Dimitrios A. Koutsouras has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Author Correction: Control of spatiotemporal activation of organ-specific fibers in the swine vagus nerve by intermittent interferential current stimulation

    by Nicolò Rossetti, Weiguo Song, Philipp Schnepel, Naveen Jayaprakash, Dimitrios A. Koutsouras, Mark Fichman, Jason Wong, Todd Levy, Mohamed Elgohary, Khaled Qanud, et al.

  • Conducting Polymer Devices for in vitro Electrophysiology

    by Dimitrios Koutsouras

    Dispositifs à base de Polymères Conducteurs pour l’Électrophysiologie in vitro: La bioélectronique est un domaine émergent qui vise à combiner les mondes de la biologie et de l'électronique. Les matériaux organiques présentent un ensemble de caractéristiques uniques qui les rendent candidats idéaux pour répondre aux contraintes spécifiques de ce domaine. Leur flexibilité leur donne une meilleure stabilité mécanique, tandis que leur nature de conducteurs ioniques et électroniques leur permet d’interférer parfaitement entre un tissu vivant et un dispositif électronique. En outre, ils présentent des interfaces non oxydées pour des interactions biologiques plus efficaces. Il est également possible de modifier chimiquement ces matériaux afin de les fonctionnaliser. Ces idées, ainsi que les différentes approches de fabrication des dispositifs organiques sont présentées au chapitre 1.L’électrode est le principal outil expérimental pour l’électrophysiologie in vitro. Les principes physiques du fonctionnement de l’électrode sont donc tout d’abord présentés au chapitre 2. Dans les chapitres 3 et 4, les connaissances acquises à partir de la modélisation de l’électrode sont mises en applications sur des mesures biologiques réelles. Le chapitre 3 présente des enregistrements d'activité de cellules hippocampiques de culture et le chapitre 4 de cellules pancréatiques.Le chapitre 5 introduit un autre dispositif, le transistor électrochimique organique (OECT) et présent une carte électronique de conversion qui pourrait faciliter l’usage d’OECT dans futures applications d’électrophysiologie. Le chapitre 6 clôture cette thèse en décrivant des mesures effectuées sur des astrocytes à l’aide d’OECT.

  • Open Access

    Neural Interfaces for Bioelectronic Medicine

    by Dimitrios A. Koutsouras, Geert Langereis

    Bioelectronic medicine (BEM) is an emerging scientific field that aims to revolutionize the way we understand and treat disease by using electrical impulses for diagnosis and therapy. It is an interdisciplinary endeavour that draws on advances in microelectronics, information technology, materials science, and medicine, and it holds strong promise for addressing currently unmet medical needs. At its core, BEM seeks to develop implantable devices capable of modulating neuronal circuits and biological functions in a precise, targeted, and adaptable manner. Neural interfaces play a pivotal role within this therapeutic paradigm, as they must safely probe and interact with the nervous system while maintaining long‑term stability and biocompatibility. This editorial introduces the papers published in our collection “Neural Interfaces for Bioelectronic Medicine”. The included works present the clinical landscape of neuromodulation, examine mechanisms of device failure and reliability, introduce electrode technologies with improved biocompatibility and selectivity, and explore the therapeutic potential of alternative neuromodulation strategies, such as ultrasound and magnetoelectric nanoparticle‑based approaches, supported by computational models. Together, these contributions highlight both the opportunities and the challenges that must be addressed for bioelectronic medicine to fully flourish. They also identify the key technological advancements that will shape the future of neural interfaces and enable the next generation of bioelectronic therapies. We hope you enjoy this collection as much as we did.

  • Open Access

    Control of spatiotemporal activation of organ-specific fibers in the swine vagus nerve by intermittent interferential current stimulation

    by Nicolò Rossetti, Weiguo Song, Philipp Schnepel, Naveen Jayaprakash, Dimitrios A. Koutsouras, Mark Fichman, Jason Wong, Todd Levy, Mohamed Elgohary, Khaled Qanud, et al.

    Vagus nerve stimulation (VNS) is emerging as potential treatment for several chronic diseases. However, limited control of fiber activation, e.g., to promote desired effects over side effects, restricts clinical translation. Towards that goal, we describe a VNS method consisting of intermittent, interferential sinusoidal current stimulation (i2CS) through multi-contact epineural cuffs. In experiments in anesthetized swine, i2CS elicits nerve potentials and organ responses, from lungs and laryngeal muscles, that are distinct from equivalent non-interferential sinusoidal stimulation. Resection and micro-CT imaging of a previously stimulated nerve, to resolve anatomical trajectories of nerve fascicles, demonstrate that i2CS responses are explained by activation of organ-specific fascicles rather than the entire nerve. Physiological responses in swine and activity of single fibers in anatomically realistic, physiologically validated biophysical vagus nerve models indicate that i2CS reduces fiber activation at the interference focus. Experimental and modeling results demonstrate that current steering and beat and repetition frequencies predictably shape the spatiotemporal pattern of fiber activation, allowing tunable and precise control of nerve and organ responses. When compared to equivalent sinusoidal stimulation in the same animals, i2CS produces reduced levels of a side-effect by larger laryngeal fibers, while attaining similar levels of a desired effect by smaller bronchopulmonary fibers.


  • Open Access

    Organic Bioelectronics in Microphysiological Systems: Bridging the Gap Between Biological Systems and Electronic Technologies

    by Pauline Coquart, Andrea El Haddad, Dimitrios A. Koutsouras, Johanna Bolander

    The growing burden of degenerative, cardiovascular, neurodegenerative, and cancerous diseases necessitates innovative approaches to improve our pathophysiological understanding and ability to modulate biological processes. Organic bioelectronics has emerged as a powerful tool in this pursuit, offering a unique ability to interact with biology due to the mixed ionic–electronic conduction and tissue-mimetic mechanical properties of conducting polymers (CPs). These materials enable seamless integration with biological systems across different levels of complexity, from monolayers to complex 3D models, microfluidic chips, and even clinical applications. CPs can be processed into diverse formats, including thin films, hydrogels, 3D scaffolds, and electrospun fibers, allowing the fabrication of advanced bioelectronic devices such as multi-electrode arrays, transistors (EGOFETs, OECTs), ion pumps, and photoactuators. This review examines the integration of CP-based bioelectronics in vivo and in in vitro microphysiological systems, focusing on their ability to monitor key biological events, including electrical activity, metabolic changes, and biomarker concentrations, as well as their potential for electrical, mechanical, and chemical stimulation. We highlight the versatility and biocompatibility of CPs and their role in advancing personalized medicine and regenerative therapies and discuss future directions for organic bioelectronics to bridge the gap between biological systems and electronic technologies.


  • Open Access

    Control of spatiotemporal activation of organ-specific fibers in the vagus nerve by intermittent interferential current stimulation

    by Stavros Zanos, Nicolo Rossetti, Weiguo Song, Philipp Schnepel, Naveen Jayaprakash, Dimitrios Koutsouras, Marc Fichman, Jason Wong, Todd Levy, Mohamed Elgohary, et al.

    Vagus nerve stimulation (VNS) is emerging as potential treatment for several chronic diseases, however, limited control of fiber activation to promote desired effects over side effects restricts clinical translation. Here we describe a new VNS method that relies on intermittent, interferential sinusoidal current stimulation (i2CS) through implanted, multi-contact epineural cuffs. In swine, i2CS elicits specific nerve potentials and end organ responses, distinct from equivalent non-interferential sinusoidal stimulation. Comparing experimental results with anatomical trajectories of nerve fascicles from end organs to the stimulation electrode indicates that i2CS activates organ-specific fascicles rather than the entire nerve. Experimental results and anatomically realistic, physiologically validated biophysical models of the vagus nerve demonstrate that i2CS reduces fiber activation at the focus of interference. Current steering and repetition frequency determine spatiotemporal pattern of vagal fiber activation, allowing tunable and precise control of neural and organ responses. In experiments in a cohort of anesthetized swine, i2CS has improved selectivity for a desired effect, mediated by smaller bronchopulmonary fibers, over a side effect, mediated by larger laryngeal fibers, compared to non-interferential sinusoidal or square pulse VNS.

  • Open Access

    The rise of bioelectronic medicine

    by Dimitrios A. Koutsouras, George G. Malliaras, Geert Langereis

    Bioelectronic Medicine (BEM), which uses implantable electronic medical devices to interface with electrically active tissues, aspires to revolutionize the way we understand and fight disease. By leveraging knowledge from microelectronics, materials science, information technology, neuroscience and medicine, BEM promises to offer novel solutions that address unmet clinical needs and change the concept of therapeutics. This perspective communicates our vision for the future of BEM and presents the necessary steps that need to be taken and the challenges that need to be faced before this new technology can flourish.


  • Open Access

    Submicron Vertical Channel Organic Electrochemical Transistors with Ultrahigh Transconductance

    by Dimitrios A. Koutsouras, Fabrizio Torricelli, Paul W.M. Blom

    Organic electrochemical transistors (OECTs) belong to the class of electrolyte gated organic transistors (EGOTs) that offer a smooth interface with biology in combination with high transconductance values of typically a few mS. Fabrication‐wise, though, most of the up‐to‐date reported devices are limited to two dimensional structures, where the transistor channel is patterned on the same plane as the source and drain electrodes. Here, a method is introduced for the fabrication of integrated vertical channel OECTs (vOECTs) with submicron channel length. By employing electrodeposition, a vertical channel sandwiched between the source and drain electrodes is created. Channel lengths down to 60 nm are demonstrated, giving rise to ultrahigh transconductance of up to 275 mS. Accounting for the voltage loss on the device connection tracks, an intrinsic transconductance of vOECTs of 500 mS is found. The vOECTs are three‐dimensional transistors finding relevant application in “organ‐on‐a‐chip” and implantable devices, where high amplification and small footprint are demanded.


  • Open Access

    Organic neuromorphic electronics for sensorimotor integration and learning in robotics

    by Imke Krauhausen, Dimitrios A. Koutsouras, Armantas Melianas, Scott T. Keene, Katharina Lieberth, Hadrien Ledanseur, Rajendar Sheelamanthula, Alexander Giovannitti, Fabrizio Torricelli, Iain Mcculloch, et al.

    A robot learns to follow a path to exit a maze through sensorimotor learning that is induced by an organic neuromorphic circuit.


  • Open Access

    Efficient Gating of Organic Electrochemical Transistors with In‐Plane Gate Electrodes

    by Dimitrios A. Koutsouras, Fabrizio Torricelli, Paschalis Gkoupidenis, Paul W. M. Blom

    Organic electrochemical transistors (OECTs) are electrolyte‐gated transistors, employing an electrolyte between their gate and channel instead of an insulating layer. For efficient gating, non‐polarizable electrodes, for example, Ag/AgCl, are typically used but unfortunately, this simple approach limits the options for multiple gate integration. Patterned polarizable Au gates on the other hand, show strongly reduced gating due to a large voltage drop at the gate/electrolyte interface. Here, an alternative, simple yet effective method for efficient OECT gating by scalable in‐plane gate electrodes, is demonstrated. The fact that poly(3,4‐ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) exhibits a volumetric capacitance in an electrolyte is made use of. As a result, the capacitance of PEDOT:PSS‐based gates can be strongly enhanced by increasing their thickness, thereby reducing the voltage loss at the gate/electrolyte interface. By combining spin coating and electrodeposition, planar electrodes of various thicknesses are created on a multi‐gated OECT chip and their effect on the gating efficiency, examined. It is shown that the gating performed by an in‐plane PEDOT:PSS electrode can be tuned to be comparable to the one obtained by a Ag/AgCl electrode. Overall, the realization of efficient gating with in‐plane electrodes paves the way toward integration of OECT‐based biosensors and “organ‐on‐a‐chip” platforms.