P. Suresh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
P. Suresh has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- G. Yuvaraj
Department of Mechanical Engineering, SNS College of Technology, Coimbatore, India
1 shared publication - Jayashri Narayanan Nair
Department of Mechanical Engineering, VNR Vignana Jyothi Institute of Engineering and Technology Nizampet, Hyderabad, India
1 shared publication - K. Venkatesh Raja
Department of Mechanical Engineering, Sona College of Technology, Salem, India
1 shared publication - Kandasamy Murugesan
Department of Mechatronics Engineering, Kumaraguru College of Technology, Coimbatore, India
1 shared publication - M. Prabu
K.S.R College of Engineering, Namakkal, India
1 shared publication - R. J. Golden Renjith Nimal
Department of Mechanical Engineering, Jai Shriram Engineering College, Tirupur, India
1 shared publication
Latest Publications
- 1 September 2026
- Published by Springer Nature in Cellulose
- Vol. 33 (13) , 7923-7939
Mechanical characterization and failure analysis of flax fiber reinforced epoxy composites under static and dynamic loading
- 1 September 2026
- Published by Springer Nature in Cellulose
- Vol. 33 (13) , 7923-7939
Mechanical characterization and failure analysis of flax fiber reinforced epoxy composites under static and dynamic loading
- 20 April 2026
- Published by Springer Nature in Polymer Bulletin
- Vol. 83 (7) , 369
Sustainable material development and synergistic effects of epoxy composites reinforced with areca fibers and eggshell hydroxyapatite
- 20 April 2026
- Published by Springer Nature in Polymer Bulletin
- Vol. 83 (7) , 369
Sustainable material development and synergistic effects of epoxy composites reinforced with areca fibers and eggshell hydroxyapatite
- 27 February 2024
- Published by Springer Nature in Polymer Bulletin
- Vol. 81 (11) , 9961-9976
Effect of graphene/silicon dioxide fillers addition on mechanical and thermal stability of epoxy glass fibre composite
- 27 February 2024
- Published by Springer Nature in Polymer Bulletin
- Vol. 81 (11) , 9961-9976
Effect of graphene/silicon dioxide fillers addition on mechanical and thermal stability of epoxy glass fibre composite
- Open Access
- 1 November 2021
- Published by Walter de Gruyter GmbH in Strojnícky časopis - Journal of Mechanical Engineering
- Vol. 71 (2) , 305-316
Assessment on the Optimum Performance of a Novel 3 Axes Micro EDM Developed for Commercial Applications
A low cost three axes commercial microEDM machine has been developed indigenously in order to implement precision micromachining. The developed microEDM consists of various components such as machining chamber, X-Y table, tool feed and tool holder assembly, dielectric circulation system, power supply and automatic driving devices to control the spark gap distance. The setup is capable of performing the 8µm movement in Z-axis.The developed 3 axes machine and the commercial available machine are investigated with the most important process parameters such as Current, Pulse on time and Pulse off time in order to study the Material Removal Rate (MRR) and Tool Wear Rate (TWR). The material chosen for the current research is Stainless Steel 316L, which has high corrosion resistance and the electrode was tungsten 300µm. In most of the experiments, the developed machine has performed with 6.52% higher MRR and 26.10% Lower TWR. This is due to the effective spark gap circuit developed with the use of hall current sensor.The mathematical model of MRR and TWR are obtained by correlating the process parameter using Response Surface Methodology (RSM).The chosen objectives are contradictory in nature, we employ a non-dominated Genetic algorithm to find the optimal process parameters. The developed 3 axes microEDM has yield a 10.14% and 33.12% better performance on optimum maximum MRR and minimum TWR respectively when compared to the commercial machine.
- 1 November 2021
- Published by Walter de Gruyter GmbH in Strojnícky časopis - Journal of Mechanical Engineering
- Vol. 71 (2) , 305-316
Open AccessAssessment on the Optimum Performance of a Novel 3 Axes Micro EDM Developed for Commercial Applications
A low cost three axes commercial microEDM machine has been developed indigenously in order to implement precision micromachining. The developed microEDM consists of various components such as machining chamber, X-Y table, tool feed and tool holder assembly, dielectric circulation system, power supply and automatic driving devices to control the spark gap distance. The setup is capable of performing the 8µm movement in Z-axis.The developed 3 axes machine and the commercial available machine are investigated with the most important process parameters such as Current, Pulse on time and Pulse off time in order to study the Material Removal Rate (MRR) and Tool Wear Rate (TWR). The material chosen for the current research is Stainless Steel 316L, which has high corrosion resistance and the electrode was tungsten 300µm. In most of the experiments, the developed machine has performed with 6.52% higher MRR and 26.10% Lower TWR. This is due to the effective spark gap circuit developed with the use of hall current sensor.The mathematical model of MRR and TWR are obtained by correlating the process parameter using Response Surface Methodology (RSM).The chosen objectives are contradictory in nature, we employ a non-dominated Genetic algorithm to find the optimal process parameters. The developed 3 axes microEDM has yield a 10.14% and 33.12% better performance on optimum maximum MRR and minimum TWR respectively when compared to the commercial machine.