JCJames Caldwell

James Caldwell

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


James Caldwell has a total of 157 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Safety and efficacy of the Saccular Endovascular Aneurysm Lattice (SEAL) system for the treatment of wide neck bifurcation aneurysms: final 12 month results from the primary subgroup analysis of the Pre-SEAL First-in-Human Interventional Trial (Pre-SEAL IT)

    by Boris Pabón Guerrero, Victor Torres, Alexander Copelan, Syed F Zaidi, Hisham Salahuddin, Manuel Patiño, Andres Zapata, Jorge Mútis, Margarita Cardozo, Ammad Hussain, et al.

    Introduction Intrasaccular flow disrupters (IFDs) are increasingly used in endovascular management of intracranial wide neck bifurcation aneurysms (WNBAs). The next generation Saccular Endovascular Aneurysm Lattice (SEAL) system is a self-expanding, dual layered, braided nitinol IFD available in two configurations (SEAL Arc and SEAL Base) without a lead-in marker band. This primary subgroup analysis of the Pre-SEAL First-in-Human Interventional Trial (Pre-SEAL IT; NCT05686733) reports the final clinical and angiographic outcomes of the SEAL system in the management of WBNAs before the investigational device exemption (IDE) pre-marketing approval US based pivotal trial. Methods Pre-SEAL IT is a prospective, multicenter, single arm study, with US based independent imaging core lab adjudication. Primary safety endpoints were major periprocedural stroke, new subarachnoid hemorrhage, or neurologic death up to 12 months. Primary efficacy endpoints were complete (Raymond–Roy occlusion classification (RROC) 1 Woven EndoBridge occlusion scale (WOS) A or RROC 1 WOS B) or adequate occlusion (RROC 1 WOS A, RROC 1 WOS B, or RROC 2 WOS C) without parent artery compromise at 12 months. Results 13 WNBA aneurysms in 13 patients meeting similar inclusion and exclusion criteria to the Woven EndoBridge Intrasaccular Therapy (WEB-IT) IDE pivotal trial were included in this primary subgroup analysis. Technical success (device delivered and deployed as intended) was 100% (13/13). There were no major periprocedural strokes, new subarachnoid hemorrhages, or neurologic deaths. Independent core lab adjudication showed 11/13 patients (84.6%) achieved complete occlusion and 12/13 patients (92.3%) achieved adequate occlusion at 12 month follow-up. Conclusions SEAL intrasaccular flow disruption showed high technical success, an acceptable safety profile, and encouraging 12 month occlusion rates in the treatment of WNBAs.


  • Top Cited Papers
    Open Access

    SUMMIT MAX: A Randomized Trial of the Super Large Bore HiPoint Reperfusion System Versus Vecta System for Aspiration Thrombectomy

    by Thanh N. Nguyen, Guilherme Dabus, Ben McGuinness, James Caldwell, Ryan Priest, Ansaar T. Rai, Osama O. Zaidat, Bradley A. Gross, Ricardo Hanel, Shane Lee, et al.

    BACKGROUND: Rapid and complete recanalization is a primary goal in the endovascular treatment of large vessel occlusion stroke. The effectiveness and safety of super large bore aspiration catheters (0.088″ inner diameter) for the treatment of large vessel occlusion stroke have not been demonstrated in a randomized trial. METHODS: SUMMIT MAX (A Prospective, Randomized, Controlled, Interventional Clinical Trial to Evaluate the Safety and Effectiveness of the Route 92 Medical MonoPoint Reperfusion System for Aspiration Embolectomy in Acute Ischemic Stroke Patients) was a prospective, randomized, controlled, open-label clinical trial of patients with internal carotid artery and middle cerebral artery M1 occlusions, comparing the super large bore HiPoint Reperfusion system (Route 92 Medical) to the Vecta Aspiration system (Stryker Neurovascular). We hypothesized that the effectiveness and safety of the HiPoint reperfusion system were noninferior (12.5% noninferiority margin) to the Vecta Aspiration system. The primary effectiveness end point was successful reperfusion, defined as modified Treatment in Cerebral Infarction≥2b as adjudicated by an independent core lab, using only the assigned study device, with any use of a nonstudy device before or after the use of study device defined as failure. The primary safety end point was symptomatic intracranial hemorrhage within 24 hours (−8/+24) post-procedure. RESULTS: There were 250 patients enrolled of whom 166 met the criteria for the modified intent-to-treat population: 89 in HiPoint and 77 in Vecta. The median age was 69 years; 54.2% were female. Successful reperfusion with any adjunctive therapy counted as a failure was 77.5% (69/89) in the HiPoint group versus 50.6% (39/77) in the Vecta group ( P P =0.75). CONCLUSIONS: In this randomized trial of patients with anterior large vessel occlusion, the super large bore HiPoint system was noninferior to the Vecta system in achieving successful reperfusion, with a similar safety profile. This study supports the super large bore HiPoint system for mechanical thrombectomy. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT05018650.


  • Open Access

    Intracranial Dotter angioplasty using Tenzing (Tenzingplasty) for acute ischemic stroke with underlying intracranial atherosclerotic disease

    by Fabio Settecase, James Caldwell, Mubashir Pervez, Omar Kass-Hout, Warren T Kim, Rajkamal S Khangura, Matthew D Alexander, Amanda Baker, Nathan Farkas, Peter J Pema, et al.

    Introduction Catheter-mediated (Dotter) angioplasty has been previously described for extracranial/peripheral arteries. Tenzing (Route 92 Medical, San Mateo, California, USA), a shelf-reducing delivery catheter, has an atraumatic tapered distal tip that progressively enlarges to maximal outer diameter of 1.2 mm (Tenzing 5), 1.6 mm (Tenzing 7), and 2.1 mm (Tenzing 8). Objective To report our initial experience treating acutely symptomatic intracranial atherosclerotic disease (ICAD) using Dotter angioplasty with Tenzing (Tenzingplasty). Methods After institutional review board approvals, we retrospectively reviewed clinical and procedural data of patients with underlying ICAD treated with off-label Tenzingplasty between 2022 and 2025, either as part of endovascular treatment for large vessel occlusion, or after medical therapy failure Results We identified 53 consecutive patients with symptomatic ICAD who underwent Tenzingplasty, median (IQR) age 63 (57–70) years, 29 (55%) male. ICAD locations were: M1 (24), M2 (9), internal carotid artery (3), vertebral V4 segment (7), basilar (8), vertebrobasilar junction (1), and A2 anterior cerebral artery (1). First pass aspiration thrombectomy for patients with an initial modified Thrombolysis in Cerebral Infarction score 0 (without crossing the ICAD lesion) was performed in 34/53 (64%). After median 1 (IQR 1–2) Tenzingplasty pass, median (IQR) stenosis improved from 100% (95–100) to 60% (42–76) post-Tenzingplasty (PConclusion Tenzingplasty may be a feasible and safe rescue therapy for improving luminal caliber, flow restoration, and/or lesion preparation for stenting in acutely symptomatic ICAD.


  • Flow diverting stents in acutely ruptured intracranial aneurysms: a single centre experience of 40 consecutive cases

    by Jing Yi Liu, James Caldwell, Shane Lee, Matthew Page, Ben McGuinness

    Purpose Certain subsets of acutely ruptured intracranial aneurysms (IAs) may require treatment with flow diverting stents (FDS); however, use of FDS in this context warrants antiplatelet therapy which may increase the risk of further haemorrhage. Here we present our single centre experience of 40 consecutive patients. Methods We retrospectively reviewed our institutional databases for all patients between 2011 and 2024 with acutely ruptured IAs treated using FDS alone or with simultaneous coiling within 20 days of haemorrhage. Primary outcome was modified Rankin Score (mRS) at latest follow-up. Secondary outcomes were aneurysm occlusion rate and procedure-related complications. Results Forty patients met the inclusion criteria: 22 females; mean age 44.7 years (range 18–66). These included 28 blister-like, 5 fusiform, 4 dissecting and 3 saccular aneurysms, with 73% in the anterior circulation. Median time to FDS insertion was 1.5 days from ictus. Favourable functional outcome (mRS 0–2) was observed in 75%. Overall mortality rate was 13% and procedure-related mortality rate was 5%. Complete aneurysm occlusion rate was 97% on follow-up imaging. Procedure-related complications occurred in 18%, with 8% aneurysm rebleed rate, and 8% in-stent thrombosis rate on follow-up imaging (this group of three patients includes the only two patients treated with single antiplatelet therapy (SAPT)). Conclusion Our series yielded favourable clinical outcomes and excellent aneurysm occlusion rate following FDS treatment of ruptured IAs. Complications are not negligible, especially the thrombotic risk associated with SAPT use. However, given the innate high mortality risk of aneurysmal subarachnoid haemorrhage, FDS remain a useful alternative for aneurysms unsuitable for traditional endovascular treatment options.

  • Open Access

    Tenzing Assisted Delivery of Aspiration (TADA) technique for thrombectomy of medium vessel occlusions using the Freeclimb 54 catheter: multicenter experience

    by Fabio Settecase, Ajit S Puri, Shane Sh Lee, Rajkamal S Khangura, Ronald F Budzik, Peter J Pema, Thymur Chaudury, Matthew J Page, Ben J McGuinness, Marco Colasurdo, et al.

    Background Medium vessel occlusions (MeVOs) account for 25–40% of acute ischemic stroke. The Tenzing 5 (Route 92 Medical, San Mateo, California, USA) and FreeClimb 54 (Route 92 Medical, San Mateo, California, USA) catheter is a novel delivery–aspiration catheter combination designed to facilitate aspiration thrombectomy (AT) of MeVOs. We report our clinical experience using the Tenzing assisted delivery of aspiration (TADA) technique with FreeClimb 54 for first-line AT of MeVO. Methods We retrospectively reviewed consecutive patients who underwent MeVO first-line AT using TADA with FreeClimb 54 at nine institutions in the USA and one in New Zealand. Results 94 MeVOs (65 primary, 29 secondary) were treated in 92 patients: median age 71 (IQR 58–81) years; 49/92 (53%) women. FreeClimb 54 was successfully delivered by Tenzing 5 to all 94/94 MeVOs: 26 proximal M2; 44 distal M2; 5 M3; 6 A2; 4 A3; and 8 P2. Median target vessel diameter on DSA was 1.7 (IQR 1.4–1.8) mm. A leading microwire was used to advance Tenzing in 84% of cases. A stent retriever was used for additional thrombectomy passes in 6/94 (6%) patients. For a primary MeVO, final modified expanded Thrombolysis in Cerebral Infarction (meTICI) 2B–3 reperfusion was achieved in 63/65 (97%) patients, after a median of 1 (IQR 1–2) pass, with a first pass effect (FPE, meTICI 2C–3) in 43/65 (66%). Secondary MeVO FPE (eTICI 2C–3) was achieved in 20/29 (69%) patients. Tenzing 5–FreeClimb 54 related complications occurred in 2/94 (2%) patients: one perforation with asymptomatic subarachnoid hemorrhage and one embolus to new territory. Conclusions MeVO first-line AT using the TADA technique with Tenzing 5 and FreeClimb 54 had a high FPE with a low complication rate.


  • Open Access

    FreeClimb 88 catheter with Tenzing 8 delivery for contact aspiration mechanical thrombectomy of anterior circulation large vessel occlusions

    by Matthew D. Alexander, James Caldwell, Shane Sh Lee, Warren T. Kim, Joey D. English, Jaehyun Kim, Ben J. McGuinness, Matthew Page, Nebiyat F. Belachew, Jonathan A. Grossberg, et al.

    Purpose: Contact aspiration mechanical thrombectomy (CAMT) with 0.088-inch catheters may improve first-pass success rates, but delivery of such catheters can be challenging and limit effectiveness. This study examines the initial multicenter experience using the FreeClimb 88 catheter paired with the Tenzing 8 delivery catheter. Materials and Methods: Retrospective analysis was performed of consecutive patients with large vessel occlusion (LVO) of the internal carotid artery (ICA) or M1 segment of the middle cerebral artery treated with off-label CAMT using the FreeClimb 88 and Tenzing 8 at eight sites participating in the early limited release for these devices. Demographic and procedural variables were collected and analyzed with descriptive statistics and multivariable analysis. Results: Fifty-three consecutive patients were treated. Large vessel occlusion was located in the ICA in 19/53 (35.8%) patients; 34/53 (64.2%) were in the M1 segment. FreeClimb 88 was successfully delivered to the site of occlusion in 50/53 (94.3%) of patients. First-pass TICI 2c or 3 was achieved with FreeClimb 88 delivered by Tenzing 8 in 36 (67.9%) cases. Among cases with successful FreeClimb 88 delivery 9/50 (18.0%) required additional smaller devices to perform thrombectomy of distal occlusions after recanalization of the initial LVO. No complications or symptomatic hemorrhages occurred following thrombectomy. Conclusion: Contact aspiration mechanical thrombectomy performed for ICA or M1 LVOs using FreeClimb 88 delivered with Tenzing 8 was safe, effective, and efficient in this early experience, with first-pass TICI 2c or 3 was achieved in 68% of patients without procedural complications occurring in any cases.


  • Flow reversal during stroke thrombectomy

    by James Caldwell, Shane S H Lee, Mikal Sarrafzadeh, Dave S Rhodes, Ben J McGuinness

    When performing mechanical thrombectomy for stroke patients, some physicians use balloon guide catheters (BGCs) in order to achieve flow reversal and thereby improve reperfusion quality. There is substantial evidence favoring the use of BGCs to improve reperfusion rates and clinical outcomes for thrombectomy patients; however, as we will outline in this review, there is also evidence that BGCs do not achieve reliable flow reversal in many circumstances. Therefore, if we are able to modify our techniques to improve the likelihood of flow reversal during thrombectomy maneuvers, we may be able to further improve reperfusion quality and clinical outcomes. This paper provides an overview of concepts on this topic and outlines some potential techniques to facilitate flow reversal more consistently, including a method to visually confirm it, with the aim of making iterative improvements towards optimal reperfusion for stroke patients.


  • Open Access

    E-060 Improved catheter delivery to large vessel occlusions using tenzing 7 and freeclimb 70 catheters: initial multi-center experience

    by F Settecase, W Kim, J Kim, T Sivapatham, J Caldwell, S Lee, R Hixon, D Hoss, J English

    Introduction/Purpose Previous large vessel occlusion (LVO) comparative thrombectomy device trials reported a substantial rate of crossover from first line aspiration thrombectomy (AT) to stent-retriever (SR) thrombectomy. Use of 0.070 inch ‘large-bore’ catheters for AT is associated with increased aspiration flow rates, first pass effect, faster recanalization, reduced procedure time and better reperfusion rates. A 0.070 inch distal inner diameter catheter, FreeClimbTM 70 (Route 92, San Mateo, CA), was recently introduced and comes packaged with a specialized delivery catheter with a tapered distal tip, Tenzing® 7 (Route 92, San Mateo, CA), which significantly reduces the ledge or space between itself and the tip of the access catheter. This is especially important with increased caliber of ‘large bore’ catheters, which have a greater tendency to catch on arterial side branches and encounter increased friction in tortuous vascular anatomy. We report our initial multicenter experience using the FreeClimb 70 delivered over the Tenzing 7 catheter in the treatment of large vessel occlusion stroke. Materials and Methods After local IRB approval, we retrospectively reviewed and collected the clinical, procedural and imaging data of consecutive patients who underwent off-label AT with the FreeClimb 70 and Tenzing 7 at five institutions. The FreeClimb 70 and Tenzing 7 catheters were inserted as a unit into the guide catheter. After initial selective catheterization of the occluded vessel with Tenzing 7, the FreeClimb 70 was then advanced over the Tenzing catheter to the angiographic limit of contrast on roadmap angiography. The Tenzing was then removed and the FreeClimb 70 catheter was allowed to passively advance into the clot. Vacuum pump aspiration was then applied to the FreeClimb 70 for 2-5 minutes. Results FreeClimb 70 was successfully delivered over the Tenzing 7 to the target occlusion in 25/25 (100%) of cases (15 M1 segment, 5 M2, 4 ICA-terminus, and 1 basilar artery occlusions). No stent-retrievers were needed for delivery. Median time from groin puncture to first pass was 12 (IQR 8-16) minutes. In 20/25 (80%) cases, a leading microwire was not needed to advance the Tenzing 7 to the target occlusion. First pass effect (mTICI 2C or 3) was achieved in 13/25 (52%). For M1 MCA occlusions, FPE (mTICI 2C or 3) was 9/15 (60%). After a median of 1 (IQR 1-3) pass, successful reperfusion (mTICI ≥ 2B) was achieved in 24/25 (96%) cases, with complete reperfusion (2C or 3) in 22/25 (88%). After the first pass, additional clot retrieval devices were used in 10/25 (40%) cases, including SR in 2/25 (8%) cases. Median groin puncture to reperfusion time was 16 (IQR 12-28) minutes. There were no procedural complications or symptomatic intracranial hemorrhages. NIHSS at discharge decreased on average 8.5 ± 5.5 from presentation. There were three patient deaths: due to respiratory failure, oliguric renal failure, and transition to comfort care for large core infarct. Conclusions Initial clinical experience supports the use of the FreeClimb 70 catheter with Tenzing 7 for reliable access to intracranial LVO for rapid, effective and safe reperfusion. Further study is warranted. Disclosures F. Settecase: 2; C; Stryker, Route 92. W. Kim: 2; C; Stryker, Route 92. 4; C; Route 92. J. Kim: None. T. Sivapatham: None. J. Caldwell: None. S. Lee: None. R. Hixon: None. D. Hoss: None. J. English: 2; C; Stryker, Route 92. 4; C; Route 92.

  • Open Access

    Improved catheter delivery for aspiration thrombectomy using Tenzing 7 ledge reducing catheter and FreeClimb 70

    by Fabio Settecase, Warren T Kim, Thinesh Sivapatham, Rajkamal Khangura, James Caldwell, Shane Lee, H Robert Hixson, Daniel Hoss, Joey D English

    Purpose: Previous comparative mechanical thrombectomy device trials reported a substantial crossover rate from first-line aspiration to stent-retriever thrombectomy. A specialized delivery catheter may help track large-bore aspiration catheters to target occlusions. We report our multicenter experience of aspiration thrombectomy of intracranial large vessel occlusions using the FreeClimb TM 70 and Tenzing® 7 delivery catheter (Route 92, San Mateo, CA). Methods: After local Institutional Review Board approval, we retrospectively reviewed the clinical, procedural, and imaging data of patients who underwent mechanical thrombectomy with the FreeClimb 70 and Tenzing 7. Results: FreeClimb 70 was successfully delivered using Tenzing 7 to target occlusion in 30/30 (100%) patients (18 M1, 6 M2, 4 ICA-terminus, and 2 basilar artery occlusions), without the use of a stent-retriever for anchoring. In 21/30 (70%) cases, a leading microwire was not needed to advance the Tenzing 7 to the target. Median (interquartile range) time from groin puncture to first pass was 12 (interquartile range 8–15) minutes. Overall first pass effect, or first pass effect (modified thrombolysis in cerebral ischemia 2C-3), was achieved 16/30 (53%). For M1 occlusions, first pass effect was 11/18 (61%). Successful reperfusion (modified thrombolysis in cerebral ischemia ≥ 2B) was achieved in 29/30 (97%) cases after a median of 1 pass (interquartile range 1–3). Median groin puncture to reperfusion time was 16 (interquartile range 12–26) minutes. There were no procedural complications or symptomatic intracranial hemorrhage. Average improvement in National Institutes of Health Stroke Scale at discharge was 6.6 ± 7.1. There were three patient deaths (renal failure, respiratory failure, and comfort care). Conclusions: Initial data support the use of Tenzing 7 with FreeClimb 70 catheter for reliable access to rapid, effective, and safe aspiration thrombectomy of large vessel occlusions.