Seyyed Mostafa Mousavi Janbeh Sarayi
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Seyyed Mostafa Mousavi Janbeh Sarayi has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
- Iakovos Toumazis
Department of Health Services Research The University of Texas MD Anderson Cancer Center Houston Texas USA
2 shared publications - Vincent M. Tutino
Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY, USA
2 shared publications Adnan H. Siddiqui
Canon Stroke and Vascular Research Center, University at Buffalo, Buffalo, NY 14203, USA
1 shared publication- Adnan H. Siddiqui
Department of Neurosurgery, State University of New York at Buffalo, Buffalo, New York, USA
1 shared publication Alex Elliott
Computational Applied Mathematics and Operations Research, Rice University
1 shared publicationAlexandria Scotti
1 shared publication
Latest Publications
- 1 March 2026
- Published by Wolters Kluwer Health in The Cancer Journal
- Vol. 32 (2)
Economic Evaluation of Particle Therapy for Cancer Treatment: A Systematic Review
Particle therapy represents a cutting-edge modality in radiation oncology that offers potential advantages over conventional radiation therapy; however, its cost-effectiveness has not been established. We conducted a systematic search of several electronic databases to synthesize contemporary evidence on the cost-effectiveness of particle therapy. The methodological quality of the included studies was assessed, and reported outcomes on costs, health benefits, and incremental cost-effectiveness ratios (ICERs) were extracted. We identified 57 studies, which collectively reported 134 comparisons for particle therapies. In general, studies were of good quality, although better reporting of data sources and modeling assumptions is warranted. Included studies primarily evaluated the cost-effectiveness of proton therapy, used photon therapy as the comparator, utilized a Markov Cohort model, and used the payer’s perspective. Findings were inconsistent, with the reported ICERs ranging from $55 to $1,066,266 per unit of benefit gained, with discrepancies across cancer sites and treatment modalities. Particle therapy is cost-effective for specific groups but may not be universally cost-effective. More research is warranted to identify subgroups for which particle therapy is cost-effective.
- 1 March 2026
- Published by Wolters Kluwer Health in The Cancer Journal
- Vol. 32 (2)
Economic Evaluation of Particle Therapy for Cancer Treatment: A Systematic Review
Particle therapy represents a cutting-edge modality in radiation oncology that offers potential advantages over conventional radiation therapy; however, its cost-effectiveness has not been established. We conducted a systematic search of several electronic databases to synthesize contemporary evidence on the cost-effectiveness of particle therapy. The methodological quality of the included studies was assessed, and reported outcomes on costs, health benefits, and incremental cost-effectiveness ratios (ICERs) were extracted. We identified 57 studies, which collectively reported 134 comparisons for particle therapies. In general, studies were of good quality, although better reporting of data sources and modeling assumptions is warranted. Included studies primarily evaluated the cost-effectiveness of proton therapy, used photon therapy as the comparator, utilized a Markov Cohort model, and used the payer’s perspective. Findings were inconsistent, with the reported ICERs ranging from $55 to $1,066,266 per unit of benefit gained, with discrepancies across cancer sites and treatment modalities. Particle therapy is cost-effective for specific groups but may not be universally cost-effective. More research is warranted to identify subgroups for which particle therapy is cost-effective.
- 31 October 2025
- Published by Elsevier in International Journal of Gynecological Cancer
- Vol. 36 (5) , 102771
Improving ovarian cancer risk assessment using a machine learning model developed on data from the Prostate Lung Colorectal Ovarian Cancer Screening Trial
- 31 October 2025
- Published by Elsevier in International Journal of Gynecological Cancer
- Vol. 36 (5) , 102771
Improving ovarian cancer risk assessment using a machine learning model developed on data from the Prostate Lung Colorectal Ovarian Cancer Screening Trial
- Open Access
CT Radiomic Signatures of Neutrophil Extracellular Traps in Ischemic Stroke Thrombi
Background: Radiomic and transcriptomic analyses have independently identified features linked to mechanical thrombectomy (MT) outcomes in acute ischemic stroke (AIS). In this study, we integrate paired radiomic and transcriptomic profiling of AIS clots to identify Neutrophil Extracellular Trap (NET) enrichment as a predictor of first-pass MT success. We further assess the potential to non-invasively detect NET enrichment using pre-thrombectomy CT imaging. Methods: We performed radiomic and transcriptomic analysis of 32 stroke clots retrieved by MT (n=16 each of modified first pass [mFP] success and failure). Clots were segmented from pre-MT CTA and nCCT scans and radiomic features (RFs) were extracted using pyRadiomics. Normality, equal variance, and two-sample testing were completed to identify which RFs were significantly different between mFP outcomes. Differentially expressed genes (DEGs) were identified between transcriptomes of mFP success and failure using the criteria of logFC≥1.5 and q<0.05. A NET enrichment score was computed from expression data and correlated with RFs to identify a RF signature predictive of NET enrichment. Immunofluorescence (IF) staining was completed on retrieved clot tissue to provide ground truth labeling of NETs. Results: 44 DEGs were identified between mFP outcomes. From ontology analysis, NET Formation, Neutrophil Degranulation, and the NET Signaling Pathway were among the most enriched terms in the mFP failure group, with related genes downregulated in the mFP success group. 40 RFs were significantly different between mFP outcomes. Of these, 6 were found to be correlated with and predictive of clot NET enrichment. IF quantification validated that transcriptomic NET signatures accurately reflected NET presence within clot tissues. Conclusion: Our findings indicate that NET enrichment within thrombi is associated with reduced mFP success, and that radiomic features extracted from pre-thrombectomy CT imaging can serve as non-invasive biomarkers of clot NET content. This radiomic signature may aid in pre-procedural decision-making, including thrombolytic therapy planning and thrombectomy device selection.
Open AccessCT Radiomic Signatures of Neutrophil Extracellular Traps in Ischemic Stroke Thrombi
Background: Radiomic and transcriptomic analyses have independently identified features linked to mechanical thrombectomy (MT) outcomes in acute ischemic stroke (AIS). In this study, we integrate paired radiomic and transcriptomic profiling of AIS clots to identify Neutrophil Extracellular Trap (NET) enrichment as a predictor of first-pass MT success. We further assess the potential to non-invasively detect NET enrichment using pre-thrombectomy CT imaging. Methods: We performed radiomic and transcriptomic analysis of 32 stroke clots retrieved by MT (n=16 each of modified first pass [mFP] success and failure). Clots were segmented from pre-MT CTA and nCCT scans and radiomic features (RFs) were extracted using pyRadiomics. Normality, equal variance, and two-sample testing were completed to identify which RFs were significantly different between mFP outcomes. Differentially expressed genes (DEGs) were identified between transcriptomes of mFP success and failure using the criteria of logFC≥1.5 and q<0.05. A NET enrichment score was computed from expression data and correlated with RFs to identify a RF signature predictive of NET enrichment. Immunofluorescence (IF) staining was completed on retrieved clot tissue to provide ground truth labeling of NETs. Results: 44 DEGs were identified between mFP outcomes. From ontology analysis, NET Formation, Neutrophil Degranulation, and the NET Signaling Pathway were among the most enriched terms in the mFP failure group, with related genes downregulated in the mFP success group. 40 RFs were significantly different between mFP outcomes. Of these, 6 were found to be correlated with and predictive of clot NET enrichment. IF quantification validated that transcriptomic NET signatures accurately reflected NET presence within clot tissues. Conclusion: Our findings indicate that NET enrichment within thrombi is associated with reduced mFP success, and that radiomic features extracted from pre-thrombectomy CT imaging can serve as non-invasive biomarkers of clot NET content. This radiomic signature may aid in pre-procedural decision-making, including thrombolytic therapy planning and thrombectomy device selection.
- Open Access
- 15 December 2021
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 18 (185)
Realistic computer modelling of stent retriever thrombectomy: a hybrid finite-element analysis-smoothed particle hydrodynamics model
Stent retriever thrombectomy is a pre-eminent treatment modality for large vessel ischaemic stroke. Simulation of thrombectomy could help understand stent and clot mechanics in failed cases and provide a digital testbed for the development of new, safer devices. Here, we present a novel, in silico thrombectomy method using a hybrid finite-element analysis (FEA) and smoothed particle hydrodynamics (SPH). Inspired by its biological structure and components, the blood clot was modelled with the hybrid FEA–SPH method. The Solitaire self-expanding stent was parametrically reconstructed from micro-CT imaging and was modelled as three-dimensional finite beam elements. Our simulation encompassed all steps of mechanical thrombectomy, including stent packaging, delivery and self-expansion into the clot, and clot extraction. To test the feasibility of our method, we simulated clot extraction in simple straight vessels. This was compared against in vitro thrombectomies using the same stent, vessel geometry, and clot size and composition. Comparisons with benchtop tests indicated that our model was able to accurately simulate clot deflection and penetration of stent wires into the clot, the relative movement of the clot and stent during extraction, and clot fragmentation/embolus formation. In this study, we demonstrated that coupling FEA and SPH techniques could realistically model stent retriever thrombectomy.
- 15 December 2021
- Published by The Royal Society in Journal of The Royal Society Interface
- Vol. 18 (185)
Open AccessRealistic computer modelling of stent retriever thrombectomy: a hybrid finite-element analysis-smoothed particle hydrodynamics model
Stent retriever thrombectomy is a pre-eminent treatment modality for large vessel ischaemic stroke. Simulation of thrombectomy could help understand stent and clot mechanics in failed cases and provide a digital testbed for the development of new, safer devices. Here, we present a novel, in silico thrombectomy method using a hybrid finite-element analysis (FEA) and smoothed particle hydrodynamics (SPH). Inspired by its biological structure and components, the blood clot was modelled with the hybrid FEA–SPH method. The Solitaire self-expanding stent was parametrically reconstructed from micro-CT imaging and was modelled as three-dimensional finite beam elements. Our simulation encompassed all steps of mechanical thrombectomy, including stent packaging, delivery and self-expansion into the clot, and clot extraction. To test the feasibility of our method, we simulated clot extraction in simple straight vessels. This was compared against in vitro thrombectomies using the same stent, vessel geometry, and clot size and composition. Comparisons with benchtop tests indicated that our model was able to accurately simulate clot deflection and penetration of stent wires into the clot, the relative movement of the clot and stent during extraction, and clot fragmentation/embolus formation. In this study, we demonstrated that coupling FEA and SPH techniques could realistically model stent retriever thrombectomy.