Haibin Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haibin Wang has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
Bo Jiang
Department of Otorhinolaryngology, Affiliated Hangzhou First People’s Hospital, Zhejiang University School of Medicine, Hangzhou, China
1 shared publicationChang Shao
Department of Pathology, Affiliated Hangzhou First People’s Hospital, Zhejiang University School of Medicine, Hangzhou, People’s Republic of China
1 shared publication- Hongjie Hu
Department of Radiology, Sir Run Run Shaw Hospital, Zhejiang University School of Medicine, Hangzhou, China
1 shared publication - Jian Wu
Department of Pathology, Affiliated Hangzhou First People’s Hospital, Zhejiang University School of Medicine, Hangzhou, China
1 shared publication - Jianguang Zhong
Department of Otorhinolaryngology, Affiliated Hangzhou First People’s Hospital, Zhejiang University School of Medicine, Hangzhou, China
1 shared publication - Li Jiang
Department of Neurosurgery, Affiliated Hangzhou First People’s Hospital, Zhejiang University School of Medicine, Hangzhou, China
1 shared publication
Latest Publications
- Open Access
- 13 December 2021
- Published by SAGE Publications in Ear, Nose & Throat Journal
- Vol. 103 (7) , 420-423
Orbital schwannoma with hyposmia as the only presentation: Case report and a literature review on differential diagnosis
Orbital schwannoma is a rare benign tumor, originating from the Schwann cells of the orbital peripheral nerve sheath. Orbital schwannoma is easily misdiagnosed if the patient shows atypical presentations and atypical appearance on MRI imaging. A 56-year-old male experienced hyposmia for 1 year and was misdiagnosed with cavernous hemangioma pre-operation. This case was treated by surgery through the endoscopic trans-nasal approach. After operation, the patient had no recurrence or complications. Preoperative diagnosis for these cases remains difficult. Combined imaging modalities including computed tomography (CT) and magnetic resonance imaging (MRI) can help in differential diagnosis. Surgery is the main treatment modality for treating orbital schwannoma. Outcomes in most cases are favorable without complications or recurrence.
- 13 December 2021
- Published by SAGE Publications in Ear, Nose & Throat Journal
- Vol. 103 (7) , 420-423
Open AccessOrbital schwannoma with hyposmia as the only presentation: Case report and a literature review on differential diagnosis
Orbital schwannoma is a rare benign tumor, originating from the Schwann cells of the orbital peripheral nerve sheath. Orbital schwannoma is easily misdiagnosed if the patient shows atypical presentations and atypical appearance on MRI imaging. A 56-year-old male experienced hyposmia for 1 year and was misdiagnosed with cavernous hemangioma pre-operation. This case was treated by surgery through the endoscopic trans-nasal approach. After operation, the patient had no recurrence or complications. Preoperative diagnosis for these cases remains difficult. Combined imaging modalities including computed tomography (CT) and magnetic resonance imaging (MRI) can help in differential diagnosis. Surgery is the main treatment modality for treating orbital schwannoma. Outcomes in most cases are favorable without complications or recurrence.
- Open Access
- 1 July 2021
- Published by Taylor & Francis in Cancer Management and Research
- Vol. ume 13, 5423-5431
Quantitative Analysis and Pathological Basis of Signal Intensity on T2-Weighted MR Images in Benign and Malignant Parotid Tumors
Objective: To investigate the value of the signal intensity on T2-weighted magnetic resonance (MR) imaging using quantitative analysis in the differentiation of parotid tumors. Materials and Methods: MR data of 80 pleomorphic adenomas (PAs), 68 Warthin tumors (WTs), and 34 malignant tumors (MTs) confirmed by surgery and histology were retrospectively analyzed. The signal intensities of tumor, normal parotid gland, spinal cord, and buccal subcutaneous fat were measured, and the signal intensity ratios (SIRs) between the tumor and the three references were calculated. Receiver operating characteristic curve was used to determine the optimal threshold and diagnostic efficiency of SIR for differentiating PAs, WTs, and MTs. Results: The area under the curve (AUC) of tumor to parotid gland SIR (SIRP), tumor to spinal cord SIR (SIRC), and tumor to buccal subcutaneous fat SIR (SIRF) for differentiating PAs and WTs was 0.922, 0.918, and 0.934, respectively. The sensitivity and specificity at an optimal SIR threshold were 86.3% and 91.2%, 80.0% and 97.1%, and 85.0% and 94.1%, respectively. The AUC of SIRP, SIRC, and SIRF for distinguishing PAs from MTs was 0.793, 0.802, and 0.774, respectively. The sensitivity and specificity at an optimal SIR threshold was 86.3% and 61.8%, 80.0% and 73.5%, and 82.5% and 73.5%, respectively. The AUC of SIRP, SIRC, and SIRF for distinguishing WTs from MTs was 0.716, 0.709, and 0.759, respectively. The sensitivity and specificity at an optimal SIR threshold were 61.8% and 82.4%, 55.9% and 82.4%, and 64.7% and 86.8%, respectively. Conclusion: SIRP, SIRC, and SIRF on T2-weighted MR images had high diagnostic efficiency for differentiating between PAs and WTs, while SIRP and SIRC for differentiating between PAs and MTs, and SIRF for differentiating between WTs and MTs had relatively high diagnostic efficiency.
- 1 July 2021
- Published by Taylor & Francis in Cancer Management and Research
- Vol. ume 13, 5423-5431
Open AccessQuantitative Analysis and Pathological Basis of Signal Intensity on T2-Weighted MR Images in Benign and Malignant Parotid Tumors
Objective: To investigate the value of the signal intensity on T2-weighted magnetic resonance (MR) imaging using quantitative analysis in the differentiation of parotid tumors. Materials and Methods: MR data of 80 pleomorphic adenomas (PAs), 68 Warthin tumors (WTs), and 34 malignant tumors (MTs) confirmed by surgery and histology were retrospectively analyzed. The signal intensities of tumor, normal parotid gland, spinal cord, and buccal subcutaneous fat were measured, and the signal intensity ratios (SIRs) between the tumor and the three references were calculated. Receiver operating characteristic curve was used to determine the optimal threshold and diagnostic efficiency of SIR for differentiating PAs, WTs, and MTs. Results: The area under the curve (AUC) of tumor to parotid gland SIR (SIRP), tumor to spinal cord SIR (SIRC), and tumor to buccal subcutaneous fat SIR (SIRF) for differentiating PAs and WTs was 0.922, 0.918, and 0.934, respectively. The sensitivity and specificity at an optimal SIR threshold were 86.3% and 91.2%, 80.0% and 97.1%, and 85.0% and 94.1%, respectively. The AUC of SIRP, SIRC, and SIRF for distinguishing PAs from MTs was 0.793, 0.802, and 0.774, respectively. The sensitivity and specificity at an optimal SIR threshold was 86.3% and 61.8%, 80.0% and 73.5%, and 82.5% and 73.5%, respectively. The AUC of SIRP, SIRC, and SIRF for distinguishing WTs from MTs was 0.716, 0.709, and 0.759, respectively. The sensitivity and specificity at an optimal SIR threshold were 61.8% and 82.4%, 55.9% and 82.4%, and 64.7% and 86.8%, respectively. Conclusion: SIRP, SIRC, and SIRF on T2-weighted MR images had high diagnostic efficiency for differentiating between PAs and WTs, while SIRP and SIRC for differentiating between PAs and MTs, and SIRF for differentiating between WTs and MTs had relatively high diagnostic efficiency.