Davide Tore
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Davide Tore has a total of 162 co-authors. Here are the top co-authors by number of shared publications:
- Marco Gatti
Department of Surgical Sciences, Radiology Unit, University of Turin, Via Genova 3, 10126, Turin, Italy
8 shared publications Paolo Fonio
Radiology Unit, Department of Surgical Sciences, AOU Città della Salute e della Scienza di Torino, University of Turin, Turin, Italy
6 shared publications- Riccardo Faletti
Department of Surgical Sciences, Radiology Unit, University of Turin, Turin, Italy
5 shared publications - Gaetano Maria De Ferrari
Division of Cardiology, Cardiovascular and Thoracic Department, Città della Salute e della Scienza Hospital, Turin, Italy; Department of Medical Sciences, University of Turin, Turin, Italy
4 shared publications - Matteo Anselmino
Division of Cardiology, Cardiovascular and Thoracic Department, Città della Salute e della Scienza, Turin, Italy; Department of Medical Sciences, University of Turin, Turin, Italy
4 shared publications Alessandro Depaoli
Radiology Unit, Department of Surgical Sciences, University of Turin, Turin, Italy
3 shared publications
Latest Publications
- 1 December 2024
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 6 (6) , e230428
Prevalence of Mitral Annular Disjunction at Cardiac MRI: Results from a Multicenter Registry
Mitral annular disjunction (MAD) was a frequent incidental finding at cardiac MRI examinations performed for various clinical indications; longer MAD length and coexisting bileaflet mitral valve prolapse were associated with a higher prevalence of arrhythmia.
- 1 December 2024
- Published by Radiological Society of North America (RSNA) in Radiology: Cardiothoracic Imaging
- Vol. 6 (6) , e230428
Prevalence of Mitral Annular Disjunction at Cardiac MRI: Results from a Multicenter Registry
Mitral annular disjunction (MAD) was a frequent incidental finding at cardiac MRI examinations performed for various clinical indications; longer MAD length and coexisting bileaflet mitral valve prolapse were associated with a higher prevalence of arrhythmia.
- Open Access
- 28 April 2024
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 11 (5) , 137
Epicardial Atrial Fat at Cardiac Magnetic Resonance Imaging and AF Recurrence after Transcatheter Ablation
The relationship between epicardial adipose tissue (EAT) and atrial fibrillation (AF) has gained interest in recent years. The previous literature on the topic presents great heterogeneity, focusing especially on computed tomography imaging. The aim of the present study is to determine whether an increased volume of left atrial (LA) EAT evaluated at routine pre-procedural cardiac magnetic resonance imaging (MRI) relates to AF recurrences after catheter ablation. A total of 50 patients undergoing AF cryoballoon ablation and pre-procedural cardiac MRI allowing quantification of LA EAT were enrolled. In one patient, the segmentation of LA EAT could not be achieved. After a median follow-up of 16.0 months, AF recurrences occurred in 17 patients (34%). The absolute volume of EAT was not different in patients with and without AF recurrences (10.35 mL vs. 10.29 mL; p-value = 0.963), whereas the volume of EAT indexed on the LA volume (EATi) was lower, albeit non-statistically significant, in patients free from arrhythmias (12.77% vs. 14.06%; p-value = 0.467). The receiver operating characteristic curve testing the ability of LA EATi to predict AF recurrence after catheter ablation showed sub-optimal performance (AUC: 0.588). The finest identified cut-off of LA EATi was 10.65%, achieving a sensitivity of 0.5, a specificity of 0.82, a positive predictive value of 0.59 and a negative predictive value of 0.76. Patients with values of LA EATi lower than 10.65% showed greater survival, free from arrhythmias, than patients with values above this cut-off (84% vs. 48%; p-value = 0.04). In conclusion, EAT volume indexed on the LA volume evaluated at cardiac MRI emerges as a possible independent predictor of arrhythmia recurrence after AF cryoballoon ablation. Nevertheless, prospective studies are needed to confirm this finding and eventually sustain routine EAT evaluation in the management of patients undergoing AF catheter ablation.
- 28 April 2024
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 11 (5) , 137
Open AccessEpicardial Atrial Fat at Cardiac Magnetic Resonance Imaging and AF Recurrence after Transcatheter Ablation
The relationship between epicardial adipose tissue (EAT) and atrial fibrillation (AF) has gained interest in recent years. The previous literature on the topic presents great heterogeneity, focusing especially on computed tomography imaging. The aim of the present study is to determine whether an increased volume of left atrial (LA) EAT evaluated at routine pre-procedural cardiac magnetic resonance imaging (MRI) relates to AF recurrences after catheter ablation. A total of 50 patients undergoing AF cryoballoon ablation and pre-procedural cardiac MRI allowing quantification of LA EAT were enrolled. In one patient, the segmentation of LA EAT could not be achieved. After a median follow-up of 16.0 months, AF recurrences occurred in 17 patients (34%). The absolute volume of EAT was not different in patients with and without AF recurrences (10.35 mL vs. 10.29 mL; p-value = 0.963), whereas the volume of EAT indexed on the LA volume (EATi) was lower, albeit non-statistically significant, in patients free from arrhythmias (12.77% vs. 14.06%; p-value = 0.467). The receiver operating characteristic curve testing the ability of LA EATi to predict AF recurrence after catheter ablation showed sub-optimal performance (AUC: 0.588). The finest identified cut-off of LA EATi was 10.65%, achieving a sensitivity of 0.5, a specificity of 0.82, a positive predictive value of 0.59 and a negative predictive value of 0.76. Patients with values of LA EATi lower than 10.65% showed greater survival, free from arrhythmias, than patients with values above this cut-off (84% vs. 48%; p-value = 0.04). In conclusion, EAT volume indexed on the LA volume evaluated at cardiac MRI emerges as a possible independent predictor of arrhythmia recurrence after AF cryoballoon ablation. Nevertheless, prospective studies are needed to confirm this finding and eventually sustain routine EAT evaluation in the management of patients undergoing AF catheter ablation.
- Open Access
- 19 December 2023
- Published by MDPI AG in Preprints.org
Epicardial Atrial Fat at Cardiac Magnetic Resonance Imaging and AF Recurrence after Transcatheter Ablation
The relationship between epicardial adipose tissue (EAT) and atrial fibrillation (AF) has gained interest in recent years. Previous literature on the topic presents great heterogeneity, focusing especially on computed tomog-raphy imaging. Aim of the present study is to determine whether an increased volume of left atrial (LA) EAT evaluated at routine pre-procedural cardiac magnetic resonance imaging (MRI) relates to AF recurrences after catheter ablation. 50 patients undergoing AF cryoballoon ablation and pre-procedural cardiac MRI allowing quantification of LA EAT were enrolled. In one patient segmentation of LA EAT could not be achieved. After a median follow-up of 16.0 months, AF recurrences occurred in 17 patients (34%). Absolute volume of EAT was not different in patients with and without AF recurrences (10.35 ml vs. 10.29 ml; p-value=0.963), whereas volume of EAT indexed on the LA (EATi) was lower, albeit non statistically significant, in patients free from arrhythmias (12.77% vs. 14.06%; p-value=0.467). Receiver operating characteristic curve testing the ability of EATi to predict AF recurrence after catheter ablation showed sub-optimal performance (AUC: 0.588). The finest identified cut-off of EATi was 10.65%, achieving a sensitivity of 0.5, a specificity of 0.82, a positive predictive value of 0.59 and a negative predictive value of 0.76. Patients with values of EATi lower than 10.65% showed greater survival free from arrhythmias than patients with values above this cut-off (84% vs. 48%; p-value=0.04). In conclusion, indexed LA EAT volume evaluated at cardiac MRI independently relates to arrhythmia recurrence after AF cryoballoon ablation.
- 19 December 2023
- Published by MDPI AG in Preprints.org
Open AccessEpicardial Atrial Fat at Cardiac Magnetic Resonance Imaging and AF Recurrence after Transcatheter Ablation
The relationship between epicardial adipose tissue (EAT) and atrial fibrillation (AF) has gained interest in recent years. Previous literature on the topic presents great heterogeneity, focusing especially on computed tomog-raphy imaging. Aim of the present study is to determine whether an increased volume of left atrial (LA) EAT evaluated at routine pre-procedural cardiac magnetic resonance imaging (MRI) relates to AF recurrences after catheter ablation. 50 patients undergoing AF cryoballoon ablation and pre-procedural cardiac MRI allowing quantification of LA EAT were enrolled. In one patient segmentation of LA EAT could not be achieved. After a median follow-up of 16.0 months, AF recurrences occurred in 17 patients (34%). Absolute volume of EAT was not different in patients with and without AF recurrences (10.35 ml vs. 10.29 ml; p-value=0.963), whereas volume of EAT indexed on the LA (EATi) was lower, albeit non statistically significant, in patients free from arrhythmias (12.77% vs. 14.06%; p-value=0.467). Receiver operating characteristic curve testing the ability of EATi to predict AF recurrence after catheter ablation showed sub-optimal performance (AUC: 0.588). The finest identified cut-off of EATi was 10.65%, achieving a sensitivity of 0.5, a specificity of 0.82, a positive predictive value of 0.59 and a negative predictive value of 0.76. Patients with values of EATi lower than 10.65% showed greater survival free from arrhythmias than patients with values above this cut-off (84% vs. 48%; p-value=0.04). In conclusion, indexed LA EAT volume evaluated at cardiac MRI independently relates to arrhythmia recurrence after AF cryoballoon ablation.
- Top Cited Papers
- 4 October 2023
- Published by Elsevier in JACC: Cardiovascular Imaging
- Vol. 16 (12) , 1584-1604
Coronary Plaque Characteristics Associated With Major Adverse Cardiovascular Events in Atherosclerotic Patients and Lesions
- 4 October 2023
- Published by Elsevier in JACC: Cardiovascular Imaging
- Vol. 16 (12) , 1584-1604
Top Cited PapersCoronary Plaque Characteristics Associated With Major Adverse Cardiovascular Events in Atherosclerotic Patients and Lesions
- Open Access
- 14 September 2023
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 10 (9) , 396
Evaluation of Pulmonary Vein Fibrosis Following Cryoballoon Ablation of Atrial Fibrillation: A Semi-Automatic MRI Analysis
Current guidelines recommend the use of cardiac magnetic resonance imaging (MRI) for the management of atrial fibrillation (AF). However, the widespread use of cardiac MRI in clinical practice is difficult to achieve. The aim of the present study is to assess whether cardiac MRI can be adopted to identify ablation-induced fibrosis, and its relationship with AF recurrences. Fifty patients undergoing AF cryoballoon ablation were prospectively enrolled. Cardiac MRI was performed before and 30 days after the index ablation. Commercially available software and a specifically designed image processing workflow were used to quantify left atrium (LA) fibroses. Thirty-six patients were finally included in the analysis; twenty-eight were analyzed with the dedicated workflow. Acute electrical isolation was achieved in 98% of the treated pulmonary veins (PVs). After a median follow-up of 16 months, AF recurrences occurred in 12 patients (33%). In both analyses, no differences were found between the subgroups of patients with and without recurrence in the variation of either LA fibrosis or fibrosis at the ostium of the PV, before and after ablation. The ability to predict arrhythmic recurrences evaluated via the ROC curve of the variations in both LA fibrosis (AUC 0.566) and PV fibrosis (AUC 0.600) was low. Cardiac MRI holds the potential to provide clinically significant information on LA disease and AF progression; however, LA fibrosis cannot be easily identified, either by currently available commercial programs or custom tools.
- 14 September 2023
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 10 (9) , 396
Open AccessEvaluation of Pulmonary Vein Fibrosis Following Cryoballoon Ablation of Atrial Fibrillation: A Semi-Automatic MRI Analysis
Current guidelines recommend the use of cardiac magnetic resonance imaging (MRI) for the management of atrial fibrillation (AF). However, the widespread use of cardiac MRI in clinical practice is difficult to achieve. The aim of the present study is to assess whether cardiac MRI can be adopted to identify ablation-induced fibrosis, and its relationship with AF recurrences. Fifty patients undergoing AF cryoballoon ablation were prospectively enrolled. Cardiac MRI was performed before and 30 days after the index ablation. Commercially available software and a specifically designed image processing workflow were used to quantify left atrium (LA) fibroses. Thirty-six patients were finally included in the analysis; twenty-eight were analyzed with the dedicated workflow. Acute electrical isolation was achieved in 98% of the treated pulmonary veins (PVs). After a median follow-up of 16 months, AF recurrences occurred in 12 patients (33%). In both analyses, no differences were found between the subgroups of patients with and without recurrence in the variation of either LA fibrosis or fibrosis at the ostium of the PV, before and after ablation. The ability to predict arrhythmic recurrences evaluated via the ROC curve of the variations in both LA fibrosis (AUC 0.566) and PV fibrosis (AUC 0.600) was low. Cardiac MRI holds the potential to provide clinically significant information on LA disease and AF progression; however, LA fibrosis cannot be easily identified, either by currently available commercial programs or custom tools.
- Open Access
- 4 November 2022
- Published by MDPI AG in Journal of Imaging
- Vol. 8 (11) , 300
Role of Cardiovascular Magnetic Resonance in the Management of Atrial Fibrillation: A Review
Atrial fibrillation (AF) is the most common arrhythmia, and its prevalence is growing with time. Since the introduction of catheter ablation procedures for the treatment of AF, cardiovascular magnetic resonance (CMR) has had an increasingly important role for the treatment of this pathology both in clinical practice and as a research tool to provide insight into the arrhythmic substrate. The most common applications of CMR for AF catheter ablation are the angiographic study of the pulmonary veins, the sizing of the left atrium (LA), and the evaluation of the left atrial appendage (LAA) for stroke risk assessment. Moreover, CMR may provide useful information about esophageal anatomical relationship to LA to prevent thermal injuries during ablation procedures. The use of late gadolinium enhancement (LGE) imaging allows to evaluate the burden of atrial fibrosis before the ablation procedure and to assess procedural induced scarring. Recently, the possibility to assess atrial function, strain, and the burden of cardiac adipose tissue with CMR has provided more elements for risk stratification and clinical decision making in the setting of catheter ablation planning of AF. The purpose of this review is to provide a comprehensive overview of the potential applications of CMR in the workup of ablation procedures for atrial fibrillation.
- 4 November 2022
- Published by MDPI AG in Journal of Imaging
- Vol. 8 (11) , 300
Open AccessRole of Cardiovascular Magnetic Resonance in the Management of Atrial Fibrillation: A Review
Atrial fibrillation (AF) is the most common arrhythmia, and its prevalence is growing with time. Since the introduction of catheter ablation procedures for the treatment of AF, cardiovascular magnetic resonance (CMR) has had an increasingly important role for the treatment of this pathology both in clinical practice and as a research tool to provide insight into the arrhythmic substrate. The most common applications of CMR for AF catheter ablation are the angiographic study of the pulmonary veins, the sizing of the left atrium (LA), and the evaluation of the left atrial appendage (LAA) for stroke risk assessment. Moreover, CMR may provide useful information about esophageal anatomical relationship to LA to prevent thermal injuries during ablation procedures. The use of late gadolinium enhancement (LGE) imaging allows to evaluate the burden of atrial fibrosis before the ablation procedure and to assess procedural induced scarring. Recently, the possibility to assess atrial function, strain, and the burden of cardiac adipose tissue with CMR has provided more elements for risk stratification and clinical decision making in the setting of catheter ablation planning of AF. The purpose of this review is to provide a comprehensive overview of the potential applications of CMR in the workup of ablation procedures for atrial fibrillation.
- 1 May 2022
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 16 (3) , 207-214
Impact of computed-tomography defined sarcopenia on outcomes of older adults undergoing transcatheter aortic valve implantation
- 1 May 2022
- Published by Elsevier in Journal of Cardiovascular Computed Tomography
- Vol. 16 (3) , 207-214
Impact of computed-tomography defined sarcopenia on outcomes of older adults undergoing transcatheter aortic valve implantation
- Open Access
- 17 November 2021
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 11
Ultra-Low-Dose Whole-Body Computed Tomography Protocol Optimization for Patients With Plasma Cell Disorders: Diagnostic Accuracy and Effective Dose Analysis From a Reference Center
Background: The whole-body low-dose CT (WBLDCT) is the first-choice imaging technique in patients with suspected plasma cell disorder to assess the presence of osteolytic lesions. We investigated the performances of an optimized protocol, evaluating diagnostic accuracy and effective patient dose reduction using a latest generation scanner.Methods and Materials: Retrospective study on 212 patients with plasma cell disorders performed on a 256-row CT scanner. First, WBLDCT examinations were performed using a reference protocol with acquisition parameters obtained from literature. A phantom study was performed for protocol optimization for subsequent exams to minimize dose while maintaining optimal diagnostic accuracy. Images were analyzed by three readers to evaluate image quality and to detect lesions. Effective doses (E) were evaluated for each patient considering the patient dimensions and the tube current modulation.Results: A similar, very good image quality was observed for both protocols by all readers with a good agreement at repeated measures ANOVA test (p>0.05). An excellent inter-rater agreement for lesion detection was achieved obtaining high values of Fleiss’ kappa for all the districts considered (p<0.001). The optimized protocol resulted in a 56% reduction of median DLP (151) mGycm, interquartile range (IQR) 128–188 mGycm vs. 345 mGycm, IQR 302–408 mGycm), of 60% of CTDIvol (2.2 mGy, IQR 1.9–2.7 mGy vs. 0.9 mGy, IQR 0.8–1.2 mGy). The median E value was about 2.6 mSv (IQR 1.7–3.5 mSv) for standard protocol and about 1.5 mSv (IQR 1.4–1.7 mSv) for the optimized one. Dose reduction was statistically significant with p<0.001.Conclusions: Protocol optimization makes ultra-low-dose WBLDCT feasible on latest generation CT scanners for patients with plasma cell disorders with effective doses inferior to conventional skeletal survey while maintaining excellent image quality and diagnostic accuracy. Dose reduction is crucial in such patients, as they are likely to undergo multiple whole-body CT scans during follow-up.
- 17 November 2021
- Published by Frontiers Media SA in Frontiers in Oncology
- Vol. 11
Open AccessUltra-Low-Dose Whole-Body Computed Tomography Protocol Optimization for Patients With Plasma Cell Disorders: Diagnostic Accuracy and Effective Dose Analysis From a Reference Center
Background: The whole-body low-dose CT (WBLDCT) is the first-choice imaging technique in patients with suspected plasma cell disorder to assess the presence of osteolytic lesions. We investigated the performances of an optimized protocol, evaluating diagnostic accuracy and effective patient dose reduction using a latest generation scanner.Methods and Materials: Retrospective study on 212 patients with plasma cell disorders performed on a 256-row CT scanner. First, WBLDCT examinations were performed using a reference protocol with acquisition parameters obtained from literature. A phantom study was performed for protocol optimization for subsequent exams to minimize dose while maintaining optimal diagnostic accuracy. Images were analyzed by three readers to evaluate image quality and to detect lesions. Effective doses (E) were evaluated for each patient considering the patient dimensions and the tube current modulation.Results: A similar, very good image quality was observed for both protocols by all readers with a good agreement at repeated measures ANOVA test (p>0.05). An excellent inter-rater agreement for lesion detection was achieved obtaining high values of Fleiss’ kappa for all the districts considered (p<0.001). The optimized protocol resulted in a 56% reduction of median DLP (151) mGycm, interquartile range (IQR) 128–188 mGycm vs. 345 mGycm, IQR 302–408 mGycm), of 60% of CTDIvol (2.2 mGy, IQR 1.9–2.7 mGy vs. 0.9 mGy, IQR 0.8–1.2 mGy). The median E value was about 2.6 mSv (IQR 1.7–3.5 mSv) for standard protocol and about 1.5 mSv (IQR 1.4–1.7 mSv) for the optimized one. Dose reduction was statistically significant with p<0.001.Conclusions: Protocol optimization makes ultra-low-dose WBLDCT feasible on latest generation CT scanners for patients with plasma cell disorders with effective doses inferior to conventional skeletal survey while maintaining excellent image quality and diagnostic accuracy. Dose reduction is crucial in such patients, as they are likely to undergo multiple whole-body CT scans during follow-up.