Imam Akbar
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Imam Akbar has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Hasan Basri
Universitas Sriwijaya
6 shared publications - Muhammad Imam Ammarullah
Department of Mechanical and Aerospace Engineering College of Engineering United Arab Emirates University Al Ain United Arab Emirates
6 shared publications - Akbar Teguh Prakoso
Sriwijaya University
4 shared publications - Ardiyansyah Syahrom
Universiti Teknologi Malaysia
4 shared publications - Dendy Adanta
Universitas Sriwijaya
2 shared publications - Tunku Kamarul
Universiti Malaya
2 shared publications
Latest Publications
- 22 September 2026
- Published by Taylor & Francis in Philosophical Magazine
- p. 1-25
Tailoring degradation of PLA/Mg/PEG bone scaffolds through triply periodic minimal surface (TPMS) diamond architectures (Uniform vs graded) using fused filament fabrication (FFF) additive manufacturing
ANOVAAnalysis of varianceDCMDichloromethaneFFFFused filament fabricationFGSFunctionally graded scaffoldFTIRFourier transform infraredMgMagnesiumPBSPhosphate-buffered salinePEGPolyethylene glycolPLA...
- 22 September 2026
- Published by Taylor & Francis in Philosophical Magazine
- p. 1-25
Tailoring degradation of PLA/Mg/PEG bone scaffolds through triply periodic minimal surface (TPMS) diamond architectures (Uniform vs graded) using fused filament fabrication (FFF) additive manufacturing
ANOVAAnalysis of varianceDCMDichloromethaneFFFFused filament fabricationFGSFunctionally graded scaffoldFTIRFourier transform infraredMgMagnesiumPBSPhosphate-buffered salinePEGPolyethylene glycolPLA...
- 20 November 2025
- Published by Elsevier in Bioprinting
- Vol. 52
Optimization of process parameters for fabricating PLA/Mg/HA biocomposite filaments using the Taguchi method for biomedical applications
- 20 November 2025
- Published by Elsevier in Bioprinting
- Vol. 52
Optimization of process parameters for fabricating PLA/Mg/HA biocomposite filaments using the Taguchi method for biomedical applications
- Open Access
- 7 April 2025
- Published by Elsevier in Results in Chemistry
- Vol. 15
Optimized pyrolysis of household plastic waste in Indonesia for oil production: Hydrocarbon profiling, fuel alternative, and potential biomedical application
- 7 April 2025
- Published by Elsevier in Results in Chemistry
- Vol. 15
Open AccessOptimized pyrolysis of household plastic waste in Indonesia for oil production: Hydrocarbon profiling, fuel alternative, and potential biomedical application
- Open Access
- 8 January 2025
- Published by Taylor & Francis in Advanced Manufacturing: Polymer & Composites Science
- Vol. 11 (1)
Optimization of PLA/Mg/PEG biocomposite filaments for 3D-printed bone scaffolds using response surface methodology (RSM)
- 8 January 2025
- Published by Taylor & Francis in Advanced Manufacturing: Polymer & Composites Science
- Vol. 11 (1)
Open AccessOptimization of PLA/Mg/PEG biocomposite filaments for 3D-printed bone scaffolds using response surface methodology (RSM)
- Open Access
- 1 February 2023
- Published by MDPI AG in Biomedicines
- Vol. 11 (2) , 427
The Effect of Tortuosity on Permeability of Porous Scaffold
In designing porous scaffolds, permeability is essential to consider as a function of cell migration and bone tissue regeneration. Good permeability has been achieved by mimicking the complexity of natural cancellous bone. In this study, a porous scaffold was developed according to the morphological indices of cancellous bone (porosity, specific surface area, thickness, and tortuosity). The computational fluid dynamics method analyzes the fluid flow through the scaffold. The permeability values of natural cancellous bone and three types of scaffolds (cubic, octahedron pillar, and Schoen’s gyroid) were compared. The results showed that the permeability of the Negative Schwarz Primitive (NSP) scaffold model was similar to that of natural cancellous bone, which was in the range of 2.0 × 10−11 m2 to 4.0 × 10−10 m2. In addition, it was observed that the tortuosity parameter significantly affected the scaffold’s permeability and shear stress values. The tortuosity value of the NSP scaffold was in the range of 1.5–2.8. Therefore, tortuosity can be manipulated by changing the curvature of the surface scaffold radius to obtain a superior bone tissue engineering construction supporting cell migration and tissue regeneration. This parameter should be considered when making new scaffolds, such as our NSP. Such efforts will produce a scaffold architecturally and functionally close to the natural cancellous bone, as demonstrated in this study.
- 1 February 2023
- Published by MDPI AG in Biomedicines
- Vol. 11 (2) , 427
Open AccessThe Effect of Tortuosity on Permeability of Porous Scaffold
In designing porous scaffolds, permeability is essential to consider as a function of cell migration and bone tissue regeneration. Good permeability has been achieved by mimicking the complexity of natural cancellous bone. In this study, a porous scaffold was developed according to the morphological indices of cancellous bone (porosity, specific surface area, thickness, and tortuosity). The computational fluid dynamics method analyzes the fluid flow through the scaffold. The permeability values of natural cancellous bone and three types of scaffolds (cubic, octahedron pillar, and Schoen’s gyroid) were compared. The results showed that the permeability of the Negative Schwarz Primitive (NSP) scaffold model was similar to that of natural cancellous bone, which was in the range of 2.0 × 10−11 m2 to 4.0 × 10−10 m2. In addition, it was observed that the tortuosity parameter significantly affected the scaffold’s permeability and shear stress values. The tortuosity value of the NSP scaffold was in the range of 1.5–2.8. Therefore, tortuosity can be manipulated by changing the curvature of the surface scaffold radius to obtain a superior bone tissue engineering construction supporting cell migration and tissue regeneration. This parameter should be considered when making new scaffolds, such as our NSP. Such efforts will produce a scaffold architecturally and functionally close to the natural cancellous bone, as demonstrated in this study.
- Open Access
- 3 January 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (1) , 823
Level of Activity Changes Increases the Fatigue Life of the Porous Magnesium Scaffold, as Observed in Dynamic Immersion Tests, over Time
In the present study, the effects of human physiological activity levels on the fatigue life of a porous magnesium scaffold have been investigated. First, the dynamic immersion and biomechanical testing are carried out on a porous magnesium scaffold to simulate the physiological conditions. Then, a numerical data analysis and computer simulations predict the implant failure values. A 3D CAD bone scaffold model was used to predict the implant fatigue, based on the micro-tomographic images. This study uses a simulation of solid mechanics and fatigue, based on daily physiological activities, which include walking, running, and climbing stairs, with strains reaching 1000–3500 µm/mm. The porous magnesium scaffold with a porosity of 41% was put through immersion tests for 24, 48, and 72 h in a typical simulated body fluid. Longer immersion times resulted in increased fatigue, with cycles of failure (Nf) observed to decrease from 4.508 × 1022 to 2.286 × 1011 (1.9 × 1011 fold decrease) after 72 hours of immersion with a loading rate of 1000 µm/mm. Activities played an essential role in the rate of implant fatigue, such as demonstrated by the 1.1 × 105 fold increase in the Nf of walking versus stair climbing at 7.603 × 1011 versus 6.858 × 105, respectively. The dynamic immersion tests could establish data on activity levels when an implant fails over time. This information could provide a basis for more robust future implant designs.
- 3 January 2023
- Published by MDPI AG in Sustainability
- Vol. 15 (1) , 823
Open AccessLevel of Activity Changes Increases the Fatigue Life of the Porous Magnesium Scaffold, as Observed in Dynamic Immersion Tests, over Time
In the present study, the effects of human physiological activity levels on the fatigue life of a porous magnesium scaffold have been investigated. First, the dynamic immersion and biomechanical testing are carried out on a porous magnesium scaffold to simulate the physiological conditions. Then, a numerical data analysis and computer simulations predict the implant failure values. A 3D CAD bone scaffold model was used to predict the implant fatigue, based on the micro-tomographic images. This study uses a simulation of solid mechanics and fatigue, based on daily physiological activities, which include walking, running, and climbing stairs, with strains reaching 1000–3500 µm/mm. The porous magnesium scaffold with a porosity of 41% was put through immersion tests for 24, 48, and 72 h in a typical simulated body fluid. Longer immersion times resulted in increased fatigue, with cycles of failure (Nf) observed to decrease from 4.508 × 1022 to 2.286 × 1011 (1.9 × 1011 fold decrease) after 72 hours of immersion with a loading rate of 1000 µm/mm. Activities played an essential role in the rate of implant fatigue, such as demonstrated by the 1.1 × 105 fold increase in the Nf of walking versus stair climbing at 7.603 × 1011 versus 6.858 × 105, respectively. The dynamic immersion tests could establish data on activity levels when an implant fails over time. This information could provide a basis for more robust future implant designs.
- Top Cited PapersOpen Access
Tresca Stress Simulation of Metal-on-Metal Total Hip Arthroplasty during Normal Walking Activity
The selection of biomaterials for bearing in total hip arthroplasty is very important to avoid various risks of primary postoperative failure for patients. The current investigation attempts to analyze the Tresca stress of metal-on-metal bearings with three different materials, namely, cobalt chromium molybdenum (CoCrMo), stainless steel 316L (SS 316L), and titanium alloy (Ti6Al4V). We used computational simulations using a 2D axisymmetric finite element model to predict Tresca stresses under physiological conditions of the human hip joint during normal walking. The simulation results show that Ti6Al4V-on-Ti6Al4V has the best performance to reduce Tresca stress by 45.76% and 39.15%, respectively, compared to CoCrMo-on-CoCrMo and SS 316L-on-SS 316L.
Top Cited PapersOpen AccessTresca Stress Simulation of Metal-on-Metal Total Hip Arthroplasty during Normal Walking Activity
The selection of biomaterials for bearing in total hip arthroplasty is very important to avoid various risks of primary postoperative failure for patients. The current investigation attempts to analyze the Tresca stress of metal-on-metal bearings with three different materials, namely, cobalt chromium molybdenum (CoCrMo), stainless steel 316L (SS 316L), and titanium alloy (Ti6Al4V). We used computational simulations using a 2D axisymmetric finite element model to predict Tresca stresses under physiological conditions of the human hip joint during normal walking. The simulation results show that Ti6Al4V-on-Ti6Al4V has the best performance to reduce Tresca stress by 45.76% and 39.15%, respectively, compared to CoCrMo-on-CoCrMo and SS 316L-on-SS 316L.