Spencer Jason Montgomery
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Spencer Jason Montgomery has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Amir Khoshbin
Division of Orthopaedic Surgery, Department of Surgery, University of Toronto, Toronto, Ontario, Canada
1 shared publication Amit Atrey
Division of Orthopaedic Surgery, University of Toronto, Toronto, Canada
1 shared publication- Daniel Z. You
Department of Orthopedic Surgery, Mayo Clinic, Rochester, MN, USA
1 shared publication Drew P. Melancon
University of Mississippi Medical Center, Jackson, USA
1 shared publicationEvan H. Powers
University of Mississippi Medical Center, Jackson, USA
1 shared publicationIsaac J. Spears
University of Mississippi Medical Center, Jackson, USA
1 shared publication
Latest Publications
- Open Access
- 17 February 2025
- Published by Springer Nature in Knee Surgery & Related Research
- Vol. 37 (1) , 1-10
Caliper verification and gap measurements of kinematic alignment total knee arthroplasty utilizing an imageless, accelerometer-based navigation system
Purpose: Kinematic alignment (KA) in total knee arthroplasty (TKA) aims to restore the patient’s knee to the prearthritic state. The purpose of this study was to investigate the accuracy of using an implant-agnostic, imageless, accelerometer-based navigation system to perform KA TKA on the basis of caliper verification and quantification of the flexion and extension gaps. Materials and methods: Seven cadaveric lower extremities underwent primary TKA utilizing a kinematic alignment workflow with the imageless navigation system. Accuracy of the technique was confirmed through caliper verification of bone cuts. Results: All cuts were within 1 mm of anticipated measurements, except for the lateral tibial fragment, which averaged 1 mm (standard deviation [SD] 0.9 mm) thicker than anticipated. In extension, medial and lateral gaps were symmetric and averaged within 0.6 mm of expectation. In flexion, the medial gap averaged within 0.5 mm of expectation, while the lateral gap averaged 2.6 mm larger than the symmetric expectation, consistently producing a trapezoidal space. Conclusions: The implementation of an accelerometer-based navigation system in KA TKA allows for highly accurate results, which was confirmed with caliper verification. This workflow produced a symmetric extension gap and a trapezoidal flexion gap with an average increased lateral flexion gap of 2.6 mm compared with the medial side.
- 17 February 2025
- Published by Springer Nature in Knee Surgery & Related Research
- Vol. 37 (1) , 1-10
Open AccessCaliper verification and gap measurements of kinematic alignment total knee arthroplasty utilizing an imageless, accelerometer-based navigation system
Purpose: Kinematic alignment (KA) in total knee arthroplasty (TKA) aims to restore the patient’s knee to the prearthritic state. The purpose of this study was to investigate the accuracy of using an implant-agnostic, imageless, accelerometer-based navigation system to perform KA TKA on the basis of caliper verification and quantification of the flexion and extension gaps. Materials and methods: Seven cadaveric lower extremities underwent primary TKA utilizing a kinematic alignment workflow with the imageless navigation system. Accuracy of the technique was confirmed through caliper verification of bone cuts. Results: All cuts were within 1 mm of anticipated measurements, except for the lateral tibial fragment, which averaged 1 mm (standard deviation [SD] 0.9 mm) thicker than anticipated. In extension, medial and lateral gaps were symmetric and averaged within 0.6 mm of expectation. In flexion, the medial gap averaged within 0.5 mm of expectation, while the lateral gap averaged 2.6 mm larger than the symmetric expectation, consistently producing a trapezoidal space. Conclusions: The implementation of an accelerometer-based navigation system in KA TKA allows for highly accurate results, which was confirmed with caliper verification. This workflow produced a symmetric extension gap and a trapezoidal flexion gap with an average increased lateral flexion gap of 2.6 mm compared with the medial side.
- 1 January 2022
- Published by Springer Nature
- p. 419-438
International Registries – A Comparison of Outcomes
- 1 January 2022
- Published by Springer Nature
- p. 419-438
International Registries – A Comparison of Outcomes
- 1 December 2021
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 103-B (12) , 1783-1790
Cost-effectiveness of dual-mobility components in patients with displaced femoral neck fractures
The British Editorial Society of Bone & Joint Surgery
- 1 December 2021
- Published by British Editorial Society of Bone & Joint Surgery in The Bone & Joint Journal
- Vol. 103-B (12) , 1783-1790
Cost-effectiveness of dual-mobility components in patients with displaced femoral neck fractures
The British Editorial Society of Bone & Joint Surgery
- 1 March 2020
- Published by Elsevier in Journal of Surgical Education
- Vol. 77 (2) , 472-478
Impact of 3D Printed Calcaneal Models on Fracture Understanding and Confidence in Orthopedic Surgery Residents
- 1 March 2020
- Published by Elsevier in Journal of Surgical Education
- Vol. 77 (2) , 472-478
Impact of 3D Printed Calcaneal Models on Fracture Understanding and Confidence in Orthopedic Surgery Residents