JSJiri Smetana

Jiri Smetana

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jiri Smetana has a total of 57 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Extending ground-based gravitational-wave sensitivity to 5 Hz

    by Amit Singh Ubhi, Lari Koponen, Jiri Smetana, Yulin Xia, Haixing Miao, Emilia Chick, John Bryant, Geraint Pratten, Teng Zhang, Richard Mittleman, et al.

    Extending the sensitivity of terrestrial gravitational-wave detectors below 20 Hz is a long-standing challenge, limited by ground motion and inertial sensing noise. In this Letter, we demonstrate ultra-high-vacuum compatible inertial isolation and position sensing technologies that achieve active platform stabilization down to 10 mHz. Our laser position sensors reach a sub − pm / Hz sensitivity above 10 mHz, independent of the input light polarization, representing a 100-fold improvement over the current LIGO position sensors. In addition, our inertial sensors provide at least a factor of 5 improvement in low-frequency sensitivity compared to state-of-the-art commercial seismometers. We integrate these technologies into a LIGO-like interferometer model and predict a low-frequency sensitivity improvement of up to an order of magnitude at 10 Hz, with enhanced linearity and calibration stability. This extension increases the detection horizon for intermediate-mass black hole binaries of mass 10 3 M ⊙ by a factor of 3 and increases the SNR for all lower mass binaries. Our results provide the first experimental demonstration of a practical pathway to sub-10 Hz operation of terrestrial gravitational-wave detectors and establish key technologies for next-generation observatories such as Cosmic Explorer and Einstein Telescope.

  • Open Access

    First result for testing semiclassical gravity effect with a torsion balance

    by Tianliang Yan, Leonid Prokhorov, Jiri Smetana, Vincent Boyer, Denis Martynov, Yubao Liu, Yiqiu Ma, Haixing Miao

    The Schrödinger-Newton equation, a theoretical framework connecting quantum mechanics with classical gravity, predicts that gravity may induce measurable deviations in low-frequency mechanical systems—an intriguing hypothesis at the frontier of fundamental physics. In this study, we developed and operated an advanced optomechanical platform to investigate these effects. The system integrates an optical cavity with finesse over 3.5 × 10 5 and a torsion pendulum with an ultralow eigenfrequency of 0.6 mHz, achieving a high mechanical quality factor exceeding 5 × 10 4 . We collected data for three months and reached a sensitivity of 0.3 μ rad / Hz at the Schrödinger-Newton frequency of 2.5 mHz where deviations from the standard quantum mechanics may occur. While no evidence supporting semiclassical gravity was found, we identify key challenges in such tests and propose new experimental approaches to advance this line of inquiry. This work demonstrates the potential of precision optomechanics to probe the interplay between quantum mechanics and gravity.


  • Open Access

    Sensitivity and control of a six-axis fused-silica seismometer

    by Jiri Smetana, Amit Singh Ubhi, Emilia Chick, Leonid Prokhorov, John Bryant, Artemiy Dmitriev, Alex Gill, Lari Koponen, Denis Martynov, Haixing Miao, et al.

    We present a pair of seismometers capable of measurement in all six axes of rigid motion. The vacuum-compatible devices implement compact interferometric displacement sensors to surpass the sensitivity of typical electrical-readout schemes. Together with the capability to subtract the sensitivity-limiting coupling of ground tilt into horizontal motion, our seismometers can widen the sensing band toward megahertz frequencies. This has notable applications across a range of fields requiring access to low-frequency signals, such as seismology and climate research. We particularly highlight their potential application in gravitational-wave observatories (the Laser Interferometer Gravitational-Wave Observatory, LIGO) in improving their observation capability of intermediate-mass black holes (approximately 1000 M ⊙ ). The sensors are based on a near-monolithic fused-silica design consisting of a fused-silica mass and fiber, showing improved stability and robustness to tilt drifts, alignment, and control compared to all-metal or mixed metal-silica designs. We demonstrate tilt sensitivity that surpasses the best commercial alternatives in a significantly reduced footprint compared to our previous iterations of these sensors.


  • Open Access

    First Results of the Laser-Interferometric Detector for Axions (LIDA)

    by Joscha Heinze, Alex Gill, Artemiy Dmitriev, Jiří Smetana, Tianliang Yan, Vincent Boyer, Denis Martynov, Matthew Evans

    We present the operating principle and the first observing run of a novel kind of direct detector for axions and axionlike particles in the galactic halo. Sensitive to the polarisation rotation of linearly polarised laser light induced by an axion field, our experiment is the first detector of its kind collecting scientific data. We discuss our peak sensitivity of 1.51×10−10  GeV−1 (95% confidence level) to the axion-photon coupling strength in the axion mass range of 1.97–2.01 neV which is, for instance, motivated by supersymmetric grand-unified theories. We also report on effects that arise in our high-finesse in-vacuum cavity at an unprecedented optical continuous-wave intensity of 4.7  MW/cm2. Our detector already belongs to the most sensitive direct searches within its measurement band, and our results pave the way towards surpassing the current sensitivity limits even of astrophysical observations in the mass range from 10−8 down to 10−16  eV via quantum-enhanced laser interferometry, especially with the potential of scaling our detector up to kilometer length.


  • Open Access

    DarkGEO: a large-scale laser-interferometric axion detector

    by Joscha Heinze, Alex Gill, Artemiy Dmitriev, Jiří Smetana, Tianliang Yan, Vincent Boyer, Denis Martynov, Hartmut Grote, James Lough, Aldo Ejlli, et al.

    Axions and axion-like particles (ALPs) are leading candidates for dark matter. They are well motivated in many extensions of the standard model and supported by astronomical observations. We propose an iterative transformation of the existing facilities of the gravitational-wave detector and technology testbed GEO600, located near Ruthe in Germany, into a kilometre-scale upgrade of the laser-interferometric axion detector LIDA. The final DarkGEO detector could search for coincident signatures of axions and ALPs and significantly surpass the current constraints of both direct searches and astrophysical observations in the measurement band from 10−16 to 10−8eV. We discuss design parameters and sensitivities for the configurations of the different iteration steps as well as technical challenges known from the first LIDA results. The proposed DarkGEO detector will be well suited to probe the mass-coupling parameter space associated with predictions from theoretical models, like grand-unified theories, as well as from astrophysical evidence, like the cosmic infrared background.


  • Open Access

    A High-Finesse Suspended Interferometric Sensor for Macroscopic Quantum Mechanics with Femtometre Sensitivity

    by Jiri Smetana, Tianliang Yan, Vincent Boyer, Denis Martynov

    We present an interferometric sensor for investigating macroscopic quantum mechanics on a table-top scale. The sensor consists of pair of suspended optical cavities with a finesse in excess of 100,000 comprising 10 g fused-silica mirrors. In the current room-temperature operation, we achieve a peak sensitivity of \SI{0.5}{\fmasd} in the acoustic frequency band, limited by the readout noise. With additional suppression of the readout noise, we will be able to reach the quantum radiation pressure noise, which would represent a novel measurement of the quantum back-action effect. Such a sensor can eventually be utilised for demonstrating macroscopic entanglement and testing semi-classical and quantum gravity models.

  • Open Access

    A High-Finesse Suspended Interferometric Sensor for Macroscopic Quantum Mechanics with Femtometre Sensitivity

    by Jiri Smetana, Tianliang Yan, Vincent Boyer, Denis Martynov

    We present an interferometric sensor for investigating macroscopic quantum mechanics on a table-top scale. The sensor consists of a pair of suspended optical cavities with finesse over 350,000 comprising 10 g fused silica mirrors. The interferometer is suspended by a four-stage, light, in-vacuum suspension with three common stages, which allows for us to suppress common-mode motion at low frequency. The seismic noise is further suppressed by an active isolation scheme, which reduces the input motion to the suspension point by up to an order of magnitude starting from 0.7 Hz. In the current room-temperature operation, we achieve a peak sensitivity of 0.5 fm/Hz in the acoustic frequency band, limited by a combination of readout noise and suspension thermal noise. Additional improvements of the readout electronics and suspension parameters will enable us to reach the quantum radiation pressure noise. Such a sensor can eventually be utilized for demonstrating macroscopic entanglement and for testing semi-classical and quantum gravity models.


  • Open Access

    Design and sensitivity of a 6-axis seismometer for gravitational wave observatories

    by Leonid Prokhorov, Sam Cooper, Amit Singh Ubhi, Conor Mow-Lowry, John Bryant, Artemiy Dmitriev, Chiara Di Fronzo, Christopher J. Collins, Alex Gill, Alexandra Mitchell, et al.

    We present the design, control system, and noise analysis of a 6-axis seismometer comprising a mass suspended by a single fused silica fiber. We utilize custom-made, compact Michelson interferometers for the readout of the mass motion relative to the table and successfully overcome the sensitivity of existing commercial seismometers by over an order of magnitude in the angular degrees of freedom. We develop the sensor for gravitational-wave observatories, such as LIGO, Virgo, and KAGRA, to help them observe intermediate-mass black holes, increase their duty cycle, and improve localization of sources. Our control system and its achieved sensitivity makes the sensor suitable for other fundamental physics experiments, such as tests of semiclassical gravity, searches for bosonic dark matter, and studies of the Casimir force. Published by the American Physical Society 2024


  • Open Access

    Nonlinearities in Fringe-Counting Compact Michelson Interferometers

    by Jiri Smetana, Chiara Di Fronzo, Anthony Amorosi, Denis Martynov

    Compact Michelson interferometers are well positioned to replace existing displacement sensors in the readout of seismometers and suspension systems, such as those used in contemporary gravitational-wave detectors. Here, we continue our previous investigation of a customised compact displacement sensor built by SmarAct that operates on the principle of deep frequency modulation. The focus of this paper is the linearity of this device and its subsequent impact on sensitivity. We show the three primary sources of nonlinearity that arise in the sensor: residual ellipticity, intrinsic distortion of the Lissajous figure, and distortion caused by exceeding the velocity limit imposed by the demodulation algorithm. We verify the theoretical models through an experimental demonstration, where we show the detrimental impact that these nonlinear effects have on device sensitivity. Finally, we simulate the effect that these nonlinearities are likely to have if implemented in the readout of the Advanced LIGO suspensions and show that the noise from nonlinearities should not dominate across the key sub-10 Hz frequency band.


  • Open Access

    Nonlinearities in Long-Range Compact Michelson Interferometers

    by Jiri Smetana, Chiara Di Fronzo, Anthony Amorosi, Denis Martynov

    Compact Michelson interferometers are well positioned to replace existing displacement sensors in the readout of seismometers and suspension systems, such as those used in contemporary gravitational-wave detectors. Here, we continue our previous investigation of a customised compact displacement sensor built by SmarAct, which operated on the principle of deep frequency modulation. The focus of this paper is on the linearity of this device. We show the three primary sources of nonlinearity that arise in the sensor -- residual ellipticity, intrinsic distortion of the Lissajous figure, and distortion caused by exceeding the velocity limit imposed by the demodulation algorithm. We verify the theoretical models through an experimental demonstration designed to maximise the nonlinear noise to dominate regions of the readout's power spectrum. We finally simulate the effect that these nonlinearities are likely to have if implemented in the readout of the Advanced LIGO suspensions and show that the noise nonlinearities should not dominate across the key sub-\SI{10}{\Hz} frequency band.