Charles Houdeville
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Charles Houdeville has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Xavier Dray
Sorbonne University, Center for Digestive Endoscopy, Saint-Antoine Hospital, APHP, 75012 Paris, France; Équipes Traitement de l'Information et Systèmes, ETIS UMR 8051, CY Paris Cergy University, ENSEA, CNRS, 95000 Cergy, France
2 shared publications- Alexandre Nuzzo
Department of Gastroenterology, IBD and Intestinal Failure, Beaujon Hospital, AP-HP, Clichy, France
1 shared publication Aymeric Histace
Équipes Traitement de l'Information et Systèmes, ETIS UMR 8051, CY Paris Cergy University, ENSEA, CNRS, 95000 Cergy, France
1 shared publication- Aymeric Histace
ENSEA, ETIS UMR 8051 (CY Paris Cergy University, ENSEA, CNRS)
1 shared publication Bettina Fabiani
Sorbonne Université, Département of Pathologie, Hôpital Saint-Antoine, APHP, Paris, France
1 shared publicationGuillaume Velut
Sorbonne University, Center for Digestive Endoscopy, Saint-Antoine Hospital, APHP, 75012 Paris, France; Department of Gastroenterology CHU Nantes, Hotel Dieu, Nantes, France
1 shared publication
Latest Publications
- 30 November 2024
- Published by Elsevier in Clinics and Research in Hepatology and Gastroenterology
- Vol. 49 (1) , 102509
Toward automated small bowel capsule endoscopy reporting using a summarizing machine learning algorithm: The SUM UP study
- 30 November 2024
- Published by Elsevier in Clinics and Research in Hepatology and Gastroenterology
- Vol. 49 (1) , 102509
Toward automated small bowel capsule endoscopy reporting using a summarizing machine learning algorithm: The SUM UP study
- 26 January 2024
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 119 (5) , 792
A Rare Complication of a Benign Pancreatic Tumor
An abstract is unavailable. This article is available as a PDF only.
- 26 January 2024
- Published by Wolters Kluwer Health in American Journal of Gastroenterology
- Vol. 119 (5) , 792
A Rare Complication of a Benign Pancreatic Tumor
An abstract is unavailable. This article is available as a PDF only.
- Open Access
- 17 May 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (10) , 2822
Evaluation by a Machine Learning System of Two Preparations for Small Bowel Capsule Endoscopy: The BUBS (Burst Unpleasant Bubbles with Simethicone) Study
Background: Bubbles often mask the mucosa during capsule endoscopy (CE). Clinical scores assessing the cleanliness and the amount of bubbles in the small bowel (SB) are poorly reproducible unlike machine learning (ML) solutions. We aimed to measure the amount of bubbles with ML algorithms in SB CE recordings, and compare two polyethylene glycol (PEG)-based preparations, with and without simethicone, in patients with obscure gastro-intestinal bleeding (OGIB). Patients & Methods: All consecutive outpatients with OGIB from a tertiary care center received a PEG-based preparation, without or with simethicone, in two different periods. The primary outcome was a difference in the proportions (%) of frames with abundant bubbles (>10%) along the full-length video sequences between the two periods. SB CE recordings were analyzed by a validated computed algorithm based on a grey-level of co-occurrence matrix (GLCM), to assess the abundance of bubbles in each frame. Results: In total, 105 third generation SB CE recordings were analyzed (48 without simethicone and 57 with simethicone-added preparations). A significant association was shown between the use of a simethicone-added preparation and a lower abundance of bubbles along the SB (p = 0.04). A significantly lower proportion of “abundant in bubbles” frames was observed in the fourth quartile (30.5% vs. 20.6%, p = 0.02). There was no significant impact of the use of simethicone in terms of diagnostic yield, SB transit time and completion rate. Conclusion: An accurate and reproducible computed algorithm demonstrated significant decrease in the abundance of bubbles along SB CE recordings, with a marked effect in the last quartile, in patients for whom simethicone had been added in PEG-based preparations, compared to those without simethicone.
- 17 May 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (10) , 2822
Open AccessEvaluation by a Machine Learning System of Two Preparations for Small Bowel Capsule Endoscopy: The BUBS (Burst Unpleasant Bubbles with Simethicone) Study
Background: Bubbles often mask the mucosa during capsule endoscopy (CE). Clinical scores assessing the cleanliness and the amount of bubbles in the small bowel (SB) are poorly reproducible unlike machine learning (ML) solutions. We aimed to measure the amount of bubbles with ML algorithms in SB CE recordings, and compare two polyethylene glycol (PEG)-based preparations, with and without simethicone, in patients with obscure gastro-intestinal bleeding (OGIB). Patients & Methods: All consecutive outpatients with OGIB from a tertiary care center received a PEG-based preparation, without or with simethicone, in two different periods. The primary outcome was a difference in the proportions (%) of frames with abundant bubbles (>10%) along the full-length video sequences between the two periods. SB CE recordings were analyzed by a validated computed algorithm based on a grey-level of co-occurrence matrix (GLCM), to assess the abundance of bubbles in each frame. Results: In total, 105 third generation SB CE recordings were analyzed (48 without simethicone and 57 with simethicone-added preparations). A significant association was shown between the use of a simethicone-added preparation and a lower abundance of bubbles along the SB (p = 0.04). A significantly lower proportion of “abundant in bubbles” frames was observed in the fourth quartile (30.5% vs. 20.6%, p = 0.02). There was no significant impact of the use of simethicone in terms of diagnostic yield, SB transit time and completion rate. Conclusion: An accurate and reproducible computed algorithm demonstrated significant decrease in the abundance of bubbles along SB CE recordings, with a marked effect in the last quartile, in patients for whom simethicone had been added in PEG-based preparations, compared to those without simethicone.