PMPaul C. McAfee

Paul C. McAfee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Paul C. McAfee has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Three-Dimensional Printed Anterior Cervical Standalone Combined Cage-Plate—300 Consecutive Medical Implants

    by Mosope Soda, Bradley Moatz, Paul Asdourian, Daina Brooks, Bryan Cunningham, Paul C. McAfee

    Objective: The primary objective was to investigate the perioperative parameters and clinical outcomes of a novel three-dimensional (3D) printed titanium interbody spacer and integral screws. The secondary objective was to compare the survivorship rate of the 3D-printed titanium integrated spacer (3D-printed spacer group) with that of a polyether-ether-ketone (PEEK) integrated spacer (PEEK group) and traditional allograft spacer combined with an anterior cervical plate (control group). Study Design: This is a retrospective study comprising 157 consecutive patients (representing 300 surgical levels) investigating the perioperative and clinical outcomes of a novel 3D-printed titanium integrated spacer for anterior cervical diskectomy and fusion (ACDF). Methods: A consecutive series of 157 patients (N = 300 surgical levels) presenting with cervical radiculopathy, myelopathy, or spondylosis underwent ACDF with the 3D-printed titanium spacer. Perioperative outcomes including surgical time, estimated blood loss, length of hospital stay, and number of surgical levels were collected. Clinical outcomes including the American Spinal Injury Association neurologic impairment score and Neck Disability Index (NDI) were measured preoperatively and postoperatively. Survivorship was defined as no failures, no anterior revision surgeries, no instrumentation removals, and no subsidence requiring surgery. Results: The mean surgical time for the 3D-printed spacer group was 126.3 ± 34.0 minutes, the estimated blood loss was 85.9 ± 30.5 cc, and the length of hospital stay was 1.5 ± 1.4 days. Surgical levels were distributed as follows: 33.8% single-level, 42.7% two-level, 21.6% three-level, and 1.9% four-level ACDF procedures. 98.7% of patients in the 3D-printed spacer group reported improved American Spinal Injury Association scores. The mean NDI preoperatively was 37.2 ± 18.7, and the mean NDI postoperatively was 21.2 ± 18.3, with 58.6% of patients reporting NDI improvement of 15% or greater. Survivorship was observed in 97.4% of patients in the 3D-printed spacer group, 98.0% in the PEEK group, and 93.3% in the control group (chi-square analysis: X2 [1, N = 1529] = 16.9, P = 0.0002). Conclusion: A novel 3D-printed titanium spacer with integral screws for ACDF demonstrated improved survivorship rates compared with the traditional allograft spacer and anterior plate. Among 157 patients, only two required supplemental posterior fixation, one required removal for excessive kyphosis and were successfully revised with a 3D-printed corpectomy spacer, and one had notable subsidence at 6 weeks postoperatively (4 total failures based on the survivorship criteria; 97.4% survivorship success rate (153/157 patients)). Not a single case of neurologic progression was observed in the 3D-printed spacer group—no iatrogenic progressive radiculopathy nor myelopathy, unlike the control group.


  • Open Access

    The contribution of E3D imaging integrated with robotic navigation: analysis of the first 80 consecutive posterior spinal fusion cases

    by Jeffrey J. Stewart, Paul Asdourian, Bradley Moatz, Mosope Soda, Mesfin Lemma, Bryan W. Cunningham, Daina M. Brooks, Paul C. McAfee

    Eighty consecutive complex spinal robotic cases utilizing intraoperative 3D CT imaging (E3D, Group 2) were compared to 80 age-matched controls using the Excelsius robot alone with C-arm Fluoroscopic registration (Robot Only, Group 1). The demographics between the two groups were similar—severity of deformity, ASA Score for general anesthesia, patient age, gender, number of spinal levels instrumented, number of patients with prior spinal surgery, and amount of neurologic compression. The intraoperative CT scanning added several objective factors improving patient safety. There were significantly fewer complications in the E3D group with only 3 of 80 (4%) patients requiring a return to the operating room compared to 11 of 80 (14%) patients in the Robot Only Group requiring repeat surgery for implant related problems (Chi squared analysis = 5.00, p = 0.025). There was a significant reduction the amount of fluoroscopy time in the E3D Group (36 s, range 4–102 s) compared to Robot only group (51 s, range 15–160 s) (p = 0.0001). There was also shorter mean operative time in the E3D group (257 ± 59.5 min) compared to the robot only group (306 ± 73.8 min) due to much faster registration time (45 s). A longer registration time was required in the Robot only group to register each vertebral level with AP and Lateral fluoroscopy shots. The estimated blood loss was also significantly lower in Group 2 (mean 345 ± 225 ml) vs Group 1 (474 ± 397 ml) (p = 0.012). The mean hospital length of stay was also significantly shorter for Group 2 (3.77 ± 1.86 days) compared to Group 1 (5.16 ± 3.40) (p = 0.022). There was no significant difference in the number of interbody implants nor corrective osteotomies in both groups—Robot only 52 cases vs. 42 cases in E3D group.Level of evidence: IV, Retrospective review.


  • Innovations in Robotics and Navigation, Part 2

    by Paul C. McAfee, Isador H. Lieberman, Nicholas Theodore


  • Open Access

    Computer Simulated Enhancement and Planning, Robotics and Navigation With Patient Specific Implants and 3-D Printed Cages

    by Paul C. McAfee, Bryan W. Cunningham, Ken Mullinex, Lukas Eisermann, Daina M. Brooks

    Study Design: This is a retrospective cohort study. Objectives: Pre and postop Measurement Testing. This is a retrospective study of 33 consecutive interbody spacers in 21 patients who underwent pre, intra, and postoperative measurement of the middle column to determine if this would lead to more precise restoration of middle column height and spacer fit. Scaled transparencies of the pre-operative simulation of angular correction and spacer geometry could be overlayed on the post-operative imaging studies. Methods: Multiple Observers Measurement Testing. 33 consecutive vertebral levels requiring interbody spacers for multilevel deformities had middle column height pre and post operatively measured by 3 blinded observers. The preoperative and postoperative measurements were compared using a linear regression analysis and Pearson product-moment correlation. Results: Pre and postop Measurement Testing: Thirty-three interbody devices in 21 patients had pre-operative planning, simulation of cage dimensions to determine the proper cage fit which would provide for the desired correction of foraminal height and sagittal balance parameters. The simulated preoperative plan overlayed the final post-operative radiograph and was a near-perfect match in 20 of 21 patients (95.2%). Multiple Observers Measurement Testing: A Pearson product-moment correlation was run between each individual’s pre-op and post-op middle column measurements. There was a strong, positive correlation between pre-operative and post-operative measurements, which was statistically significant ( r = 0.903, n = 33, P < 0.001). Conclusions: This consecutive series of 33 cases demonstrated the utility of measuring the preoperative middle column length in predicting the optimal height of the spacers, intervertebral disks, and posterior vertebral body height simultaneously restoring sagittal and coronal plane alignment.


  • Open Access

    Robot for Ligament Tensioning and Assessment of Spinal Stability

    by Paul C. McAfee, Lukas Eisermann, Kenneth Mullinix

    An in vitro human cadaveric biomechanics study. A proof-of-concept study to quantify whether or not differences in segmental mobility associated with spinal instability could be detected by a robotic distraction system. Testing was performed in fresh human cadaveric tissue. A prototype Robotic Middle Column Distractor was attached unilaterally to the pedicles of L3-4. Distraction forces up to 150 N were applied first in the intact state, and following discectomy of L3-4. Motions were recorded by time-indexed visual and fluoroscopic images, and analyzed to measure actual motions achieved. Functions of the robot unit were monitored during the procedure and evaluated qualitatively. A difference of 2.5 mm in z-axis motion was detected at 150 N load between the intact and post-discectomy states. The robot coupled with the image analysis method was able to clearly detect the difference between the intact (“stable”) and post-discectomy (“unstable”) spine. Data analysis of fluoroscopic images taken during the procedure showed greater motion than perceived by the investigators from qualitative review of visual data. All monitored robot functions performed within design parameters without error. The study demonstrates the feasibility and utility of utilizing an intraoperative robotic distractor to measure the amount of spinal mobility present at a level. This could lead to an important clinical tool for both diagnostic functions as well as operative assist functions.


  • Open Access

    Innovations in Robotics and Navigation

    by Paul C. McAfee, Isador Lieberman, Nicholas Theodore

    With any emerging technology there is great anticipation and marketing; however, it is important that spinal surgeons who want cutting-edge treatment for their patients understand Everett M. Rogers' “diffusion of innovations.”1 In 1962 he outlined the theoretical participants who adopt innovative technologies and separated them into 5 distinct categories: innovators (2.5%), early adopters (13.5%), early majority (34%), late majority (34%), and laggards (16%) (Figure 1). They are modeled in 5 progressive stages initially influenced by prior conditions yet ultimately directed by peer-to-peer intercommunication: (1) knowledge, (2) persuasion, (3) decision, (4) implementation, and (5) confirmation. The distribution of adopters is usually a bell-shaped, not an S-shaped, curve. Some authors2 have already compared the advent of spinal robotics to be as impactful as the industrial revolution and spinal navigation to be similar to the penetration of the cell phone. This is an embellished opinion as there have only been 3 innovations that have deviated from the bell-shaped curve of adoption and have seen an S-shaped diffusion curve, demonstrating exponential adoption: the personal computer, the internet, and cell phones.

  • Lumbar TDR Revision Strategies

    by Paul C. McAfee, Mark Gonz