. The risk of having MetS was increased in those who had two or three associated conditions compared with those with none of these conditions. In an analysis for MetS components, significant associations of thermal sensitivity were present with high glucose, triglyceride, and blood pressure levels. Overall, higher heat intolerance/sensation and lower cold intolerance were associated with increased prevalence of MetS even at a similar level of obesity. Our study indicates that evaluation of thermal sensitivity may help identify individuals at high risk for MetS, and lead to more advanced patient stratification and personalized treatment strategies for MetS, including cold-induced thermogenesis.
- 18 February 2022
- Published by Springer Nature in EPMA Journal
- Vol. 13 (1) , 125-135
Open AccessEvaluation of thermal sensitivity is of potential clinical utility for the predictive, preventive, and personalized approach advancing metabolic syndrome management
A possible association between metabolic disorders and ambient temperature has been suggested, and cold exposure as a way of increasing energy expenditure has gained considerable interest for preventative/therapeutic measures toward metabolic disorders. Although thermal sensitivity, which has recently been studied in regard to its utility as a risk assessment/patient stratification for various diseases, might influence physiological responses to ambient temperature on an individual basis, more studies are needed. We aimed to investigate the association between self-identified thermal intolerance/sensation and metabolic syndrome (MetS) to verify the working hypothesis that individuals with altered thermal sensitivity may have a predisposition to MetS. We fitted generalized additive models for thermal intolerance/sensation using body mass index (BMI) and waist–hip ratio in women, and identified those with higher/lower thermal intolerance/sensation than those predicted by the models. Higher heat intolerance, higher heat sensation, and lower cold intolerance were associated with a higher prevalence of MetS. The risk of having MetS was increased in those who had two or three associated conditions compared with those with none of these conditions. In an analysis for MetS components, significant associations of thermal sensitivity were present with high glucose, triglyceride, and blood pressure levels. Overall, higher heat intolerance/sensation and lower cold intolerance were associated with increased prevalence of MetS even at a similar level of obesity. Our study indicates that evaluation of thermal sensitivity may help identify individuals at high risk for MetS, and lead to more advanced patient stratification and personalized treatment strategies for MetS, including cold-induced thermogenesis.
- Open Access
- 1 December 2021
- Published by The Society of Korean Medicine in Journal of Korean Medicine
- Vol. 42 (4) , 185-196
Study on the Anthropometric and Body Composition Indices for Prediction of Cold and Heat Patter
Objectives: Many symptoms of cold and heat patterns are related to the thermoregulation of the body. Thus, we aimed to study the association of cold and heat patterns with anthropometry/body composition.Methods: The cold and heat patterns of 2000 individuals aged 30–55 years were evaluated using a self-administered questionnaire.Results: Among the anthropometric and body composition variables, body mass index (-0.37, 0.39) and fat mass index (-0.35, 0.38) had the highest correlation coefficients with the cold and heat pattern scores after adjustment for age and sex in the cold-heat group, while the correlation coefficients were relatively lower in the non-cold-heat group. In the cold-heat group, the most parsimonious model for the cold pattern with the variables selected by the best subset method and Lasso included sex, body mass index, waist-hip ratio, and extracellular water/total body water (adjusted R2 = 0.324), and the model for heat pattern additionally included age (adjusted R2 = 0.292).Conclusions: The variables related to obesity and water balance were the most useful for predicting cold and heat patterns. Further studies are required to improve the performance of prediction models.
- 1 December 2021
- Published by The Society of Korean Medicine in Journal of Korean Medicine
- Vol. 42 (4) , 185-196
Open AccessStudy on the Anthropometric and Body Composition Indices for Prediction of Cold and Heat Patter
Objectives: Many symptoms of cold and heat patterns are related to the thermoregulation of the body. Thus, we aimed to study the association of cold and heat patterns with anthropometry/body composition.Methods: The cold and heat patterns of 2000 individuals aged 30–55 years were evaluated using a self-administered questionnaire.Results: Among the anthropometric and body composition variables, body mass index (-0.37, 0.39) and fat mass index (-0.35, 0.38) had the highest correlation coefficients with the cold and heat pattern scores after adjustment for age and sex in the cold-heat group, while the correlation coefficients were relatively lower in the non-cold-heat group. In the cold-heat group, the most parsimonious model for the cold pattern with the variables selected by the best subset method and Lasso included sex, body mass index, waist-hip ratio, and extracellular water/total body water (adjusted R2 = 0.324), and the model for heat pattern additionally included age (adjusted R2 = 0.292).Conclusions: The variables related to obesity and water balance were the most useful for predicting cold and heat patterns. Further studies are required to improve the performance of prediction models.