BDBiswanath Dekaraja

Biswanath Dekaraja

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Biswanath Dekaraja has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Enhancing the performance of consolidated voltage–frequency control of multi‐area hybrid interconnected power systems using electric vehicles

    by Biswanath Dekaraja, Lalit Chandra Saikia

    Electricity consumers desire a reliable and uninterrupted power supply for their equipment. Frequency and voltage are fluctuated due to the increase in intermittent renewable sources in the power systems. To mitigate these problems, a novel multi‐term fractional‐order PID (MFOPID) controller is proposed for improving the combined voltage‐frequency control of a three‐area hydrothermal system (THS) that incorporates a realistic dish‐Stirling solar thermal system (RDSTS). Suitable nonlinearity constraints are considered in both thermal‐hydro units. The proposed controller parameters are optimized using the artificial flora algorithm. Electric vehicle (EV) fleets have been introduced for the first time into the system under consideration. The MFOPID controller outperforms the PID with filter coefficient (PIDN) controller, according to a comparative assessment of the system dynamic responses under various investigations. Investigations exhibit that the system dynamic performance marginally degrades after the incorporation of the RDSTS into all control area of the three‐area THS. The analysis reveals that the assimilation of EVs into the considered system provides better system damping and reduces oscillations and peak deviations. The efficiency of electric vehicles is influenced by battery state‐of‐charge (SOC). The system performance deteriorates when the SOC of the EVs is more than 80% charging and less than 50% discharging at the time of disturbance. Moreover, the MFOPID controller provides a faster injection of EV power into the system during perturbation compared to the PIDN controller. Sensitivity analysis validated the MFOPID controller's sturdiness against numerous physical system conditions.


  • Performance amelioration of concerted voltage‐frequency regulation of multiarea hybrid power systems under restructured pattern using electric vehicles and interline power flow controller

    by Biswanath Dekaraja, Lalit C. Saikia, Satish K. Ramoji

    Electric power consumers need a stable and reliable electricity supply for their appliances. Voltage and frequency fluctuate owing to the gain in intermittent renewable energy sources in hybrid power systems (PSs). To mitigate these issues, this article proposed a new cascade controller named proportional‐derivative with filter and fractional‐order tilt‐integral‐derivative with filter (CPDN‐FOTIDN), controller for combined voltage and frequency control of three areas hybrid PS under deregulated environment. Hybrid PS comprises hydro, thermal, and geothermal power plant, modern electric vehicles (EVs), and interline power flow controller (IPFC). To make the analysis more realistic of the hybrid PS, more appropriate nonlinearities are considered. The artificial flora algorithm is employed for tuning controller parameters with several studies to obtain the desired response. Comparative analysis of dynamics responses reveals the superiority of the CPDN‐FOTIDN controller relative to PIDN and FOTIDN controllers under the three different power transactions. Investigations exhibited the performance enhancement of combined voltage and frequency control of hybrid PS after the integration of EVs into the considered system. Simulation results show that the EVs are a quick response in the presence of a CPDN‐FOTIDN controller compared to TID, and FOTID controllers during the system disturbance. Inter‐area oscillations improve after integration of IPFC into the system and the optimal location was found between area 1 and 2. Sensitivity studies demonstrated the sturdiness of the proposed controller against a wide variation of the system loading.


  • Impact of Electric Vehicles and Wind Turbine in Combined ALFC and AVR Studies Using AFA-Optimized CFPD-PIDN Controller

    by Biswanath Dekaraja, Lalit Chandra Saikia, Satish Kumar Ramoji, Manoja Kumar Behera, Sanjeev Kumar Bhagat, Arinditi Saha, Naladi Ram Babu


  • Impact of RFB and PLL Dynamic on Combined ALFC-AVR Regulation of Multiarea Multisource System Under Deregulated Environment with AC/Accurate HVDC link

    by Biswanath Dekaraja, Lalit Chandra Saikia

    The paper discusses the coordinated effect of redox flow battery (RFB) and accurate high voltage dc (AHVDC) link on the combined voltage and frequency control of two-area systems under deregulated environment. Each area has three generating companies (GENCOs) and three distribution companies. GENCOs in Area-1 are thermal, realistic dish-Stirling solar thermal system (RDSTS) and solar thermal power plants, and in Area-2 GENCOs are hydro, RDSTS, and geothermal power plants. Appropriate nonlinearity constraints are equipped with both hydro and thermal units. A maiden attempt has been made to employ a cascaded fractional-order PD with filter and PID with filter (CFOPDN-PIDN) as a secondary controller for the considered system. Artificial flora algorithm is used to optimize the controller parameters under various system conditions. The proposed CFOPDN-PIDN controller yields better system dynamic responses than the PIDN controller for the Poolco, bilateral, and contract violation power transactions. The investigations reveal that the parallel operation of the AC/AHVDC links deteriorates the system dynamics having more oscillations and peak deviations compared to individual AC and AHVDC links. The dynamic effect of Phase-Lock-Loop (PLL) is important for the realistic operation of AHVDC link. A novel approach for analyzing the dynamic effect of the AHVDC links considering PLL effects during the coordination with the AC system is presented. By adding the dynamic model of PLL to the parallel AC/AHVDC link, the system's performance is improved. The analysis reflects that the RFB-AHVDC links with PLL dynamics provided better system damping than the RFB-AC tie-line and AC tie-line alone.


  • Impact of electric vehicles and realistic dish‐Stirling solar thermal system on combined voltage and frequency regulation of multiarea hydrothermal system

    by Biswanath Dekaraja, Lalit Chandra Saikia

    The effective and reliable operation of an interconnected power system (PS) is a major concern, because of the large amount of power contribution from the intermittent renewable energy sources to the power grid. Energy storage (ES) devices are employed to enhance the reliability of the PS operation. Electric vehicles (EVs) are a novel type of distributed ES device that may be utilized to compensate for power imbalances. This paper discusses the participation of EVs for combined frequency and voltage control under conventional PS along with a thermal, hydro, realistic dish‐Stirling solar thermal system (RDSTS). Appropriate physical constraints such as governor dead band and generation rate constraints are equipped with thermal and hydro plants, and communication delay between the generating unit and load dispatch center is considered. An aggregate EVs model, RDSTS, and a new cascade controller named fractional‐order proportional‐derivative with filter coefficient cascaded with tilt‐integral‐derivative (CFOPDN‐TID) controller are provided in all areas for various studies. An artificial flora algorithm is employed to determine the optimal value of the various controller parameters under several scenarios. The system dynamics of the CFOPDN‐TID controller outperform the proportional‐integral‐derivative (PID) and TID controllers under various conditions. The incorporation of EVs improves the system performance in terms of less settling time, and peak deviation, and reduce oscillations. The system performance degrades with increases in the communication time delay of the EVs. The integration of RDSTS into the system provides better dynamics than the dish‐Stirling solar thermal system. Numerous studies have been conducted to validate the robustness of the proposed CFOPDN‐TID controller.


  • Coordinated Control of ALFC-AVR in Multiarea Multisource Systems Integrated with VRFB and TCPS Using CFPDN-PIDN Controller

    by Biswanath Dekaraja, Lalit Chandra Saikia

    The article discusses the coordinated effect of the vanadium redox flow battery (VRFB) and thyristor control phase shifter (TCPS) on combined automatic load frequency control and automatic voltage regulator of three area hydrothermal systems incorporating renewable sources. Solar thermal power plant, dish-Stirling solar thermal system, and geothermal power plant are integrated into Area-I, Area-II, and Area-III, respectively. Suitable generation rate constraint and governor dead-band are considered for both thermal and hydro plants. A new fuzzy logic-based cascaded controller named fuzzy proportional-derivative with filter coefficient cascaded with proportional-integral-derivative with filter coefficient (CFPDN-PIDN) is proposed as a secondary controller and its performance is compared with the PIDN and CPDN-PIDN controllers. Various controller parameters are optimized by the artificial flora algorithm. Simulation results reveal that the CFPDN-PIDN controller outperforms the PIDN and CPDN-PIDN controllers. Two types of control schemes are used to regulate the TCPS's phase angle variation: Type-I is a first-order lag transfer function, while Type-II includes a washout filter and lead-lag compensator along with Type-I. Analysis shows that the Type-I control strategy is better than Type-II. VRFB charging/discharging is regulated using high-pass filter (HPF) and dead-band (DB) control schemes. Investigation reveals that the BD scheme provided better system dynamics than the HPF scheme. Moreover, the system performance degrades with very high or low state-of-charge values. Further, using the best control schemes for both VRFB and TCPS, the system's dynamic performance was superior to that of the individual one. Finally, the robustness of the proposed control approach is validated through sensitivity analysis.


  • Open Access

    Impact of energy storage and flexible alternating current transmission devices in combined voltage and frequency regulation of multiarea multisource interconnected power system

    by Biswanath Dekaraja, Lalit Chandra Saikia

    This article emphasizes the impact of coordinated energy storage (ES) and flexible alternating current transmission (FACTS) devices in the combined voltage and frequency control of multi‐area systems having hydro, thermal, geothermal, and solar thermal power plants. Appropriate realistic constraints are equipped with both hydro and thermal units. A novel fuzzy logic controller‐based cascade PI and PID with filter coefficient (N), FCPI‐PIDN controller is proposed and optimized various controller parameters using artificial flora algorithm. Comparative analysis of FCPI‐PIDN, Cascade PI and PIDN (CPI‐PIDN), and PIDN controllers show the superiority of the FCPI‐PIDN controller to others. Integration of ES devices (ESDs), such as redox flow battery (RFB), capacitive energy storage (CES), and superconducting magnetic energy storage (SMES) indicates that the incorporation of ESDs enhance the system performance and RFB is superior to SMES and CES. Moreover, integration of FACTS devices, such as interline power flow controller (IPFC), thyristor control series capacitor (TCSC), and unified power flow controller (UPFC) indicates the incorporation of FACTS devices improve the system dynamic and coordination of IPFC‐RFB provide better response than TCSC‐RFB and UPFC‐RFB. Investigation reveals that the optimal location of RFB is Area 1 and IPFC is in between Areas 1 and 3. Sensitivity analysis validated the robustness of the FCPI‐PIDN controller.


  • Combined Voltage and Frequency Control of Multiarea Multisource System Using CPDN-PIDN Controller

    by Biswanath Dekaraja, Lalit Chandra Saikia

    This paper discusses a multiarea multi-source system in combined automatic load frequency control (ALFC) and an automatic voltage regulator (AVR) model. The multiarea system comprises thermal and wind in Area-1, thermal-geothermal in Area-2, and hydrothermal plant in Area-3. Appropriate nonlinearity constraints are provided for both hydro and thermal plants. A maiden attempt has been made to employ a cascade proportional-derivative (PD) with filter coefficient (N) and PID with filter coefficient (N) (CPDN-PIDN) as a secondary controller in the combined ALFC-AVR system and optimized controller gains using artificial flora algorithm (AFA). It is examined that the CPDN-PIDN controller yields better dynamics responses than the PI and PIDN controllers. Analyze reflects that the system performance enhanced in the presence of AVR loop. This paper discusses the effect of renewable sources like wind and geothermal on the system dynamics. Analysis reveals that the geothermal power plant is more reliable than the wind plant. The parameter variations of the temporary and permanent droop and hydro turbine time constant (HTTC) of the hydro plant are examined through system responses. System response deteriorates significantly as permanent droop and HTTC are reduced. Peak overshoot and undershoot are reduced considerably as the temporary droop value is increased. Sensitivity analysis reveals that the AFA optimized CPDN-PIDN controller parameters obtained under the nominal condition are resilient enough and need not be reset with the system's substantial random variation. An experimental justification has been provided of the investigated system using a real-time simulation with the OPAL-RT OP4510 real-time setup.