SMSantanu Mitra

Santanu Mitra

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Santanu Mitra has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A multimodal multi-label deep learning framework with temporal attention for detection of upper-limb motor activities for prosthetic control

    by Deepak Chandra Joshi, Rakesh Chandra Joshi, Pankaj Kumar, Santanu Mitra

    Accurate detection of simultaneous grip and elbow flexion is critical for advanced rehabilitation monitoring, intuitive prosthetic control and human-machine interaction. Existing approaches, particularly those relying solely on surface electromyography (sEMG), often struggle to capture overlapping muscle activations and the biomechanical context of dynamic upper-limb movements. This study proposes a multimodal, multi-label deep learning framework integrating sEMG, pressure distribution and inertial sensing for concurrent detection of grip and elbow flexion. Signals were acquired from three sEMG channels, four pressure sensors embedded in a Wii Balance Board and a nine-axis inertial measurement unit. All modalities were synchronized, standardized and segmented into fixed-length windows of 100 samples. A customized convolutional neural network and bidirectional long-short-term memory architecture with temporal attention was employed to model spatial-temporal dependencies across sensor streams. Multi-label sigmoid outputs enabled simultaneous prediction of both movements. Evaluation was conducted using subject-level cross-validation with file-level train-test splitting. The proposed framework achieved a window-level macro F1-score of 0.9573 with a Hamming loss of 0.0674 and file-level aggregation yielded a macro F1-score of 0.9783. Feature analysis indicated dominant contributions from inertial and pressure signals with sEMG providing complementary activation information. The proposed multimodal sensor fusion enables robust multi-label detection with attention-guided temporal weighting of complex upper-limb movements. This framework helps address key limitations of single-modality EMG systems and supports scalable real-time rehabilitation and assistive applications.

  • Optimization of Savonius rotor array through a hybrid CFD-ANN-PSO method

    by Sunil Kumar, Nishant Mishra, Santanu Mitra, Debi Prasad Mishra, Visakh Vaikuntanathan


  • Evolution of maneuverability for biomimetic underwater soft robots

    by Rakesh Rayapureddi, Santanu Mitra

    The success of biomimetic unmanned underwater vehicle (UUV) missions depends on their turning performance in confined regions without causing unprecedented disturbances to their surroundings. In this paper, we present an efficient computational model for fully resolved simulations of maneuverability and agility for complex deforming swimmers, and visualize their precise hydrodynamics with quantification of vortex formation and shedding processes during turning motion. We implemented a new momentum redistribution method to couple three-dimensional fluid–structure interactions within the OpenFOAM platform. We demonstrate the accuracy of our model by considering challenging benchmark simulations of the maneuverability of batoids and validated them with particle image velocimetry observations of natural species. Furthermore, we explore the development of batoid-inspired UUVs utilizing efficient turning maneuver strategies. We present the effects of morphological features, such as extended fin span, tail actuation, and hydrofoil shaping, on turning parameters and swimming performance. Quantitative results demonstrate improved hydrodynamic performance in the hydrofoil-shaped model, with a peak forward velocity of 1.5 BL·s−1 and a turning rate of 26.25°/s. The solver demonstrated robust numerical stability, achieving periodic force convergence within four cycles and efficiently capturing full six degrees of freedom motion under complex, unsteady flow conditions. This study enables the accurate and precise development of locomotor kinematics for biomimetic underwater vehicles, particularly in scenarios involving multiple deforming bodies, such as swarm behavior in batoids.


  • Bioinspired curved blade for darrieus vertical axis wind turbine: A novel conceptual design and experimental investigation

    by Punit Prakash, Praveen Laws, Nishant Mishra, Santanu Mitra

    The present study proposes a novel bio-inspired blade design to improve the efficiency of a VAWT model. The design model features a curved blade that sweeps backward, same characteristics as the Bottlenose Dolphin’s flippers. The proposed model would enhances aerodynamic flow over the system and improves torque. The modified shape can cause the fluid flow to converge towards the middle of the blade due to the pressure difference caused by the modified blade profile. Three modified shapes have been studied experimentally to observe the effect of swept curved design with a forward sweep of 0.2 c , 0.6 c , and 1.0 c for these augmented models. A wind-driven performance analysis mode is performed in a subsonic wind tunnel. A maximum of 15.7% increment in torque is observed for the model having a sweep of 1.0 c , and a maximum of 15% Coefficient of performance ( C P ) is observed by Model D at tip speed ratio ( TSR , λ ) = 1.8. An increment of 12% is observed in C P between the conventional and the modified model.


  • Computational fluid dynamical analysis of a Savonius vertical axis wind rotor array

    by Sunil Kumar, Santanu Mitra, Nishant Mishra, Visakh Vaikuntanathan

    Savonius vertical axis wind turbine (VAWT) arrays are being studied for urban and semi-urban wind energy harvesting. With limited ground space in these areas, optimizing energy extraction through various array configurations is crucial. This study presents a computational fluid dynamics (CFD) analysis of a four-rotor Savonius VAWT array. Various unit array configurations, based on wake analysis of an isolated Savonius rotors, are evaluated through detailed CFD study. The parameters of interest in this study are the coefficient of power, Cpi (i= 1, 2, 3, or 4 is the rotor number) at different typical values of the tip-speed ratio, λ=ΩD/2U∞ (where Ω is the angular speed of the rotor, D is the diameter of the rotor, and U∞ is the free stream air velocity) of the constituent rotors of the unit array, rotational orientation as well as the average value of the coefficient of power, Cpa=(∑i=14Cpi)/4. It is observed that at certain configurations of the four-unit array, it is possible to have a power enhancement, Ψ=Cpa/Cp0>1 up to 1.34 (34% gain), where Cp0 is the coefficient of power of an isolated Savonius rotor at the same λ. The observed enhancement is explained using velocity and pressure fields around the unit array. Comparative analysis with previous studies highlights new approaches for designing high-performance Savonius arrays and suggests directions for CFD-based optimization of larger arrays.


  • Open Access

    AI-Enhanced Analysis to Investigate the Feasibility of EMG Signals for Prosthetic Hand Force Control Incorporating Anthropometric Measures

    by Deepak Chandra Joshi, Pankaj Kumar, Rakesh Chandra Joshi, Santanu Mitra

    Background/Objectives: The potential application of electromyography (EMG) as a method for precise force control in prosthetic devices is investigated, expanding on its traditional use in gesture detection. Variability in EMG signals among individuals is influenced by physiological factors such as muscle mass, body fat percentage, and subcutaneous fat, as well as demographic variables like age, gender, height, and weight. This study aims to evaluate how these factors impact EMG signal quality and force output. Methods: EMG data was normalized using the maximum voluntary contraction (MVC) method, recorded at 100%, 50%, and 25% of MVC with simultaneous grip force measurement. Physiological parameters, including fat percentage, subcutaneous fat, and muscle mass, were analyzed. An extreme gradient boosting algorithm was applied to model the relationship between EMG amplitude and grip force. Results: The findings demonstrated significant linear correlations, with r2 coefficients reaching up to 0.93 and 0.83 in most cases. Muscle mass and fat levels were identified as key determinants of EMG variability, with significance coefficients ranging from 0.36592 to 0.0856 for muscle mass and 0.281918 to 0.06001 for fat levels. Conclusions: These results underscore the potential of EMG to enhance force control in prosthetic limbs, particularly in tasks such as grasping, holding, and releasing objects. Incorporating body composition factors into EMG-based prediction algorithms offers a refined approach to improving the precision and functionality of prosthetic control systems for complex motor tasks.


  • Bioinspired swept-curved blade design for performance enhancement of Darrieus wind turbine

    by P. Prakash, P. Laws, S. Mitra, N. Mishra

    The present research proposes novel swept-curved bioinspired blades for Darrieus wind turbine. The design was influenced by the curved flippers of the bottle-nose dolphin. The proposed model was designed using the Solidworks software, empirically tested for power improvement, later fine-tuned adopting high fidelity numerical modeling. An in-depth analysis comparing the traditional H-bladed turbine with the new-bladed design was performed using OpenFOAM. Further, an elaborate experimental observations on the proposed design suggest that the model with 0.6c forward sweep outperformed the rest. The efficiency of the curved blade was notably enhanced by 14.41%, in contrast to the conventional model, and the numerical analysis endorses this observation. The modified turbine blades have the maximum wind streamlines that converge toward the center of the blade's trailing edge due to the lateral shift, and the resulting convergence reduces blade tip losses. The modified blade models demonstrated improved angular acceleration at a given wind speed, indicating enhanced efficiency and superior self-starting capabilities. Notably, these improvements were evident even at a lower wind speed of 4.2 m/s compared to the traditional H-model.


  • A real-time experimental investigation of thin cambered tubercle blades for performance improvement of Darrieus vertical axis wind turbine

    by Punit Prakash, Leela Krishna Pendyala, Rajiv Chandra Teladevalapalli, Santanu Mitra

    Darrieus vertical axis wind turbines (VAWT) have various shapes associated with them; H-shaped devices are amongst the most common designs being used. To enhance the performance of these devices, nature-inspired tubercle shapes have been implemented to these H-shaped blade profiles. Hump-back whale flippers inspire these tubercles. They have a sinusoidal pattern on the flippers, which has been stated to help these gigantic beings to have sharp turns. The present study has implemented this modification to the H-bladed profile. A NACA4412 profile has been selected for the present study. An experimental analysis has been performed with three-bladed turbines with modified shape in a subsonic wind tunnel having a straight cambered and cambered tubercle. The tubercle model outperforms the straight-cambered models. The analysis was performed at wind speeds of 6 to 7 m/s to mimic the natural wind flow operating conditions. Real-time torque data were plotted using a rotary torque sensor for 100 sec of operation. The tubercle model showed a 16.66% increase in increment in the torque value at 7 m/s.


  • Open Access

    A Brief Overview of Bioinspired Robust Hydrogel Based Shape Morphing Functional Structure for Biomedical Soft Robotics

    by Rohit Goyal, Santanu Mitra

    Biomimetic and soft robotics research has been inspired by many biological organisms focusing on soft structural composites reinforced by stiff constituents. In the case of synthetic soft structural materials, hydrogels are very similar to the biological soft tissues/organs, owing to their “wet and soft” properties, their elastic performance, biodegradability, and biocompatibility. However, the current scope of hydrogel applications is usually hampered by their feeble mechanical properties. Although significant progress has been made in developing intense, challenging, and stretchable hydrogels, it is still challenging to realize the optimal magnitude of physical and mechanical properties altogether in synthetic hydrogels. This review briefly focuses on the hydrogel fibrous shape-morphing composite structure and its functionalities. The nature-inspired, fiber-reinforced soft hydrogel shape-morphing functional composite structure delivers them a cartilage-like anisotropic behavior. They could have broad potential applications in various areas, including tissue engineering, soft robotics, stretchable and bio-integrated electronics, microfluidics, and biomedical devices.