Jidong Weng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jidong Weng has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Chengjun Li
National Key Laboratory of Shock Wave and Detonation Physics, Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China
10 shared publications - Jian Wu
National Key Laboratory of Shock Wave and Detonation Physics, Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China
10 shared publications - Longhuang Tang
National Key Laboratory of Shock Wave and Detonation Physics, Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang, China
10 shared publications - Shenggang Liu
National Key Laboratory of Shock Wave and Detonation Physics, Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China
10 shared publications - Tianjiong Tao
National Key Laboratory of Shock Wave and Detonation Physics, Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China
10 shared publications - Xiang Wang
National Key Laboratory of Shock Wave and Detonation Physics, Institute of Fluid Physics, China Academy of Engineering Physics, Mianyang 621900, China
10 shared publications
Latest Publications
- Open Access
High-Update-Rate (25 kHz) Laser Ranging with Random Noise Modulation for Fast and Precise Absolute Distance Measurement
This paper proposes a technique for precise distance measurement under laser random noise using autocorrelation demodulation. We conducted measurements within a 2 m range using a commercial digitizer with a sampling rate of 40 GS/s. The single signal acquisition time is 40 μs, and the measurement results achieved an accuracy of 30 μm and a standard deviation (SD) of 8 μm. This method can also improve measurement accuracy by increasing the sampling rate and expanding the measurement range by extending the duration of a single sampling.
Open AccessHigh-Update-Rate (25 kHz) Laser Ranging with Random Noise Modulation for Fast and Precise Absolute Distance Measurement
This paper proposes a technique for precise distance measurement under laser random noise using autocorrelation demodulation. We conducted measurements within a 2 m range using a commercial digitizer with a sampling rate of 40 GS/s. The single signal acquisition time is 40 μs, and the measurement results achieved an accuracy of 30 μm and a standard deviation (SD) of 8 μm. This method can also improve measurement accuracy by increasing the sampling rate and expanding the measurement range by extending the duration of a single sampling.
- Open Access
- 24 April 2025
- Published by MDPI AG in Electronics
- Vol. 14 (9) , 1732
Application of Highly Spatially Resolved Area Array Velocity Measurement in the Cracking Behavior of Materials
Understanding microscale dynamic behavior in heterogeneous materials (e.g., polycrystalline or semiconductor systems) under impact loading requires diagnostics capable of resolving ~100 μm features. This study introduces a 19-core fiber-optic array probe with 100 μm spatial resolution, integrated with DISAR velocimetry on a light gas gun platform, enabling two-dimensional continuous measurement of free-surface velocity. The system overcomes limitations of conventional single-point methods (e.g., VISAR’s millimeter-scale resolution and reflectivity constraints) by achieving nanosecond temporal resolution and sub-nanometer displacement sensitivity. Under ~8 GPa impact loading, the probe captures spatiotemporal velocity heterogeneity in polycrystalline materials, including localized pull-back signals and periodic oscillations caused by shock wave reflections at microstructural interfaces. These observations reveal dynamic processes such as damage initiation and evolution, directly linking velocity profiles to microscale material response. The results provide experimental evidence of how grain-scale defects influence shock propagation and energy dissipation, advancing predictive models for extreme-condition material performance. This high-resolution, multi-channel approach offers a paradigm shift in diagnosing heterogeneous material behavior under high-strain-rate loading.
- 24 April 2025
- Published by MDPI AG in Electronics
- Vol. 14 (9) , 1732
Open AccessApplication of Highly Spatially Resolved Area Array Velocity Measurement in the Cracking Behavior of Materials
Understanding microscale dynamic behavior in heterogeneous materials (e.g., polycrystalline or semiconductor systems) under impact loading requires diagnostics capable of resolving ~100 μm features. This study introduces a 19-core fiber-optic array probe with 100 μm spatial resolution, integrated with DISAR velocimetry on a light gas gun platform, enabling two-dimensional continuous measurement of free-surface velocity. The system overcomes limitations of conventional single-point methods (e.g., VISAR’s millimeter-scale resolution and reflectivity constraints) by achieving nanosecond temporal resolution and sub-nanometer displacement sensitivity. Under ~8 GPa impact loading, the probe captures spatiotemporal velocity heterogeneity in polycrystalline materials, including localized pull-back signals and periodic oscillations caused by shock wave reflections at microstructural interfaces. These observations reveal dynamic processes such as damage initiation and evolution, directly linking velocity profiles to microscale material response. The results provide experimental evidence of how grain-scale defects influence shock propagation and energy dissipation, advancing predictive models for extreme-condition material performance. This high-resolution, multi-channel approach offers a paradigm shift in diagnosing heterogeneous material behavior under high-strain-rate loading.
- Open Access
- 5 March 2025
- Published by MDPI AG in Preprints.org
Application of High Spatially Resolved Areal Array Velocity Measurement in the Cracking Behavior of Materials
The dynamic behavior of heterogeneous materials, such as semiconductor materials, under impact loading is one of the experimental studies to improve the material properties. However, the non-uniformity of the material, such as grains and defects, is around 100 microns, which requires high-spatially resolved and high-dimensional measurement methods. In this paper, an area array fiber optic probe with 100-micron spatial resolution is designed, and the two-dimensional continuous measurement of the free surface velocity of heterogeneous materials is realized on the light gas gun platform with DISAR velocimetry technology. The dynamic behavior change process under different positions is obtained, which provides experimental data for the study of the impact response of polycrystalline materials.
- 5 March 2025
- Published by MDPI AG in Preprints.org
Open AccessApplication of High Spatially Resolved Areal Array Velocity Measurement in the Cracking Behavior of Materials
The dynamic behavior of heterogeneous materials, such as semiconductor materials, under impact loading is one of the experimental studies to improve the material properties. However, the non-uniformity of the material, such as grains and defects, is around 100 microns, which requires high-spatially resolved and high-dimensional measurement methods. In this paper, an area array fiber optic probe with 100-micron spatial resolution is designed, and the two-dimensional continuous measurement of the free surface velocity of heterogeneous materials is realized on the light gas gun platform with DISAR velocimetry technology. The dynamic behavior change process under different positions is obtained, which provides experimental data for the study of the impact response of polycrystalline materials.
- Open Access
A Submicrosecond-Response Ultrafast Microwave Ranging Method Based on Optically Generated Frequency-Modulated Pulses
An ultrafast microwave ranging method based on optically generated frequency-modulated microwave pulses is proposed in this study. The theoretical analysis demonstrated that nanosecond-scale linear frequency modulation microwave pulse can be obtained by femtosecond laser interference under the condition of unbalanced dispersion, which can be used to achieve a high temporal resolution of the displacement change in the measurement by the principle of frequency modulation continuous wave (FMCW) radar. The proof-of-principle experiment successfully measured the displacement change with an error of 2.5 mm and a range of 0.6 m, with a response time of 468 ns. Compared to existing microwave ranging technologies, the temporal resolution was improved by two orders of magnitude, which greatly improves the temporal resolution of distance measurement in the field of microwave FMCW radar.
Open AccessA Submicrosecond-Response Ultrafast Microwave Ranging Method Based on Optically Generated Frequency-Modulated Pulses
An ultrafast microwave ranging method based on optically generated frequency-modulated microwave pulses is proposed in this study. The theoretical analysis demonstrated that nanosecond-scale linear frequency modulation microwave pulse can be obtained by femtosecond laser interference under the condition of unbalanced dispersion, which can be used to achieve a high temporal resolution of the displacement change in the measurement by the principle of frequency modulation continuous wave (FMCW) radar. The proof-of-principle experiment successfully measured the displacement change with an error of 2.5 mm and a range of 0.6 m, with a response time of 468 ns. Compared to existing microwave ranging technologies, the temporal resolution was improved by two orders of magnitude, which greatly improves the temporal resolution of distance measurement in the field of microwave FMCW radar.
- Open Access
- 21 November 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (23) , 10771
Measurement of Ultra-High Speed by Optical Multistage Cascade Frequency Reduction Technology
In order to reduce the frequency of high-frequency Doppler signal light, the electronic bandwidth of a data acquisition system is reduced. This paper mainly describes the principle and experimental verification results of optical multistage cascade frequency reduction technology. The bandwidth requirement of the detector and the oscilloscope is reduced by the method of “relaying” the measured beat frequency signal between multiple electronic channels. Aiming to achieve the requirement of ultra-high speed measurement of 22 km/s, the requirement of the original signal frequency as high as 28 GHz electrical bandwidth is reduced to the acquisition and recording system with only 8 GHz bandwidth. A complete velocity profile of up to 11.47 km/s is measured on a three-stage light gas gun with velocity measurement accuracy of 1%.
- 21 November 2024
- Published by MDPI AG in Applied Sciences
- Vol. 14 (23) , 10771
Open AccessMeasurement of Ultra-High Speed by Optical Multistage Cascade Frequency Reduction Technology
In order to reduce the frequency of high-frequency Doppler signal light, the electronic bandwidth of a data acquisition system is reduced. This paper mainly describes the principle and experimental verification results of optical multistage cascade frequency reduction technology. The bandwidth requirement of the detector and the oscilloscope is reduced by the method of “relaying” the measured beat frequency signal between multiple electronic channels. Aiming to achieve the requirement of ultra-high speed measurement of 22 km/s, the requirement of the original signal frequency as high as 28 GHz electrical bandwidth is reduced to the acquisition and recording system with only 8 GHz bandwidth. A complete velocity profile of up to 11.47 km/s is measured on a three-stage light gas gun with velocity measurement accuracy of 1%.
- Open Access
- 20 September 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (9) , 1165
The Side-Release Method Measures the High-Pressure Sound Velocity of Iron Using Line-Spatially Resolved DISAR
The study of high-pressure sound velocity is an important part of shock wave physics, and the study of ultra-high pressure sound velocity of iron is of great significance to many research fields such as geophysics, solid state physics, and crystallography. At present, the measurement of sound velocity is usually carried out by the catch-up sparse wave method and windowed VISAR technology, which is complex in structure and not highly adaptable. In particular, for the ultra-high pressure sonic velocity measurement of metals, it is limited by the loading platform and window materials and cannot realize the high temperature and high-pressure environment of the earth’s inner core. In this paper, the sound velocity measurement of iron under high temperature and high-pressure environment (78 GPa) is realized based on the two-stage light gas cannon experimental platform. The side-side sparse wave method was used to establish a coupling model of high-spatially resolved optical group and fiber bundle. A multiplexed all-fiber laser interferometry velocity measurement system (DISAR) was built, and the spatial resolution was better than 20 μm. In this paper, we will provide a feasible route for a method for measuring the high spatiotemporal resolution velocity.
- 20 September 2024
- Published by MDPI AG in Micromachines
- Vol. 15 (9) , 1165
Open AccessThe Side-Release Method Measures the High-Pressure Sound Velocity of Iron Using Line-Spatially Resolved DISAR
The study of high-pressure sound velocity is an important part of shock wave physics, and the study of ultra-high pressure sound velocity of iron is of great significance to many research fields such as geophysics, solid state physics, and crystallography. At present, the measurement of sound velocity is usually carried out by the catch-up sparse wave method and windowed VISAR technology, which is complex in structure and not highly adaptable. In particular, for the ultra-high pressure sonic velocity measurement of metals, it is limited by the loading platform and window materials and cannot realize the high temperature and high-pressure environment of the earth’s inner core. In this paper, the sound velocity measurement of iron under high temperature and high-pressure environment (78 GPa) is realized based on the two-stage light gas cannon experimental platform. The side-side sparse wave method was used to establish a coupling model of high-spatially resolved optical group and fiber bundle. A multiplexed all-fiber laser interferometry velocity measurement system (DISAR) was built, and the spatial resolution was better than 20 μm. In this paper, we will provide a feasible route for a method for measuring the high spatiotemporal resolution velocity.
- Open Access
Upconversion Photonic Doppler Velocimetry Based on Stimulated Brillouin Scattering
Optical up-conversion photonic Doppler velocimetry (PDV) based on stimulated Brillouin Scattering (SBS) with an all-fiber link structure is proposed in this article. Because SBS limits the laser power transmitted by a fiber over long distances, the probe does not have enough outgoing light to reach the measured surface and cannot receive the signal light. Traditionally, SBS is avoided, but it is a phase-conjugated light and shifts down relative to the source light, so it can be used as a reference light in the laser interference structure to achieve up-conversion heterodyne velocimetry. Compared with general homodyne velocimetry (DPS), SBS-PDV naturally upconverts and has more interference fringes and higher resolution at low-speed measurement. In the gas multiple reflection impact compression experiment, the velocity measurement results of SBS-PDV and dual-laser heterodyne Velocimetry (DLHV) are basically consistent, and the accuracy is better than 0.8%. Due to its coaxial heterodyne optical path, this kind of photonic Doppler velocimetry is suitable for low-velocity and long-distance practical applications in the field of shock wave physics.
Open AccessUpconversion Photonic Doppler Velocimetry Based on Stimulated Brillouin Scattering
Optical up-conversion photonic Doppler velocimetry (PDV) based on stimulated Brillouin Scattering (SBS) with an all-fiber link structure is proposed in this article. Because SBS limits the laser power transmitted by a fiber over long distances, the probe does not have enough outgoing light to reach the measured surface and cannot receive the signal light. Traditionally, SBS is avoided, but it is a phase-conjugated light and shifts down relative to the source light, so it can be used as a reference light in the laser interference structure to achieve up-conversion heterodyne velocimetry. Compared with general homodyne velocimetry (DPS), SBS-PDV naturally upconverts and has more interference fringes and higher resolution at low-speed measurement. In the gas multiple reflection impact compression experiment, the velocity measurement results of SBS-PDV and dual-laser heterodyne Velocimetry (DLHV) are basically consistent, and the accuracy is better than 0.8%. Due to its coaxial heterodyne optical path, this kind of photonic Doppler velocimetry is suitable for low-velocity and long-distance practical applications in the field of shock wave physics.
- Open Access
All-Fiber Pulse-Train Optical Frequency-Domain Interferometer for Dynamic Absolute Distance Measurements of Vibration
In this paper, we propose an all-fiber co-axial optical frequency-domain interferometer (OFDI) in a pulse-train mode with a sample rate of 9 kHz for measuring the vibrations in an internal structure without any contact. It was subjected to a range of 4.555 mm and had an accuracy level of 0.006 mm, as confirmed by a linear motion experiment. Due to the precise time synchronization for reducing the background light leakage and suppressing the dynamic fuzziness, the proposed OFDI could realize the dynamic absolute distance measurements of the vibration process under harmonic excitation with frequencies ranging from 200 Hz to 1800 Hz. The characteristic parameters of vibration could be analyzed using the acquired distance results. Furthermore, the OFDI system obtained the frequency conversion as the time under anharmonic periodic excitation with a sweeping rate of 3600 Hz/s. The measurement performance for the vibration velocity compared with the displacement interferometer system for any reflector (DISAR) was demonstrated in a harmonic excitation experiment. The proposed method expands the application of all-fiber OFDI technology from static to dynamic scenes.
Open AccessAll-Fiber Pulse-Train Optical Frequency-Domain Interferometer for Dynamic Absolute Distance Measurements of Vibration
In this paper, we propose an all-fiber co-axial optical frequency-domain interferometer (OFDI) in a pulse-train mode with a sample rate of 9 kHz for measuring the vibrations in an internal structure without any contact. It was subjected to a range of 4.555 mm and had an accuracy level of 0.006 mm, as confirmed by a linear motion experiment. Due to the precise time synchronization for reducing the background light leakage and suppressing the dynamic fuzziness, the proposed OFDI could realize the dynamic absolute distance measurements of the vibration process under harmonic excitation with frequencies ranging from 200 Hz to 1800 Hz. The characteristic parameters of vibration could be analyzed using the acquired distance results. Furthermore, the OFDI system obtained the frequency conversion as the time under anharmonic periodic excitation with a sweeping rate of 3600 Hz/s. The measurement performance for the vibration velocity compared with the displacement interferometer system for any reflector (DISAR) was demonstrated in a harmonic excitation experiment. The proposed method expands the application of all-fiber OFDI technology from static to dynamic scenes.
- Open Access
Microwave Absolute Distance Measurement Method with Ten-Micron-Level Accuracy and Meter-Level Range Based on Frequency Domain Interferometry
A microwave absolute distance measurement method with ten-micron-level accuracy and meter-level range based on frequency domain interferometry is proposed and experimentally demonstrated for the first time. Theoretical analysis indicates that an interference phenomenon occurs instantaneously in the frequency domain when combining two homologous broad-spectrum microwave beams with different paths, and the absolute value of the distance difference between the two paths is only inversely proportional to the period of frequency domain interference fringes. The proof-of-principle experiments were performed to prove that the proposed method can achieve absolute distance measurement in the X-band with standard deviations of 15 μm, 17 μm, and 26 μm and within ranges of 1.69 m, 2.69 m, and 3.75 m. Additionally, a displacement resolution of 100 microns was realized. The multi-target recognition performance was also verified in principle. Furthermore, at the expense of a slight decrease in ranging accuracy, a fast distance measurement with the single measurement time of 20 μs was achieved by using a digitizer combined with a Fourier transform analyzer. Compared with the current microwave precision ranging technologies, the proposed method not only has the advantages of high precision, large range, and rapid measurement capability, but the required components are also easily obtainable commercial devices. The proposed method also has better complex engineering applicability, because the ten-micron-level ranging accuracy is achievable only by using a simple Fourier transform without any phase estimation algorithm, which greatly reduces the requirement for signal-to-noise ratio.
Open AccessMicrowave Absolute Distance Measurement Method with Ten-Micron-Level Accuracy and Meter-Level Range Based on Frequency Domain Interferometry
A microwave absolute distance measurement method with ten-micron-level accuracy and meter-level range based on frequency domain interferometry is proposed and experimentally demonstrated for the first time. Theoretical analysis indicates that an interference phenomenon occurs instantaneously in the frequency domain when combining two homologous broad-spectrum microwave beams with different paths, and the absolute value of the distance difference between the two paths is only inversely proportional to the period of frequency domain interference fringes. The proof-of-principle experiments were performed to prove that the proposed method can achieve absolute distance measurement in the X-band with standard deviations of 15 μm, 17 μm, and 26 μm and within ranges of 1.69 m, 2.69 m, and 3.75 m. Additionally, a displacement resolution of 100 microns was realized. The multi-target recognition performance was also verified in principle. Furthermore, at the expense of a slight decrease in ranging accuracy, a fast distance measurement with the single measurement time of 20 μs was achieved by using a digitizer combined with a Fourier transform analyzer. Compared with the current microwave precision ranging technologies, the proposed method not only has the advantages of high precision, large range, and rapid measurement capability, but the required components are also easily obtainable commercial devices. The proposed method also has better complex engineering applicability, because the ten-micron-level ranging accuracy is achievable only by using a simple Fourier transform without any phase estimation algorithm, which greatly reduces the requirement for signal-to-noise ratio.
- Open Access
- 15 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (24) , 11928
Frequency-Tunable Pulsed Microwave Waveform Generation Based on Unbalanced Single-Arm Interferometer Excited by Near-Infrared Femtosecond Laser
Femtosecond laser-excited generation of frequency-tunable microwave pulses, based on an unbalanced single-arm interferometer with frequency-to-time mapping, has been proposed and demonstrated with easy-to-obtain commercial devices. The optical wave-to-microwave frequency conversion, which involves continuous tuning in the range from 2.0 GHz to 19.7 GHz, was achieved based on simple spatial–optical group delay adjustment. Additionally, the pulse duration of the microwave waveform was measured to be 24 ns as the length of the linear dispersion optical fiber was fixed at 20 km. In addition, owing to the designs of the single-arm optical path and polarization-independent interference, the generated microwave pulse train had better stability in terms of frequency and electrical amplitude. Furthermore, a near-triangular-shaped microwave pulse at 4.5 GHz was experimentally obtained by the superposition of two generated sinusoidal signals, which verified the potential of this system to synthesize special microwave waveform pulses.
- 15 December 2021
- Published by MDPI AG in Applied Sciences
- Vol. 11 (24) , 11928
Open AccessFrequency-Tunable Pulsed Microwave Waveform Generation Based on Unbalanced Single-Arm Interferometer Excited by Near-Infrared Femtosecond Laser
Femtosecond laser-excited generation of frequency-tunable microwave pulses, based on an unbalanced single-arm interferometer with frequency-to-time mapping, has been proposed and demonstrated with easy-to-obtain commercial devices. The optical wave-to-microwave frequency conversion, which involves continuous tuning in the range from 2.0 GHz to 19.7 GHz, was achieved based on simple spatial–optical group delay adjustment. Additionally, the pulse duration of the microwave waveform was measured to be 24 ns as the length of the linear dispersion optical fiber was fixed at 20 km. In addition, owing to the designs of the single-arm optical path and polarization-independent interference, the generated microwave pulse train had better stability in terms of frequency and electrical amplitude. Furthermore, a near-triangular-shaped microwave pulse at 4.5 GHz was experimentally obtained by the superposition of two generated sinusoidal signals, which verified the potential of this system to synthesize special microwave waveform pulses.