Jocelyn Pok
Jocelyn Pok has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
- Alvin Wei Ze Chew
Bentley Systems Singapore Pte Ltd., 3 Harbourfront Pl, Singapore 099254, Singapore
8 shared publications - Zheng Yi Wu
Bentley Systems Inc., 76 Watertown Rd, Suite 2D, Thomaston, CT 06787, USA
8 shared publications - Rony Kalfarisi
Bentley Systems Singapore Pte Ltd., 3 Harbourfront Pl, Singapore 099254, Singapore
6 shared publications - Xue Meng
Bentley Systems (Singapore) Pte Ltd
4 shared publications Jianping Cai
3 shared publicationsRony Kalfarisi
Senior Software Engineer, Bentley Systems Singapore Pte Ltd., 3 Harbourfront Pl, Singapore 099254
3 shared publications
Latest Publications
- Open Access
- 18 September 2024
- Published by MDPI AG in Engineering Proceedings
- Vol. 69 (1) , 147
A 24/7 Cloud-Hosted Solution Evaluation for Anomaly Detection and Localization of Large-Scale Water Distribution Networks in Singapore
In this study, a novel cloud-hosted software solution, titled as Anomaly Leak Finder (ALF), has been developed in collaboration with PUB, Singapore’s national water agency, to enhance leak detection and localization in four major water distribution networks (WDNs) in Singapore. The large networks which span over 1000 km of underground pipelines are monitored 24/7 with 90+ smart sensors. Leveraging on near real-time hydraulic time-series data, ALF employs data-driven prediction (DDP) and physics-based simulation (PBS) models to minimize the total non-revenue water (NRW) losses by detecting and localizing hidden pipe leak events before they become disruptive events.
- 18 September 2024
- Published by MDPI AG in Engineering Proceedings
- Vol. 69 (1) , 147
Open AccessA 24/7 Cloud-Hosted Solution Evaluation for Anomaly Detection and Localization of Large-Scale Water Distribution Networks in Singapore
In this study, a novel cloud-hosted software solution, titled as Anomaly Leak Finder (ALF), has been developed in collaboration with PUB, Singapore’s national water agency, to enhance leak detection and localization in four major water distribution networks (WDNs) in Singapore. The large networks which span over 1000 km of underground pipelines are monitored 24/7 with 90+ smart sensors. Leveraging on near real-time hydraulic time-series data, ALF employs data-driven prediction (DDP) and physics-based simulation (PBS) models to minimize the total non-revenue water (NRW) losses by detecting and localizing hidden pipe leak events before they become disruptive events.
- Open Access
- 29 August 2024
- Published by MDPI AG in Engineering Proceedings
- Vol. 69 (1) , 6
Anomaly Localization by Applying Data-Driven Analysis and Parallel Optimization of Hydraulic Model Calibration
This paper presents an integrated approach using both data-driven and hydraulic model-based methods to localize anomaly events in near real time (NRT). Upon detecting an NRT anomaly event, the pressure drops at sensor locations are calculated, followed by estimating the pressure drops at junction nodes via an inverse-distance weighted interpolation method. Clustering is then performed based on pressure drops at junction nodes and network topology to segregate and reduce the search areas. Afterwards, a genetic algorithm optimization is performed with hydraulic model simulations to further pinpoint the anomaly hotspots. The integrated method has been tested on real leakage events with field data, where the localized leak hotspots are within 300 m of the ground-truth leaks.
- 29 August 2024
- Published by MDPI AG in Engineering Proceedings
- Vol. 69 (1) , 6
Open AccessAnomaly Localization by Applying Data-Driven Analysis and Parallel Optimization of Hydraulic Model Calibration
This paper presents an integrated approach using both data-driven and hydraulic model-based methods to localize anomaly events in near real time (NRT). Upon detecting an NRT anomaly event, the pressure drops at sensor locations are calculated, followed by estimating the pressure drops at junction nodes via an inverse-distance weighted interpolation method. Clustering is then performed based on pressure drops at junction nodes and network topology to segregate and reduce the search areas. Afterwards, a genetic algorithm optimization is performed with hydraulic model simulations to further pinpoint the anomaly hotspots. The integrated method has been tested on real leakage events with field data, where the localized leak hotspots are within 300 m of the ground-truth leaks.
- Top Cited Papers
- 7 February 2023
- Published by Elsevier in Sustainable Cities and Society
- Vol. 91
High Fidelity Digital Twin-Based Anomaly Detection and Localization for Smart Water Grid Operation Management
- 7 February 2023
- Published by Elsevier in Sustainable Cities and Society
- Vol. 91
Top Cited PapersHigh Fidelity Digital Twin-Based Anomaly Detection and Localization for Smart Water Grid Operation Management
- 13 September 2022
- Published by Elsevier in Advances in Engineering Software
- Vol. 173
Predictive modeling framework accelerated by GPU computing for smart water grid data-driven analysis in near real-time
- 13 September 2022
- Published by Elsevier in Advances in Engineering Software
- Vol. 173
Predictive modeling framework accelerated by GPU computing for smart water grid data-driven analysis in near real-time
- Open Access
- 18 July 2022
- Published by Universitat Politecnica de Valencia
Acoustic Data Analysis Framework for Near Real-Time Leakage Detection and Localization for Smart Water Grid
Acoustic Data Analysis Framework for Near Real-Time Leakage Detection and Localization for Smart Water Grid
- 18 July 2022
- Published by Universitat Politecnica de Valencia
Open AccessAcoustic Data Analysis Framework for Near Real-Time Leakage Detection and Localization for Smart Water Grid
Acoustic Data Analysis Framework for Near Real-Time Leakage Detection and Localization for Smart Water Grid
- Open Access
- 18 July 2022
- Published by Universitat Politecnica de Valencia
NRW Estimation and Localization in Water Distribution Networks via Hydraulic Model Calibration using 24/7 Monitoring Data
NRW Estimation and Localization in Water Distribution Networks via Hydraulic Model Calibration using 24/7 Monitoring Data
- 18 July 2022
- Published by Universitat Politecnica de Valencia
Open AccessNRW Estimation and Localization in Water Distribution Networks via Hydraulic Model Calibration using 24/7 Monitoring Data
NRW Estimation and Localization in Water Distribution Networks via Hydraulic Model Calibration using 24/7 Monitoring Data
- 1 May 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Water Resources Planning and Management
- Vol. 148 (5) , 04022019
Daily Model Calibration with Water Loss Estimation and Localization Using Continuous Monitoring Data in Water Distribution Networks
Due to the increasing deployment of sensors in water distribution networks (WDNs) for continuous monitoring, hydrodynamic data are readily available for engineers to improve the daily operations of WDNs. In collaboration with Public Utility Board (PUB), Singapore’s National Water Agency, an alternative model calibration approach using continuously monitored data is proposed to facilitate PUB’s smart water grid (SWG). The generic approach was developed as an integrated solution methodology for practical engineers to conduct a series of systematic analyses daily, namely, (1) estimating the system’s daily nonrevenue water (NRW) volume and NRW time series; (2) adjusting the available pumps’ operational curves and control statuses, followed by calibrating the system’s net demand pattern to fulfill the flow balance accounting for the actual consumption; (3) identifying and rectifying possible offsets in the monitored pressure head values for each sensor station; (4) performing model calibration with anomaly localization analysis when the system’s total NRW volume exceeds its assumed background NRW volume; and (5) calibrating other physical properties to fulfill the system’s energy balance, especially for the peak demand hours. The effectiveness of our proposed approach was then tested and verified using a real-world WDN having total pipe length of with available monitoring data. Key findings from the case study analysis include (1) anomaly events localized including, but not limited to, five out of six reported leaks for the selected week to within 400 m with lead time of 1–2 days; (2) the system’s initial flow imbalance addressed by estimating the daily NRW volume and localizing the possible anomaly events; and (3) pipe roughness values calibrated to further improve the energy balance in the system, especially during the peak demand hours, by attaining an average mean absolute percentage error (MAPE) score of 2.5%.- 1 May 2022
- Published by American Society of Civil Engineers (ASCE) in Journal of Water Resources Planning and Management
- Vol. 148 (5) , 04022019
Daily Model Calibration with Water Loss Estimation and Localization Using Continuous Monitoring Data in Water Distribution Networks
Due to the increasing deployment of sensors in water distribution networks (WDNs) for continuous monitoring, hydrodynamic data are readily available for engineers to improve the daily operations of WDNs. In collaboration with Public Utility Board (PUB), Singapore’s National Water Agency, an alternative model calibration approach using continuously monitored data is proposed to facilitate PUB’s smart water grid (SWG). The generic approach was developed as an integrated solution methodology for practical engineers to conduct a series of systematic analyses daily, namely, (1) estimating the system’s daily nonrevenue water (NRW) volume and NRW time series; (2) adjusting the available pumps’ operational curves and control statuses, followed by calibrating the system’s net demand pattern to fulfill the flow balance accounting for the actual consumption; (3) identifying and rectifying possible offsets in the monitored pressure head values for each sensor station; (4) performing model calibration with anomaly localization analysis when the system’s total NRW volume exceeds its assumed background NRW volume; and (5) calibrating other physical properties to fulfill the system’s energy balance, especially for the peak demand hours. The effectiveness of our proposed approach was then tested and verified using a real-world WDN having total pipe length of with available monitoring data. Key findings from the case study analysis include (1) anomaly events localized including, but not limited to, five out of six reported leaks for the selected week to within 400 m with lead time of 1–2 days; (2) the system’s initial flow imbalance addressed by estimating the daily NRW volume and localizing the possible anomaly events; and (3) pipe roughness values calibrated to further improve the energy balance in the system, especially during the peak demand hours, by attaining an average mean absolute percentage error (MAPE) score of 2.5%.- Open Access
- 16 December 2021
- Published by IWA Publishing in Journal of Water Supply: Research and Technology—AQUA
- Vol. 71 (1) , 31-41
Data-driven and model-based framework for smart water grid anomaly detection and localization
With increasing adoption of advanced meter infrastructure, smart sensors together with SCADA (Supervisory Control and Data Acquisition) systems, it is imperative to develop novel data analytics and couple the results with hydraulic modeling to improve the quality and efficiency of water services. One important task is to timely detect and localize anomaly events, which may include, but not be limited to, pipe bursts and unauthorized water usages. In this paper, a comprehensive solution framework has been developed for anomaly detection and localization by formulating and integrating data-driven analytics with hydraulic model calibration. Data analysis for anomaly detection proceeds in multiple steps including the following: (1) data pre-processing to eliminate and correct erroneous data records, (2) outlier detection by statistical process control methods and deep machine learning, and (3) system anomaly classification by correlation analysis of multiple sensor events. Classified system anomaly events are subsequently localized via hydraulic model calibration. The integrated solution framework is developed as a user-friendly and effective software tool, tested, and validated on the selected target areas in Singapore.
- 16 December 2021
- Published by IWA Publishing in Journal of Water Supply: Research and Technology—AQUA
- Vol. 71 (1) , 31-41
Open AccessData-driven and model-based framework for smart water grid anomaly detection and localization
With increasing adoption of advanced meter infrastructure, smart sensors together with SCADA (Supervisory Control and Data Acquisition) systems, it is imperative to develop novel data analytics and couple the results with hydraulic modeling to improve the quality and efficiency of water services. One important task is to timely detect and localize anomaly events, which may include, but not be limited to, pipe bursts and unauthorized water usages. In this paper, a comprehensive solution framework has been developed for anomaly detection and localization by formulating and integrating data-driven analytics with hydraulic model calibration. Data analysis for anomaly detection proceeds in multiple steps including the following: (1) data pre-processing to eliminate and correct erroneous data records, (2) outlier detection by statistical process control methods and deep machine learning, and (3) system anomaly classification by correlation analysis of multiple sensor events. Classified system anomaly events are subsequently localized via hydraulic model calibration. The integrated solution framework is developed as a user-friendly and effective software tool, tested, and validated on the selected target areas in Singapore.