Xiangyu Meng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Xiangyu Meng has a total of 62 co-authors. Here are the top co-authors by number of shared publications:
- Zhigang Liu
Southwest Jiaotong University
18 shared publications - Qiao Zhang
Southwest Jiaotong University
5 shared publications - Bing Lu
Southwest Jiaotong University
4 shared publications - Guiyang Hu
School of Electrical Engineering, Southwest Jiaotong University, Chengdu, China
3 shared publications - Hongjian Lin
Hunan University
3 shared publications - Hui Wang
Southwest Jiaotong University
3 shared publications
Latest Publications
- Top Cited Papers
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (7) , 9850-9862
Dissipativity-Based Multiport Stability Root-Cause Identification and Mitigation for Solid-State Transformers
- 1 July 2026
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 73 (7) , 9850-9862
Top Cited PapersDissipativity-Based Multiport Stability Root-Cause Identification and Mitigation for Solid-State Transformers
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 12 (2) , 3679-3689
Flexible Operation for Wayside Hybrid Energy Storage System in Electrified Railway: A Variable-Timebox Model Based on Temporal Clustering Method
In electrified railways, the train generates substantial regenerative braking energy (RBE) during braking mode. Deploying wayside hybrid energy storage systems (HESSs) offers a promising solution for recovering and reusing this energy. However, due to the highly fluctuating nature of train power, existing methods based on fixed timescales often struggle to achieve an effective tradeoff between computational efficiency and modeling accuracy. To resolve these limitations, this article proposes a novel operation approach for HESS based on a variable-timebox model. First, a variable-timebox model is constructed, in which the charging and discharging durations of HESS are treated as decision variables. The model simultaneously optimizes RBE recovery and battery capacity degradation by considering the depth of discharge (DoD). Second, to determine the reasonable duration range, a temporal clustering method is proposed. A change point detection (CPD) strategy based on an improved cumulative sum (CUSUM) algorithm is employed to identify characteristics of the traction load. Finally, the effectiveness of the proposed method is validated using real-world data. The simulation results demonstrate that the proposed method reduces computation time by more than 60% while maintaining modeling accuracy.
- 22 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 12 (2) , 3679-3689
Flexible Operation for Wayside Hybrid Energy Storage System in Electrified Railway: A Variable-Timebox Model Based on Temporal Clustering Method
In electrified railways, the train generates substantial regenerative braking energy (RBE) during braking mode. Deploying wayside hybrid energy storage systems (HESSs) offers a promising solution for recovering and reusing this energy. However, due to the highly fluctuating nature of train power, existing methods based on fixed timescales often struggle to achieve an effective tradeoff between computational efficiency and modeling accuracy. To resolve these limitations, this article proposes a novel operation approach for HESS based on a variable-timebox model. First, a variable-timebox model is constructed, in which the charging and discharging durations of HESS are treated as decision variables. The model simultaneously optimizes RBE recovery and battery capacity degradation by considering the depth of discharge (DoD). Second, to determine the reasonable duration range, a temporal clustering method is proposed. A change point detection (CPD) strategy based on an improved cumulative sum (CUSUM) algorithm is employed to identify characteristics of the traction load. Finally, the effectiveness of the proposed method is validated using real-world data. The simulation results demonstrate that the proposed method reduces computation time by more than 60% while maintaining modeling accuracy.
- 8 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 12 (1) , 578-588
Resilient and Robust Voltage Regulation in Shipboard DC Microgrids With ZIP Loads Under Actuator and Parameter Uncertainties
The increasing adoption of all-electric ships and seaport microgrids has highlighted the critical need for robust and resilient control in shipboard dc microgrids. These islanded systems, operating as independent power networks with limited capacity, face significant challenges in maintaining stable voltage levels, particularly under uncertainties, which can compromise system performance and reliability. To address these challenges, this article proposes a novel resilient and robust voltage regulation control for shipboard dc microgrids with constant impedance (Z), constant current (I), and constant power (P) loads. The control framework models actuator uncertainties as unanticipated disturbances, requiring resilient response, while handling deterministic parameter uncertainties through robust design. The proposed approach integrates an adaptive control technique with mechanisms to estimate and compensate for actuator uncertainties, ensuring resilient voltage regulation even under adverse conditions. Decentralized conditions for the voltage stability of closed-loop microgrids are derived. The proposed strategy enhances the resilience of shipboard dc microgrids and provides a framework for their reliable operation under uncertainties. Hardware-in-the-loop (HIL) and simulation results in MATLAB/Simscape Electrical demonstrate the effectiveness of the proposed approach in achieving stable and resilient voltage control, offering a robust framework for reliable maritime power systems.
- 8 October 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 12 (1) , 578-588
Resilient and Robust Voltage Regulation in Shipboard DC Microgrids With ZIP Loads Under Actuator and Parameter Uncertainties
The increasing adoption of all-electric ships and seaport microgrids has highlighted the critical need for robust and resilient control in shipboard dc microgrids. These islanded systems, operating as independent power networks with limited capacity, face significant challenges in maintaining stable voltage levels, particularly under uncertainties, which can compromise system performance and reliability. To address these challenges, this article proposes a novel resilient and robust voltage regulation control for shipboard dc microgrids with constant impedance (Z), constant current (I), and constant power (P) loads. The control framework models actuator uncertainties as unanticipated disturbances, requiring resilient response, while handling deterministic parameter uncertainties through robust design. The proposed approach integrates an adaptive control technique with mechanisms to estimate and compensate for actuator uncertainties, ensuring resilient voltage regulation even under adverse conditions. Decentralized conditions for the voltage stability of closed-loop microgrids are derived. The proposed strategy enhances the resilience of shipboard dc microgrids and provides a framework for their reliable operation under uncertainties. Hardware-in-the-loop (HIL) and simulation results in MATLAB/Simscape Electrical demonstrate the effectiveness of the proposed approach in achieving stable and resilient voltage control, offering a robust framework for reliable maritime power systems.
- 9 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (5) , 10886-10901
Adaptive Resilient Current Control for Grid-Interactive Inverters in Vehicle-to-Grid Systems Using a Dynamic Corrective Method Considering Sensor Data Integrity Manipulation
This article presents an innovative adaptive resilient vector current control scheme for three-phase grid-connected (GC) inverters in vehicle-to-grid (V2G) systems. As V2G systems advance with increasing intelligence and connectivity, cyber-physical security has become a critical concern. A particular challenge lies in data integrity issues, where attackers can manipulate measurement data within the cyber layer. To address this, the proposed control scheme mitigates the impact of false data injection (FDI) targeting output inverter measurements in the control loop. By employing a dynamic corrective method to restore manipulated measurements, the proposed scheme ensures accurate tracking of output currents and maintains inverter resilience—thereby enhancing the stability of V2G systems against such malicious disruptions. Theoretical analysis based on Lyapunov theory confirms the boundedness and stability of the closed-loop control system. The results of the simulation and experiment further demonstrate the effectiveness of the proposed control methodology.
- 9 May 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (5) , 10886-10901
Adaptive Resilient Current Control for Grid-Interactive Inverters in Vehicle-to-Grid Systems Using a Dynamic Corrective Method Considering Sensor Data Integrity Manipulation
This article presents an innovative adaptive resilient vector current control scheme for three-phase grid-connected (GC) inverters in vehicle-to-grid (V2G) systems. As V2G systems advance with increasing intelligence and connectivity, cyber-physical security has become a critical concern. A particular challenge lies in data integrity issues, where attackers can manipulate measurement data within the cyber layer. To address this, the proposed control scheme mitigates the impact of false data injection (FDI) targeting output inverter measurements in the control loop. By employing a dynamic corrective method to restore manipulated measurements, the proposed scheme ensures accurate tracking of output currents and maintains inverter resilience—thereby enhancing the stability of V2G systems against such malicious disruptions. Theoretical analysis based on Lyapunov theory confirms the boundedness and stability of the closed-loop control system. The results of the simulation and experiment further demonstrate the effectiveness of the proposed control methodology.
- 29 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Dual-Domain Conditional Generative Adversarial Networks for Predicting the Contact Force Curve of Pantograph–Catenary System in High-Speed Railway
In electric railways, the current collection quality of pantograph-catenary systems (PCS) is typically evaluated through numerical simulations using the finite element method, which is computationally expensive and time-consuming. To address this challenge, we propose a surrogate modelling approach that trains a conditional generative model to approximate the output of the reference numerical model. Specifically, we introduce Dual-Domain Conditional Generative Adversarial Networks (DD-CGAN) to generate contact force curves for various PCS parameter configurations. The generator network takes system parameters as input and produces the corresponding contact force curve, while the discriminator network distinguishes between real and predicted curves in both the time and frequency domains, ensuring greater consistency. Furthermore, the feature fusion module is proposed to extract and integrate time-domain and frequency-domain features by using a multi-scale channel attention mechanism. Extensive experimental results demonstrate the effectiveness and advantages of DD-CGAN for surrogate modelling of pantograph-catenary interactions. The contact force curves generated by our method exhibit high consistency with simulation results from high-fidelity numerical models with a mean absolute error of 0.9815, which is six times more accurate than state-of-the-art methods. Most importantly, our method achieves a speedup of nearly 1000x compared to traditional numerical simulations, highlighting its potential for practical use in designing and optimizing catenary structural parameters.
- 29 April 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-13
Dual-Domain Conditional Generative Adversarial Networks for Predicting the Contact Force Curve of Pantograph–Catenary System in High-Speed Railway
In electric railways, the current collection quality of pantograph-catenary systems (PCS) is typically evaluated through numerical simulations using the finite element method, which is computationally expensive and time-consuming. To address this challenge, we propose a surrogate modelling approach that trains a conditional generative model to approximate the output of the reference numerical model. Specifically, we introduce Dual-Domain Conditional Generative Adversarial Networks (DD-CGAN) to generate contact force curves for various PCS parameter configurations. The generator network takes system parameters as input and produces the corresponding contact force curve, while the discriminator network distinguishes between real and predicted curves in both the time and frequency domains, ensuring greater consistency. Furthermore, the feature fusion module is proposed to extract and integrate time-domain and frequency-domain features by using a multi-scale channel attention mechanism. Extensive experimental results demonstrate the effectiveness and advantages of DD-CGAN for surrogate modelling of pantograph-catenary interactions. The contact force curves generated by our method exhibit high consistency with simulation results from high-fidelity numerical models with a mean absolute error of 0.9815, which is six times more accurate than state-of-the-art methods. Most importantly, our method achieves a speedup of nearly 1000x compared to traditional numerical simulations, highlighting its potential for practical use in designing and optimizing catenary structural parameters.
- 31 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (8) , 11170-11181
Data-Light Oscillation Mode Identification for Fast Stability Assessment of Grid-Tied Converters
Dynamic mode decomposition (DMD) is an effective data-driven oscillation mode identification method for instability identification in grid-tied converters. However, time-consuming computation and empirical setting of parameters limit its practical application in rapid stability assessment. This article introduces data-light dynamic mode decomposition (DL-DMD) by integrating the conventional dynamic mode decomposition (DMD) algorithm with harmonic state space theory, which significantly improves computational speed while providing a bandwidth-oriented interpretation for parameter selection in correspondence with the identifiable frequency range of modes. The effectiveness and advantages of the proposed method are verified through offline analysis and online tests based on an experimental platform.
- 31 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 40 (8) , 11170-11181
Data-Light Oscillation Mode Identification for Fast Stability Assessment of Grid-Tied Converters
Dynamic mode decomposition (DMD) is an effective data-driven oscillation mode identification method for instability identification in grid-tied converters. However, time-consuming computation and empirical setting of parameters limit its practical application in rapid stability assessment. This article introduces data-light dynamic mode decomposition (DL-DMD) by integrating the conventional dynamic mode decomposition (DMD) algorithm with harmonic state space theory, which significantly improves computational speed while providing a bandwidth-oriented interpretation for parameter selection in correspondence with the identifiable frequency range of modes. The effectiveness and advantages of the proposed method are verified through offline analysis and online tests based on an experimental platform.
- 25 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (4) , 8756-8767
A Novel Hybrid Energy Storage Configuration Framework for Mountain Electrified Railways With Long and Steep Slopes
The electrified railways in high-altitude mountainous areas often feature long and steep slopes. These characteristics pose two primary challenges: traction network overvoltage caused by regenerative braking energy (RBE) in downhill and train stalls in uphill sections due to insufficient voltage supply. Configuring energy storage is feasible for recycling RBE and ensuring a stable power supply. However, existing research merely focuses on the size of energy storage systems (ESSs), failing to address the optimal siting and sizing problem adequately. To this end, this article proposes a novel hybrid ESS (HESS) configuration framework. First, the operation status of the train on long and steep slopes is analyzed, and RBE is decomposed into components suitable for the battery and supercapacitor based on a variational mode decomposition (VMD). Second, regarding the traction station, section post (SP), and overhead contact line (OCL) as HESS’s candidate locations, the types of trains are considered, and a siting and sizing optimization model is built to pursue the cost-benefit and traction network voltage. Finally, a improved combining multiobjective optimization with differential evolution (ICMODE) algorithm is proposed to solve the model. The simulation results validate the effectiveness of the method based on the actual data.
- 25 March 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (4) , 8756-8767
A Novel Hybrid Energy Storage Configuration Framework for Mountain Electrified Railways With Long and Steep Slopes
The electrified railways in high-altitude mountainous areas often feature long and steep slopes. These characteristics pose two primary challenges: traction network overvoltage caused by regenerative braking energy (RBE) in downhill and train stalls in uphill sections due to insufficient voltage supply. Configuring energy storage is feasible for recycling RBE and ensuring a stable power supply. However, existing research merely focuses on the size of energy storage systems (ESSs), failing to address the optimal siting and sizing problem adequately. To this end, this article proposes a novel hybrid ESS (HESS) configuration framework. First, the operation status of the train on long and steep slopes is analyzed, and RBE is decomposed into components suitable for the battery and supercapacitor based on a variational mode decomposition (VMD). Second, regarding the traction station, section post (SP), and overhead contact line (OCL) as HESS’s candidate locations, the types of trains are considered, and a siting and sizing optimization model is built to pursue the cost-benefit and traction network voltage. Finally, a improved combining multiobjective optimization with differential evolution (ICMODE) algorithm is proposed to solve the model. The simulation results validate the effectiveness of the method based on the actual data.
- Top Cited Papers
- 17 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (1) , 4429-4442
Neural Network-Based Impedance Identification and Stability Analysis for Double-Sided Feeding Railway Systems
The double-sided power supply railway system increases the simultaneous operation of vehicles on the grid, potentially causing system instability and oscillation overvoltage issues. As vehicles frequently switch operating points during operation, it is essential to analyze system stability across a wide range of conditions. Therefore, accurately identifying the black-box impedance of vehicle converters at multiple operating points is crucial for studying railway vehicle-grid system stability. However, traditional impedance identification methods require extensive data and lack interpretability, leading to significant computational and data burdens. This study introduces an interpretable residual feedforward neural network (ResFNN) combined with SHapley Additive exPlanations for training vehicle impedance models, reducing data requirements while maintaining accuracy. Additionally, a component connection method is proposed for deriving the impedance matrix of a multi-vehicle railway system under the double-sided feeding mode. This method incorporates the dynamic mobility of vehicles and their positional distribution, and it utilizes the ResFNN to identify impedance for stability analysis. Real operational data from actual railway lines is used as case study to analyze the stability of the double-sided power supply railway system. The results demonstrate that this approach accurately assesses both low-frequency and high-frequency instability issues.
- 17 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Transportation Electrification
- Vol. 11 (1) , 4429-4442
Top Cited PapersNeural Network-Based Impedance Identification and Stability Analysis for Double-Sided Feeding Railway Systems
The double-sided power supply railway system increases the simultaneous operation of vehicles on the grid, potentially causing system instability and oscillation overvoltage issues. As vehicles frequently switch operating points during operation, it is essential to analyze system stability across a wide range of conditions. Therefore, accurately identifying the black-box impedance of vehicle converters at multiple operating points is crucial for studying railway vehicle-grid system stability. However, traditional impedance identification methods require extensive data and lack interpretability, leading to significant computational and data burdens. This study introduces an interpretable residual feedforward neural network (ResFNN) combined with SHapley Additive exPlanations for training vehicle impedance models, reducing data requirements while maintaining accuracy. Additionally, a component connection method is proposed for deriving the impedance matrix of a multi-vehicle railway system under the double-sided feeding mode. This method incorporates the dynamic mobility of vehicles and their positional distribution, and it utilizes the ResFNN to identify impedance for stability analysis. Real operational data from actual railway lines is used as case study to analyze the stability of the double-sided power supply railway system. The results demonstrate that this approach accurately assesses both low-frequency and high-frequency instability issues.