Éva Ilona Lakatos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Éva Ilona Lakatos has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Brigitta Krisztina Tóth
Department of Structural Mechanics, Budapest University of Technology and Economics, Műegyetem rkp. 3., Budapest, H-1111, Hungary
2 shared publications - Róbert Károly Németh
Department of Structural Mechanics, Faculty of Civil Engineering, Budapest University of Technology and Economics, Műegyetem rkp. 3., Budapest, H-1111, Hungary
2 shared publications - András Czétényi
Department of Mechatronics, Optics and Engineering Informatics, Faculty of Mechanical Engineering, Budapest University of Technology and Economics, HU-1111 Budapest, Hungary
1 shared publication - Boyko Gueorguiev
AO Research Institute Davos, Davos, Switzerland
1 shared publication - Danica Matusovits
Department of Oral Surgery, Faculty of Dentistry, University of Szeged, Tisza Lajos krt. 64–66., 6720 Szeged, Hungary
1 shared publication - Haydar Slyteen
Department of Structural Mechanics, Faculty of Civil Engineering, University of Technology and Economics, Budapest, Műegyetem rkp. 3., 1111 Budapest, Hungary
1 shared publication
Latest Publications
- Open Access
- 13 January 2026
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 176, 107345
Modeling the mechanical anisotropy in the trabecular bone with the measurement and consideration of the structural anisotropy
- 13 January 2026
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 176, 107345
Open AccessModeling the mechanical anisotropy in the trabecular bone with the measurement and consideration of the structural anisotropy
- Open Access
Biomechanical Behavior of Injected Cement Spacers versus Traditional Cages in Low-Density Lumbar Spine under Compression Loading
Background and Objectives: Osteoporosis renders the use of traditional interbody cages potentially dangerous given the high risk of damage in the bone–implant interface. Instead, injected cement spacers can be applied as interbody devices; however, this technique has been mainly used in cervical spine surgery. This study aimed at investigating the biomechanical behavior of cement spacers versus traditional cages in lumbar spine surgery. Materials and Methods: Destructive monotonic axial compression testing was performed on 20 human cadaveric low-density lumbar segments from elderly donors (14 f/6 m, 70.3 ± 12.0 y) treated with either injected cement spacers (n = 10) or traditional cages (n = 10) without posterior instrumentation. Stiffness, failure load and displacement were compared. The effects of bone density, vertebral geometry and spacer contact area were evaluated. Results: Cement spacers demonstrated higher stiffness, significantly smaller displacement (p < 0.001) and a similar failure load compared to traditional cages. In the cage group, stiffness and failure load depended strongly on bone density and vertebral height, whereas failure displacement depended on vertebral anterior height. No such correlations were identified with cement spacers. Conclusions: Cement spacers used in lumbar interbody stabilization provided similar compression strength, significantly smaller failure displacement and a stiffer construct than traditional cages that provided benefits mainly for large and strong vertebrae. Cement stabilization was less sensitive to density and could be more beneficial also for segments with smaller and less dense vertebrae. In contrast to the injection of cement spacers, the optimal insertion of cages into the irregular intervertebral space is challenging and risks damaging bone. Further studies are required to corroborate these findings and the treatment selection thresholds.
Open AccessBiomechanical Behavior of Injected Cement Spacers versus Traditional Cages in Low-Density Lumbar Spine under Compression Loading
Background and Objectives: Osteoporosis renders the use of traditional interbody cages potentially dangerous given the high risk of damage in the bone–implant interface. Instead, injected cement spacers can be applied as interbody devices; however, this technique has been mainly used in cervical spine surgery. This study aimed at investigating the biomechanical behavior of cement spacers versus traditional cages in lumbar spine surgery. Materials and Methods: Destructive monotonic axial compression testing was performed on 20 human cadaveric low-density lumbar segments from elderly donors (14 f/6 m, 70.3 ± 12.0 y) treated with either injected cement spacers (n = 10) or traditional cages (n = 10) without posterior instrumentation. Stiffness, failure load and displacement were compared. The effects of bone density, vertebral geometry and spacer contact area were evaluated. Results: Cement spacers demonstrated higher stiffness, significantly smaller displacement (p < 0.001) and a similar failure load compared to traditional cages. In the cage group, stiffness and failure load depended strongly on bone density and vertebral height, whereas failure displacement depended on vertebral anterior height. No such correlations were identified with cement spacers. Conclusions: Cement spacers used in lumbar interbody stabilization provided similar compression strength, significantly smaller failure displacement and a stiffer construct than traditional cages that provided benefits mainly for large and strong vertebrae. Cement stabilization was less sensitive to density and could be more beneficial also for segments with smaller and less dense vertebrae. In contrast to the injection of cement spacers, the optimal insertion of cages into the irregular intervertebral space is challenging and risks damaging bone. Further studies are required to corroborate these findings and the treatment selection thresholds.
- Open Access
- 20 March 2024
- Published by Elsevier in Mechanics of Materials
- Vol. 192
Three-dimensional elastic properties of open-cell porous structures: Analytic and finite element modelling
- 20 March 2024
- Published by Elsevier in Mechanics of Materials
- Vol. 192
Open AccessThree-dimensional elastic properties of open-cell porous structures: Analytic and finite element modelling
- Open Access
- 7 November 2023
- Published by MDPI AG in Dentistry Journal
- Vol. 11 (11) , 261
Biomechanical Effects of Different Load Cases with an Implant-Supported Full Bridge on Four Implants in an Edentulous Mandible: A Three-Dimensional Finite Element Analysis (3D-FEA)
The long-term success and predictability of implant-supported restorations largely depends on the biomechanical forces (stresses) acting on implants and the surrounding alveolar bone in the mandible. The aim of our study was to investigate the biomechanical behavior of an edentulous mandible with an implant-supported full bridge on four implants under simulated masticatory forces, in the context of different loading schemes, using a three-dimensional finite element analysis (3D-FEA). A patient-specific 3D finite element model was constructed using pre- and post-implantation computer tomography (CT) images of a patient undergoing implant treatment. Simplified masticatory forces set at 300 N were exerted vertically on the denture in four different simulated load cases (LC1–LC4). Two sets of simulations for different implants and denture materials (S1: titanium and titanium; S2: titanium and cobalt-chromium, respectively) were made. Stress outputs were taken as maximum (Pmax) and minimum principal stress (Pmin) and equivalent stress (Peqv) values. The highest peak Pmax values were observed for LC2 (where the modelled masticatory force excluded the cantilevers of the denture extending behind the terminal implants), both regarding the cortical bone (S1 Pmax: 89.57 MPa, S2 Pmax: 102.98 MPa) and trabecular bone (S1 Pmax: 3.03 MPa, S2 Pmax: 2.62 MPa). Overall, LC1—where masticatory forces covered the entire mesio−distal surface of the denture, including the cantilever—was the most advantageous. Peak Pmax values in the cortical bone and the trabecular bone were 14.97–15.87% and 87.96–94.54% higher in the case of S2, respectively. To ensure the long-term maintenance and longevity of treatment for implant-supported restorations in the mandible, efforts to establish the stresses of the surrounding bone in the physiological range, with the most even stress distribution possible, have paramount importance.
- 7 November 2023
- Published by MDPI AG in Dentistry Journal
- Vol. 11 (11) , 261
Open AccessBiomechanical Effects of Different Load Cases with an Implant-Supported Full Bridge on Four Implants in an Edentulous Mandible: A Three-Dimensional Finite Element Analysis (3D-FEA)
The long-term success and predictability of implant-supported restorations largely depends on the biomechanical forces (stresses) acting on implants and the surrounding alveolar bone in the mandible. The aim of our study was to investigate the biomechanical behavior of an edentulous mandible with an implant-supported full bridge on four implants under simulated masticatory forces, in the context of different loading schemes, using a three-dimensional finite element analysis (3D-FEA). A patient-specific 3D finite element model was constructed using pre- and post-implantation computer tomography (CT) images of a patient undergoing implant treatment. Simplified masticatory forces set at 300 N were exerted vertically on the denture in four different simulated load cases (LC1–LC4). Two sets of simulations for different implants and denture materials (S1: titanium and titanium; S2: titanium and cobalt-chromium, respectively) were made. Stress outputs were taken as maximum (Pmax) and minimum principal stress (Pmin) and equivalent stress (Peqv) values. The highest peak Pmax values were observed for LC2 (where the modelled masticatory force excluded the cantilevers of the denture extending behind the terminal implants), both regarding the cortical bone (S1 Pmax: 89.57 MPa, S2 Pmax: 102.98 MPa) and trabecular bone (S1 Pmax: 3.03 MPa, S2 Pmax: 2.62 MPa). Overall, LC1—where masticatory forces covered the entire mesio−distal surface of the denture, including the cantilever—was the most advantageous. Peak Pmax values in the cortical bone and the trabecular bone were 14.97–15.87% and 87.96–94.54% higher in the case of S2, respectively. To ensure the long-term maintenance and longevity of treatment for implant-supported restorations in the mandible, efforts to establish the stresses of the surrounding bone in the physiological range, with the most even stress distribution possible, have paramount importance.
- 2 May 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 143, 105874
Finite element simulations of a single type I collagen fibril, using a novel cross-linking system
- 2 May 2023
- Published by Elsevier in Journal of the Mechanical Behavior of Biomedical Materials
- Vol. 143, 105874
Finite element simulations of a single type I collagen fibril, using a novel cross-linking system
- Open Access
- 29 June 2022
- Published by Road and Bridge Research Institute in Roads and Bridges – Drogi i Mosty
- Vol. 21 (2) , 103-116
Finite element and fatigue analysis of flexible pavements based on temperature profile modeling
The effect of temperature on asphalt pavement structure is of great importance due to the nature of binder used in the asphalt layers. An equivalent temperature is commonly applied to eliminate the effect of temperature dependence in calculations of mechanical properties of the asphalt and of the pavement. Equivalent temperatures, applied as constant values, are supposed to have the same effect on fatigue behavior of the pavement in the period of one year as the real varying weather conditions. The aim of the presented research was to compare the behavior of the pavement under realistic temperature data throughout a single year with the results of the traditional pavement design method. Temperature data were obtained from a previously established weather station. Binder viscosity and asphalt dynamic modulus were defined based on the temperature profile for asphalt layers divided into 19 sublayers. This subdivision was introduced to better reflect the changes in strength characteristics of the asphalt layers along the depth of the structure. Comparison with the simple calculation using the equivalent temperature method showed that the detailed model outlined in this paper can provide better prediction of the overall pavement structural capacity. The focus of this study is to apply asphalt layer discretization to reflect temperature variation and its influence on changes in strength properties of asphalt mixtures. Temperature at each sublayer was estimated using the German specification, dynamic modulus was determined using the Witczak model, and the structural analysis was performed employing the finite element method.
- 29 June 2022
- Published by Road and Bridge Research Institute in Roads and Bridges – Drogi i Mosty
- Vol. 21 (2) , 103-116
Open AccessFinite element and fatigue analysis of flexible pavements based on temperature profile modeling
The effect of temperature on asphalt pavement structure is of great importance due to the nature of binder used in the asphalt layers. An equivalent temperature is commonly applied to eliminate the effect of temperature dependence in calculations of mechanical properties of the asphalt and of the pavement. Equivalent temperatures, applied as constant values, are supposed to have the same effect on fatigue behavior of the pavement in the period of one year as the real varying weather conditions. The aim of the presented research was to compare the behavior of the pavement under realistic temperature data throughout a single year with the results of the traditional pavement design method. Temperature data were obtained from a previously established weather station. Binder viscosity and asphalt dynamic modulus were defined based on the temperature profile for asphalt layers divided into 19 sublayers. This subdivision was introduced to better reflect the changes in strength characteristics of the asphalt layers along the depth of the structure. Comparison with the simple calculation using the equivalent temperature method showed that the detailed model outlined in this paper can provide better prediction of the overall pavement structural capacity. The focus of this study is to apply asphalt layer discretization to reflect temperature variation and its influence on changes in strength properties of asphalt mixtures. Temperature at each sublayer was estimated using the German specification, dynamic modulus was determined using the Witczak model, and the structural analysis was performed employing the finite element method.
- Open Access
- 1 October 2021
- Published by Muszaki Tudomanyos Kozlemenyek in Műszaki Tudományos Közlemények
- Vol. 15 (1) , 76-79
Mechanical Examination of Chicken Vessel with Custom-Built Experimental Equipment
Cardiovascular disease has been decimating humanity for decades. In vivo examination of blood vessels is of great help in the development of numerical models and simulations that can help physicians significantly improve sufferers’ quality of life. For such models, the different mechanical characteristics of the vessels are the input data. Several such mechanical properties of the vessels, such as modulus of elasticity and tensile strength, are determined by a tensile test. In the course of our research, an experimental device was developed and tested which is suitable for biaxial tensile tests of blood vessels, which we present through the examination of chicken blood vessels.
- 1 October 2021
- Published by Muszaki Tudomanyos Kozlemenyek in Műszaki Tudományos Közlemények
- Vol. 15 (1) , 76-79
Open AccessMechanical Examination of Chicken Vessel with Custom-Built Experimental Equipment
Cardiovascular disease has been decimating humanity for decades. In vivo examination of blood vessels is of great help in the development of numerical models and simulations that can help physicians significantly improve sufferers’ quality of life. For such models, the different mechanical characteristics of the vessels are the input data. Several such mechanical properties of the vessels, such as modulus of elasticity and tensile strength, are determined by a tensile test. In the course of our research, an experimental device was developed and tested which is suitable for biaxial tensile tests of blood vessels, which we present through the examination of chicken blood vessels.