Xinyue Song
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Xinyue Song has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Sen Yan
Xi’an Jiaotong University
5 shared publications - Guy A. E. Vandenbosch
Department of Electrical Engineering (ESAT), KU Leuven, Leuven, Belgium
2 shared publications - Chen Chen
School of Microelectronics, Xian Jiaotong University, Xian, China
1 shared publication - Feng Liang
School of Microelectronics, Xian Jiaotong University, Xian, China
1 shared publication - Hongyi Wang
School of Microelectronics, Xi’an Jiaotong University, Xi’an, China
1 shared publication - Jianxing Li
Xi’an Jiaotong University
1 shared publication
Latest Publications
- 24 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
Coupled Mode Theory-Inspired Design of Ultrasensitive Planar Biosensor Based on SIW Resonator
This paper proposes a highly compact and ultra-sensitive microfluidic sensor based on the cavity resonator for biofluids. Aiming at the problem that cavity sensors under planar channels have difficulty achieving high sensitivity, a simple and efficient design method based on coupled mode theory(CMT) is proposed, and a highly miniaturized device is optimized based on the proposed concept. Instead of the drilled channel of a typical substrate integrated waveguide (SIW) cavity with a top and bottom metal layer, the proposed resonator is based on a planar integration of the channel. An additional patch resonator is introduced in the cavity center for establishing a coupled resonator system. The high sensitivity is obtained by mode splitting generated from the strong coupling of the SIW resonator and the introduced patch resonator. The miniaturization strategies of folded SIW and spiral complementary split ring resonator (CSRR) are applied to the two coupled resonators, respectively, to put the channel position at maximum field levels. The highly miniaturized device reduces the amount of necessary fluid during testing while maintaining the performance. The sensor is operational in the frequency range 0.6-1.7 GHz and has a size 0.21 × 0.21 λ2 at 1.7 GHz. The proposed sensor has been verified with sodium chloride solutions to emulate the concentration range of sweat under physiological conditions. The results demonstrated that the sensor provides excellent resolution, thereby confirming its suitability for biological fluid analysis.
- 24 December 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 75 (00189456) , 1-12
Coupled Mode Theory-Inspired Design of Ultrasensitive Planar Biosensor Based on SIW Resonator
This paper proposes a highly compact and ultra-sensitive microfluidic sensor based on the cavity resonator for biofluids. Aiming at the problem that cavity sensors under planar channels have difficulty achieving high sensitivity, a simple and efficient design method based on coupled mode theory(CMT) is proposed, and a highly miniaturized device is optimized based on the proposed concept. Instead of the drilled channel of a typical substrate integrated waveguide (SIW) cavity with a top and bottom metal layer, the proposed resonator is based on a planar integration of the channel. An additional patch resonator is introduced in the cavity center for establishing a coupled resonator system. The high sensitivity is obtained by mode splitting generated from the strong coupling of the SIW resonator and the introduced patch resonator. The miniaturization strategies of folded SIW and spiral complementary split ring resonator (CSRR) are applied to the two coupled resonators, respectively, to put the channel position at maximum field levels. The highly miniaturized device reduces the amount of necessary fluid during testing while maintaining the performance. The sensor is operational in the frequency range 0.6-1.7 GHz and has a size 0.21 × 0.21 λ2 at 1.7 GHz. The proposed sensor has been verified with sodium chloride solutions to emulate the concentration range of sweat under physiological conditions. The results demonstrated that the sensor provides excellent resolution, thereby confirming its suitability for biological fluid analysis.
- 19 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (6) , 9608-9617
An Enhanced Microwave Differential Microfluidic Sensing System for Detecting Small Variation of Dielectric Properties
This paper proposes a microwave sensor based on differential structure to detect small changes in the dielectric properties of biological microfluids. By examining the underlying operating principles of the differential sensing system, the key factors influencing sensor performance are identified. The proposed design enhances sensitivity by optimizing both the sensing branches and the overall configuration. Two coupled eighth-mode (EM) substrate-integrated waveguide (SIW) resonators with concentrated electric field tips are employed in the sensing branches, which exhibit rapid phase variation as the sample under test (SUT) changes, thereby improving the sensitivity of the original differential zero point. Furthermore, the introduction of an additional zero point caused by self-resonance achieves double increase in sensor sensitivity within a narrow frequency band. The sensor operates in the frequency range of 4.7-5.7 GHz, and its performance has been validated using ethanol-water solution with varying concentrations to simulate the subtle changes in biofluids under physiological conditions. The proposed structure offers a potential solution to the sensitivity challenges posed by subtle changes of high dielectric permittivity samples in biosensing.
- 19 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 25 (6) , 9608-9617
An Enhanced Microwave Differential Microfluidic Sensing System for Detecting Small Variation of Dielectric Properties
This paper proposes a microwave sensor based on differential structure to detect small changes in the dielectric properties of biological microfluids. By examining the underlying operating principles of the differential sensing system, the key factors influencing sensor performance are identified. The proposed design enhances sensitivity by optimizing both the sensing branches and the overall configuration. Two coupled eighth-mode (EM) substrate-integrated waveguide (SIW) resonators with concentrated electric field tips are employed in the sensing branches, which exhibit rapid phase variation as the sample under test (SUT) changes, thereby improving the sensitivity of the original differential zero point. Furthermore, the introduction of an additional zero point caused by self-resonance achieves double increase in sensor sensitivity within a narrow frequency band. The sensor operates in the frequency range of 4.7-5.7 GHz, and its performance has been validated using ethanol-water solution with varying concentrations to simulate the subtle changes in biofluids under physiological conditions. The proposed structure offers a potential solution to the sensitivity challenges posed by subtle changes of high dielectric permittivity samples in biosensing.
- 19 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Technology Letters
- Vol. 33 (1) , 94-97
A Design of Metamaterial Inspired Resonator for Multifrequency Fluidic Sensors
This letter presents a multifrequency planar resonator fed by coplanar waveguide (CPW) for the determination of dispersive fluidic materials. By employing composite right-/left-handed transmission line (CRLH TL) in the resonator, the characteristic of multiresonance has been achieved in a compact size (0.17 $\times$ 0.15 $\lambda_{0}^{2}$ ), which can enhance the sensitivity of the resonator as a sensor at multiple frequencies. The substrate is integrated with a fluidic container made of polydimethylsiloxane (PDMS). The optimum design operates at 2.28, 2.95, and 10.6 GHz to cover both the lower and the higher frequency bands. Also, it shows very good sensitivity (0.98, 0.7, and 0.67) at each resonant frequency. Deionized water at different temperatures and water–ethanol mixtures are used to verify the performance of the sensor in multiple frequency bands. The advantages of the proposed design, including compact size, multifrequency resonances, and high sensitivity, make it a competitive solution for detecting biological samples with similar electromagnetic properties in a single-frequency band.
- 19 September 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Technology Letters
- Vol. 33 (1) , 94-97
A Design of Metamaterial Inspired Resonator for Multifrequency Fluidic Sensors
This letter presents a multifrequency planar resonator fed by coplanar waveguide (CPW) for the determination of dispersive fluidic materials. By employing composite right-/left-handed transmission line (CRLH TL) in the resonator, the characteristic of multiresonance has been achieved in a compact size (0.17 $\times$ 0.15 $\lambda_{0}^{2}$ ), which can enhance the sensitivity of the resonator as a sensor at multiple frequencies. The substrate is integrated with a fluidic container made of polydimethylsiloxane (PDMS). The optimum design operates at 2.28, 2.95, and 10.6 GHz to cover both the lower and the higher frequency bands. Also, it shows very good sensitivity (0.98, 0.7, and 0.67) at each resonant frequency. Deionized water at different temperatures and water–ethanol mixtures are used to verify the performance of the sensor in multiple frequency bands. The advantages of the proposed design, including compact size, multifrequency resonances, and high sensitivity, make it a competitive solution for detecting biological samples with similar electromagnetic properties in a single-frequency band.
- 28 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 6 (3) , 391-398
A Sensitivity-Enhanced Sensor Based on Zeroth-Order Resonance for Liquid Characterization
A high-sensitivity planar microfluidic sensor is proposed in this paper based on composite left/right-handed transmission line (CRLH TL). By employing the series zeroth-order resonance (ZOR), the resonance of proposed sensor is only determined by surface capacitance and inductance. The short-circuit structure reduces the energy loss due to edge radiation and generates a highly concentrated electric field on the top surface of the substrate, which can be used to detect the dielectric loading samples. The presented sensor has been simulated, fabricated and tested. The sensor on the printed circuit board (PCB) is integrated with the fluidic container made of polydimethylsiloxane (PDMS) to form the test device. The water-ethanol binary mixture and sucrose solution are used to proof the concept. Finally, the prediction model for the water-ethanol mixture based on measured parameters has been established and the analysis of prediction error has been carried out. The sensor works around 4 GHz, and the maximum sensitivity reaches 1.04. Due to the high sensitivity and simple structure, the proposed structure is a competitive candidate for the applications including bio-sensing and portable biomedical device.
- 28 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology
- Vol. 6 (3) , 391-398
A Sensitivity-Enhanced Sensor Based on Zeroth-Order Resonance for Liquid Characterization
A high-sensitivity planar microfluidic sensor is proposed in this paper based on composite left/right-handed transmission line (CRLH TL). By employing the series zeroth-order resonance (ZOR), the resonance of proposed sensor is only determined by surface capacitance and inductance. The short-circuit structure reduces the energy loss due to edge radiation and generates a highly concentrated electric field on the top surface of the substrate, which can be used to detect the dielectric loading samples. The presented sensor has been simulated, fabricated and tested. The sensor on the printed circuit board (PCB) is integrated with the fluidic container made of polydimethylsiloxane (PDMS) to form the test device. The water-ethanol binary mixture and sucrose solution are used to proof the concept. Finally, the prediction model for the water-ethanol mixture based on measured parameters has been established and the analysis of prediction error has been carried out. The sensor works around 4 GHz, and the maximum sensitivity reaches 1.04. Due to the high sensitivity and simple structure, the proposed structure is a competitive candidate for the applications including bio-sensing and portable biomedical device.
- 31 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems
- Vol. 41 (11) , 4808-4820
High-Dimensional Bayesian Optimization for Analog Integrated Circuit Sizing Based on Dropout and gm/ID Methodology
Bayesian optimization (BO) is popular for a analog circuit sizing problem recently. However, BO can only work well in small-scale circuit. Scaling BO to common circuit optimization (typically dimension > 10) is difficult due to the curse of dimensionality. In this article, we proposed a new BO algorithm (cBO), which can scale BO to more larger scale circuit and improve the optimization result. First, according to the fact that a specification of the analog integrated circuit is mainly determined by a few transistors, dropout strategy is adopted in our algorithm. At each iteration, only a subset of selected variables to be optimized. A variables selection strategy based on mutual information analysis and a new fill-in strategy are proposed. Second, the $g_{m}/I_{D}$ methodology-based optimization strategy is proposed. Optimization variables are not width and the length of transistors, but $g_{m}/I_{D}$ , $I_{D}$ and length. $g_{m}$ , $I_{D}$ and $g_{m}/I_{D}$ have a direct relationship to circuit performance. This is equivalent to search in circuit feature space, which could achieve better performance and handle constraints more easily. Four commonly used circuits, including low dropout regulator, two stage amplifiers, Bandgap voltage reference (VR), and VR are used for validation. Compared with other high-dimensional BO, common BO, and commercial tools (Cadence ADE_GXL), the proposed algorithm is found to produce the best optimization result and best stability. And, the ablation study shows the effectiveness and efficiency of two ingredients of the proposed algorithm.
- 31 January 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems
- Vol. 41 (11) , 4808-4820
High-Dimensional Bayesian Optimization for Analog Integrated Circuit Sizing Based on Dropout and gm/ID Methodology
Bayesian optimization (BO) is popular for a analog circuit sizing problem recently. However, BO can only work well in small-scale circuit. Scaling BO to common circuit optimization (typically dimension > 10) is difficult due to the curse of dimensionality. In this article, we proposed a new BO algorithm (cBO), which can scale BO to more larger scale circuit and improve the optimization result. First, according to the fact that a specification of the analog integrated circuit is mainly determined by a few transistors, dropout strategy is adopted in our algorithm. At each iteration, only a subset of selected variables to be optimized. A variables selection strategy based on mutual information analysis and a new fill-in strategy are proposed. Second, the $g_{m}/I_{D}$ methodology-based optimization strategy is proposed. Optimization variables are not width and the length of transistors, but $g_{m}/I_{D}$ , $I_{D}$ and length. $g_{m}$ , $I_{D}$ and $g_{m}/I_{D}$ have a direct relationship to circuit performance. This is equivalent to search in circuit feature space, which could achieve better performance and handle constraints more easily. Four commonly used circuits, including low dropout regulator, two stage amplifiers, Bandgap voltage reference (VR), and VR are used for validation. Compared with other high-dimensional BO, common BO, and commercial tools (Cadence ADE_GXL), the proposed algorithm is found to produce the best optimization result and best stability. And, the ablation study shows the effectiveness and efficiency of two ingredients of the proposed algorithm.
- 15 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Components Letters
- Vol. 32 (5) , 444-447
Efficiency-Enhanced Wireless Power Transfer Based on Multiple Coupling Paths
This letter presents a novel efficiency-enhanced wireless power transfer (WPT) system operating at 13.56-MHz ISM band. Dual sub-resonators at both transmitting and receiving ends are employed to introduce multiple coupling paths and boost system efficiency. The closed-form equations are derived to verify the advantages of the proposed scheme. A prototype of the WPT system is implemented using the printed circuit board (PCB) technique, which features easy fabrication and small volume. The dual sub-resonators are fabricated on both sides of the PCB with a total dimension of 15 $\times15$ cm 2 . Experimental and simulated results which exhibit a good agreement are presented and discussed. An efficiency of 90% is achieved at 15 cm, implying an enhancement of approximately 7% as compared with the conventional WPT schemes.
- 15 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Microwave and Wireless Components Letters
- Vol. 32 (5) , 444-447
Efficiency-Enhanced Wireless Power Transfer Based on Multiple Coupling Paths
This letter presents a novel efficiency-enhanced wireless power transfer (WPT) system operating at 13.56-MHz ISM band. Dual sub-resonators at both transmitting and receiving ends are employed to introduce multiple coupling paths and boost system efficiency. The closed-form equations are derived to verify the advantages of the proposed scheme. A prototype of the WPT system is implemented using the printed circuit board (PCB) technique, which features easy fabrication and small volume. The dual sub-resonators are fabricated on both sides of the PCB with a total dimension of 15 $\times15$ cm 2 . Experimental and simulated results which exhibit a good agreement are presented and discussed. An efficiency of 90% is achieved at 15 cm, implying an enhancement of approximately 7% as compared with the conventional WPT schemes.