MKMonika Kutyła

Monika Kutyła

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Monika Kutyła has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Practical Digital Twins Application to High Energy Systems: Thermal Protection for Multi-Detector

    by Andrzej Wojtulewicz, Paweł D. Domański, Maciej Czarnynoga, Monika Kutyła, Maciej Ławryńczuk, Robert Nebeluk, Sebastian Plamowski, Krystian Rosłon, Krzysztof Zarzycki

    The digital twins concept brings a new perspective into the system design and maintenance practice. As any industrial process can be accurately simulated, its digital replica can be utilized to design a control system structure, evaluate its efficacy and investigate the properties of the real system and possible issues. Based on such an analysis, ideas for improvement may be formulated. This article reports the formulation of a digital twin system developed for a Thermal System (TS) maintaining proper thermal conditions for the operation of the Silicon Tracking Detectors (STDs) utilized for high-energy physics experiments. A thermal system digital twin is built for a full-scale target installation, which is right now during the construction phase. The emphasis is put on a proper control system design using the thermal system digital twins.


  • Open Access

    Bendductor—Transformer Steel Magnetomechanical Force Sensor

    by Przemysław Grenda, Monika Kutyła, Michał Nowicki, Tomasz Charubin

    In this paper, the design and investigation of an innovative force sensor, based on the Villari effect, is presented. The sensor was built from electrical steel, in a pressductor pattern, but working in bending load mode. The results of the experimental research allowed for the evaluation of transducer’s performance, mitigation of measurement hysteresis, and optimization of its functional parameters. Several issues have been examined, among them the selection of supply and measured signals, the measured values’ impact on measurement hysteresis, harmonic analysis, and the selection of proper current waveforms and frequencies. The proposed sensor is robust, made from inexpensive materials, and has high sensitivity, as compared to other magnetoelastic sensors. It has much higher stress sensitivity than other magnetoelastic sensors due to deformation mode. Based on the tests, its measuring range can be defined as 0.5–5 N with a near-linear characteristic, SNR of 46 dB, and 0.11 N uncertainty.