Rajib Dey
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Rajib Dey has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Martin J. Leahy
The Institute of Photonic Sciences (ICFO)
3 shared publications - Sergey Alexandrov
National University of Ireland, Tissue Optics and Microcirculation Imaging, Galway
3 shared publications Andrew Nolan
Tissue Optics and Microcirculation Imaging Group, Physics School of Natural Sciences University of Galway Galway H91 CF50 Ireland
2 shared publications- Anand Arangath
Tissue Optics and Microcirculation Imaging Group, Physics School of Natural Sciences University of Galway Galway H91 CF50 Ireland
1 shared publication - Buddhadeb Oraon
Department of Mechanical Engineering, Jadavpur University, Kolkata 700032, West Bengal, India
1 shared publication - Igor Meglinski
Aston Univ. (United Kingdom)
1 shared publication
Latest Publications
- Open Access
- 28 January 2024
- Published by Wiley in Advanced Photonics Research
- Vol. 5 (4)
Synthetic Fourier Domain Optical Coherence Tomography
A novel approach for image formation in optical coherence tomography (OCT) and microscopy is presented. The depth resolution of OCT, including recently developed nanosensitive OCT (nsOCT), is limited by the spectral bandwidth of the light source used for illumination. The proposed approach, synthetic OCT (synOCT), permits label‐free, depth‐resolved quantitative visualization of the subwavelength‐sized structures with nanosensitivity. Using synOCT it is possible to estimate the contribution of axial Fourier components of an object's structure in image formation at each small volume within the image. The size of such areas can be smaller than the resolution limit of the imaging system that provides potential for super‐resolution imaging. Visualization of the subwavelength periodic structures and quantitative visualization of the subwavelength internal structures of highly scattering biological samples, within voxels smaller than resolution limit of the imaging system, are demonstrated. In contrast to nsOCT, the trade‐off between spectral and spatial resolution is removed which results in dramatic improvement of both spectral and spatial resolution in synOCT relative to nsOCT.
- 28 January 2024
- Published by Wiley in Advanced Photonics Research
- Vol. 5 (4)
Open AccessSynthetic Fourier Domain Optical Coherence Tomography
A novel approach for image formation in optical coherence tomography (OCT) and microscopy is presented. The depth resolution of OCT, including recently developed nanosensitive OCT (nsOCT), is limited by the spectral bandwidth of the light source used for illumination. The proposed approach, synthetic OCT (synOCT), permits label‐free, depth‐resolved quantitative visualization of the subwavelength‐sized structures with nanosensitivity. Using synOCT it is possible to estimate the contribution of axial Fourier components of an object's structure in image formation at each small volume within the image. The size of such areas can be smaller than the resolution limit of the imaging system that provides potential for super‐resolution imaging. Visualization of the subwavelength periodic structures and quantitative visualization of the subwavelength internal structures of highly scattering biological samples, within voxels smaller than resolution limit of the imaging system, are demonstrated. In contrast to nsOCT, the trade‐off between spectral and spatial resolution is removed which results in dramatic improvement of both spectral and spatial resolution in synOCT relative to nsOCT.
- Open Access
- 30 April 2023
- Published by Oriental Scientific Publishing Company in Oriental Journal of Chemistry
- Vol. 39 (2) , 246-254
Comparison of Coatings Adhesion Performances for Buried SS316L Pipelines
Oriental Journal of Chemistry is a peer reviewed quarterly research journal of pure and applied chemistry. It publishes standard research papers in almost all thrust areas of current chemistry of academic and commercial importance. It provides a platform for rapid publication of quality research papers, reviews and chemistry letters. Oriental Journal of Chemistry is abstracted and indexed in almost all reputed National and International agencies.
- 30 April 2023
- Published by Oriental Scientific Publishing Company in Oriental Journal of Chemistry
- Vol. 39 (2) , 246-254
Open AccessComparison of Coatings Adhesion Performances for Buried SS316L Pipelines
Oriental Journal of Chemistry is a peer reviewed quarterly research journal of pure and applied chemistry. It publishes standard research papers in almost all thrust areas of current chemistry of academic and commercial importance. It provides a platform for rapid publication of quality research papers, reviews and chemistry letters. Oriental Journal of Chemistry is abstracted and indexed in almost all reputed National and International agencies.
- Open Access
- 7 October 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (11) , 5654-5666
Skin cancer margin detection using nanosensitive optical coherence tomography and a comparative study with confocal microscopy
Excision biopsy and histology represent the gold standard for morphological investigation of the skin, in particular for cancer diagnostics. Nevertheless, a biopsy may alter the original morphology, usually requires several weeks for results, is non-repeatable on the same site and always requires an iatrogenic trauma. Hence, diagnosis and clinical management of diseases may be substantially improved by new non-invasive imaging techniques. Optical Coherence Tomography (OCT) is a non-invasive depth-resolved optical imaging modality based on low coherence interferometry that enables high-resolution, cross-sectional imaging in biological tissues and it can be used to obtain both structural and functional information. Beyond the resolution limit, it is not possible to detect structural and functional information using conventional OCT. In this paper, we present a recently developed technique, nanosensitive OCT (nsOCT), improved using broadband supercontinuum laser, and demonstrate nanoscale sensitivity to structural changes within ex vivo human skin tissue. The extended spectral bandwidth permitted access to a wider distribution of spatial frequencies and improved the dynamic range of the nsOCT. Firstly, we demonstrate numerical and experimental detection of a few nanometers structural difference using the nsOCT method from single B-scan images of phantoms with sub-micron periodic structures, acting like Bragg gratings, along the depth. Secondly, our study shows that nsOCT can distinguish nanoscale structural changes at the skin cancer margin from the healthy region in en face images at clinically relevant depths. Finally, we compare the nsOCT en face image with a high-resolution confocal microscopy image to confirm the structural differences between the healthy and lesional/cancerous regions, allowing the detection of the skin cancer margin.
- 7 October 2022
- Published by Optica Publishing Group in Biomedical Optics Express
- Vol. 13 (11) , 5654-5666
Open AccessSkin cancer margin detection using nanosensitive optical coherence tomography and a comparative study with confocal microscopy
Excision biopsy and histology represent the gold standard for morphological investigation of the skin, in particular for cancer diagnostics. Nevertheless, a biopsy may alter the original morphology, usually requires several weeks for results, is non-repeatable on the same site and always requires an iatrogenic trauma. Hence, diagnosis and clinical management of diseases may be substantially improved by new non-invasive imaging techniques. Optical Coherence Tomography (OCT) is a non-invasive depth-resolved optical imaging modality based on low coherence interferometry that enables high-resolution, cross-sectional imaging in biological tissues and it can be used to obtain both structural and functional information. Beyond the resolution limit, it is not possible to detect structural and functional information using conventional OCT. In this paper, we present a recently developed technique, nanosensitive OCT (nsOCT), improved using broadband supercontinuum laser, and demonstrate nanoscale sensitivity to structural changes within ex vivo human skin tissue. The extended spectral bandwidth permitted access to a wider distribution of spatial frequencies and improved the dynamic range of the nsOCT. Firstly, we demonstrate numerical and experimental detection of a few nanometers structural difference using the nsOCT method from single B-scan images of phantoms with sub-micron periodic structures, acting like Bragg gratings, along the depth. Secondly, our study shows that nsOCT can distinguish nanoscale structural changes at the skin cancer margin from the healthy region in en face images at clinically relevant depths. Finally, we compare the nsOCT en face image with a high-resolution confocal microscopy image to confirm the structural differences between the healthy and lesional/cancerous regions, allowing the detection of the skin cancer margin.
- Open Access
- 14 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 14 (1) , 1-11
Simple Characterization Scheme for Optical Coherence Tomography Systems With Application to a Commercial and a Near-Isometric Resolution Fibre-Based System
Optical Coherence Tomography (OCT) is a rapidly growing imaging modality in biomedical optics. OCT can perform high-resolution, cross-sectional imaging of the microstructure of biological tissues by measuring the coherent spectrum from the backscattered light. OCT systems with broad spectral bandwidths are often constructed using free-space optics to avoid dispersion by fibre optic components. This paper presents a fibre-based OCT system at a centre wavelength of 1300 nm with an axial resolution of 3.8 µm in air, surpassing any previously reported values to the best of our knowledge. Despite the challenges in transporting a broadband spectrum using fibre-optics, the system investigation was motivated by the ever-increasing demand for commercialization of high-resolution OCT systems and simplification of construction. We also evaluate and demonstrate the direct measurement method for axial resolution using an air wedge. Imaging of biomedical and other samples is demonstrated using a high numerical aperture sample lens and compared with images from a commercial OCT system. We discuss the effect of the improved structural visibility by achieving image voxels closer to an isometric shape with a high NA sample lens.
- 14 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Photonics Journal
- Vol. 14 (1) , 1-11
Open AccessSimple Characterization Scheme for Optical Coherence Tomography Systems With Application to a Commercial and a Near-Isometric Resolution Fibre-Based System
Optical Coherence Tomography (OCT) is a rapidly growing imaging modality in biomedical optics. OCT can perform high-resolution, cross-sectional imaging of the microstructure of biological tissues by measuring the coherent spectrum from the backscattered light. OCT systems with broad spectral bandwidths are often constructed using free-space optics to avoid dispersion by fibre optic components. This paper presents a fibre-based OCT system at a centre wavelength of 1300 nm with an axial resolution of 3.8 µm in air, surpassing any previously reported values to the best of our knowledge. Despite the challenges in transporting a broadband spectrum using fibre-optics, the system investigation was motivated by the ever-increasing demand for commercialization of high-resolution OCT systems and simplification of construction. We also evaluate and demonstrate the direct measurement method for axial resolution using an air wedge. Imaging of biomedical and other samples is demonstrated using a high numerical aperture sample lens and compared with images from a commercial OCT system. We discuss the effect of the improved structural visibility by achieving image voxels closer to an isometric shape with a high NA sample lens.
- 1 April 2018
- Published by Elsevier in Optics Communications
- Vol. 413, 172-178
Quantitative assessment of submicron scale anisotropy in tissue multifractality by scattering Mueller matrix in the framework of Born approximation
- 1 April 2018
- Published by Elsevier in Optics Communications
- Vol. 413, 172-178
Quantitative assessment of submicron scale anisotropy in tissue multifractality by scattering Mueller matrix in the framework of Born approximation