PRPragnyashree Ray

Pragnyashree Ray

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Pragnyashree Ray has a total of 12 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Adaptive Control of a PV‐Integrated Unified Power Quality Conditioner for Remote Low‐Voltage Distribution Networks

    by Pragnyashree Ray, Laxmidhar Senapati, Pradyumna Kumar Behera, Alivarani Mohapatra, Theophilus A. T. Kambo, Soumyakanta Samantaray, Buddhadeva Sahoo

    The increasing penetration of distributed energy resources (DERs) in low‐voltage distribution networks, driven by renewable energy integration, has introduced significant power quality (PQ) challenges due to extensive power electronic converters interfacing. This paper presents a solar photovoltaic (PV) powered unified PQ conditioner (UPQC) with an advanced adaptive control strategy based on the variable leaky least mean square (VLLMS) algorithm for simultaneous PQ improvement and distributed power management. The proposed controller enables fast extraction and decoupling of non‐ideal grid voltage and load current components without the use of low‐pass or moving‐average filters, resulting in improved convergence speed and real‐time controllability. A PV power feed‐forward term is incorporated into the shunt converter control to enhance DC‐link voltage regulation under fluctuating PV generation. Coordinated operation of the series and shunt converters ensures stable load voltage and unity power factor (UPF) at the point of common coupling (P.C.C) during grid disturbances and nonlinear loading conditions. The adaptive leakage factor based control mechanism prevents parameter drift under dynamic operating conditions. The effectiveness of the proposed PV‐UPQC is verified through MATLAB/Simulink simulations and experimental results, demonstrating superior steady‐state and transient performance compared with conventional UPQC control schemes, making it suitable for renewable‐rich distribution networks.

  • Performance Improvement of Microgrid With Strategic Control of Distributed Energy Resources Integrated UPQC

    by Pragnyashree Ray, Pravat Kumar Ray, Pratap Sekhar Puhan, M. L.THaruth Kavinda Liyanage

    Microgrid has emerged as an effective solution for incorporation of distributed energy resources (DERs) to suffice the intensifying energy demand, meanwhile contributing towards sustainable development of power sector. However, with this progressive transformation, the quality and reliability of power is significantly affected particularly in the remotely placed low voltage small-scale microgrid due to its low inertia. Therefore, the proposed work focuses on the performance improvement of low voltage microgrid by integration of photovoltaic (PV) and battery energy storage system (BESS) fed unified power quality conditioner (UPQC). The control scheme of UPQC is deliberated to deliver multiple benefits of power quality improvement, maximum deployment of PV by employing BESS, reduced burden on grid and swift regulation of DC-link voltage under various system dynamics. Hence, eliminates the requirement of extra converter for interfacing PV and BESS with grid. Additionally, a switch protection strategy is incorporated in UPQC control algorithm. Without any modification in the system configuration and capacity, it prevents the UPQC switches from damage due to very high magnitude of current during any load induced uncertain scenario. BESS controller operates by using dynamic battery reference power which is updated with respect to the dynamics of load demand, PV power and battery state of charge (SOC). Evaluation of the proposed system is performed through MATLAB/Simulink and experimental prototype by imposing various dynamics conditions.


  • Performance Enhancement of PV-UPQC With Integration of Battery Energy Storage System at the DC-Link to Support Sensitive Consumer Loads

    by Pragnyashree Ray, Pravat Kumar Ray

    The proposed work illustrates an adaptive and coordinated control of battery energy storage system (BESS) supported photovoltaic fed unified power quality conditioner (PV-UPQC) to satiate the power quality requirements of sensitive consumers for their unperturbed and unpenalized operation under non-ideal grid and load condition. For grid synchronised unity power factor operation at point of common coupling (P.C.C), cross-coupled cascaded integral action (CCIA) based filter is used to accurately generate grid in-phase unit templates, magnitude of fundamental component of non-ideal voltage and current. Also, efficient regulation of DC-link voltage under grid voltage sag and PV intermittency is a significant concern. As per system configuration, power required for in-phase grid voltage sag compensation depends upon the amount of grid current flowing through injection transformer. Here, the objective is to reduce the grid current during sag to lessen the sag compensating power. Hence, incorporation of BESS across the DC-link with PV minimises the burden on the grid subsequently reduces sag compensating power and also facilitates optimum utilization of PV power with smooth regulation of DC-link voltage under varying PV characteristics. To harness the benefits effectively under such dynamic scenario, an adaptively updating factor is introduced in the evaluation of battery feed-forward component and battery reference current for UPQC (shunt) and BESS controller respectively. The effectiveness of proposed improvisations are verified through simulation study and experimental implementation on a developed prototype of proposed system under all possible system dynamics.


  • An ANF Cascaded Normalized-CF-SOHO Based Control Approach and Analysis of PV-UPQC Under Highly Non-Ideal Grid and Load Conditions

    by Pragnyashree Ray, Pravat Kumar Ray, Bhanu Pratap Behera, Naresh Singh

    Controlling and conditioning electrical power to be delivered to the critical commercial load is very crucial under non-ideal grid and load conditions. Accordingly, PV-fed UPQC (Photovoltaic fed unified power quality conditioner) is the most suitable alternative to address both voltage and current-related issues under such non-ideal scenarios. Thus, for efficient control and power conditioning, extraction of fundamental grid parameters are the prerequisites. Fundamental frequency estimation, three-phase unit template generation and fundamental active load current component extraction are the most important procedures to carry out the control process efficiently. In the proposed work, an adaptive notch filter cascaded normalized comb filter triggered second order harmonic oscillator (N-CF-SOHO) based control of PV-UPQC is illustrated. The striking feature of this control approach is its ability to generate appropriate reference signals for switching of PV-UPQC by estimating and extracting out fundamental components from highly non-ideal grid voltage and current accurately with faster execution. Notch filters (NF) being the most remarkable digital filter in separating narrow band power signal frequency is used in the proposed work to adaptively estimate the fundamental frequency by iteratively following a variable leaky least mean square (VLLMS) based updating approach. Also, NF is employed in a modified manner to exhibit the behaviour of inverse NF to extract fundamental load current component. Utilising estimated frequency, N-CF-SOHO generates fundamental voltage unit templates necessary for the control of PV-UPQC. The presented method is computationally simple, exhibits lesser run time and is robust against noise of any frequency. The presented work is authenticated both in MATLAB/Simulink platform as well as in the developed experimental prototype justifying the above-mentioned features of the system.


  • Top Cited Papers

    Power Quality Enhancement and Power Flow Analysis of a PV Integrated UPQC System in a Distribution Network

    by Pragnyashree Ray, Pravat Kumar Ray, Santanu Kumar Dash

    Increasing awareness for green energy and sustainable energy management has accelerated the popularity for the incorporation of distributed energy resources and distributed energy storage into the distribution network and microgrid. This has proliferated the use of power electronic-based devices giving rise to a serious issue of deteriorating power quality (PQ) in the distribution system. In this context, this article presents a photovoltaic (PV) integrated unified power quality conditioner (UPQC) operating with an adaptive compensating technique based on variable leaky least mean square (VLLMS) algorithm. It is a soft computing-oriented method that offers quicker convergence to the desired condition in an iterative approach keeping the weight of the updating parameters within the specified limit. The VLLMS-based algorithm eliminates the use of low pass or moving average filter for the extraction of fundamental components from polluted source voltage and load current to generate reference signal for the switching of shunt as well as series voltage source converters (VSC) of the UPQC. Due to the involvement of feed-forward component of PV in the compensating technique of shunt VSC, it efficiently and smoothly manages power balance between grid, load, and PV besides resolving the PQ issues of current harmonics and poor power factor at PCC. It also ensures the regulation of dc-link voltage. The series converter maintains pure sinusoidal voltage at the load terminal irrespective of sag/swell and harmonics present in the grid voltage. The effectiveness of the proposed system is verified through simulation as well as hardware implementation under different static and dynamic operating conditions.