JCJing Chen

Jing Chen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jing Chen has a total of 31 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • A Wearable Sensor-Driven Monitoring Framework for Hypoxic Respiratory Key Parameters Using Sensitivity-Based Estimation

    by Meitong Li, Jing Chen, Dawei Shi, Shiyue Jia, Lingling Zhu

    Wearable sensors provide continuous physiological measurements, such as $\text{SpO}_{2}$ and heart rate. However, in hypoxic respiratory applications, such sensors primarily monitor superficial symptoms, while the key underlying parameters remain nonmeasurable. To address this issue, this work proposes a process monitoring framework driven by a novel sensitivity-based parameter estimation approach. The framework utilizes a physics-informed model with 18 key parameters as the monitoring target, where the change in two critical parameters is used to assess the hypoxic adaptation index (HAI). The estimation method incorporates a sensitivity-based groupwise optimization and an identifiability-based collective variational inference, which assigns greater trust weights to high-quality signals to mitigate the impact of low-quality data. Monitoring effectiveness is validated via an in silico experiment, which demonstrates normalized mean absolute error reductions of 3.28% (individual) and 4.30% (population) over the baseline. The robustness of the framework and the effectiveness of the HAI are subsequently confirmed in a real-world intermittent hypoxic training experiment that involved noisy sensor data from 19 human subjects. This work provides a robust and generalizable framework for monitoring nonmeasurable key parameters in other complex dynamic systems.

  • Few-Shot Personalized Blood Pressure Estimation from Photoplethysmography and Physiological Priors via Low-Rank Adaptation

    by Meitong Li, Jing Chen, Dawei Shi, Yuanting Zhang, Xiao Wang

    Noninvasive continuous blood pressure (BP) monitoring has become a critical requirement for effective health management in the general population. To address the challenge of accurate few-shot personalized BP estimation, a photoplethysmography (PPG)-based framework built on the unified multi-task time series model with a Transformer backbone is proposed. The framework comprises population-level pretraining and personalized fine tuning with a pulse pressure segmented penalty (PPSP) loss. The PPSP couples systolic BP (SBP) and diastolic BP (DBP) outputs by penalizing pulse pressure values outside clinically accepted ranges, which enforces physiological consistency. In addition, a sampling-rate-robust low-rank adaptation (SRR-LoRA) is introduced to improve estimation accuracy when low-frequency PPG signals are employed. After rate alignment, SRR-LoRA prioritizes measurements over interpolated points, suppresses interpolation noise, and preserves cross-device generalization. Model performance was evaluated on the UCI cuffless BP estimation dataset, the University of Queensland vital signs dataset, and the CAS-BP dataset. 113,812 samples from 2,405 subjects were used for pretraining, and data from 316 subjects (each with 50 samples) were included for few-shot fine tuning. The proposed method achieved mean absolute errors of 1.52/1.07 mmHg for SBP/DBP. These results fulfill the Association for the Advancement of Medical Instrumentation BP standard and correspond to Grade A performance according to the British Hypertension Society standard and IEEE 1708 standard, which demonstrates the framework's potential for practical personalized wearable BP monitoring.

  • Physiology-informed Gaussian process meta-learning for postprandial glucose trajectory prediction

    by Jing Chen, Deheng Cai, Dawei Shi, Ling Shi, Wei Liu, Linong Ji

    Advanced wearable sensors have enabled the continuous monitoring of physiological data under the Internet of Medical Things framework, which promotes the development of intelligent prediction technology for healthcare applications. This work concerns the problem of interpretable personalized blood glucose (BG) prediction that is crucial for diabetes management. Although encouraging results of machine learning methods have been shown in short-term prediction, the lack of interpretability of the “black-box” models obtained by using limited clinical data reduces the acceptance for practical use, especially for long-term postprandial BG prediction. To address this problem, a physiology-informed Gaussian process model with a neural mean function is proposed, in which the prior knowledge of glycometabolism is incorporated into the model optimization process to guarantee interpretable model learning and strengthen the ability of capturing key glucose dynamics. Besides, a model-agnostic meta-learning is utilized to enhance the model adaptability for personalized prediction. The effectiveness of the proposed method is evaluated through the comparative results obtained by using the FDA-accepted UVA/Padova T1DM simulator and the clinical datasets. Among all the considered approaches, the proposed approach achieved the lowest RMSE on the in silico dataset, as well as in 3h and 4h prediction on the clinical dataset. These results indicate that the proposed method has superior performance in predicting long-term postprandial BG trajectories.

  • Kernel-Based Learning With Adaptive Physiological Constraints for Personalized Postprandial Glucose Prediction

    by Suhao Feng, Deheng Cai, Jing Chen, Dawei Shi, Ling Shi, Wei Liu, Linong Ji

    Accurate and physiologically interpretable postprandial glucose prediction is of importance in diabetes self-management. In this work, the problem of personalized glucose prediction is considered, and an interpretable postprandial glucose trajectory prediction framework is proposed based on kernel-based system identification under physiological constraints. Considering treatment requirements in inpatient scenarios, an online prediction update mechanism is developed to deal with intrasubject variability. Through incorporating physiological constraints abstracted from linearized compartmental models, a posterior performance assessment and adaptation mechanism is designed to guarantee the interpretability of the predicted glucose responses. The proposed method is evaluated through clinical data from type 1 diabetes mellitus (T1DM) subjects, and the results indicate that the proposed method can achieve physiologically interpretable postprandial glucose trajectory prediction with satisfactory performance.

  • A Switched Neural Process for Long-Term Postprandial Glucose Trajectory Prediction Based on Insulin Sensitivity Estimation

    by Jing Chen, Dawei Shi, Deheng Cai, Wei Liu, Linong Ji, Ling Shi

    Advanced sensing technology has enabled the real-time monitoring of blood glucose (BG), making it possible to explore the BG prediction problem based on continuous observations. In this work, we propose a novel switched neural process (NP) approach for long-term postprandial BG prediction, which has the probabilistic inference ability conditioned on preprandial BG measurements. Distinct representative NP models are constructed to capture the nonlinear BG dynamics based on a designed indicator. This indicator is developed to estimate insulin sensitivity (IS) at meal time by using physiological models, in which the effect of preprandial BG variation on IS estimation is evaluated. Besides, a robust model switching mechanism is designed to determine the appropriate NP model for prediction. The effectiveness of the proposed method is illustrated through the comparative results by using both the in silico data from the US Food and Drug Administration (FDA)-accepted UVA/Padova type 1 diabetes mellitus (T1DM) simulator and the clinical data from 47 T1DM subjects. The obtained results indicate that the proposed method outperforms existing methods especially for 3h and 4h prediction, which shows promising potential in predicting postprandial BG levels.

  • Unveiling Interpretable Key Performance Indicators in Hypoxic Response: A System Identification Approach

    by Jing Chen, Rong Xiao, Lei Wang, Lingling Zhu, Dawei Shi

    Advances in wireless networks and wearable electronic devices have enabled the monitoring of massive physiological data for disease diagnosis. In this article, we aim to explore the hypoxic response dynamics through the use of system identification based on physiological data monitored by wearable devices. A third-order autoregressive moving average with exogenous inputs model is developed to describe the dominant system dynamics, based on which an interpretable index called “sum of distance” (SoD) is proposed from a systems and control perspective for AMS risk evaluation. The effectiveness of SoD is evaluated on the basis of physiological data from a proof-of-the-concept study. Statistically, significant relationships of DSI with ground truth AMS metrics (including, Lake Louise score, deep sleep duration, and deep sleep ratio) are observed. To accelerate the evaluation algorithm design, a simulator is designed. A model parameter selection method based on the three-sigma rule is proposed to generate an in silico population, and a total disturbance sequence is determined for disturbance simulation. The created data has the same trend as the real measurements. The proposed method and experimental results indicate the feasibility of improving the AMS risk evaluation performance by understanding and learning the hypoxic response mechanism.


  • IoT-Enabled Intelligent Dynamic Risk Assessment of Acute Mountain Sickness: The Role of Event-Triggered Signal Processing

    by Jing Chen, Yuan Tian, Guangbo Zhang, Zhengtao Cao, Lingling Zhu, Dawei Shi

    The rapid developments in Internet of Medical Things open up new avenues for personalized healthcare. Continuously monitored physiological data can be collected by wearable devices and are transmitted to a remote server for real-time monitoring and diagnosis. This article concerns a risk assessment problem of acute mountain sickness (AMS) with data transmitted according to an event-triggered transmission schedule. An event-triggered signal processing approach is introduced to reconstruct the untransmitted information, based on which, a dynamic SpO $_{\bf 2}$ index (DSI) is further proposed for AMS risk evaluation. The performance of the proposed approach is analyzed through physiological data collected in a proof-of-the-concept study ( N =12). Statistical significant correlation of the DSI with AMS ground truth including Lake Louise score, deep sleep duration, deep sleep ratio, and mean SpO $_{\bf 2}$ during sleep is observed. More importantly, it is observed that the proposed event-triggered signal processing procedure can dramatically reduce the data transmission rate while maintaining the performance of the DSI assessment, through comparison of the DSI obtained using the proposed event-triggered approach with those obtained based on event-triggered raw data and continuously transmitted time-triggered data. The obtained results indicate the feasibility of adopting event-triggered data scheduling and signal processing to achieve AMS risk evaluation using data from wearable devices with limited communication/battery resources.


  • A Time Series Prediction Model Based on Long Short-Term Memory Networks

    by Linkai Wang, Jing Chen, Wei Wang, Ruofan Wang, Lina Yang, Mai An

    Since real time series are usually divided into cyclical and non-cyclical features, the traditional Auto Regressive Integrated Moving Average (ARIMA) model often shows certain limitations in the modeling of cyclical time series. In this regard, Long Short-Term Memory (LSTM) networks are introduced to predict periodic time series, and missing values are filled by linear interpolation to improve data integrity. The time series are divided into sliding windows according to the period, and the data of the number of people getting on and off the bus in Sino-Singapore Tianjin Eco-City is used as a sample to train and test the model. The test results show that the average absolute error (MAE) of the LSTM model is 80.246, and the root mean square error (RMSE) is 108.52, which is 91.24 and 89.75 lower than the Gated Recurrent Unit (GRU) model, and 83.03 and 104.56 lower than the ARIMA model. The goodness of fit of the LSTM model is 0.902, which is 0.281 and 0.168 higher than that of the ARIMA model and the GRU model, respectively.


  • Open Access

    Modification and Validation of the Phosphate Removal Model: A Multicenter Study

    by Weichen Zhang, Qiuna Du, Jing Xiao, Zhaori Bi, Chen Yu, Zhibin Ye, Mengjing Wang, Jing Chen

    Background: Our research group has previously reported a noninvasive model that estimates phosphate removal within a 4-h hemodialysis (HD) treatment. The aim of this study was to modify the original model and validate the accuracy of the new model of phosphate removal for HD and hemodiafiltration (HDF) treatment. Methods: A total of 109 HD patients from 3 HD centers were enrolled. The actual phosphate removal amount was calculated using the area under the dialysate phosphate concentration time curve. Model modification was executed using second-order multivariable polynomial regression analysis to obtain a new parameter for dialyzer phosphate clearance. Bias, precision, and accuracy were measured in the internal and external validation to determine the performance of the modified model. Results: Mean age of the enrolled patients was 63 ± 12 years, and 67 (61.5%) were male. Phosphate removal was 19.06 ± 8.12 mmol and 17.38 ± 6.75 mmol in 4-h HD and HDF treatments, respectively, with no significant difference. The modified phosphate removal model was expressed as Tpo4 = 80.3 × C45 − 0.024 × age + 0.07 × weight + β × clearance − 8.14 (β = 6.231 × 10−3 × clearance − 1.886 × 10−5 × clearance2 – 0.467), where C45 was the phosphate concentration in the spent dialysate measured at the 45th minute of HD and clearance was the phosphate clearance of the dialyzer. Internal validation indicated that the new model was superior to the original model with a significantly smaller bias and higher accuracy. External validation showed that R2, bias, and accuracy were not significantly different than those of internal validation. Conclusions: A new model was generated to quantify phosphate removal by 4-h HD and HDF with a dialyzer surface area of 1.3–1.8 m2. This modified model would contribute to the evaluation of phosphate balance and individualized therapy of hyperphosphatemia.