Shonosuke Matsushita
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shonosuke Matsushita has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Yuzuru Sakakibara
Graduate School of Comprehensive Human Science, Department of Thoracic and Cardiovascular Surgery, University of Tsukuba, 1-1-1 Tennodai, Tsukuba, Ibaraki 305-8575, Japan
6 shared publicationsYuji Hiramatsu
University of Tsukuba
4 shared publicationsFujio Sato
University of Tsukuba
3 shared publicationsKazuyuki Hyodo
High Energy Accelerator Research Organization, KEK, Tsukuba, Ibaraki 305-0801, Japan
3 shared publicationsChiho Tokunaga
University of Tsukuba
2 shared publicationsTomohiro Imazuru
2 shared publications
Latest Publications
- Open Access
- 8 February 2013
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 20 (2) , 376-382
Using synchrotron radiation angiography with a highly sensitive detector to identify impaired peripheral perfusion in rat pulmonary emphysema
Owing to limitations in spatial resolution and sensitivity, it is difficult for conventional angiography to detect minute changes of perfusion in diffuse lung diseases, including pulmonary emphysema (PE). However, a high-gain avalanche rushing amorphous photoconductor (HARP) detector can give high sensitivity to synchrotron radiation (SR) angiography. SR angiography with a HARP detector provides high spatial resolution and sensitivity in addition to time resolution owing to its angiographic nature. The purpose of this study was to investigate whether this SR angiography with a HARP detector could evaluate altered microcirculation in PE. Two groups of rats were used: group PE and group C (control). Transvenous SR angiography with a HARP detector was performed and histopathological findings were compared. Peak density of contrast material in peripheral lung was lower in group PE than group C (p < 0.01). The slope of the linear regression line in scattering diagrams was also lower in group PE than C (p < 0.05). The correlation between the slope and extent of PE in histopathology showed significant negative correlation (p < 0.05, r = 0.61). SR angiography with a HARP detector made it possible to identify impaired microcirculation in PE by means of its high spatial resolution and sensitivity.
- 8 February 2013
- Published by International Union of Crystallography (IUCr) in Journal of Synchrotron Radiation
- Vol. 20 (2) , 376-382
Open AccessUsing synchrotron radiation angiography with a highly sensitive detector to identify impaired peripheral perfusion in rat pulmonary emphysema
Owing to limitations in spatial resolution and sensitivity, it is difficult for conventional angiography to detect minute changes of perfusion in diffuse lung diseases, including pulmonary emphysema (PE). However, a high-gain avalanche rushing amorphous photoconductor (HARP) detector can give high sensitivity to synchrotron radiation (SR) angiography. SR angiography with a HARP detector provides high spatial resolution and sensitivity in addition to time resolution owing to its angiographic nature. The purpose of this study was to investigate whether this SR angiography with a HARP detector could evaluate altered microcirculation in PE. Two groups of rats were used: group PE and group C (control). Transvenous SR angiography with a HARP detector was performed and histopathological findings were compared. Peak density of contrast material in peripheral lung was lower in group PE than group C (p < 0.01). The slope of the linear regression line in scattering diagrams was also lower in group PE than C (p < 0.05). The correlation between the slope and extent of PE in histopathology showed significant negative correlation (p < 0.05, r = 0.61). SR angiography with a HARP detector made it possible to identify impaired microcirculation in PE by means of its high spatial resolution and sensitivity.
- 22 August 2012
- Published by Springer Nature in Surgery Today
- Vol. 43 (3) , 293-299
Significant correlation between endothelial nitric oxide synthase (eNOS) expression and alveolar repair in elastase-induced rat pulmonary emphysema
Angiogenic factors, such as endothelial nitric oxide synthase (eNOS), are thought to play an important role in the repair of pulmonary emphysema (PE); yet, the correlation of the factors involved has not been investigated. We conducted this study to clarify the positive correlation between eNOS expression and alveolar repair in PE recovery. We used elastase to induce PE in rats, which were divided into Groups A (Control), B (G-CSF), C (PE) and D (PE + G-CSF). G-CSF was injected for 12 days, 4 weeks after which the alveolar walls, arterioles, and angiogenic factors including eNOS were examined histopathologically and by western blotting. In comparing Groups A, B, C, and D, the alveolar density was 2.4 ± 0.2, 2.4 ± 0.1, 1.8 ± 0.1, 2.5 ± 0.1 per 100 μm2, respectively (C vs. others; p < 0.00001) and the number of arterioles was 4.5 ± 1.0, 5.6 ± 0.6, 3.2 ± 0.5, 5.5 ± 0.7/mm2, respectively (C vs. others; p < 0.05). Immunohistochemical staining (IHC) revealed different eNOS expression in Group D versus Group C (p < 0.0001) and western blotting revealed different eNOS, VEGF, and FLT-1 expression in Group D versus Group C (p < 0.01, p < 0.05, p < 0.001), reflecting the contribution of angiogenesis to PE repair. eNOS showed a significantly positive correlation to alveolar density and arteriole repair. Alveolar repair was correlated positively with eNOS expression by vascular regeneration in elastase-induced rat PE.
- 22 August 2012
- Published by Springer Nature in Surgery Today
- Vol. 43 (3) , 293-299
Significant correlation between endothelial nitric oxide synthase (eNOS) expression and alveolar repair in elastase-induced rat pulmonary emphysema
Angiogenic factors, such as endothelial nitric oxide synthase (eNOS), are thought to play an important role in the repair of pulmonary emphysema (PE); yet, the correlation of the factors involved has not been investigated. We conducted this study to clarify the positive correlation between eNOS expression and alveolar repair in PE recovery. We used elastase to induce PE in rats, which were divided into Groups A (Control), B (G-CSF), C (PE) and D (PE + G-CSF). G-CSF was injected for 12 days, 4 weeks after which the alveolar walls, arterioles, and angiogenic factors including eNOS were examined histopathologically and by western blotting. In comparing Groups A, B, C, and D, the alveolar density was 2.4 ± 0.2, 2.4 ± 0.1, 1.8 ± 0.1, 2.5 ± 0.1 per 100 μm2, respectively (C vs. others; p < 0.00001) and the number of arterioles was 4.5 ± 1.0, 5.6 ± 0.6, 3.2 ± 0.5, 5.5 ± 0.7/mm2, respectively (C vs. others; p < 0.05). Immunohistochemical staining (IHC) revealed different eNOS expression in Group D versus Group C (p < 0.0001) and western blotting revealed different eNOS, VEGF, and FLT-1 expression in Group D versus Group C (p < 0.01, p < 0.05, p < 0.001), reflecting the contribution of angiogenesis to PE repair. eNOS showed a significantly positive correlation to alveolar density and arteriole repair. Alveolar repair was correlated positively with eNOS expression by vascular regeneration in elastase-induced rat PE.
- 10 November 2011
- Published by Springer Nature in Surgery Today
- Vol. 42 (2) , 191-194
Surgical repair for rupture of a chronic traumatic thoracic aneurysm 14 years after injury: report of a case
Traumatic thoracic aortic injury is a lethal condition. Because its mortality rate is extremely high in the acute phase, these patients rarely survive long enough for a chronic aneurysm to develop. We herein report a case of surgical repair for a ruptured chronic traumatic thoracic aneurysm. A 32-year-old man, who had been involved in a traffic accident 14 years earlier, was diagnosed with a rupture of a chronic traumatic thoracic aneurysm. Preoperative computed tomography showed that the ruptured aneurysm arose from the aortic isthmus and was accompanied by multiple daughter lesions. He underwent an aorta graft replacement with reconstruction of the left subclavian artery using both a median sternotomy and a left thoracotomy. The surgery was successful and the postoperative course was uneventful. Chronic traumatic thoracic aneurysm is usually a single lesion, and cases with daughter aneurysms have rarely been reported. We include a review of the previous literature and also discuss the etiology of this condition.
- 10 November 2011
- Published by Springer Nature in Surgery Today
- Vol. 42 (2) , 191-194
Surgical repair for rupture of a chronic traumatic thoracic aneurysm 14 years after injury: report of a case
Traumatic thoracic aortic injury is a lethal condition. Because its mortality rate is extremely high in the acute phase, these patients rarely survive long enough for a chronic aneurysm to develop. We herein report a case of surgical repair for a ruptured chronic traumatic thoracic aneurysm. A 32-year-old man, who had been involved in a traffic accident 14 years earlier, was diagnosed with a rupture of a chronic traumatic thoracic aneurysm. Preoperative computed tomography showed that the ruptured aneurysm arose from the aortic isthmus and was accompanied by multiple daughter lesions. He underwent an aorta graft replacement with reconstruction of the left subclavian artery using both a median sternotomy and a left thoracotomy. The surgery was successful and the postoperative course was uneventful. Chronic traumatic thoracic aneurysm is usually a single lesion, and cases with daughter aneurysms have rarely been reported. We include a review of the previous literature and also discuss the etiology of this condition.
- 1 September 2011
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 197 (3) , W508-W513
Reducing the Dose of Contrast Medium in Angiography by Use of a Highly Sensitive Receiver and Synchrotron Radiation System
OBJECTIVE. Contrast medium causes side effects such as contrast-induced nephropathy, and the dose of contrast medium is a risk factor in their occurrence. To reduce doses of contrast medium, we developed an angiographic system with high definition and high sensitivity and reviewed its effectiveness. The system entails synchrotron radiation, which is characterized by high photon density and straightness of beam that together result in high resolution, and a high-gain avalanche rushing amorphous photoconductor receiver, which is 100 times more sensitive than conventional charge-coupled device cameras. MATERIALS AND METHODS. Diluted contrast medium was administered, and angiography of rat hindlimbs was performed with synchrotron radiation and the high-gain photoconductor receiver. The difference in gray-scale value between the background and contrast medium was calculated. Images were evaluated by counting of arteries. RESULTS. The difference in contrast at low levels was detected with the high-gain photoconductor receiver but not with the charge-coupled device camera. The photon density of synchrotron radiation with the high-gain photoconductor receiver was one-fifth that with the charge-coupled device camera. The high-gain photoconductor receiver had approximately 5 times the sensitivity of the charge-coupled device camera. CONCLUSION. Use of the synchrotron radiation and high-gain photoconductor receiver makes it possible to perform angiography with an extremely low concentration of contrast medium.
- 1 September 2011
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 197 (3) , W508-W513
Reducing the Dose of Contrast Medium in Angiography by Use of a Highly Sensitive Receiver and Synchrotron Radiation System
OBJECTIVE. Contrast medium causes side effects such as contrast-induced nephropathy, and the dose of contrast medium is a risk factor in their occurrence. To reduce doses of contrast medium, we developed an angiographic system with high definition and high sensitivity and reviewed its effectiveness. The system entails synchrotron radiation, which is characterized by high photon density and straightness of beam that together result in high resolution, and a high-gain avalanche rushing amorphous photoconductor receiver, which is 100 times more sensitive than conventional charge-coupled device cameras. MATERIALS AND METHODS. Diluted contrast medium was administered, and angiography of rat hindlimbs was performed with synchrotron radiation and the high-gain photoconductor receiver. The difference in gray-scale value between the background and contrast medium was calculated. Images were evaluated by counting of arteries. RESULTS. The difference in contrast at low levels was detected with the high-gain photoconductor receiver but not with the charge-coupled device camera. The photon density of synchrotron radiation with the high-gain photoconductor receiver was one-fifth that with the charge-coupled device camera. The high-gain photoconductor receiver had approximately 5 times the sensitivity of the charge-coupled device camera. CONCLUSION. Use of the synchrotron radiation and high-gain photoconductor receiver makes it possible to perform angiography with an extremely low concentration of contrast medium.
- 1 December 2008
- Published by Elsevier in European Journal of Radiology
- Vol. 68 (3) , S84-S88
The minimum coronary artery diameter in which coronary spasm can be identified by synchrotron radiation coronary angiography
- 1 December 2008
- Published by Elsevier in European Journal of Radiology
- Vol. 68 (3) , S84-S88
The minimum coronary artery diameter in which coronary spasm can be identified by synchrotron radiation coronary angiography
- 1 August 2005
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 548 (1-2) , 94-98
Coronary angiography in rats using synchrotron radiation
- 1 August 2005
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 548 (1-2) , 94-98
Coronary angiography in rats using synchrotron radiation
- 1 April 2004
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 77 (4) , 1293-1297
High-frequency QRS potentials as a marker of myocardial dysfunction after cardiac surgery
- 1 April 2004
- Published by Elsevier in The Annals of Thoracic Surgery
- Vol. 77 (4) , 1293-1297
High-frequency QRS potentials as a marker of myocardial dysfunction after cardiac surgery