Mahshid Nazarieh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mahshid Nazarieh has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Christian Schmied
Department of Cardiology, University Heart Center Zurich, University of Zurich
1 shared publication - David Niederseer
Department of Cardiology, Hochgebirgsklinik Davos, Medicine Campus Davos , Davos
1 shared publication - Mohammad Sadeghian
Department of Cardiology, Tehran Heart Center, Tehran University of Medical Sciences, Tehran 1411713138, Iran
1 shared publication - Reza Mazaheri
Sports Medicine Research Center, Tehran University of Medical Sciences, Tehran, IR Iran
1 shared publication
Latest Publications
- Open Access
- 8 December 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (24) , 12958
Performance of Heart Failure Patients with Severely Reduced Ejection Fraction during Cardiopulmonary Exercise Testing on Treadmill and Cycle Ergometer; Similarities and Differences
Background: Peak oxygen consumption (VO2) measured by cardiopulmonary exercise testing (CPET) is a significant predictor of mortality and future transplantation in heart failure patients with severely reduced ejection fraction (HFrEF). The present study evaluated the differences in peak VO2 and other prognostic variables between treadmill and cycle CPETs in these patients. Methods: In this cross-over study design, thirty males with severe HFrEF underwent CPET on both a treadmill and a cycle ergometer within 2–5 days apart, and important CPET parameters between two exercise test modalities were compared. Results: Peak VO2 was 23.12% higher on the treadmill than on cycle (20.55 ± 3.3 vs. 16.69 ± 3.01, p < 0.001, respectively). Minute ventilation to carbon dioxide production (VE/VCO2) slope was not different between the two CPET modes (p = 0.32). There was a strong positive correlation between the VE/VCO2 slopes during treadmill and cycle testing (r = 0.79; p < 0.001). VE/VCO2 slope was not related to peak respiratory exchange ratio (RER) in either modality (treadmill, r = 0.13, p = 0.48; cycle, r = 0.25, p = 0.17). The RER level was significantly higher on the cycle ergometer (p < 0.001). Conclusion: Peak VO2 is higher on treadmill than on cycle ergometer in severe HFrEF patients. In addition, VE/VCO2 slope is not a modality dependent parameter and is not related to the patients’ effort during CPET.
- 8 December 2021
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 18 (24) , 12958
Open AccessPerformance of Heart Failure Patients with Severely Reduced Ejection Fraction during Cardiopulmonary Exercise Testing on Treadmill and Cycle Ergometer; Similarities and Differences
Background: Peak oxygen consumption (VO2) measured by cardiopulmonary exercise testing (CPET) is a significant predictor of mortality and future transplantation in heart failure patients with severely reduced ejection fraction (HFrEF). The present study evaluated the differences in peak VO2 and other prognostic variables between treadmill and cycle CPETs in these patients. Methods: In this cross-over study design, thirty males with severe HFrEF underwent CPET on both a treadmill and a cycle ergometer within 2–5 days apart, and important CPET parameters between two exercise test modalities were compared. Results: Peak VO2 was 23.12% higher on the treadmill than on cycle (20.55 ± 3.3 vs. 16.69 ± 3.01, p < 0.001, respectively). Minute ventilation to carbon dioxide production (VE/VCO2) slope was not different between the two CPET modes (p = 0.32). There was a strong positive correlation between the VE/VCO2 slopes during treadmill and cycle testing (r = 0.79; p < 0.001). VE/VCO2 slope was not related to peak respiratory exchange ratio (RER) in either modality (treadmill, r = 0.13, p = 0.48; cycle, r = 0.25, p = 0.17). The RER level was significantly higher on the cycle ergometer (p < 0.001). Conclusion: Peak VO2 is higher on treadmill than on cycle ergometer in severe HFrEF patients. In addition, VE/VCO2 slope is not a modality dependent parameter and is not related to the patients’ effort during CPET.