Van-Tinh Huynh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Van-Tinh Huynh has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Kyoungsik Chang
Department of Mechanical Engineering, University of Ulsan, Ulsan, South Korea
2 shared publications - Sang-Eun Lee
Division of Cardiology, Department of Internal Medicine, College of Medicine, Ewha Womans University, Seoul, South Korea
2 shared publications - Dong Kim
School of Mechanical Engineering, University of Ulsan, Ulsan, Republic of Korea
1 shared publication
Latest Publications
- 3 September 2024
- Published by Springer Nature in Journal of Visualization
- Vol. 28 (1) , 59-81
Numerical investigations of heat transfer enhancement in ionic liquid-piston compressor using cooling pipes
- 3 September 2024
- Published by Springer Nature in Journal of Visualization
- Vol. 28 (1) , 59-81
Numerical investigations of heat transfer enhancement in ionic liquid-piston compressor using cooling pipes
- Open Access
Numerical Investigation of the Thermal Performance of a Hybrid Phase Change Material and Forced Air Cooling System for a Three-Cell Lithium-Ion Battery Module
The thermal performance of a lithium-ion battery module comprising three cells contained within a casing was investigated at discharge rates of 3C and 5C with three different cooling strategies: forced air, phase-change material (PCM), and a hybrid system using a combination of forced air and the PCM. Three levels of fan speed (5000 rpm; 7000 rpm; and 9000 rpm) for cooling air flow were considered. A numerical simulation of heat transfer was performed using the ANSYS Fluent software. The electrochemical modelling of a battery was developed based on the NTGK approach, and the phase-change phenomenon was treated as an enthesis–porosity problem. The composite PCM, aluminum metal foam embedded in n-octadecane, had better heat dissipation performance than forced air convection. The PCM is significantly more effective at heat dissipation than forced air. Interestingly, when using a hybrid cooling system that combines forced air and a PCM, although it meets the operational requirements for Li-ion batteries in regard to maximum temperature and temperature uniformity at a 3C discharge rate, the airflow appears to have a negligible effect on thermal management and yields an indiscernible change in temperature. This can be attributed to a complex flow pattern that developed in a casing as a result of the suboptimal design of the inlet and outlet. Further studies will be required for the optimal positioning of the inlet and outlet, as well as the effectiveness of combining liquid cooling methods.
Open AccessNumerical Investigation of the Thermal Performance of a Hybrid Phase Change Material and Forced Air Cooling System for a Three-Cell Lithium-Ion Battery Module
The thermal performance of a lithium-ion battery module comprising three cells contained within a casing was investigated at discharge rates of 3C and 5C with three different cooling strategies: forced air, phase-change material (PCM), and a hybrid system using a combination of forced air and the PCM. Three levels of fan speed (5000 rpm; 7000 rpm; and 9000 rpm) for cooling air flow were considered. A numerical simulation of heat transfer was performed using the ANSYS Fluent software. The electrochemical modelling of a battery was developed based on the NTGK approach, and the phase-change phenomenon was treated as an enthesis–porosity problem. The composite PCM, aluminum metal foam embedded in n-octadecane, had better heat dissipation performance than forced air convection. The PCM is significantly more effective at heat dissipation than forced air. Interestingly, when using a hybrid cooling system that combines forced air and a PCM, although it meets the operational requirements for Li-ion batteries in regard to maximum temperature and temperature uniformity at a 3C discharge rate, the airflow appears to have a negligible effect on thermal management and yields an indiscernible change in temperature. This can be attributed to a complex flow pattern that developed in a casing as a result of the suboptimal design of the inlet and outlet. Further studies will be required for the optimal positioning of the inlet and outlet, as well as the effectiveness of combining liquid cooling methods.
- Open Access
One-Dimensional and Three-Dimensional Numerical Investigations of Thermal Performance of Phase Change Materials in a Lithium-Ion Battery
The thermal performance of a large-format (52.3 Ah) Li-ion pouch battery with an n-octadecane PCM was investigated. A simplified 1D model was employed to estimate the transient thermal behavior. Two design parameters, the thickness and the thermal conductivity of the PCM, were considered. A 0.5 mm thick n-octadecane PCM integrated with aluminum foam reduced the battery temperature to 34.3 °C and 50.7 °C at the end stage of discharging under 3C and 5C discharge rates, respectively. The 1D results compared to the 3D results were able to predict the temperature dissipation by the PCM method at the end of discharging. The 1D approach clearly produced reliable results in predicting the thermal behavior of the PCM cooling and was superior in practical applications with its low cost and time consumption. A 3D CFD simulation was able to describe the detailed temperature uniformity in the cell, which is an important factor in the design and evaluation of a battery cooling system.
Open AccessOne-Dimensional and Three-Dimensional Numerical Investigations of Thermal Performance of Phase Change Materials in a Lithium-Ion Battery
The thermal performance of a large-format (52.3 Ah) Li-ion pouch battery with an n-octadecane PCM was investigated. A simplified 1D model was employed to estimate the transient thermal behavior. Two design parameters, the thickness and the thermal conductivity of the PCM, were considered. A 0.5 mm thick n-octadecane PCM integrated with aluminum foam reduced the battery temperature to 34.3 °C and 50.7 °C at the end stage of discharging under 3C and 5C discharge rates, respectively. The 1D results compared to the 3D results were able to predict the temperature dissipation by the PCM method at the end of discharging. The 1D approach clearly produced reliable results in predicting the thermal behavior of the PCM cooling and was superior in practical applications with its low cost and time consumption. A 3D CFD simulation was able to describe the detailed temperature uniformity in the cell, which is an important factor in the design and evaluation of a battery cooling system.