Zhencheng Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhencheng Chen has a total of 22 co-authors. Here are the top co-authors by number of shared publications:
- Guo-Cheng Han
School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, China
10 shared publications - Heinz-Bernhard Kraatz
Department of Chemistry, University of Toronto, 80 St. George Street, M5S 3H6, Toronto, Canada
9 shared publications Xiao-Zhen Feng
School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, 541004, PR China
9 shared publicationsTao Zhan
School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin 541004, PR China
4 shared publicationsYun-Yun Cheng
School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, 541004, PR China
4 shared publications- Tao Zhan
School of Life and Environmental Sciences, Guilin University of Electronic Technology, Guilin, China
3 shared publications
Latest Publications
- 24 July 2023
- Published by Elsevier in Food Chemistry
- Vol. 429, 136997
Electrochemical sensor for ultrasensitive sensing of biotin based on heme conjugated with gold nanoparticles and its electrooxidation mechanism
- 24 July 2023
- Published by Elsevier in Food Chemistry
- Vol. 429, 136997
Electrochemical sensor for ultrasensitive sensing of biotin based on heme conjugated with gold nanoparticles and its electrooxidation mechanism
- 1 January 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (1) , 017509
Synergistic Amplification Signal Based on CoNPs and Melamine for Simultaneous Quantification of Epinephrine and Serotonin
Here we report an electrochemical sensor for the detection of epinephrine (EP) and serotonin (5-HT), two important neurotransmitters in the mammalian central nervous system, which are also present in serum. Their concentration will affect the psychological and physiological activities of the human body, especially in regulating emotions. Therefore, it is very important to detect EP and 5-HT simultaneously. Herein, cobalt nanoparticles (CoNPs) and melamine (MEL) were deposited on a glassy carbon electrode (GCE) by cyclic voltammetry (CV), resulting in an electrochemical sensor (MEL/CoNPs/GCE) that allowed the detection of both EP (0.23 V) and 5-HT (0.38 V vs. Ag/AgCl). Square wave voltammetry (SWV) measurements allowed us to establish a linear range of EP and 5-HT in the range of 5.00 to 500.00 μ mol·l −1 , with a limit of detection of 1.60 μ mol·l −1 for EP, and of 2.52 μ mol·l −1 for 5-HT. The detection sensitivity were 1.38 and 1.62 μ A· μ M −1 ·cm −2 for EP and 5-HT. Finally, the sensor also was used to detect serum with a recovery of 92.8% to 98.2% for EP, 98.7% to 99.0% for 5-HT, with RSD of 3.3%, indicated that it can be used for the rapid and simultaneous detection of EP and 5-HT.
- 1 January 2023
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 170 (1) , 017509
Synergistic Amplification Signal Based on CoNPs and Melamine for Simultaneous Quantification of Epinephrine and Serotonin
Here we report an electrochemical sensor for the detection of epinephrine (EP) and serotonin (5-HT), two important neurotransmitters in the mammalian central nervous system, which are also present in serum. Their concentration will affect the psychological and physiological activities of the human body, especially in regulating emotions. Therefore, it is very important to detect EP and 5-HT simultaneously. Herein, cobalt nanoparticles (CoNPs) and melamine (MEL) were deposited on a glassy carbon electrode (GCE) by cyclic voltammetry (CV), resulting in an electrochemical sensor (MEL/CoNPs/GCE) that allowed the detection of both EP (0.23 V) and 5-HT (0.38 V vs. Ag/AgCl). Square wave voltammetry (SWV) measurements allowed us to establish a linear range of EP and 5-HT in the range of 5.00 to 500.00 μ mol·l −1 , with a limit of detection of 1.60 μ mol·l −1 for EP, and of 2.52 μ mol·l −1 for 5-HT. The detection sensitivity were 1.38 and 1.62 μ A· μ M −1 ·cm −2 for EP and 5-HT. Finally, the sensor also was used to detect serum with a recovery of 92.8% to 98.2% for EP, 98.7% to 99.0% for 5-HT, with RSD of 3.3%, indicated that it can be used for the rapid and simultaneous detection of EP and 5-HT.
- 5 August 2022
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 414 (23) , 6791-6800
Facile bimetallic co-amplified electrochemical sensor for folic acid sensing based on CoNPs and CuNPs
Folic acid (FA) is essential for human health, particularly for pregnant women and infants. In this work, a glassy carbon electrode (GCE) was modified by a bimetallic layer of Cu/Co nanoparticles (CuNPs/CoNPs) as a synergistic amplification element by simple step-by-step electrodeposition, and was used for sensitive detection of FA. The proposed CuNPs/CoNPs/GCE sensor was characterized by differential pulse voltammetry (DPV), electrochemical impedance spectroscopy (EIS) and field emission scanning electron microscopy (FESEM). Then, under optimal conditions, a linear relationship was obtained in the wide range of 110.00–1750.00 μM for the detection of FA with a limit of detection (LOD) of 34.79 μM (S/N = 3). The sensitivity was calculated as 0.096 μA μM−1 cm−2. Some interfering compounds including glucose (Glc), biotin, dopamine (DA), and glutamic acid (Glu) showed little effect on the detection of FA by amperometry (i-t). Finally, the average recovery obtained was in a range of 91.77–110.06%, with a relative standard deviation (RSD) less than 8.00% in FA tablets, indicating that the proposed sensor can accurately and effectively detect the FA content in FA tablets.
- 5 August 2022
- Published by Springer Nature in Analytical and Bioanalytical Chemistry
- Vol. 414 (23) , 6791-6800
Facile bimetallic co-amplified electrochemical sensor for folic acid sensing based on CoNPs and CuNPs
Folic acid (FA) is essential for human health, particularly for pregnant women and infants. In this work, a glassy carbon electrode (GCE) was modified by a bimetallic layer of Cu/Co nanoparticles (CuNPs/CoNPs) as a synergistic amplification element by simple step-by-step electrodeposition, and was used for sensitive detection of FA. The proposed CuNPs/CoNPs/GCE sensor was characterized by differential pulse voltammetry (DPV), electrochemical impedance spectroscopy (EIS) and field emission scanning electron microscopy (FESEM). Then, under optimal conditions, a linear relationship was obtained in the wide range of 110.00–1750.00 μM for the detection of FA with a limit of detection (LOD) of 34.79 μM (S/N = 3). The sensitivity was calculated as 0.096 μA μM−1 cm−2. Some interfering compounds including glucose (Glc), biotin, dopamine (DA), and glutamic acid (Glu) showed little effect on the detection of FA by amperometry (i-t). Finally, the average recovery obtained was in a range of 91.77–110.06%, with a relative standard deviation (RSD) less than 8.00% in FA tablets, indicating that the proposed sensor can accurately and effectively detect the FA content in FA tablets.
- 1 August 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (8) , 087516
A Novel Electrochemical Strategy for Chloramphenicol Detection in a Water Environment Based on Silver Nanoparticles and Thiophene
As a synthetic broad-spectrum antibiotic, chloramphenicol (CAP) is widely used in the prevention and treatment of bacterial diseases in aquaculture and animal husbandry, which might lead to severe water contamination and thus threaten our health. Herein, a novel electrochemical strategy for CAP detection is proposed that the sensor was successfully constructed based on the hardly mentioned anodic peak (about −0.56 V) by modifying silver nanoparticles (AgNPs) and thiophene (TP) on a glassy carbon electrode (GCE) as synergistic amplification unit with a simple step-by-step electrodeposition technique. Electrochemical methods, scanning electron microscopy (SEM) and X-ray energy dispersive spectroscopy (EDS) were applied to characterize the as-prepared sensor. The TP/AgNPs/GCE sensor was used for CAP detection by DPV in the concentration range of 100.0 − 1600.0 μ M, the limit of detection (LOD) was 33.0 μ M, and the sensitivity was 0.290 μ A· μ M −1 ·cm −2 . In addition, the sensor has the advantages of simple preparation, low cost, good repeatability, stability and anti-interference. It has been used for the detection of CAP in lake water with a recovery of 101.80–104.85%, and the relative standard deviation (RSD) was lower than 1.22%, which confirms that the sensor has good practicability.
- 1 August 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (8) , 087516
A Novel Electrochemical Strategy for Chloramphenicol Detection in a Water Environment Based on Silver Nanoparticles and Thiophene
As a synthetic broad-spectrum antibiotic, chloramphenicol (CAP) is widely used in the prevention and treatment of bacterial diseases in aquaculture and animal husbandry, which might lead to severe water contamination and thus threaten our health. Herein, a novel electrochemical strategy for CAP detection is proposed that the sensor was successfully constructed based on the hardly mentioned anodic peak (about −0.56 V) by modifying silver nanoparticles (AgNPs) and thiophene (TP) on a glassy carbon electrode (GCE) as synergistic amplification unit with a simple step-by-step electrodeposition technique. Electrochemical methods, scanning electron microscopy (SEM) and X-ray energy dispersive spectroscopy (EDS) were applied to characterize the as-prepared sensor. The TP/AgNPs/GCE sensor was used for CAP detection by DPV in the concentration range of 100.0 − 1600.0 μ M, the limit of detection (LOD) was 33.0 μ M, and the sensitivity was 0.290 μ A· μ M −1 ·cm −2 . In addition, the sensor has the advantages of simple preparation, low cost, good repeatability, stability and anti-interference. It has been used for the detection of CAP in lake water with a recovery of 101.80–104.85%, and the relative standard deviation (RSD) was lower than 1.22%, which confirms that the sensor has good practicability.
- 1 July 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (7) , 077510
Synergistic Electrochemical Amplification of Ferrocene Carboxylic Acid Nanoflowers and Cu Nanoparticles for Folic Acid Sensing
Folic acid (FA) plays an indispensable role in human body and sometimes needs to be taken as a drug supplement, especially for pregnant women. Herein, an electrochemical FA sensor was constructed by electrodepositing Cu and ferrocene carboxylic acid (Fc(COOH)) on a glassy carbon electrode (GCE), indicating low cost, simple preparation and short time consumption. Furthermore, the field emission scanning electron microscopy illustrates that Fc(COOH) completely covering Cu nanoparticles (CuNPs) grew to be tufts of loose and porous nanoflowers in situ, which produces a large active surface area to adsorb FA. Results verify that two conjected materials exhibited a good synergistic amplification effect on FA signal. Ultimately, a great linear relationship of FA was established between 100.0 ∼ 1000.0 μ M under optimized conditions by differential pulse voltammetry (DPV). The limit of detection was 33.3 μ M, and the sensitivity was 0.10149 μ A· μ M −1 ·cm −2 . The sensor Fc(COOH)/CuNPs/GCE showed satisfactory selectivity and stability and could be used for FA detection in FA tablets samples with an average recovery of 91.43 ∼ 100.68%, and a relative standard deviation less than 3.17%. The consistency and validity were affirmed by comparisons with an ultra-visible spectrophotometer.
- 1 July 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (7) , 077510
Synergistic Electrochemical Amplification of Ferrocene Carboxylic Acid Nanoflowers and Cu Nanoparticles for Folic Acid Sensing
Folic acid (FA) plays an indispensable role in human body and sometimes needs to be taken as a drug supplement, especially for pregnant women. Herein, an electrochemical FA sensor was constructed by electrodepositing Cu and ferrocene carboxylic acid (Fc(COOH)) on a glassy carbon electrode (GCE), indicating low cost, simple preparation and short time consumption. Furthermore, the field emission scanning electron microscopy illustrates that Fc(COOH) completely covering Cu nanoparticles (CuNPs) grew to be tufts of loose and porous nanoflowers in situ, which produces a large active surface area to adsorb FA. Results verify that two conjected materials exhibited a good synergistic amplification effect on FA signal. Ultimately, a great linear relationship of FA was established between 100.0 ∼ 1000.0 μ M under optimized conditions by differential pulse voltammetry (DPV). The limit of detection was 33.3 μ M, and the sensitivity was 0.10149 μ A· μ M −1 ·cm −2 . The sensor Fc(COOH)/CuNPs/GCE showed satisfactory selectivity and stability and could be used for FA detection in FA tablets samples with an average recovery of 91.43 ∼ 100.68%, and a relative standard deviation less than 3.17%. The consistency and validity were affirmed by comparisons with an ultra-visible spectrophotometer.
- Open Access
- 10 February 2022
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 12 (9) , 5072-5079
Enzyme-free glucose sensors with efficient synergistic electro-catalysis based on a ferrocene derivative and two metal nanoparticles
Gold electrodes (GE) were modified by the deposition of copper nanoparticles (CuNPs) and cobalt nanoparticles (CoNPs), followed by drop-casting of the ferrocene derivative FcCO-Glu-Cys-Gly-OH (Fc-ECG), resulting in two enzyme-free electrochemical sensors Fc-ECG/CuNPs/GE and Fc-ECG/CuNPs/GE. The ferrocene-peptide conjugate acts as an effective redox mediator for glucose oxidation, while metal nanoparticles acted as non-biological sites for glucose oxidation. Field emission scanning electron microscopy (FESEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were carried out for characterization, while differential pulse voltammetry (DPV) was used for glucose quantification. Under optimized conditions, DPV shows a linear relationship between glucose concentration and the peak current. Both sensors showed a surprisingly high sensitivity of 217.27 and 378.70 μA mM−1 cm−2, respectively. A comparison to other glucose sensors shows a sensitivity that is 25 times higher. The sensors exhibit good reproducibility, stability, and repeatability. In injection experiments, recovery rates were 87.39–107.65% and 100.00–106.88%, respectively.
- 10 February 2022
- Published by Royal Society of Chemistry (RSC) in RSC Advances
- Vol. 12 (9) , 5072-5079
Open AccessEnzyme-free glucose sensors with efficient synergistic electro-catalysis based on a ferrocene derivative and two metal nanoparticles
Gold electrodes (GE) were modified by the deposition of copper nanoparticles (CuNPs) and cobalt nanoparticles (CoNPs), followed by drop-casting of the ferrocene derivative FcCO-Glu-Cys-Gly-OH (Fc-ECG), resulting in two enzyme-free electrochemical sensors Fc-ECG/CuNPs/GE and Fc-ECG/CuNPs/GE. The ferrocene-peptide conjugate acts as an effective redox mediator for glucose oxidation, while metal nanoparticles acted as non-biological sites for glucose oxidation. Field emission scanning electron microscopy (FESEM), cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) were carried out for characterization, while differential pulse voltammetry (DPV) was used for glucose quantification. Under optimized conditions, DPV shows a linear relationship between glucose concentration and the peak current. Both sensors showed a surprisingly high sensitivity of 217.27 and 378.70 μA mM−1 cm−2, respectively. A comparison to other glucose sensors shows a sensitivity that is 25 times higher. The sensors exhibit good reproducibility, stability, and repeatability. In injection experiments, recovery rates were 87.39–107.65% and 100.00–106.88%, respectively.
- 9 February 2022
- Published by Elsevier in Food Chemistry
- Vol. 383, 132403
One step construction of an electrochemical sensor for melamine detection in milk towards an integrated portable system
- 9 February 2022
- Published by Elsevier in Food Chemistry
- Vol. 383, 132403
One step construction of an electrochemical sensor for melamine detection in milk towards an integrated portable system
- Open Access
- 7 December 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (12) , 1519
Convenient Heme Nanorod Modified Electrode for Quercetin Sensing by Two Common Electrochemical Methods
Quercetin (Qu) is one of the most abundant flavonoids in the human diet. High concentrations of Qu can easily cause adverse effects and induce inflammation, joint pain and stiffness. In this study, Heme was used as a sensitive element and deposited and formed nanorods on a glassy carbon electrode (GCE) for the detection of Qu. The Heme/GCE sensor was characterized using scanning electron microscopy (SEM), cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) techniques. Under optimized conditions, the developed sensor presented a linear concentration ranging from 0.1 to 700 μmol·L−1 according to the CV and DPV methods. The detection limit for the sensor was 0.134 μmol·L−1 and its sensitivity was 0.12 μA·μM−1·cm−2, which were obtained from CV analysis. Through DPV analysis we obtained a detection limit of 0.063 μmol·L−1 and a sensitivity of 0.09 μA·μM−1·cm−2. Finally, this sensor was used to detect the Qu concentration in loquat leaf powder extract, with recovery between 98.55–102.89% and total R.S.D. lower than 3.70%. The constructed electrochemical sensor showed good anti-interference, repeatability and stability, indicating that it is also usable for the rapid detection of Qu in actual samples.
- 7 December 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (12) , 1519
Open AccessConvenient Heme Nanorod Modified Electrode for Quercetin Sensing by Two Common Electrochemical Methods
Quercetin (Qu) is one of the most abundant flavonoids in the human diet. High concentrations of Qu can easily cause adverse effects and induce inflammation, joint pain and stiffness. In this study, Heme was used as a sensitive element and deposited and formed nanorods on a glassy carbon electrode (GCE) for the detection of Qu. The Heme/GCE sensor was characterized using scanning electron microscopy (SEM), cyclic voltammetry (CV), differential pulse voltammetry (DPV) and electrochemical impedance spectroscopy (EIS) techniques. Under optimized conditions, the developed sensor presented a linear concentration ranging from 0.1 to 700 μmol·L−1 according to the CV and DPV methods. The detection limit for the sensor was 0.134 μmol·L−1 and its sensitivity was 0.12 μA·μM−1·cm−2, which were obtained from CV analysis. Through DPV analysis we obtained a detection limit of 0.063 μmol·L−1 and a sensitivity of 0.09 μA·μM−1·cm−2. Finally, this sensor was used to detect the Qu concentration in loquat leaf powder extract, with recovery between 98.55–102.89% and total R.S.D. lower than 3.70%. The constructed electrochemical sensor showed good anti-interference, repeatability and stability, indicating that it is also usable for the rapid detection of Qu in actual samples.