Jens Duru
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jens Duru has a total of 71 co-authors. Here are the top co-authors by number of shared publications:
- János Vörös
ETH Zurich
10 shared publications - Tobias Ruff
Laboratory of Biosensors and Bioelectronics Institute for Biomedical Engineering Zurich Switzerland
10 shared publications - Stephan Johannes Ihle
Laboratory of Biosensors and Bioelectronics, Institute for Biomedical Engineering, University and ETH Zurich
6 shared publications - Benedikt Maurer
Laboratory of Biosensors and Bioelectronics Institute for Biomedical Engineering University and ETH Zurich Zurich Switzerland
4 shared publications - Julian Hengsteler
Laboratory of Biosensors and Bioelectronics Institute for Biomedical Engineering Zurich Switzerland
4 shared publications - Christina M. Tringides
Laboratory of Biosensors and Bioelectronics, Institute of Biomedical Engineering, Department of Information Technology and Electrical Engineering, ETH Zurich, Gloriastrasse 37/39, Zurich, 8092, Switzerland
3 shared publications
Latest Publications
- Open Access
Spatially defined axonal guidance in neural organoids with micropatterned microfluidic channels
Three-dimensional stem cell-derived neural organoids provide a promising platform for investigating early brain development and interregional circuit formation. Although co-culture of region-specific organoids into assembloids has enabled the study of cortical and subcortical interactions, these models lack directional specificity and spatial control, limiting their ability to recapitulate canonical circuit architecture. Here, we present a microfluidic platform for constructing directional and tunable interregional circuits while preserving anatomical distinction. This system, which we term directoids incorporates micropatterned polydimethylsiloxane (PDMS) microstructures to control uni- and bidirectional axonal growth between cortical and thalamic organoids. We observed a 70.4% success rate of axons traversing the full channel length in the permissive direction and reaching the opposing organoid, whereas no neurites successfully crossed the probative direction. These results demonstrate robust directionally bias in axon outgrowth and establish a scalable, reproducible strategy for controlling asymmetric connectivity between anatomically distinct neural organoids. Using high-density CMOS microelectrode arrays, we further validated directional tuning of extracellular action potential propagation within directoid microchannels, a feature not observed in straight-channel connectoid controls. Directoids also exhibited significant asymmetry in firing rates between channel entry and exit sites, consistent with engineered bias in signal flow. This provides an experimental paradigm for dissecting how anatomical connectivity and functional activity converge to shape neuronal networks. Together, these findings establish a microfluidic platform for investigating the mechanisms underlying hierarchical circuit formation, regional specification, and functional integration in developing human neural organoid models at cellular resolution not possible in vivo.
Open AccessSpatially defined axonal guidance in neural organoids with micropatterned microfluidic channels
Three-dimensional stem cell-derived neural organoids provide a promising platform for investigating early brain development and interregional circuit formation. Although co-culture of region-specific organoids into assembloids has enabled the study of cortical and subcortical interactions, these models lack directional specificity and spatial control, limiting their ability to recapitulate canonical circuit architecture. Here, we present a microfluidic platform for constructing directional and tunable interregional circuits while preserving anatomical distinction. This system, which we term directoids incorporates micropatterned polydimethylsiloxane (PDMS) microstructures to control uni- and bidirectional axonal growth between cortical and thalamic organoids. We observed a 70.4% success rate of axons traversing the full channel length in the permissive direction and reaching the opposing organoid, whereas no neurites successfully crossed the probative direction. These results demonstrate robust directionally bias in axon outgrowth and establish a scalable, reproducible strategy for controlling asymmetric connectivity between anatomically distinct neural organoids. Using high-density CMOS microelectrode arrays, we further validated directional tuning of extracellular action potential propagation within directoid microchannels, a feature not observed in straight-channel connectoid controls. Directoids also exhibited significant asymmetry in firing rates between channel entry and exit sites, consistent with engineered bias in signal flow. This provides an experimental paradigm for dissecting how anatomical connectivity and functional activity converge to shape neuronal networks. Together, these findings establish a microfluidic platform for investigating the mechanisms underlying hierarchical circuit formation, regional specification, and functional integration in developing human neural organoid models at cellular resolution not possible in vivo.
- Top Cited PapersOpen Access
- 2 March 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (6) , 2074-2089
Inkube: an all-in-one solution for neuron culturing, electrophysiology, and fluidic exchange
Culturing neuronal networks in vitro is a tedious and time-consuming endeavor. In addition, how the composition of the culture medium and environmental variables such as temperature, osmolarity, and pH affect the spiking behavior of neuronal cultures is difficult to study using electrophysiology. In this work, we present “inkube”, an incubation system that has been combined with an electrophysiology setup and a fully automatic perfusion system. This setup allows for the precise measurement and control of the temperature of up to 4 microelectrode arrays (MEAs) in parallel. In addition, neuronal activity can be electrically induced and recorded from the MEAs. Inkube can continuously monitor the medium level to automatically readjust osmolarity. Using inkube's unique capability to precisely control the environmental variables of a neural culture, we found that medium evaporation influences the spiking response. Moreover, decreasing medium temperature by only 1.5 °C significantly affected spike latency, a measure commonly used to show plasticity in in vitro experiments. We finally provide a proof-of-concept experiment for drug screening applications, where inkube automatically and precisely varies the concentration of magnesium ions in the medium. Given its high level of autonomy, the system can record, stimulate, and control the medium continuously without user intervention. Both the hardware and the software of inkube are completely open-source.
- 2 March 2026
- Published by Royal Society of Chemistry (RSC) in Lab on a Chip
- Vol. 26 (6) , 2074-2089
Top Cited PapersOpen AccessInkube: an all-in-one solution for neuron culturing, electrophysiology, and fluidic exchange
Culturing neuronal networks in vitro is a tedious and time-consuming endeavor. In addition, how the composition of the culture medium and environmental variables such as temperature, osmolarity, and pH affect the spiking behavior of neuronal cultures is difficult to study using electrophysiology. In this work, we present “inkube”, an incubation system that has been combined with an electrophysiology setup and a fully automatic perfusion system. This setup allows for the precise measurement and control of the temperature of up to 4 microelectrode arrays (MEAs) in parallel. In addition, neuronal activity can be electrically induced and recorded from the MEAs. Inkube can continuously monitor the medium level to automatically readjust osmolarity. Using inkube's unique capability to precisely control the environmental variables of a neural culture, we found that medium evaporation influences the spiking response. Moreover, decreasing medium temperature by only 1.5 °C significantly affected spike latency, a measure commonly used to show plasticity in in vitro experiments. We finally provide a proof-of-concept experiment for drug screening applications, where inkube automatically and precisely varies the concentration of magnesium ions in the medium. Given its high level of autonomy, the system can record, stimulate, and control the medium continuously without user intervention. Both the hardware and the software of inkube are completely open-source.
- Open Access
- 9 February 2025
- Published by Wiley in Advanced Functional Materials
- Vol. 35 (12)
An Implantable Biohybrid Neural Interface Toward Synaptic Deep Brain Stimulation
In patients with sensory nerve loss, such as those experiencing optic nerve damage that leads to vision loss, the thalamus no longer receives the corresponding sensory input. To restore functional sensory input, it is necessary to bypass the damaged circuits, which can be achieved by directly stimulating the appropriate sensory thalamic nuclei. However, available deep brain stimulation electrodes do not provide the resolution required for effective sensory restoration. Therefore, this work develops an implantable biohybrid neural interface aimed at innervating and synaptically stimulating deep brain targets. The interface combines a stretchable stimulation array with an aligned microfluidic axon guidance system seeded with neural spheroids to facilitate the development of a 3 mm long nerve‐like structure. A bioresorbable hydrogel nerve conduit is used as a bridge between the tissue and the biohybrid implant. Stimulation of the spheroids within the biohybrid structure in vitro and use of high‐density CMOS microelectrode arrays show faithful activity conduction across the device. Although functional in vivo innervation and synapse formation has not yet been achieved in this study, implantation of the biohybrid nerve onto the mouse cortex shows that neural spheroids grow axons in vivo and remain functionally active for more than 22 days post‐implantation.
- 9 February 2025
- Published by Wiley in Advanced Functional Materials
- Vol. 35 (12)
Open AccessAn Implantable Biohybrid Neural Interface Toward Synaptic Deep Brain Stimulation
In patients with sensory nerve loss, such as those experiencing optic nerve damage that leads to vision loss, the thalamus no longer receives the corresponding sensory input. To restore functional sensory input, it is necessary to bypass the damaged circuits, which can be achieved by directly stimulating the appropriate sensory thalamic nuclei. However, available deep brain stimulation electrodes do not provide the resolution required for effective sensory restoration. Therefore, this work develops an implantable biohybrid neural interface aimed at innervating and synaptically stimulating deep brain targets. The interface combines a stretchable stimulation array with an aligned microfluidic axon guidance system seeded with neural spheroids to facilitate the development of a 3 mm long nerve‐like structure. A bioresorbable hydrogel nerve conduit is used as a bridge between the tissue and the biohybrid implant. Stimulation of the spheroids within the biohybrid structure in vitro and use of high‐density CMOS microelectrode arrays show faithful activity conduction across the device. Although functional in vivo innervation and synapse formation has not yet been achieved in this study, implantation of the biohybrid nerve onto the mouse cortex shows that neural spheroids grow axons in vivo and remain functionally active for more than 22 days post‐implantation.
- Open Access
An in vitro platform for characterizing axonal electrophysiology of individual human iPSC-derived nociceptors
Current treatments against severe forms of neuropathic pain demonstrate insufficient efficacy or lead to unwanted side effects as they fail to specifically target the affected nociceptors - a specialized subclass of sensory neurons conveying potentially damaging stimuli information to the central nervous system. Neuropathic pain may involve different nociceptor subtypes in different patients. Tools that can distinguish nociceptive axons would enable a more targeted compound screening. Therefore, we developed an in vitro platform combining a CMOS-based high-density microelectrode array with a polydimethylsiloxane (PDMS) guiding microstructure that captures the electrophysiological responses of nociceptors. Human induced pluripotent stem cell-derived (iPSC) nociceptors were cultured at low density with axons distributed through parallel 4 × 10 µm microchannels exiting the seeding well before converging to a bigger axon-collecting channel. This configuration allowed the measurement of stimulation-induced responses of individual axons. Nociceptors were found to exhibit a great diversity of electrophysiological response profiles that can be classified into different functional archetypes. Moreover, we show that some responses are affected by applying the TRPV1 agonist capsaicin. Overall, results using our platform demonstrate that we were able to distinguish nociceptive axons from different subtypes. The platform provides a promising tool for screening potential candidates for nociceptor-specific drugs.
Open AccessAn in vitro platform for characterizing axonal electrophysiology of individual human iPSC-derived nociceptors
Current treatments against severe forms of neuropathic pain demonstrate insufficient efficacy or lead to unwanted side effects as they fail to specifically target the affected nociceptors - a specialized subclass of sensory neurons conveying potentially damaging stimuli information to the central nervous system. Neuropathic pain may involve different nociceptor subtypes in different patients. Tools that can distinguish nociceptive axons would enable a more targeted compound screening. Therefore, we developed an in vitro platform combining a CMOS-based high-density microelectrode array with a polydimethylsiloxane (PDMS) guiding microstructure that captures the electrophysiological responses of nociceptors. Human induced pluripotent stem cell-derived (iPSC) nociceptors were cultured at low density with axons distributed through parallel 4 × 10 µm microchannels exiting the seeding well before converging to a bigger axon-collecting channel. This configuration allowed the measurement of stimulation-induced responses of individual axons. Nociceptors were found to exhibit a great diversity of electrophysiological response profiles that can be classified into different functional archetypes. Moreover, we show that some responses are affected by applying the TRPV1 agonist capsaicin. Overall, results using our platform demonstrate that we were able to distinguish nociceptive axons from different subtypes. The platform provides a promising tool for screening potential candidates for nociceptor-specific drugs.
- Open Access
Inkube: An all-in-one solution for neuron culturing, electrophysiology, and fluidic exchange
Culturing neuronal networks in vitro is a tedious and time-consuming endeavor. In addition, how the composition of the culture medium and environmental variables such as temperature, osmolarity, and pH affect the spiking behavior of neuronal cultures is difficult to study using electrophysiology. In this work, we present “inkube”, an incubation system that has been combined with an electrophysiology setup and a fully automatic perfusion system. This setup allows for the precise measurement and control of the temperature of up to 4 microelectrode arrays (MEAs) in parallel. In addition, neuronal activity can be electrically induced and recorded from the MEAs. inkube can continuously monitor the medium level to automatically readjust osmolarity. Using inkube’s unique capability to precisely control the environmental variables of a neural culture, we found that medium evaporation influences the spiking response. Moreover, decreasing medium temperature by only 1.5°C significantly affected spike latency, a measure commonly used to show plasticity in in vitro experiments. We finally provide a proof-of-concept experiment for drug screening applications, where inkube automatically and precisely varies the concentration of magnesium ions in the medium. Given its high level of autonomy, the system can record, stimulate, and control the medium continuously without user intervention. Both the hardware and the software of inkube are completely open-source. Highlights: Low-cost, open-hardware/open-software electrophysiology setup Full incubation solution: Temperature, CO 2 , and humidity control Perfusion system for automatic fluidic exchange and drug testing with volume feedback
Open AccessInkube: An all-in-one solution for neuron culturing, electrophysiology, and fluidic exchange
Culturing neuronal networks in vitro is a tedious and time-consuming endeavor. In addition, how the composition of the culture medium and environmental variables such as temperature, osmolarity, and pH affect the spiking behavior of neuronal cultures is difficult to study using electrophysiology. In this work, we present “inkube”, an incubation system that has been combined with an electrophysiology setup and a fully automatic perfusion system. This setup allows for the precise measurement and control of the temperature of up to 4 microelectrode arrays (MEAs) in parallel. In addition, neuronal activity can be electrically induced and recorded from the MEAs. inkube can continuously monitor the medium level to automatically readjust osmolarity. Using inkube’s unique capability to precisely control the environmental variables of a neural culture, we found that medium evaporation influences the spiking response. Moreover, decreasing medium temperature by only 1.5°C significantly affected spike latency, a measure commonly used to show plasticity in in vitro experiments. We finally provide a proof-of-concept experiment for drug screening applications, where inkube automatically and precisely varies the concentration of magnesium ions in the medium. Given its high level of autonomy, the system can record, stimulate, and control the medium continuously without user intervention. Both the hardware and the software of inkube are completely open-source. Highlights: Low-cost, open-hardware/open-software electrophysiology setup Full incubation solution: Temperature, CO 2 , and humidity control Perfusion system for automatic fluidic exchange and drug testing with volume feedback
- Open Access
An implantable biohybrid nerve model towards synaptic deep brain stimulation
Restoring functional vision in blind patients lacking a healthy optic nerve requires bypassing retinal circuits, ideally, by directly stimulating the visual thalamus. However, available deep brain stimulation electrodes do not provide the resolution required for vision restoration. We developed an implantable biohybrid nerve model designed for synaptic stimulation of deep brain targets. The interface combines a stretchable stimulation array with an aligned microfluidic axon guidance system seeded with neural spheroids to facilitate the development of a 3 mm long nerve-like structure. A bioresorbable hydrogel nerve conduit was used as a bridge between the tissue and the biohybrid implant. We demonstrated stimulation of spheroids within the biohybrid structure in vitro and used high-density CMOS microelectrode arrays to show faithful activity conduction across the device. Finally, implantation of the biohybrid nerve onto the mouse cortex showed that neural spheroids grow axons in vivo and remain functionally active for more than 22 days post-implantation.
Open AccessAn implantable biohybrid nerve model towards synaptic deep brain stimulation
Restoring functional vision in blind patients lacking a healthy optic nerve requires bypassing retinal circuits, ideally, by directly stimulating the visual thalamus. However, available deep brain stimulation electrodes do not provide the resolution required for vision restoration. We developed an implantable biohybrid nerve model designed for synaptic stimulation of deep brain targets. The interface combines a stretchable stimulation array with an aligned microfluidic axon guidance system seeded with neural spheroids to facilitate the development of a 3 mm long nerve-like structure. A bioresorbable hydrogel nerve conduit was used as a bridge between the tissue and the biohybrid implant. We demonstrated stimulation of spheroids within the biohybrid structure in vitro and used high-density CMOS microelectrode arrays to show faithful activity conduction across the device. Finally, implantation of the biohybrid nerve onto the mouse cortex showed that neural spheroids grow axons in vivo and remain functionally active for more than 22 days post-implantation.
- Open Access
A modular and flexible open source cell incubator system for mobile and stationary use
Culturing living cells in vitro requires the maintenance of physiological conditions for extended periods of time. Here, we introduce a versatile and affordable incubation system, addressing the limitations of traditional incubation systems. Conventionally, stationary cell incubators maintain constant temperature and gas levels for in vitro cell culturing. Combining such incubators with additional lab equipment proves challenging. The presented platform offers modularity and adaptability, enabling customization to diverse experimental needs. The system includes a main unit with a user-friendly interface as well as an interchangeable incubation chamber. We present two incubation chambers targeting two completely different use cases. The first chamber, named “inkugo” facilitates the transportation of cells for up to two hours without external power and for more than a day without an external CO 2 source. The second chamber termed “inkubox” was designed to enable continuous electrophysiological recordings. Recordings from up to four neural cultures growing on high-density microelectrode arrays can be performed in parallel. The system’s unique feature lies in its separability of control and incubation components, allowing one control unit to manage various custom chambers. The design’s simplicity and the use of widely accessible components make the here proposed incubation system replicable for any laboratory. This platform fosters collaboration and experimentation in both decentralized and traditional laboratory settings, making it an invaluable addition to any cell culturing pipeline. Specifications table
Open AccessA modular and flexible open source cell incubator system for mobile and stationary use
Culturing living cells in vitro requires the maintenance of physiological conditions for extended periods of time. Here, we introduce a versatile and affordable incubation system, addressing the limitations of traditional incubation systems. Conventionally, stationary cell incubators maintain constant temperature and gas levels for in vitro cell culturing. Combining such incubators with additional lab equipment proves challenging. The presented platform offers modularity and adaptability, enabling customization to diverse experimental needs. The system includes a main unit with a user-friendly interface as well as an interchangeable incubation chamber. We present two incubation chambers targeting two completely different use cases. The first chamber, named “inkugo” facilitates the transportation of cells for up to two hours without external power and for more than a day without an external CO 2 source. The second chamber termed “inkubox” was designed to enable continuous electrophysiological recordings. Recordings from up to four neural cultures growing on high-density microelectrode arrays can be performed in parallel. The system’s unique feature lies in its separability of control and incubation components, allowing one control unit to manage various custom chambers. The design’s simplicity and the use of widely accessible components make the here proposed incubation system replicable for any laboratory. This platform fosters collaboration and experimentation in both decentralized and traditional laboratory settings, making it an invaluable addition to any cell culturing pipeline. Specifications table
- Open Access
- 18 August 2023
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 239, 115591
Investigation of the input-output relationship of engineered neural networks using high-density microelectrode arrays
- 18 August 2023
- Published by Elsevier in Biosensors and Bioelectronics
- Vol. 239, 115591
Open AccessInvestigation of the input-output relationship of engineered neural networks using high-density microelectrode arrays
- Open Access
- 6 July 2023
- Published by Springer Nature in Research Square
Aptamer-functionalized interface nanopores enable amino acid-specific single-molecule proteomics
Single-molecule proteomics based on nanopore technology has made significant advances in recent years. However, to achieve nanopore sensing with single amino acid resolution, several bottlenecks must be tackled: controlling nanopore sizes with nanoscale precision and slowing molecular translocations events. Herein, we address these challenges by coupling amino acid-specific DNA aptamers to interface nanopores with dynamically tunable pores. A phenylalanine aptamer was used as a proof-of-concept; aptamer recognition of phenylalanine moieties led to retention of specific peptides, slowing translocation speeds. We decoupled specific binding between aptamers and peptides with phenylalanine moieties from nonspecific interactions (e.g., electrostatics) using optical waveguide lightmode spectroscopy. Aptamer-modified interface nanopores differentiated peptides containing phenylalanine vs. control peptides with structurally similar amino acids (i.e., tyrosine and tryptophan). When the duration of aptamer-target interactions inside the nanopore were prolonged by lowering the applied voltage, discrete ionic current levels with repetitive motifs were observed. Such reoccurring signatures in the measured signal suggest that the proposed method has the possibility to resolve amino acid-specific aptamer recognition, a step towards single-molecule proteomics.
- 6 July 2023
- Published by Springer Nature in Research Square
Open AccessAptamer-functionalized interface nanopores enable amino acid-specific single-molecule proteomics
Single-molecule proteomics based on nanopore technology has made significant advances in recent years. However, to achieve nanopore sensing with single amino acid resolution, several bottlenecks must be tackled: controlling nanopore sizes with nanoscale precision and slowing molecular translocations events. Herein, we address these challenges by coupling amino acid-specific DNA aptamers to interface nanopores with dynamically tunable pores. A phenylalanine aptamer was used as a proof-of-concept; aptamer recognition of phenylalanine moieties led to retention of specific peptides, slowing translocation speeds. We decoupled specific binding between aptamers and peptides with phenylalanine moieties from nonspecific interactions (e.g., electrostatics) using optical waveguide lightmode spectroscopy. Aptamer-modified interface nanopores differentiated peptides containing phenylalanine vs. control peptides with structurally similar amino acids (i.e., tyrosine and tryptophan). When the duration of aptamer-target interactions inside the nanopore were prolonged by lowering the applied voltage, discrete ionic current levels with repetitive motifs were observed. Such reoccurring signatures in the measured signal suggest that the proposed method has the possibility to resolve amino acid-specific aptamer recognition, a step towards single-molecule proteomics.
- Open Access
Engineering circuits of human iPSC-derived neurons and rat primary glia
Novel in vitro platforms based on human neurons are needed to improve early drug testing and address the stalling drug discovery in neurological disorders. Topologically controlled circuits of human induced pluripotent stem cell (iPSC)-derived neurons have the potential to become such a testing system. In this work, we build in vitro co-cultured circuits of human iPSC-derived neurons and rat primary glial cells using microfabricated polydimethylsiloxane (PDMS) structures on microelectrode arrays (MEAs). Such circuits are created by seeding either dissociated cells or pre-aggregated spheroids at different neuron-to-glia ratios. Furthermore, an antifouling coating is developed to prevent axonal overgrowth in undesired locations of the microstructure. We assess the electrophysiological properties of different types of circuits over more than 50 days, including their stimulation-induced neural activity. Finally, we demonstrate the effect of magnesium chloride on the electrical activity of our iPSC circuits as a proof-of-concept for screening of neuroactive compounds.
Open AccessEngineering circuits of human iPSC-derived neurons and rat primary glia
Novel in vitro platforms based on human neurons are needed to improve early drug testing and address the stalling drug discovery in neurological disorders. Topologically controlled circuits of human induced pluripotent stem cell (iPSC)-derived neurons have the potential to become such a testing system. In this work, we build in vitro co-cultured circuits of human iPSC-derived neurons and rat primary glial cells using microfabricated polydimethylsiloxane (PDMS) structures on microelectrode arrays (MEAs). Such circuits are created by seeding either dissociated cells or pre-aggregated spheroids at different neuron-to-glia ratios. Furthermore, an antifouling coating is developed to prevent axonal overgrowth in undesired locations of the microstructure. We assess the electrophysiological properties of different types of circuits over more than 50 days, including their stimulation-induced neural activity. Finally, we demonstrate the effect of magnesium chloride on the electrical activity of our iPSC circuits as a proof-of-concept for screening of neuroactive compounds.