Giulia Guarona
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Giulia Guarona has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Giancarlo Icardi
Department of Health Sciences, University of Genoa, 16132 Genoa, Italy
7 shared publications - Alexander Domnich
Hygiene Unit, San Martino Polyclinic Hospital-IRCCS for Oncology and Neurosciences, Genoa, Italy
6 shared publications - Andrea Orsi
Department of Health Sciences, University of Genoa, 16132 Genoa, Italy
5 shared publications - Valentina Ricucci
Hygiene Unit, San Martino Policlinico Hospital-IRCCS for Oncology and Neurosciences, 16132 Genoa, Italy
5 shared publications - Bianca Bruzzone
Hygiene Unit, San Martino Policlinico Hospital-IRCCS for Oncology and Neurosciences, 16132 Genoa, Italy
4 shared publications - Vanessa De Pace
Hygiene Unit, San Martino Policlinico Hospital-IRCCS for Oncology and Neurosciences, 16132 Genoa, Italy
4 shared publications
Latest Publications
- Open Access
- 27 March 2024
- Published by MDPI AG in Microorganisms
- Vol. 12 (4) , 664
Molecular Diagnosis of Human Monkeypox Virus during 2022–23 Outbreak: Preliminary Evaluation of Novel Real-Time Qualitative PCR Assays
In 2022–23, the human monkeypox virus (MPXV) caused a global outbreak in several non-endemic countries. Here, we evaluated the diagnostic performance of four real-time qualitative PCR assays for the laboratory diagnosis of mpox (monkeypox) monkeypox disease. From July to August 2022, 27 positive and 10 negative specimens (lesion, crust and exudate swabs) were tested in the laboratory of the Hygiene Unit of the San Martino Hospital (Genoa, Italy) by using home-made real-time PCR to detect MPXV generic G2R_G DNA. According to the manufacturer’s instructions, we also retrospectively analyzed these specimens using RealCycler MONK-UX/-GX (Progenie Molecular), STANDARD M10 MPX/OPX (SD Biosensor), Novaplex MPXV (Seegene Inc.) and RealStar Orthopoxvirus PCR Kit 1.0 (Altona Diagnostics) assays, recognized as research-use-only tests. The diagnostic accuracy and sensitivity of these assays ranged from 97.3% (95% CI: 86.2–99.5%) to 100% (95% CI: 90.6–100%) and 96.3% (95% CI: 81.72–99.34%) to 100% (95% CI: 72.2–100%), respectively. The RealCycler MONK-UX and STANDARD M10 MPX/OPX did not detect one positive sample with a cycle threshold of 36. The overall specificity was 100% (95% CI: 72.2–100%), and Cohen’s Kappa values ranged from 1 (95% CI: 0.67–1) to 0.93 (95% CI: 0.61–1). As they are highly accurate, reliable and user-friendly, these tests should be recommended for the routine or rapid laboratory discrimination of mpox from other rash illnesses.
- 27 March 2024
- Published by MDPI AG in Microorganisms
- Vol. 12 (4) , 664
Open AccessMolecular Diagnosis of Human Monkeypox Virus during 2022–23 Outbreak: Preliminary Evaluation of Novel Real-Time Qualitative PCR Assays
In 2022–23, the human monkeypox virus (MPXV) caused a global outbreak in several non-endemic countries. Here, we evaluated the diagnostic performance of four real-time qualitative PCR assays for the laboratory diagnosis of mpox (monkeypox) monkeypox disease. From July to August 2022, 27 positive and 10 negative specimens (lesion, crust and exudate swabs) were tested in the laboratory of the Hygiene Unit of the San Martino Hospital (Genoa, Italy) by using home-made real-time PCR to detect MPXV generic G2R_G DNA. According to the manufacturer’s instructions, we also retrospectively analyzed these specimens using RealCycler MONK-UX/-GX (Progenie Molecular), STANDARD M10 MPX/OPX (SD Biosensor), Novaplex MPXV (Seegene Inc.) and RealStar Orthopoxvirus PCR Kit 1.0 (Altona Diagnostics) assays, recognized as research-use-only tests. The diagnostic accuracy and sensitivity of these assays ranged from 97.3% (95% CI: 86.2–99.5%) to 100% (95% CI: 90.6–100%) and 96.3% (95% CI: 81.72–99.34%) to 100% (95% CI: 72.2–100%), respectively. The RealCycler MONK-UX and STANDARD M10 MPX/OPX did not detect one positive sample with a cycle threshold of 36. The overall specificity was 100% (95% CI: 72.2–100%), and Cohen’s Kappa values ranged from 1 (95% CI: 0.67–1) to 0.93 (95% CI: 0.61–1). As they are highly accurate, reliable and user-friendly, these tests should be recommended for the routine or rapid laboratory discrimination of mpox from other rash illnesses.
- Open Access
- 30 June 2022
- Published by MDPI AG in Biomedicines
- Vol. 10 (7) , 1558
High Diagnostic Accuracy of a Novel Lateral Flow Assay for the Point-of-Care Detection of SARS-CoV-2
Highly accurate lateral flow immunochromatographic tests (LFTs) are an important public health tool to tackle the ongoing COVID-19 pandemic. The aim of this study was to assess the comparative diagnostic performance of the novel ND COVID-19 LFT under real-world conditions. A total of 400 nasopharyngeal swab specimens with a wide range of viral loads were tested in both reverse-transcription polymerase chain reaction and ND LFT. The overall sensitivity and specificity were 85% (95% CI: 76.7–90.7%) and 100% (95% CI: 98.7–100%), respectively. There was a clear association between the false-negative rate and sample viral load: the sensitivity parameters for specimens with cycle threshold values of 3.95 × 106 copies/mL) and ≥30 (≤1.29 × 105 copies/mL) were 100% and 50%, respectively. The performance was maximized in testing samples with viral loads ≥1.29 × 105 copies/mL. These findings suggest that the ND LFT is sufficiently accurate and useful for mass population screening programs, especially in high-prevalence and resource-constrained settings or during periods when the epidemic curve is rising. Other public health implications were also discussed.
- 30 June 2022
- Published by MDPI AG in Biomedicines
- Vol. 10 (7) , 1558
Open AccessHigh Diagnostic Accuracy of a Novel Lateral Flow Assay for the Point-of-Care Detection of SARS-CoV-2
Highly accurate lateral flow immunochromatographic tests (LFTs) are an important public health tool to tackle the ongoing COVID-19 pandemic. The aim of this study was to assess the comparative diagnostic performance of the novel ND COVID-19 LFT under real-world conditions. A total of 400 nasopharyngeal swab specimens with a wide range of viral loads were tested in both reverse-transcription polymerase chain reaction and ND LFT. The overall sensitivity and specificity were 85% (95% CI: 76.7–90.7%) and 100% (95% CI: 98.7–100%), respectively. There was a clear association between the false-negative rate and sample viral load: the sensitivity parameters for specimens with cycle threshold values of 3.95 × 106 copies/mL) and ≥30 (≤1.29 × 105 copies/mL) were 100% and 50%, respectively. The performance was maximized in testing samples with viral loads ≥1.29 × 105 copies/mL. These findings suggest that the ND LFT is sufficiently accurate and useful for mass population screening programs, especially in high-prevalence and resource-constrained settings or during periods when the epidemic curve is rising. Other public health implications were also discussed.
- Open Access
- 9 May 2022
- Published by MDPI AG in Gastrointestinal Disorders
- Vol. 4 (2) , 77-83
Response to COVID-19 Vaccination in Patients with Inflammatory Bowel Disease on Biological Treatment
Background: The antibody response to coronavirus disease 2019 (COVID-19) vaccination in patients with inflammatory bowel disease (IBD) on biological drugs is still unclear. Aim: To determine the anti-SARS-CoV-2 spike 1 (anti-S1-IgG) response rate and antibody levels following a complete COVID-19 vaccination cycle in patients with IBD on biological treatment. Methods: We assessed antibody response to COVID-19 in consecutive patients with IBD on biological drugs and without prior exposure to COVID-19. Sera were prospectively collected at baseline and at 21 days (T1), 42 days (T2), and 3 months (T3) after the first vaccine dose. Results: Among the 42 patients included in the study, the overall response rate at T3 was 97.6%, with no difference across the various biological drugs. After the first dose (T1), the response rate was higher in patients receiving anti-tumour necrosis factor (TNF) compared to patients treated with other biologics (p = 0.031). Among the responders, the anti-S1 levels were not significantly different among the various biological drugs at all study timepoints. Concomitant corticosteroids and disease activity had no impact on the response rate at all study timepoints. No unexpected side events were observed. Discussion: The antibody response to vaccination against COVID-19 in patients with IBD on biological drugs is optimal, independently of their mechanism of action. Patients treated with anti-TNF seem to have an earlier response to vaccination, while concomitant low-dose corticosteroids and disease activity does not seem to impact response. This information can be used to program vaccination and inform patients.
- 9 May 2022
- Published by MDPI AG in Gastrointestinal Disorders
- Vol. 4 (2) , 77-83
Open AccessResponse to COVID-19 Vaccination in Patients with Inflammatory Bowel Disease on Biological Treatment
Background: The antibody response to coronavirus disease 2019 (COVID-19) vaccination in patients with inflammatory bowel disease (IBD) on biological drugs is still unclear. Aim: To determine the anti-SARS-CoV-2 spike 1 (anti-S1-IgG) response rate and antibody levels following a complete COVID-19 vaccination cycle in patients with IBD on biological treatment. Methods: We assessed antibody response to COVID-19 in consecutive patients with IBD on biological drugs and without prior exposure to COVID-19. Sera were prospectively collected at baseline and at 21 days (T1), 42 days (T2), and 3 months (T3) after the first vaccine dose. Results: Among the 42 patients included in the study, the overall response rate at T3 was 97.6%, with no difference across the various biological drugs. After the first dose (T1), the response rate was higher in patients receiving anti-tumour necrosis factor (TNF) compared to patients treated with other biologics (p = 0.031). Among the responders, the anti-S1 levels were not significantly different among the various biological drugs at all study timepoints. Concomitant corticosteroids and disease activity had no impact on the response rate at all study timepoints. No unexpected side events were observed. Discussion: The antibody response to vaccination against COVID-19 in patients with IBD on biological drugs is optimal, independently of their mechanism of action. Patients treated with anti-TNF seem to have an earlier response to vaccination, while concomitant low-dose corticosteroids and disease activity does not seem to impact response. This information can be used to program vaccination and inform patients.
- Open Access
- 27 April 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (9) , 2465
Comparative Diagnostic Accuracy of the STANDARD M10 Assay for the Molecular Diagnosis of SARS-CoV-2 in the Point-of-Care and Critical Care Settings
Accurate and rapid molecular diagnosis of COVID-19 is a crucial step to tackle the ongoing pandemic. The primary objective of this study was to estimate the real-world performance of the novel RT-PCR STANDARD M10 SARS-CoV-2 assay in a large number of nasopharyngeal (NP) specimens eluted in universal transport medium. The secondary objective was to evaluate the compatibility of this kit in testing NP samples eluted in an inactivated transport medium (essential for point-of-care testing) and lower respiratory tract (LRT) specimens, which are commonly collected in critical care. A total of 591 samples were analyzed. Compared with the standard extraction-based RT-PCR Allplex 2019-nCoV (time-to-result of 270 min), the sensitivities of the STANDARD M10 were 100% (95% CI: 98.1–100%), 95.5% (95% CI: 91.7–97.6%), and 99.5% (95% CI: 97.2–99.9%) for ≥1 gene, the ORF1ab gene, and the E gene, respectively, while the specificity was 100% (95% CI: 98.7–100%). The diagnostic accuracy was 100% in testing both NP samples eluted in an inactivated transport medium and LRT specimens. STANDARD M10 reliably detects SARS-CoV-2 in 60 min, may be used as a POC tool, and is suitable for testing LRT specimens in the critical care setting.
- 27 April 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (9) , 2465
Open AccessComparative Diagnostic Accuracy of the STANDARD M10 Assay for the Molecular Diagnosis of SARS-CoV-2 in the Point-of-Care and Critical Care Settings
Accurate and rapid molecular diagnosis of COVID-19 is a crucial step to tackle the ongoing pandemic. The primary objective of this study was to estimate the real-world performance of the novel RT-PCR STANDARD M10 SARS-CoV-2 assay in a large number of nasopharyngeal (NP) specimens eluted in universal transport medium. The secondary objective was to evaluate the compatibility of this kit in testing NP samples eluted in an inactivated transport medium (essential for point-of-care testing) and lower respiratory tract (LRT) specimens, which are commonly collected in critical care. A total of 591 samples were analyzed. Compared with the standard extraction-based RT-PCR Allplex 2019-nCoV (time-to-result of 270 min), the sensitivities of the STANDARD M10 were 100% (95% CI: 98.1–100%), 95.5% (95% CI: 91.7–97.6%), and 99.5% (95% CI: 97.2–99.9%) for ≥1 gene, the ORF1ab gene, and the E gene, respectively, while the specificity was 100% (95% CI: 98.7–100%). The diagnostic accuracy was 100% in testing both NP samples eluted in an inactivated transport medium and LRT specimens. STANDARD M10 reliably detects SARS-CoV-2 in 60 min, may be used as a POC tool, and is suitable for testing LRT specimens in the critical care setting.
- Open Access
- 8 March 2022
- Published by MDPI AG in Pharmaceuticals
- Vol. 15 (3) , 322
COVID-19 and Seasonal Influenza Vaccination: Cross-Protection, Co-Administration, Combination Vaccines, and Hesitancy
SARS-CoV-2 and influenza are the main respiratory viruses for which effective vaccines are currently available. Strategies in which COVID-19 and influenza vaccines are administered simultaneously or combined into a single preparation are advantageous and may increase vaccination uptake. Here, we comprehensively review the available evidence on COVID-19/influenza vaccine co-administration and combination vaccine candidates from the standpoints of safety, immunogenicity, efficacy, policy and public acceptance. While several observational studies have shown that the trained immunity induced by influenza vaccines can protect against some COVID-19-related endpoints, it is not yet understood whether co-administration or combination vaccines can exert additive effects on relevant outcomes. In randomized controlled trials, co-administration has proved safe, with a reactogenicity profile similar to that of either vaccine administered alone. From the immunogenicity standpoint, the immune response towards four influenza strains and the SARS-CoV-2 spike protein in co-administration groups is generally non-inferior to that seen in groups receiving either vaccine alone. Several public health authorities have advocated co-administration. Different combination vaccine candidates are in (pre)-clinical development. The hesitancy towards vaccine co-administration or combination vaccines is a multifaceted phenomenon and may be higher than the acceptance of either vaccine administered separately. Public health implications are discussed.
- 8 March 2022
- Published by MDPI AG in Pharmaceuticals
- Vol. 15 (3) , 322
Open AccessCOVID-19 and Seasonal Influenza Vaccination: Cross-Protection, Co-Administration, Combination Vaccines, and Hesitancy
SARS-CoV-2 and influenza are the main respiratory viruses for which effective vaccines are currently available. Strategies in which COVID-19 and influenza vaccines are administered simultaneously or combined into a single preparation are advantageous and may increase vaccination uptake. Here, we comprehensively review the available evidence on COVID-19/influenza vaccine co-administration and combination vaccine candidates from the standpoints of safety, immunogenicity, efficacy, policy and public acceptance. While several observational studies have shown that the trained immunity induced by influenza vaccines can protect against some COVID-19-related endpoints, it is not yet understood whether co-administration or combination vaccines can exert additive effects on relevant outcomes. In randomized controlled trials, co-administration has proved safe, with a reactogenicity profile similar to that of either vaccine administered alone. From the immunogenicity standpoint, the immune response towards four influenza strains and the SARS-CoV-2 spike protein in co-administration groups is generally non-inferior to that seen in groups receiving either vaccine alone. Several public health authorities have advocated co-administration. Different combination vaccine candidates are in (pre)-clinical development. The hesitancy towards vaccine co-administration or combination vaccines is a multifaceted phenomenon and may be higher than the acceptance of either vaccine administered separately. Public health implications are discussed.
- Open Access
- 27 January 2022
- Published by MDPI AG in Microorganisms
- Vol. 10 (2) , 306
Comparative Analysis of Five Multiplex RT-PCR Assays in the Screening of SARS-CoV-2 Variants
The rapid and presumptive detection of SARS-CoV-2 variants may be performed using multiplex RT-PCR assays. The aim of this study was to evaluate the diagnostic performance of five qualitative RT-PCR tests as compared with next-generation sequencing (NGS). We retrospectively examined a multi-variant panel (n = 72) of SARS-CoV-2-positive nasopharyngeal swabs categorized as variants of concern (Alpha, Beta, Gamma and Delta), variants under monitoring (Iota and Kappa) and wild-type strains circulating in Liguria (Italy) from January to August 2021. First, NGS libraries of study samples were prepared and mapped to the reference genome. Then, specimens were screened for the detection of L452R, W152C, K417T, K417N, E484Q, E484K and N501Y mutations using the SARS-CoV-2 Variants II Assay Allplex, UltraGene Assay SARS-CoV-2 452R & 484K & 484Q Mutations V1, COVID-19 Ultra Variant Catcher, SARS-CoV-2 Extended ELITe MGB and Simplexa SARS-CoV-2 Variants Direct. The overall accuracy of these assays ranged from 96.9% to 100%. Specificity and sensitivity were 100% and 96–100%, respectively. We highly recommend the use of these assays as second-level tests in the routine workflow of SARS-CoV-2 laboratory diagnostics, as they are accurate, user friendly, low cost, may identify specific mutations in about 2–3 h and, therefore, optimize the surveillance of SARS-CoV-2 variants.
- 27 January 2022
- Published by MDPI AG in Microorganisms
- Vol. 10 (2) , 306
Open AccessComparative Analysis of Five Multiplex RT-PCR Assays in the Screening of SARS-CoV-2 Variants
The rapid and presumptive detection of SARS-CoV-2 variants may be performed using multiplex RT-PCR assays. The aim of this study was to evaluate the diagnostic performance of five qualitative RT-PCR tests as compared with next-generation sequencing (NGS). We retrospectively examined a multi-variant panel (n = 72) of SARS-CoV-2-positive nasopharyngeal swabs categorized as variants of concern (Alpha, Beta, Gamma and Delta), variants under monitoring (Iota and Kappa) and wild-type strains circulating in Liguria (Italy) from January to August 2021. First, NGS libraries of study samples were prepared and mapped to the reference genome. Then, specimens were screened for the detection of L452R, W152C, K417T, K417N, E484Q, E484K and N501Y mutations using the SARS-CoV-2 Variants II Assay Allplex, UltraGene Assay SARS-CoV-2 452R & 484K & 484Q Mutations V1, COVID-19 Ultra Variant Catcher, SARS-CoV-2 Extended ELITe MGB and Simplexa SARS-CoV-2 Variants Direct. The overall accuracy of these assays ranged from 96.9% to 100%. Specificity and sensitivity were 100% and 96–100%, respectively. We highly recommend the use of these assays as second-level tests in the routine workflow of SARS-CoV-2 laboratory diagnostics, as they are accurate, user friendly, low cost, may identify specific mutations in about 2–3 h and, therefore, optimize the surveillance of SARS-CoV-2 variants.
- Open Access
Comparative Diagnostic Performance of a Novel Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Kit for the Rapid Detection of SARS-CoV-2
Although the reverse transcription-polymerase chain reaction (RT-PCR) is considered a standard-of-care assay for the laboratory diagnosis of SARS-CoV-2, several limitations of this method have been described. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) is an alternative molecular assay and is potentially able to overcome some intrinsic shortcomings of RT-PCR. In this study, we evaluated the diagnostic performance of the novel HG COVID-19 RT-LAMP assay. In this retrospective analysis, a total of 400 routinely collected leftover nasopharyngeal samples with a known RT-PCR result were tested by means of the HG COVID-19 RT-LAMP assay. The overall sensitivity and specificity values of HG COVID-19 RT-LAMP versus RT-PCR were 97.0% (95% CI: 93.6–98.9%) and 98.5% (95% CI: 95.7–99.7%), respectively. Inter-assay agreement was almost perfect (κ = 0.96). Concordance was perfect in samples with high viral loads (cycle threshold < 30). The average time to a positive result on RT-LAMP was 17 min. HG COVID-19 RT-LAMP is a reliable molecular diagnostic kit for detecting SARS-CoV-2, and its performance is comparable to that of RT-PCR. Shorter turnaround times and the possibility of performing molecular diagnostics in the point-of-care setting make it a valuable option for facilities without sophisticated laboratory equipment.
Open AccessComparative Diagnostic Performance of a Novel Reverse Transcription Loop-Mediated Isothermal Amplification (RT-LAMP) Kit for the Rapid Detection of SARS-CoV-2
Although the reverse transcription-polymerase chain reaction (RT-PCR) is considered a standard-of-care assay for the laboratory diagnosis of SARS-CoV-2, several limitations of this method have been described. Reverse transcription loop-mediated isothermal amplification (RT-LAMP) is an alternative molecular assay and is potentially able to overcome some intrinsic shortcomings of RT-PCR. In this study, we evaluated the diagnostic performance of the novel HG COVID-19 RT-LAMP assay. In this retrospective analysis, a total of 400 routinely collected leftover nasopharyngeal samples with a known RT-PCR result were tested by means of the HG COVID-19 RT-LAMP assay. The overall sensitivity and specificity values of HG COVID-19 RT-LAMP versus RT-PCR were 97.0% (95% CI: 93.6–98.9%) and 98.5% (95% CI: 95.7–99.7%), respectively. Inter-assay agreement was almost perfect (κ = 0.96). Concordance was perfect in samples with high viral loads (cycle threshold < 30). The average time to a positive result on RT-LAMP was 17 min. HG COVID-19 RT-LAMP is a reliable molecular diagnostic kit for detecting SARS-CoV-2, and its performance is comparable to that of RT-PCR. Shorter turnaround times and the possibility of performing molecular diagnostics in the point-of-care setting make it a valuable option for facilities without sophisticated laboratory equipment.