Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Cuneyt Yilmaz has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Real Time Discrete Control Algorithm for Gimbal System Design in Mini Unmanned Aerial Vehicles

    by Ali Ihsan Tas, Mehmet Iscan, Ali Burak Ozden, Emre Cinar, Berkem Vural, Cuneyt Yilmaz

    Nowadays, gimbal systems have been a very critical role to obtain some important information related to live images photos and target detection in unmanned aerial vehicles. The most basic performance criterion of gimbal systems depends on its stabilization in which the desired reference tracking must be accomplished by designing complex controller structure. For this purpose, a discrete controller design is presented to provide reduced cost, high-performance, 3-axis gimbal systems in real-time operation. Firstly, the mathematical model of the system was obtained and 3D – computer aided design was made in order to calculate the system parameters like inertia, damping factor, etc. After that forward and inverse kinematic equations for the gimbal system were obtained in order to calculate the reference degree in each axis. The discrete controller was derived from energy-based computed torque proportional controller which was based on the Lyapunov Stability Theorem in discrete notation. The reference tracking results at 10 milliseconds sampling time are as follows; 0 overshoot for 3 axes with lack of steady-state errors, and the time constants are 0.1575, 0.1610, and 0.27 second which are acceptable for roll, pitch, and yaw axes, respectively. In addition, the discrete-time performance of the proposed controller was compared with a PID controller designed in continuous time, and it was shown that the continuous-time design did not work efficiently as well as discrete time one.

  • Modeling and Simulation of an Assistive Exoskeleton Leg System With Knee Osteoarthritis and Quadriceps Weakness

    by Mehmet Iscan, Cuneyt Yilmaz, Berkem Vural, Huseyin Eken

    The most common human locomotion problems such as quadriceps weakness, knee osteoarthritis can be healed up by using exoskeleton mechanisms with proper control systems. However, these kinds of abnormalities cannot be easily modeled in terms of engineering perspectives due to a lack of adequate data or unknown dynamics. Also, nature always seeks minimum energy as well as biology, which means that the unknown dynamics can be built by using this phenomenon. In this study, a new system dynamic model had been involved in designing a simple single-legged exoskeleton robot mechanism and its control system to assist partially disabled individuals to improve their quality of locomotion. To determine the specific features of the human gait disorders to interpret their nature in the computer-aided simulation environment, knee osteoarthritis, and quadriceps weakness, which are the common types of such problems, have been chosen as the main interests for this study. By using the lower limb model with anthropometric data, the simulations of disorders have been realized on matlabsimscape environment, which enables us to model the entire exoskeleton system with the three-dimensional parts of the human body. A model of a leg with the disorder was able to be obtained with the utilization of feedback linearization, which is one of the examples of minimum principles in the control theory. A proper gait cycle is achieved with the exoskeleton application and separately for the leg, with approximately 10 deg deviation from the natural property in knee flexion. Finally, it can be seen that the system conversion into such problematic cases with or without an exoskeleton system is accomplished.


  • A Novel QT-Interval Analysis Method Based on Continuous Wavelet Transform and Philips Algorithm

    by Mehmet İşCan, Abdurrahman Yilmaz, Berkem Vural, Cüneyt Yilmaz, Volkan Tuzcu

    QT surveillance is the most vital appliance to detect the possibility of sudden death sourced by using pro-arrhythmic drugs treating abnormal conditions in the heart. The repolarization of ventricles makes QT interval surveillance difficult since noisy conditions and individual cardiac situations. Besides, an automated QT algorithm is crucial due to a manual QT measurement with some disadvantages such as fatigue condition in reading long records. In this study, a fully novel automated method combining Continuous Wavelet Transform and Philips method was established to perform QT interval analysis. Electrocardiogram recordings were obtained from PhyisoNet database marked by manual and standard automated methods. The proposed algorithm had scores of 15.46 and 11.87 millisecond mean error with 11.85 and 9.91 millisecond standard deviation in terms of gold and silver standards, respectively. Also, the entire QT database was utilized in order to test the algorithm performance with the score of 12.89 and 9.76 millisecond mean and standard deviation errors, respectively. The present algorithm performance had scores of −0.21 ± 7.81 at golden standard, and −4.10 ± 18.21 millisecond error for the whole QT database tests, respectively. The proposed algorithm is attained to more stable and robust results with a higher performance than the previous comparable studies.


  • Open Access

    Design and Validation of a Camera-Based Safety System for Fenceless Robotic Work Cells

    by Merdan Ozkahraman, Cuneyt Yilmaz, Haydar Livatyali

    A two-dimensional (2-D) camera system with a real-time image processing-based safety technology is a cost-effective alternative that needs optimization of the cell layout, the number of cameras, and the camera’s locations and orientations. A design optimization study was performed using the multi-criteria linear fractional programming method and considering the number of cameras, the resolution, as well as camera positions and orientations. A table-top experimental setup was designed and built to test the effectiveness of the optimized design using two cameras. The designs at optimal and nonoptimal parameters were compared using a deep learning algorithm, ResNet-152. To eliminate blind spots, a simple but novel 2-D image merging technique was proposed as an alternative to commonly employed stereo imaging methods. Verification experiments were conducted by using two camera resolutions with two graphic processors under varying illuminance. It was validated that high-speed entrances to the safety system were detected reliably and with a 0.1 s response time. Moreover, the system was proven to work effectively at a minimum illuminance of 120 lux, while commercial systems cannot be operated under 400 lux. After determining the most appropriate 2-D camera type, positions, and angles within the international standards, the most cost-effective solution set with a performance-to-price ratio up to 15 times higher than high-cost 3-D camera systems was proposed and validated.


  • Ayak bileği ve diz rehabilitasyonunda pasif egzersizler için stewart platform tabanlı robot tasarımı ve kontrolü

    by Merve Teke Budakli, Cüneyt Yilmaz

    Günümüzde robotların sanayi ve günlük yaşamda kullanım alanları artmakta ve bununla birlikte uygulamaların robotlar tarafından yerine getirilmesi için farklı robot tasarımları geliştirilmektedir. Paralel robotlar, kapalı zincir kinematik yapısından dolayı kısıtlanmış çalışma uzayına sahiptir. Bunun yanı sıra bu kinematik yapı robota yüksek konum hassasiyeti ve rijitlik kazandırmaktadır. Rehabilitasyon robotlarında; rijit yapı ve hassas pozisyonlama en önemli unsurlardır bu nedenle paralel robotlar rehabilitasyon uygulamalarına uygundur. Bununla birlikte, paralel robotların sınırlı çalışma uzayı eklem hareket açıklığında kısıt oluşturmaktadır. Bu çalışmada; Stewart Platform yapısına, 7’inci lineer aktüatör ve buna bağlı bir mekanizma ilave edilerek, çalışma uzayı genişletilerek daha fazla alt uzuv eklemine rehabilitasyon yapılmasını sağlayan yeni bir robot tasarlanmıştır. Mekanik tasarım, elektronik donanım, Newton-Raphson sayısal yöntemiyle ileri kinematik ve vektörel ters kinematik hesaplamalarıyla oluşturulan matematiksel alt yapısı ve PID pozisyon kontrolü birleştirilerek rehabilitasyon robotu tasarlanmıştır. İnsan bacağı üzerinde yapılan deneylerle robotun, ayak bileği ve diz eklem hareket açıklıklarını gerçekleştirebilme ve pozisyonlama sonuçları değerlendirilmiş ve literatürle karşılaştırılmıştır. Deneysel ölçümlere göre yörünge takibinde zaman gecikmesi 0,5 saniyenin altında ve azami açı sapması 1,2° elde edilmiştir.