Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wiktoria Laura Drela has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Touching a Mechanical Body: The Role of Anthropomorphic Framing in Physiological Arousal When Touching a Robot

    by Konrad Maj, Paulina Grzybowicz, Wiktoria Laura Drela, Michał Olszanowski

    The growing prevalence of social robots in various fields necessitates a deeper understanding of touch in Human–Robot Interaction (HRI). This study investigates how human-initiated touch influences physiological responses during interactions with robots, considering factors such as anthropomorphic framing of robot body parts and attributed gender. Two types of anthropomorphic framings are applied: the use of anatomical body part names and assignment of male or female gender to the robot. Higher physiological arousal was observed when touching less accessible body parts than when touching more accessible body parts in both conditions. Results also indicate that using anatomical names intensifies arousal compared to the control condition. Additionally, touching the male robot resulted in higher arousal in all participants, especially when anatomical body part names were used. This study contributes to the understanding of how anthropomorphic framing and gender impact physiological arousal in touch interactions with social robots, offering valuable insights for social robotics development.


  • Open Access

    Touching a Mechanical Body: The Role of Anthropomorphic Framing in Physiological Arousal When Touching a Robot

    by Konrad Maj, Paulina Grzybowicz, Wiktoria Laura Drela, Michał Olszanowski

    The growing prevalence of social robots in various fields necessitates a deeper understanding of touch in Human-Robot Interaction (HRI). This study investigates how human-initiated touch influences physiological responses during interactions with robots, considering factors such as anthropomorphic framing of robot body parts and attributed gender. Two types of anthropomorphic framings are applied: the use of anatomical body part names and assignment of male or female gender to the robot. Higher physiological arousal is observed when touching less accessible body parts than when touching more accessible body parts in both conditions. Results also indicate that using anatomical names intensifies arousal compared to the control condition. Additionally, touching the male robot resulted in higher arousal in all participants, especially when anatomical body part names were used. This study contributes to the understanding of how anthropomorphic framing and gender impact physiological arousal in touch interactions with social robots, offering valuable insights for social robotics development.

  • Open Access

    Performance of Copeptin for Early Diagnosis of Acute Coronary Syndromes: A Systematic Review and Meta-Analysis of 14,139 Patients

    by Lukasz Szarpak, Marcin Lapinski, Aleksandra Gasecka, Michal Pruc, Wiktoria L. Drela, Mariusz Koda, Andrea Denegri, Frank W. Peacock, Miłosz J. Jaguszewski, Krzysztof J. Filipiak

    Diagnosis of acute coronary syndrome (ACS) based on copeptin level may enable one to confirm or rule-out acute myocardial infarction (AMI) with higher sensitivity and specificity, which may in turn further reduce mortality rate and decrease the economic costs of ACS treatment. We conducted a systematic review and meta-analysis to investigate the relationship between copeptin levels and type of ACS. We searched Scopus, PubMed, Web of Science, Embase, and Cochrane to locate all articles published up to 10 October 2021. We evaluated a meta-analysis with random-effects models to evaluate differences in copeptin levels. A total of 14,139 patients (4565 with ACS) were included from twenty-seven studies. Copeptin levels in AMI and non-AMI groups varied and amounted to 68.7 ± 74.7 versus 14.8 ± 19.9 pmol/L (SMD = 2.63; 95% CI: 2.02 to 3.24; p < 0.001). Copeptin levels in the AMI group was higher than in the unstable angina (UAP) group, at 51.9 ± 52.5 versus 12.8 ± 19.7 pmol/L (SMD = 1.53; 95% CI: 0.86 to 2.20; p < 0.001). Copeptin levels in ST-elevation myocardial infarction (STEMI) versus non-ST elevation myocardial infarction (NSTEMI) patient groups were 54.8 ± 53.0 versus 28.7 ± 46.8 pmol/L, respectively (SMD = 1.69; 95% CI: = 0.70 to 4.09; p = 0.17). In summary, elevated copeptin levels were observed in patients with ACS compared with patients without ACS. Given its clinical value, copeptin levels may be included in the assessment of patients with ACS as well as for the initial differentiation of ACS.


  • Open Access

    Direct vs. Video-Laryngoscopy for Intubation by Paramedics of Simulated COVID-19 Patients under Cardiopulmonary Resuscitation: A Randomized Crossover Trial

    by Leszek Gadek, Lukasz Szarpak, Lars Konge, Marek Dabrowski, Dominika Telecka-Gadek, Maciej Maslanka, Wiktoria Laura Drela, Marta Jachowicz, Lukasz Iskrzycki, Szymon Bialka, et al.

    A safe way of securing the airway with an endotracheal tube is one of the priorities of an advanced cardiovascular life support algorithm for suspected or confirmed COVID-19 patients. The aim of this study was to compare intubation success rates (ISR) and intubation time (IT) of different laryngoscopes for simulated COVID-19 patients under cardiopulmonary resuscitation. The study was designed as a prospective, randomized, crossover trial. Fifty four active paramedics performed endotracheal intubation with a Macintosh direct laryngoscope (MAC) and McGrath videolaryngoscope (McGrath) with and without personal protective equipment (PPE). Without PPE, ISRs were 87% and 98% for MAC and McGrath, respectively (p = 0.32). ITs were 22.5 s (IQR: 19–26) and 19.5 s (IQR: 17–21) for MAC and McGrath, respectively (p = 0.005). With PPE, first-pass ISR were 30% and 89% with MAC and McGrath, respectively (p < 0.001). The overall success rates were 83% vs. 100% (p = 0.002). Median ITs were 34.0 s (IQR: 29.5–38.5) and 24.8 s (IQR: 21–29) for MAC and McGrath, respectively (p < 0.001). In conclusion, the McGrath videolaryngoscope appears to possess significant advantages over the Macintosh direct laryngoscope when used by paramedics in suspected or confirmed COVID-19 intubation scenarios.