Haiwei Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Haiwei Dong has a total of 16 co-authors. Here are the top co-authors by number of shared publications:
- Jiangying Chen
Key Laboratory of Impact and Safety Engineering (Ningbo University), Ministry of Education, Ningbo, China
3 shared publications - Yi Li
Key Laboratory of Impact and Safety Engineering, Ningbo University, Ministry of Education, Ningbo 315211, China
2 shared publications Aiguo Jin
1 shared publicationBohan Ma
Engineering Research Center of Industrial Construction in Civil Engineering of Zhejiang Province, Ningbo University of Technology, Ningbo, China
1 shared publication- Chaoming Shi
Key Laboratory of Impact and Safety Engineering, Ningbo University, Ministry of Education, Ningbo 315211, China
1 shared publication Heng Yang
1 shared publication
Latest Publications
- 27 November 2025
- Published by Elsevier in Mechanics Research Communications
- Vol. 151
Mechanical-electric response characteristics of 2–2 UHPC based piezoelectric composite under impact loading
- 27 November 2025
- Published by Elsevier in Mechanics Research Communications
- Vol. 151
Mechanical-electric response characteristics of 2–2 UHPC based piezoelectric composite under impact loading
- 29 December 2023
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 35 (4) , 370-379
Experimentation and simulation study of electromechanical response characteristics of a 2-2 type cement-based piezoelectric composite sensor
In the manuscript, the piezoelectric functional element was prepared by slicing and adding method using piezoelectric ceramic PZT-5H and ordinary silicate cement 42.5 was as base materials, and then a 2-2 type cement-based piezoelectric composite sensor was prepared by an encapsulated epoxy resin. The experimental and simulation analysis was carried out to obtain the quasi-static linear sensitivity of the electromechanical response of the sample under conditions of compressive loading. The development process of the sample from local failure to overall fragmentation was observed using a high-speed camera. Found that the electrical nonlinear threshold of 35 MPa appeared before the mechanical nonlinear threshold. Further, the results showed that when the loading frequency was increased from 5 to 15 Hz under equal amplitude, the response waveform remained unchanged, however, the electrical displacement was attenuated by 19.7%. Packaging schemes using various lengths and thicknesses of an epoxy layer were conducted by using simulation. It is indicated that, under the premise of ensuring the protection package and considering the manufacturing process, the length of the package side could increase appropriately, and the single-side package side length is set to 4 mm. When the thickness of the package layer becomes less, it would be better.
- 29 December 2023
- Published by SAGE Publications in Journal of Intelligent Material Systems and Structures
- Vol. 35 (4) , 370-379
Experimentation and simulation study of electromechanical response characteristics of a 2-2 type cement-based piezoelectric composite sensor
In the manuscript, the piezoelectric functional element was prepared by slicing and adding method using piezoelectric ceramic PZT-5H and ordinary silicate cement 42.5 was as base materials, and then a 2-2 type cement-based piezoelectric composite sensor was prepared by an encapsulated epoxy resin. The experimental and simulation analysis was carried out to obtain the quasi-static linear sensitivity of the electromechanical response of the sample under conditions of compressive loading. The development process of the sample from local failure to overall fragmentation was observed using a high-speed camera. Found that the electrical nonlinear threshold of 35 MPa appeared before the mechanical nonlinear threshold. Further, the results showed that when the loading frequency was increased from 5 to 15 Hz under equal amplitude, the response waveform remained unchanged, however, the electrical displacement was attenuated by 19.7%. Packaging schemes using various lengths and thicknesses of an epoxy layer were conducted by using simulation. It is indicated that, under the premise of ensuring the protection package and considering the manufacturing process, the length of the package side could increase appropriately, and the single-side package side length is set to 4 mm. When the thickness of the package layer becomes less, it would be better.
- Open Access
Construction of 2-2 Type Cement-Based Piezoelectric Composites’ Mechanic–Electric Relationship Based on Strain Rate Dependence
It has been found that the mechanic–electric response of cement-based piezoelectric composites under impact loading is nonlinear. Herein, we prepared a 2-2 cement-based piezoelectric composite material using cutting, pouring, and re-cutting. Then, we obtained the stress–strain and stress–electric displacement curves for this piezoelectric composite under impact loading using a modified split Hopkinson pressure bar (SHPB) experimental apparatus and an additional electrical output measurement system. Based on the micromechanics of the composite materials, we assumed that damage occurred only in the cement paste. The mechanical response relationship of the piezoelectric composite was calculated as the product of the viscoelastic constitutive relationship of the cement paste and a constant, where the constant was determined based on the reinforcement properties of the mechanical response of the piezoelectric composite. Using a modified nonlinear viscoelastic Zhu–Wang–Tang (ZWT) model, we characterized the stress–strain curves of the piezoelectric composite with different strain rates. The dynamic sensitivity and stress threshold of the linear response of the samples were calibrated and fitted. Thus, a mechanic–electric response equation was established for the 2-2 type cement-based piezoelectric composite considering the strain rate effects.
Open AccessConstruction of 2-2 Type Cement-Based Piezoelectric Composites’ Mechanic–Electric Relationship Based on Strain Rate Dependence
It has been found that the mechanic–electric response of cement-based piezoelectric composites under impact loading is nonlinear. Herein, we prepared a 2-2 cement-based piezoelectric composite material using cutting, pouring, and re-cutting. Then, we obtained the stress–strain and stress–electric displacement curves for this piezoelectric composite under impact loading using a modified split Hopkinson pressure bar (SHPB) experimental apparatus and an additional electrical output measurement system. Based on the micromechanics of the composite materials, we assumed that damage occurred only in the cement paste. The mechanical response relationship of the piezoelectric composite was calculated as the product of the viscoelastic constitutive relationship of the cement paste and a constant, where the constant was determined based on the reinforcement properties of the mechanical response of the piezoelectric composite. Using a modified nonlinear viscoelastic Zhu–Wang–Tang (ZWT) model, we characterized the stress–strain curves of the piezoelectric composite with different strain rates. The dynamic sensitivity and stress threshold of the linear response of the samples were calibrated and fitted. Thus, a mechanic–electric response equation was established for the 2-2 type cement-based piezoelectric composite considering the strain rate effects.
- Open Access
- 15 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (24) , 11925
Dynamic Response of Electro-Mechanical Properties of Cement-Based Piezoelectric Composites
By employing ordinary Portland cement as a matrix and PZT-5H piezoelectric ceramic as the functional body, 1-3 and 2-2 cement-based piezoelectric composites were prepared. Quasi-static compression tests were performed along with dynamic impact loading tests to study the electro-mechanical response characteristics of 1-3 and 2-2 cement-based piezoelectric composites. The research results show that both composites exhibit strain rate effects under quasi-static compression and dynamic impact loading since they are strain-rate sensitive materials. The sensitivity of the two composites has a non-linear mutation point: in the quasi-static state, the sensitivity of 1-3 and 2-2 composites is 157 and 169 pC/N, respectively; in the dynamic state, the respective sensitivity is 323 and 296 pC/N. Although the sensitivity difference is not significant, the linear range of the 2-2 composite is 24.8% and 61.3% larger than that of the 1-3 composite under quasi-static compression and dynamic impact loading, respectively. Accordingly, the 2-2 composite exhibits certain advantages as a sensor material, irrespective of whether it is subjected to quasi-static or dynamic loading.
- 15 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (24) , 11925
Open AccessDynamic Response of Electro-Mechanical Properties of Cement-Based Piezoelectric Composites
By employing ordinary Portland cement as a matrix and PZT-5H piezoelectric ceramic as the functional body, 1-3 and 2-2 cement-based piezoelectric composites were prepared. Quasi-static compression tests were performed along with dynamic impact loading tests to study the electro-mechanical response characteristics of 1-3 and 2-2 cement-based piezoelectric composites. The research results show that both composites exhibit strain rate effects under quasi-static compression and dynamic impact loading since they are strain-rate sensitive materials. The sensitivity of the two composites has a non-linear mutation point: in the quasi-static state, the sensitivity of 1-3 and 2-2 composites is 157 and 169 pC/N, respectively; in the dynamic state, the respective sensitivity is 323 and 296 pC/N. Although the sensitivity difference is not significant, the linear range of the 2-2 composite is 24.8% and 61.3% larger than that of the 1-3 composite under quasi-static compression and dynamic impact loading, respectively. Accordingly, the 2-2 composite exhibits certain advantages as a sensor material, irrespective of whether it is subjected to quasi-static or dynamic loading.